About this file
This document is a Construction Specification for Watering Facility (Code 614) from the Natural Resources Conservation Service (NRCS) in Montana. It provides detailed requirements for the installation of stock tanks and storage tanks, including foundation preparation, pipe materials and installation, tank materials and installation, and wildlife escape ramps. Key requirements include:
- Tanks shall be placed on a leveled and compacted foundation of rock, gravel, or stable soils to prevent settling
- Concrete, steel, and plastic tanks must meet specific thickness, reinforcement, and finishing requirements
- Flexible membrane or bentonite liners are required for impervious tank bottoms
- Wildlife escape ramps must be installed on tanks over 3 square feet to allow small animals to safely exit
The document also references a related federal contract opportunity for the Saguaro Park Tank Install Phase III project on the Rio Grande National Forest. This $10,000 - $50,000 solicitation (1240LT24R0033) involves replacement of two livestock watering tanks and redevelopment of the Horse Canyon Line, including spring redevelopment, pipe installation, and additional tank installations. The period of performance is June 1 - October 1, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Statement of Work SaguacheParkPhaseIIIV2.docx | DOCX document | |
| SaguacheParkPhaseIII_ContractMapAUPDATED.pdf | ||
| A1 NRCS_PipelinePlumbingSpecs.pdf | ||
| A5 Proposed_Spring_Development_Sketch_USFS_5.2018.pdf | ||
| A3 SaguacheParkPhaseIII_ContractMapA.pdf | ||
| Statement of Work SaguacheParkPhaseIII.docx | DOCX document | |
| A6 Wage Determination CO20240001.txt | TXT text file | |
| A4 SaguacheParkPhaseIII_ContractMapB_Vicinity.pdf | ||
| 1240LT24R0033 RFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION SPECIFICATION Watering Facility MT-614-1
NRCS-Montana November 2015
WATERING FACILITY
(Code 614)
1. SCOPE
The work covered by this specification includes furnishing all equipment, materials, and labor and performing all operations in connection with the installation of stock tanks and storage tanks as shown on the drawings, as herein specified, or as staked in the field.
2. FOUNDATION PREPARATION
Clear all trees, brush, rocks, and rubbish from the foundation area to a distance of 10 feet beyond the edge of the stock tank in all directions.
Tank floors shall be placed on rock, fine gravel, or sand. Where these materials are not present, a minimum 6-inch leveled and compacted layer of fine gravel, sand, or stable well compacted, or undisturbed soils that will not settle differentially, shall be placed under the floor.
The area immediately surrounding the tank shall be smoothed and graded to drain away from the tank.
Unless otherwise designated on the drawings, a minimum 6-foot wide, 6-inch thick coarse gravel, scoria, concrete, or soil cement paving apron shall be provided around the tank perimeter.
3. PIPE MATERIALS AND
INSTALLATION
Pipe and fittings shall be in accordance with Practice Construction Specification MT-516, Livestock Pipeline.
All stock tanks and storage tanks shall be installed in accordance with the manufacturer's recommendations and these specifications. In the event that these specifications are less restrictive than the manufacturer's recommendations, the manufacturer's recommendations shall govern.
Backfill for inlets, outlets, or overflow pipes shall either be compacted to the density of the surrounding material or backfilled with fine gravel or sand.
4. TANK MATERIALS AND
INSTALLATION
All tanks and associated materials shall be new unless specifically approved otherwise.
Bottoms and top edges of the tanks shall be level to within one-half inch across the tank.
Posts and Lumber
Posts shall be cedar, juniper, heart redwood, or treated with preservatives not prohibited by the EPA.
Lumber shall be new or approved used material of the minimum dimensions shown in the drawings. Knots, splits, or other imperfections shall not impair the strength or life of the structure.
Concrete
All concrete and reinforcing steel shall meet the requirements of construction specification MT-106, MT-106A, or MT- 106B. Unless otherwise specified in the special provisions, concrete shall be Class 4000, air-entrained.
Where concrete walls are specified, the walls and floor shall be placed at the same time or the bond area between floor slab and wall shall be roughened, thoroughly cleaned and if specified, waterstops placed to ensure a watertight joint.
Minimum floor and wall thickness are specified below:
CONSTRUCTION SPECIFICATION Watering Facility MT-614-2
Floors: (maximum width or length − 15 feet)
• 6 inches thick − #4 bars at 12-inch centers.
Walls: (maximum height 36 inches)
• 4 inches thick − #3 bars at 9-inch centers.
• 5 inches thick − #4 bars at 12-inch centers.
• 6 inches thick − #4 bars at 9-inch centers.
Reinforcing bars shall be bent and spliced so they are continuous in the floor and walls.
Splices shall be a minimum of 30 bar diameters.
Wall and floor thickness and steel configuration for concrete tank or trough components not meeting these minimums require appropriate structural analysis.
Pre-cast Concrete Stock Tanks
Pre-cast concrete stock tanks must be approved by NRCS prior to installation.
Submit the manufacturer, model of tank, dimensions, and reinforcing details of the proposed pre-cast tank to the NRCS for approval.
Concrete Masonry (Hollow-Tile Block)
Concrete block shall meet the requirements of ASTM-C 90.
Mortar for concrete masonry shall be freshly prepared and uniformly mixed in the ratio by volumes of 1 part cement, ½ part lime, 4- ½ parts sand and enough water to make a workable mix.
Grout for the cells of hollow-tile blocks shall be of fluid consistency and mixed in the ratio by volumes, 1 part cement, 3 parts sand, or 1 part cement, 3 parts sand, and 2 parts pea gravel and enough water to make a workable mix.
Steel Stock Tanks
All steel tank material shall be galvanized, stainless steel, or completely factory plastic-coated or epoxy-coated.
Top edges of tanks shall be reinforced with rolled pipe, galvanized tube, angle iron or other suitable reinforcement.
Tanks with steel bottoms shall be minimum 24 gauge for less than 6 feet diameter, and 20 gauge for larger diameters. The bottom and sides shall be joined in such a manner as to provide a locked and watertight seam.
Steel walls for concrete, bentonite or membrane bottom tanks shall be constructed of galvanized steel not less than 16 gauge.
The tank shall include a reinforced rolled top edge. Galvanized steel shall meet the requirements of specification ASTM-A 444.
The galvanized steel shall not be in contact with reinforcing steel. Concrete chairs or non-electrical conducting materials shall be used to accomplish separation.
Plastic Stock Tanks
Exposed plastic tanks shall have ultraviolet resistance. Prior to use, each make, model, and size of stock tanks manufactured from polyethylene plastic or other plastic compounds must be approved by NRCS. A minimum two-year written guarantee from the manufacturer is required.
Rubber Tire Stock Tanks
Rubber Tire Stock Tanks. Large-diameter, heavy equipment, rubber tires may be used for stock tanks. Top rims may be left in place for winter tanks. When the top rim is cut off, the steel belts shall be trimmed off flush. The tires shall be set on a firm, level, foundation such as bedrock, compacted gravel, or stable undisturbed soils that will not settle differentially. For materials used to seal the rubber tire tank:
CONSTRUCTION SPECIFICATION Watering Facility MT-614-3
• Concrete shall be a minimum of 6 inches.
• Fiberglass or steel plate shall be sealed and fastened to the tire bead.
• Bentonite should not be used in tanks subject to long dry periods.
Fiberglass
The tank or trough shall be constructed with the mold on the inside to insure a non-porous interior surface.
Thickness
Fiberglass drinking tanks shall have a nominal minimum thickness of 3/16-inch.
Fiberglass for use in tanks with concrete bottoms shall have a minimum nominal thickness of 1/4-inch.
Glass Reinforcement
Fiberglass content shall be 30-40 percent.
Resin
Resin shall meet the following specifications:
• Commercial grade orthophalic polyester except as specified under finish, below.
• Resin content shall be a maximum of 70 percent.
• Ultimate tensile strength of 13,000 psi minimum.
• Ultimate flexural strength 20,000 psi minimum.
• Cured compressive strength 24,000 psi minimum at break.
• Barcol hardness 36 minimum.
Finish
Finish shall meet the following specifications:
• Sand and fiberglass resin or sand and gel-coat resin final finish to tank interior bottom.
• Gel-coat, isophalic-interior.
• Barcol hardness 36 minimum.
• Thickness 14-20 mils minimum.
Top Reinforcement
Tank top edge shall be flange reinforced by:
2-inch straight flange, minimum of 3/8-inch thick or 2-inch curled or rolled flange, minimum of ¼-inch thick.
Impervious Membrane Tank Bottoms
Impervious membranes used in tank bottoms shall be designed to last the useful life of the tank. Typical materials include concrete, steel, commercially-processed bentonite, fiberglass, or flexible sheeting material such as polyvinyl chloride (PVC), butyl rubber, high density polyethylene (HDPE), asphaltic-sealed fabric liner or other sheeting material specifically manufactured for use as a buried impervious membrane.
Minimum thickness or application rates shall be:
• Concrete: 6 inches
• Steel: 20 ga.
• Fiberglass: 3/16-inch
• Bentonite: 4 lbs./sq. foot
• Plastics: 10 mils
• Asphaltic-Sealed Fabric: 1.5 mm
Concrete Placement
Concrete used for bases in rubber tire tanks shall be as specified above.
Steel and Fiberglass Plate Placement
Steel and fiberglass plates shall be sealed and fastened to the bottom of the rim using mastic sealant.
CONSTRUCTION SPECIFICATION Watering Facility MT-614-4
Flexible Membrane Placement
The flexible membrane shall be placed after the steel or fiberglass rim is in place. The soil materials at the bottom of the tank shall be excavated to a depth of approximately 6 inches below the bottom of the steel or fiberglass rim.
The size of the flexible membrane shall be such that it will lie loosely on the subgrade (approximately 10 percent slack) at all points around the tank, and extend up above the bottom of the rim a minimum of 9 inches.
The membrane shall be sealed to the inside of the rim using a sealer as recommended by the liner material manufacturer. The seal shall be at least 6 inches wide and continuous around the complete perimeter of the tank.
A minimum protective covering of 9 inches of sand or silty sand material shall be placed over the membrane.
Bentonite Placement
Bentonite shall be placed after the steel or fiberglass rim is in place. The bottom of the tank shall be filled to 3 inches above the bottom of the rim with compacted sand or finer-grained material. The fill surface shall be smooth. Uniformly place the bentonite over the entire surface with particular attention to providing good contact with the tank walls.
A minimum protective covering of 6 inches of sand or silty sand material shall be placed over the bentonite.
Above-Ground Storage Tanks
Common construction materials include, fiberglass, steel, and plastic. Adequate coatings or ultraviolet-resistant materials shall be used to meet the practice life. Tanks shall be founded on concrete or gravel, and shall be adequately tied down to prevent lateral movement by wind or cattle in the empty condition. Installation shall be in accordance with the manufacturer’s recommendations. Prior to use, each make, model, and size of above-ground storage tank must be approved by NRCS. A minimum two-year written guarantee from the manufacturer is required.
Buried Storage Tanks
Manufactured tanks shall not be used for buried installations unless they are determined to be structurally sound by one of the following methods.
1. A structural analysis performed and sealed by a registered Professional Engineer, or a structural analysis by an NRCS Engineer with the proper job approval authority.
2. A performance vacuum test completed by the tank manufacturer in accordance with the applicable specifications of the American Society of Testing and Materials (ASTM).
3. An on-site investigation by an NRCS Engineer of a similar or the proposed tank that has already been in service for at least one year, and loaded both externally and internally to full capacity.
Unless a design or manufacturer's guidelines show otherwise, buried, or mounded tanks will require pea gravel or crushed stone bedding 6 inches below and up to the midline of the tank. Pea gravel shall be clean naturally rounded with a mix of particle sizes not less than 1/8-inch or more than 3/4-inch. Crushed stone shall be washed with angular particle sizes not less than 1/8-inch or more than 1/2-inch.
5. WILDLIFE ESCAPE RAMPS
Many animals, including birds, bats, and other small mammals, drown in livestock water tanks unless there is an obvious escape route. All such tanks will have
CONSTRUCTION SPECIFICATION Watering Facility MT-614-5 wildlife escape ramps installed with the following exceptions:
• Ritchie-style waterers used in corrals.
• Covered fiberglass “frost-free” tanks where there is only an open water area of 3 square feet or less.
• Covered stock tanks with small drinking ports.
Escape Ramp Requirements:
• Contact the sides of the tank so that animals swimming around the tank perimeter are forced to make contact with the escape ramp; i.e., they cannot swim underneath the ramp.
• Reach to the bottom of the trough or tank
• Firmly secured to the trough rim
• Built of durable material with a rough surface animals can grip
• Have a slope no steeper than 45 degrees
• Located to cause minimal interference with livestock.
See the attached “Wildlife Escape Ramp Design” for a suggested approach to ramp construction. Also see Montana Biology Technical Note MT-47 for an alternative design and discussion of important wildlife considerations associated with livestock watering facilities.
For round tanks greater than 10 feet in diameter, and for rectangular tanks, one escape ramp for every 30 feet of tank perimeter shall be installed.
Other Wildlife Considerations:
• Most bat species need an unobstructed water surface of 10 feet long by 2.5 feet wide. Whenever possible, use tanks having at least a 10-foot diameter or length.
• Avoid placing fences or cross braces over the water whenever possible. If a fence across the tank is necessary, place it off-center to maximize the length of un-obstructed water on one side of the fence. If feasible, locate cross-bracing under the rim of the tank.
• Orient the long axis of rectangular tanks with the prevailing wind direction if possible to maximize the “swoop” distance for bats.
• Access ramps to the tank are not recommended. These ramps attract many wildlife species which could drown in the tank if the escape ramp is not functional.
6. FINISH AND CLEANUP
All construction shall be performed in a workmanlike manner and the job site shall have a neat appearance when finished.
7. MEASUREMENT AND PAYMENT
(Used only if applicable)
For items of work for which specific unit prices are established each item will be measured to the nearest unit applicable.
Payment for each item will be made at the agreed-to unit price for that item.
Such payment will constitute full compensation for all labor, equipment, tools and materials necessary for completion of the work.
Compensation for any item of work shown on the drawings or described in the special provisions but not listed on the bid schedule will be considered incidental to and included in the pay items listed on the bid schedule.
http://www.nrcs.usda.gov/wps/portal/nrcs/detail/mt/technical/ecoscience/bio/?cid=nrcs144p2_056656
3-4”
Cut Lines
24”
24”
22.5”
Cut Line Cut Line
Cut Out Area
1.5”
19”
Tank Hook (cut straight across or leave for additional hook length) Hook Alternative Design: Use two 3/16” rods to form the hangers (as shown in the attached photo).
CONSTRUCTION SPECIFICATION Watering Facility MT-614-6
MATERIALS: 10-14 gauge, flattened or regular, expanded metal. Recommend flattened expanded metal ¾” - #9.
4’x 8’ Panel of Expanded Metal (yields 8 tank ladders)
28”
Bend lines are 2.25” from the centerline
1. Torch cut eight 24” x 24” squares. Total cutting length is 20’. Time: Approx. ½ hour.
2. Make a template of the cutout areas and mark the cut lines with permanent marker or soapstone.
3. Torch cut the cut lines. Total cutting length is 46” per ladder. Time: Approx. 40 minutes (8 ladders).
4. Mark the bend lines. Use a tin break or bend over a metal edge using a hammer.
Bend at a 45˚ angle. Time: Approx. 40 min.
5. Leave the hook flat for ease of transport and storage. At installation, use a hammer to bend the hook over the rim of the stock tank.
6. Paint with a rust resistant, non-toxic neutral color. Two coats. Time: Approx. 40 min.
Cost to Fabricate Eight Ladders Cost estimate for materials $45-60 (as of 11/06) Labor estimate is 2.5 hours
32”
4.5”
CONSTRUCTION SPECIFICATION Watering Facility MT-614-7
PURPOSE: Provides an approved design for wildlife escape ladders in watering facilities.
Because many species of wildlife drown in watering facilities, NRCS Standard, Watering Facility (Code 614), requires installation of a wildlife escape ladder in these facilities. This attached design was developed by Rocky Mountain Bird Observatory (RMBO) and may be used to meet the standard requirements. The design was revised by NRCS to provide dimensions for ease of fabrication.
The key design component is to provide a ramp with “holes”, which touches the sides of the stock tank. This makes it easier for the trapped animal to find the ramp. Designs that do not provide this, result in the trapped animal swimming along the perimeter of the tank, passing underneath the ramp, until exhausted and eventually drowning.
The design is somewhat diamond-shaped; the front ramp is 4.5 inches wide and 28 inches long, and will touch the bottom of a 24-inch deep stock tank. The wings are bent down to a 45˚ angle, and designed to touch the vertical wall of the stock tank. The top hook can be bent around the rim of the stock tank (metal or tire tank). No drilling is required.