Bessey Pumphouse Arch Specs.pdf

PDF 423 KB Posted

Attached to
Bessey Nursery Construction Correction & Completion Federal contract opportunity
Solicitation number
1240LT24R0012
Issued by
Department of Agriculture Forest Service

About this file

This document provides specifications for construction work at the Bessey Nursery in Halsey, Nebraska. The solicitation was issued by the U.S. Department of Agriculture Forest Service for correction and completion of construction at the Bessey Nursery Pump Building. A mandatory site visit is scheduled for March 5, 2024 at 9:00 AM at the nursery location.

The specifications include requirements for cast-in-place concrete, rough carpentry, sheathing, shop-fabricated wood trusses, fiberglass reinforced plastic panels, thermal insulation, doors and windows, and other finish work. Materials and installation methods are specified for concrete, dimension lumber, preservative-treated wood, sheathing, roof trusses, siding, flashing, sealants, insulation, and other products. The specifications provide performance criteria and references to industry standards for all construction work.

View the file

Other files for this federal contract opportunity

Other files attached to Bessey Nursery Construction Correction & Completion, newest first.
File Type Posted
Generator Propane Line Redline.pdf PDF
01 3200_Construction Progress Documentation.pdf PDF
Irrigation System AsBuiltNotes.pdf PDF
01 4000 Quality Requirements (Supplement).pdf PDF
Q and A_Second Round.docx DOCX document
BesseyPumphouseArchDrawings.pdf PDF
sign in sheet for site visit.pdf PDF
1240LT24R0012_Amendment 1.pdf PDF
Bessey_RevisedSectionC.3_03072024.docx DOCX document
Bessey_RevisedSectionL.1_452.215-71_b_TechProposalInstructions_03072024.docx DOCX document
Bessey_RevisedSectionJ2_03072024.docx DOCX document
Bessey Pre Bid Q And A.docx DOCX document
Bessey_RevisedSectionB1ScheduleOfItems_03072024.docx DOCX document
1240LT24R0012.pdf PDF
J-5. Amendment & Modifications.zip ZIP file
J-4.Original Specifications & Drawings.zip ZIP file
J.2 Schedule Item Work Descriptions.pdf PDF
J-6. Supplemental Pumphouse & Waterline Drawings.zip ZIP file
J.1 Wage Rate Decision.pdf PDF
J..7 Determination of Responsibility.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BESSEY NURSERY PUMP BUILDING 001500-1

NEBRASKA NFs AND NGs LIST OF SPECIFICATIONS

SECTION 001500

NEBRASKA & SAMUEL R. MCKELVIE NF’s &

BUFFALO GAP, FORT PIERRE, AND OGLALA NG’s

GREENHOUSE COMPLEX

LIST OF SPECIFICATIONS

PART 1 – GENERAL

1.1 DESCRIPTION

A. List of Contract Specifications

1. Index of Specifications

DIVISION 3 – CONCRETE

Section 033000 Cast-In-Place Concrete

DIVISION 6 – WOOD AND PLASTICS

Section 061000 Rough Carpentry Section 061600 Sheathing Section 061753 Shop-Fabricated Wood Trusses Section 066400 Fiberglass Reinforced Plastic Panels

DIVISION 7 – THERMAL AND MOISTURE PROTECTION

Section 072100 Thermal Insulation Section 073113 Asphalt Shingles Section 074646 Fiber Cement Siding Section 076200 Sheet Metal Flashing and Trim Section 079200 Joint Sealants

DIVISION 8 – DOORS AND WINDOWS

Section 081100 Steel Doors and Frames Section 087100 Door Hardware

DIVISION 9 – FINISHES

Section 092000 Gypsum Board Section 099120 Painting

BESSEY NURSERY PUMP BUILDING 001500-2

NEBRASKA NFs AND NGs LIST OF SPECIFICATIONS

DIVISION 31 – EARTHWORK

Section 312250 Earthwork

END OF SECTION 001500

BESSEY NURSERY PUMP BUILDING 033000 - 1

NEBRASKA NFs AND NGs CAST-IN-PLACE CONCRETE

SECTION 033000

CAST-IN-PLACE CONCRETE

PART 1 – GENERAL

1.1 SUMMARY

A. This Section includes cast-in-place concrete, including formwork, reinforcement, joints, concrete materials, mix design, placement procedures, and finishes.

1.2 SUBMITTALS

A. As specified in “Submittal Procedures” in Division 1 Section “General Requirements.”

1. Product Data:

a. Provide for each manufactured material and product including admixtures, patching compounds, joint systems, curing compounds, and sealants.

b. Submit certifications that admixtures used in the concrete mix are compat-ible with each other and the aggregates.

2. Certificates and Reports:

a. Concrete Mix Design: Comply with ASTM C 94; furnish statement of composition of concrete mix and evidence that mix will meet quality spec-ified herein, including cement content, fly ash content, entrained air con-tent, design slump and unit weight. Provide either 1) or 2) below for each mix proposed.

1) Compression test results for proposed mixes. Include standard devi-ation data for each proposed concrete mix based on statistical rec-ords where applicable.

2) Curve of water-cementitious materials ratio versus concrete cylinder strength for each formulation of concrete proposed based on labora-tory tests. The cylinder strength shall be the average of the 28 day cylinder strength test results for each mix. Provide results of 7 and 14 day tests if available.

b. Admixtures: Submit admixture types and manufacturers with a written statement showing chloride content if any chloride was added during manufacture.

c. Sources of cement, pozzolan, and aggregates.

d. Material Data Sheets (MSDS) for all concrete components and admix-tures.

e. Submit results of concrete slump, air content, and compressive strength tests.

BESSEY NURSERY PUMP BUILDING 033000 - 2

f. Provide a written Hot and Cold Weather Concrete Placing Plan prior to start of any concrete operations.

3. Shop Drawings:

a. Submit detailed drawings for fabrication, bending and placement of con-crete reinforcement indicating size, dimension, bending, place and con-struction joint details. Submit drawing showing locations of any construc-tion joints not shown. Drawings shall be on minimum 11 x 17 paper. In-clude all accessories specified and required to support reinforcement.

Comply with ACI Detailing Manual SP 66 and requirements of ACI 315.

1) Show all bar splice locations and lap lengths. Show the placement of all required additional reinforcement (around openings, at cor-ners, etc.) as shown on the Drawings.

2) Bill of materials (bar list). Show the placement of each bar in the bill of materials on the placing drawings.

3) Bar bending details. Reference bars to the same identification marks shown on the placing drawings. Include standard bending diagrams in the submittal, as applicable.

4) Identify the grade of reinforcing steel in the submittal. Identify any bars that are of a different grade or that have special coatings.

5) Show all items embedded in concrete, including hold downs and an-chor bolts. Where embed items other than the manufacturer listed on the drawings is proposed, submit data for the substituted product for approval prior to installation.

1.3 QUALITY ASSURANCE

A. Manufacturer Qualifications: A firm experienced in manufacturing ready-mixed con-crete products complying with ASTM C 94 requirements for production facilities and equipment.

B. Comply with ACI 301, "Specification for Structural Concrete for Buildings", includ-ing the following, unless modified by the requirements of the Contract Documents.

1. General requirements, including submittals, quality assurance, acceptance of structure, and protection of in-place concrete.

2. Formwork and form accessories.

3. Steel reinforcement and supports.

4. Concrete mixtures.

5. Handling, placing, and constructing concrete.

C. Test Reports: Comply with requirements in “Quality Requirements” in Division 1 Section “General Requirements.”

BESSEY NURSERY PUMP BUILDING 033000 - 3

1. Fine aggregates – Conformity with ASTM C33 standards, including sieve analy-sis, physical properties, and deleterious substance.

2. Coarse aggregates – Conformity with ASTM C33 standards, including sieve analysis, physical properties, and deleterious substance.

3. Cements – Conformity with ASTM C150 standards, including chemical analysis and physical properties for each type.

4. Pozzolans – Conformity with ASTM C618 standards, including chemical analy-sis and physical properties.

D. Concrete Mix Design:

1. Strength Requirements: ASTM C 94.

2. Testing:

a. Slump and Air Content Tests: Samples shall be taken from every truck af-ter discharge of approximately 15 percent of load. If slumps differ by more than 2 inches, the mixer or agitator shall not be used until condition causing this variation is corrected. The equipment for these tests will be furnished by Contractor's certified independent testing laboratory techni-cian.

b. Compression Tests: Test specimens shall be made and cured in accord-ance with ASTM C 31 and tested in accordance with ASTM C 39, using standard 6-inch diameter by 12-inch high cylinders, and will be taken by the Contractor's certified independent testing laboratory technician. Cur-ing, shipment to, and testing by an independent laboratory shall be at the expense of the Contractor. The Contractor shall obtain 4 cylinders for every 50 cubic yards of concrete placed or for each major placement dur-ing the day whichever is more frequent. One cylinder shall be tested at an age of 7 days for information, two at an age of 28 days for acceptance, and one held in reserve to be tested if required.

c. Report results of concrete testing in accordance with Section 1.3.C.

3. Enforcement of Strength Requirements: If the 28-day strength test fails to meet the requirements of ASTM C 94, the Contracting Officer may require that core samples be taken and tested in accordance with ASTM C 42, at Contractor's ex-pense. If the core tests are below strength, if there is evidence of damage by freezing, or if the concrete fails to meet specifications in other ways, the Con-tracting Officer may require that the defective concrete be removed and re-placed at no additional expense to the Government.

E. The Contractor is responsible for quality control, including workmanship and materi-als furnished by subcontractors and suppliers.

BESSEY NURSERY PUMP BUILDING 033000 - 4

1. Inspection or testing does not relieve the Contractor of responsibility to perform the Work in accordance with the Contract Documents.

2. Workmanship: The Contractor is responsible for and shall bear the cost of cor-recting concrete work which does not conform to the specified requirements in-cluding, but not limited to, strength, tolerances, joint types and patterns, and fin-ishes. Correct deficient concrete by means acceptable to the Contracting Of-ficer. The cost of extra work incurred to approve corrective work shall be borne by the Contractor.

F. Record of Work: A record shall be kept by the General Contractor listing the time and date of placement of all concrete for the structure. Such record shall be kept until the completion of the project and shall be available to the Contracting Officer for exami-nation at any time.

G. Preinstallation Conference: Conduct conference at Project site.

PART 2 – PRODUCTS

2.1 MATERIALS

A. Formwork: Furnish formwork and form accessories according to ACI 301.

B. Steel Reinforcement:

1. Reinforcing Bars: ASTM A 615, Grade 60, deformed.

2. Plain-Steel Wire: ASTM A 82, as drawn.

3. Plain-Steel Welded Wire Fabric: ASTM A 185, fabricated from as-drawn steel wire into flat sheets.

C. Concrete Materials:

1. Portland Cement: ASTM C 150, Type II or I/II, use one brand of cement throughout project.

2. Normal-Weight Aggregate: ASTM C 33, uniformly graded, not exceeding 1-inch for footings and ¾ inch for walls and slabs.

3. Water: Potable, complying with ASTM C 94.

4. Synthetic Fiber: Fibrillated or monofilament polypropylene fibers engineered and designed for use in concrete, complying with ASTM C 1116, Type III, 1/2 to 1-1/2 inches long.

5. Fly ash will be allowed as a cementitious component of the mix. Fly ash shall conform to ASTM C618 Class C or F. Fly ash shall not exceed 15% of total cementitious material by weight.

D. Admixtures:

1. Air-Entraining Admixture: ASTM C 260.

2. Water-Reducing Admixture: ASTM C 494, Type A.

BESSEY NURSERY PUMP BUILDING 033000 - 5

3. High-Range, Water-Reducing Admixture: ASTM C 494, Type F.

4. Water-Reducing and Accelerating Admixture: ASTM C 494, Type E.

5. Water-Reducing and Retarding Admixture: ASTM C 494, Type D.

E. Vapor Barrier: Polyethylene sheet, ASTM D 4397, not less than 6 mils thick.

F. Joint-Filler Strips: ASTM D 1751, asphalt-saturated cellulosic fiber.

G. Curing Materials:

1. Evaporation Retarder: Waterborne, monomolecular film forming, manufactured for application to fresh concrete.

2. Absorptive Cover: AASHTO M 182, Class 2, burlap cloth made from jute or kenaf.

3. Moisture-Retaining Cover: ASTM C 171, polyethylene film or white burlap-polyethylene sheet.

4. Water: Potable.

5. Clear, membrane-forming Curing Compound: ASTM C 309, Type 1, Class B.

6. Clear, membrane-Forming Curing and Sealing Compound: ASTM C 1315, Type 1, Class A.

2.2 CONCRETE MIXES

A. Comply with ACI 301 requirements for concrete mixtures.

B. Prepare design mixes, proportioned according to ACI 301, for normal-weight concrete determined by either laboratory trial mix or field test data bases, as follows:

1. Compressive Strength (28 Days): 4000 psi.

2. Cementitious Material Content: Minimum of 564 pounds per cubic yard.

3. Maximum Water/Cement Ratio: 0.45.

4. Slump: 4 inches.

a. Slump Limit for Concrete Containing High-Range Water-Reducing Ad-mixture: Not more than 8 inches after adding admixture to plant- or site-verified, 2- to 3-inch slump.

C. Add air-entraining admixture at manufacturer's prescribed rate to result in concrete at point of placement having an air content of 6.0 percent within a tolerance of plus or minus 1.5 percent.

D. Synthetic Fiber Reinforcement: For slabs on grade (building, sidewalks, equipment pads, etc.).

1. Uniformly disperse in concrete mix at manufacturer's recommended rate, but not less than 1.5 lb/cu. yd.

2.3 CONCRETE MIXING

BESSEY NURSERY PUMP BUILDING 033000 - 6

A. Ready-Mixed Concrete: Comply with ASTM C 94.

1. Discharge all concrete from truck mixer, agitator, or other transporting device not later than 1-1/2 hours or 300 revolutions of the drum after the mixing water has been added.

2. When air temperature is between 85 and 90 deg F, reduce mixing and delivery time from 1-1/2 hours to 75 minutes; when air temperature is above 90 deg F, reduce mixing and delivery time to 60 minutes.

3. If delivery trucks cannot meet these requirements, the water and cement must be introduced into the mixer at the project site.

B. Project-Site Mixing: Measure, batch, and mix concrete materials and concrete accord-ing to ASTM C 94. Mix concrete materials in appropriate drum-type batch machine mixer.

1. For mixer capacity of 1 cu. yd. or smaller, continue mixing at least 1-1/2 minutes, but not more than 5 minutes after ingredients are in mixer, before any part of batch is released.

2. For mixer capacity larger than 1 cu. yd., increase mixing time by 15 seconds for each additional 1 cu. yd..

C. Provide batch ticket for each batch discharged and used in the Work, indicating Pro-ject identification name and number, date, mix type, mix time, quantity, and amount of water added. Record approximate location of final deposit in structure.

2.4 PATCHING GROUT

A. Portland cement, water, and fine sand passing a No. 30 mesh sieve.

B. Sikagrout 212 and Sikadur 32 Ni-Mod Manufactured by Sika Corporation, 875 Valley Brooks Avenue, Lyndhurst, NJ 07071, Ph (201) 933-8800 or equal.

2.5 NONSHRINK GROUT

A. Masterflow 928, manufactured by Master Builders, Inc., Construction Products Divi-sion, 23700 Chagrin Blvd., Cleveland, OH 44122, Ph (216) 831-5500, or equal.

PART 3 – EXECUTION

3.1 INSTALLATION, GENERAL

A. Formwork: Design, construct, erect, shore, brace, and maintain formwork according to ACI 301.

1. Variation from plumb lines and surfaces of column footings and walls shall not exceed 1/8 inch in 10 feet.

BESSEY NURSERY PUMP BUILDING 033000 - 7

2. Variation in linear building lines from established position of columns, piers, or walls shall not exceed 1 inch in any bay of 20 feet or 1 inch in 40 feet or greater.

3. Variation in cross section dimension of footings and thickness of slabs and walls shall not exceed minus 1/4 inch or plus 1 inch.

B. Vapor Barrier: Install, protect, and repair vapor-barrier sheets according to ASTM E 1643; place sheets in position with longest dimension parallel with direction of pour.

1. Lap joints 6 inches and seal with manufacturer's recommended tape.

2. Place vapor barrier over free draining base course compacted with mechanical equipment to elevation tolerances of plus 0 inch or minus 3/4 inch.

C. Steel Reinforcement: Comply with CRSI's "Manual of Standard Practice" for fabricat-ing, placing, and supporting reinforcement.

1. Do not cut or puncture vapor retarder. Repair damage and reseal vapor retarder before placing concrete.

2. Except where shown otherwise on drawings, a minimum concrete coverage for steel reinforcement shall be as follows:

Minimum Cover Cast against and permanently exposed to earth (footings). 3 inches Exposed to earth or weather (foundation Walls, beams, slab and columns 2 inches

D. Joints: Construct joints true to line with faces perpendicular to surface plane of con-crete.

1. Construction Joints: Locate and install so as not to impair strength or appear-ance of concrete, at locations indicated or as approved by CO.

2. Isolation Joints: Install joint-filler strips at junctions with slabs-on-grade and vertical surfaces, such as column pedestals, foundation walls, grade beams, and other locations, as indicated.

3. Control Joints in Slabs-on-Grade: Form weakened-plane control joints, spaced a maximum of 12 feet center to center. Construct control joints for a depth equal to at least one-fourth of the concrete thickness, as follows:

a. Grooved Joints: Form control joints after initial floating by grooving and finishing each edge of joint with tool to a radius of 1/8 inch. Repeat grooving of control joints after applying surface finishes. Eliminate tool marks on concrete surfaces.

E. Tolerances: Comply with ACI 117, "Specifications for Tolerances for Concrete Con-struction and Materials."

3.2 CONCRETE PLACEMENT

BESSEY NURSERY PUMP BUILDING 033000 - 8

A. Comply with recommendations in ACI 304R for measuring, mixing, transporting, and placing concrete.

B. Extra Water:

1. Deliver concrete to site in exact quantities required by design mix.

2. Should extra water be required for workability before depositing concrete, and water/cement ratio of accepted mix design has not been exceeded, General Con-tractor's superintendent shall have sole authority to authorize addition of water.

Any additional water added to mix after leaving batch plant shall be indicated on truck ticket and signed by person responsible.

3. Where extra water is added to concrete it shall be mixed thoroughly for 50 revo-lutions of drum before depositing.

4. Water may be added to the site only once for each batch.

5. An additional slump and air content test shall be performed following the addi-tion of any water.

C. Cold Weather Placing:

1. Protect concrete work from physical damage or reduced strength which could be caused by frost, freezing actions, or low temperatures, in compliance with ACI 306 and as herein specified.

2. When air temperature has fallen to or is expected to fall below 40oF, uniformly heat water and aggregates before mixing to obtain a concrete mixture tempera-ture of not less 50oF, and not more than 80oF at point of placement.

3. Do not use frozen materials or materials containing ice or snow. Do not place concrete on frozen subgrade or subgrade containing frozen materials.

4. Do not use calcium chloride, salt or other materials containing antifreeze agents or chemical accelerators, unless otherwise accepted in mix designs.

D. Hot Weather Placing:

1. When hot weather conditions exist that would seriously impair quality and strength of concrete, place concrete in compliance with ACI 305 and as herein specified.

2. Cool ingredients before mixing to maintain concrete temperature at time of placement below 90oF.

3. Mixing water may be chilled or chopped ice may be used to control temperature provided water equivalent of ice is calculated to total amount of mixing water.

3.3 FINISHING FORMED SURFACES

A. Rough-Formed Finish: As-cast concrete texture imparted by form-facing material with tie holes and defective areas repaired and patched, and fins and other projections exceeding 1/4 inch in height rubbed down or chipped off.

1. Apply to concrete surfaces not exposed to public view.

BESSEY NURSERY PUMP BUILDING 033000 - 9

B. Smooth-Formed Finish: As-cast concrete texture imparted by form-facing material, arranged in an orderly and symmetrical manner with a minimum of seams. Repair and patch tie holes and defective areas. Completely remove fins and other projections.

1. Apply to concrete surfaces exposed to public view or to be covered with a coat-ing or covering material applied directly to concrete, such as waterproofing or dampproofing.

3.4 FINISHING UNFORMED SURFACES

A. General: Comply with ACI 302.1R for screeding, restraightening, and finishing oper-ations for concrete surfaces. Do not wet concrete surfaces.

B. Screed surfaces with a straightedge and strike off. Begin initial floating using bull floats or darbies to form a uniform and open-textured surface plane before excess moisture or bleed water appears on the surface.

1. Do not further disturb surfaces before starting finishing operations.

C. Trowel Finish: Apply a hard trowel finish to surfaces indicated and to floor and slab surfaces to be acid stained or to be covered with resilient flooring or carpet.

D. Nonslip Broom Finish: Apply a nonslip broom finish to surfaces indicated and to ex-terior concrete platforms, steps, and ramps. Immediately after float finishing, slightly roughen trafficked surface by brooming with fiber-bristle broom perpendicular to main traffic route.

3.5 CONCRETE PROTECTION AND CURING

A. General: Protect freshly placed concrete from premature drying and excessive cold or hot temperatures. Comply with ACI 306.1 for cold-weather protection and follow recommendations in ACI 305R for hot-weather protection during curing.

B. Evaporation Retarder: Apply evaporation retarder to concrete surfaces if hot, dry, or windy conditions occur before and during finishing operations. Apply according to manufacturer's written instructions after placing, screeding, and bull floating or dar-bying concrete, but before float finishing.

C. Begin curing after finishing concrete, but not before free water has disappeared from concrete surface.

D. Cure formed and unformed concrete for at least seven days as follows:

1. Curing Compound: Apply uniformly in continuous operation by power spray or roller according to manufacturer's written instructions. Recoat areas subjected to heavy rainfall within three hours after initial application. Maintain continuity of coating and repair damage during curing period.

BESSEY NURSERY PUMP BUILDING 033000 - 10

a. Do not use curing compound where it may adversely effect finishes or coatings. Use only as approved, in writing, by the Contracting Officer.

3.6 NONSHRINK GROUT

A. Use nonshrink grout to fill sleeves and voids under equipment and column bases.

Grout shall be mixed and used in accordance with manufacturer's recommendations.

Exposed edges shall be smooth, straight, and even.

3.7 REMOVAL OF FORMS AND SHORES

A. The supporting forms and shoring shall not be removed until the members have ac-quired sufficient strength to support their weight and the loads superimposed thereon safely.

B. In no case may any forms or shoring be removed until the time and sequence has been approved by the CO.

C. Earlier removal than specified below may be approved by the CO, based on the weather and tests of job-cured cylinders.

D. All formwork shall be removed without damage to the concrete.

E. The minimum time for forms and shoring to remain in place shall be as follows:

1. Structural slabs and beams: 7 days.

2. Soffits of openings in walls: 7 days.

3. Walls and columns: 32 hours.

4. Slabs on grade and sides of footings: 24 hours.

F. Any request for earlier removal of forms and shoring shall be made to the CO in writ-ing, along with supporting evidence that the safety of the structure will not be im-paired.

G. Shoring shall be adequate in strength and shall be so designed and placed that the load from successive parts of the structure will be transmitted directly through the false-work without creating bending or shearing stresses in the concrete.

H. During the period that the forms are in place on the concrete work, keep wet at all times.

3.8 FIELD QUALITY CONTROL

A. Testing Agency: Contractor will engage a qualified independent testing and inspect-ing agency to sample materials, perform tests, and submit test reports during concrete placement. Tests will be performed according to ACI 301.

BESSEY NURSERY PUMP BUILDING 033000 - 11

1. Testing Frequency: Obtain slump tests from every truckload. Obtain one com-posite sample for each day's pour of each concrete mix exceeding 5 cu. yd. plus one set for each additional 50 cu. yd. or fraction thereof.

2. Slump: Test slump of the concrete sample for each strength test and whenever consistency of concrete seems to vary, using ASTM C 143.

3. Test air content for each strength test in accordance with either ASTM C 231, ASTM C 173, or ASTM C 138.

4. Determine temperature of concrete sample for each strength test.

B. Batch Certification

1. A concrete batch certificate containing all items shown on the example in this section shall be completed and furnished to the CO with each load.

2. Concrete Batch Certification Form (page 03300-8) will be supplied by the For-est Service or the contractor may use his own forms.

3.9 DAMAGED OR DEFECTIVE CONCRETE

A. Remove damaged or defective concrete before completion and acceptance of the work and replace with acceptable concrete

BESSEY NURSERY PUMP BUILDING 033000 - 12

U.S. DEPARTMENT OF AGRICULTURE

FOREST SERVICE

REGION 2

Concrete Batch Certification

Name of ready-mix batch plant

Serial Number of ticket Date Truck No.

Name of contractor

Name and location of job

Class of concrete

Amount of concrete

Time loaded Reading of revolution counter or time at first

Addition of water

Type and brand of cement

Amount of cement in batch

Water-cement ratio Total water added

Admixtures (amount and type)

Maximum size of aggregate

Weight of fine aggregate

Weight of coarse aggregate

I hereby certify that the above statements are true and correct.

Signature of ready-mix plant representative

Water added by receiver Initials

END OF SECTION

BESSEY NURSERY PUMP BUILDING 061000 - 1

NEBRASKA NFs AND NGs ROUGH CARPENTRY

SECTION 061000

ROUGH CARPENTRY

PART 1 - GENERAL

1.1 SUMMARY

A. This Section includes the following:

1. Framing with dimension lumber.

2. Wood blocking and nailers.

3. Wood furring.

4. Wood-preservative-treated lumber.

1.2 SUBMITTALS

A. As specified in “Submittal Procedures” in Division 1 Section “General Requirements.”

1. Product Data: For each type of process and factory-fabricated product indicated.

a. Include data for wood preservative and fire-retardant treatment from chemical treatment manufacturer and certification by treating plant that materials comply with requirements.

2. Material Certificates: For dimension lumber species to comply with minimum allowable unit stresses. Indicate species and grade selected for each use and design values approved by the American Lumber Standards Committee Board of Review.

3. Research/Evaluation Reports: For the following, showing compliance with building code in effect for project:

a. Wood preservative-treated wood.

PART 2 - PRODUCTS

2.1 WOOD PRODUCTS, GENERAL

A. Lumber: DOC PS 20 and applicable rules of grading agencies indicated. If no grading agency is indicated, provide lumber that complies with the applicable rules of any rules-writing agency certified by the ALSC Board of Review. Provide lumber graded by an agency certified by the ALSC Board of Review to inspect and grade lumber under the rules indicated.

1. Factory mark each piece of lumber with grade stamp of grading agency.

BESSEY NURSERY PUMP BUILDING 061000 - 2

2. For exposed lumber indicated to receive stained or natural finish, mark grade stamp on end or back of each piece, or omit grade stamp and provide certificates of grade compliance issued by grading agency.

3. Provide dressed lumber, S4S, unless otherwise indicated.

2.2 WOOD-PRESERVATIVE-TREATED MATERIALS

A. General: Where lumber or plywood is indicated as preservative treated or specified to be treated, comply with applicable requirements of AWPA C2 (lumber) and AWPA C9 (plywood).

1. Kiln-dry material after treatment to maximum moisture content of 19 percent for lumber and 15 percent for plywood.

2. Mark lumber with treatment quality mark of an inspection agency approved by the American Lumber Standards Committee Board of Review.

3. Application: Treat items indicated on Drawings, and the following:

a. Wood cants, nailers, curbs, equipment support bases, blocking, stripping, and similar members in connection with roofing, flashing, vapor barriers, and waterproofing.

b. Wood sills, sleepers, blocking, furring, stripping, and similar concealed members in contact with concrete.

c. Wood framing members less than 18-inches (460-mm) above grade.

d. Wood floor plates that are installed over concrete slabs directly in contact with earth.

B. Borate Preservative Treated Wood Products:

1. Borate Preservative Treatment: Disodium Octoborate (DOT).

2. Preservative Treatment Standards: AWPA P5.

3. Treatment Level: Provide borate preservative treatment retention level

.recommended by manufacturers to provide the following minimum protection, an indicated on wood products quality stamp specified in Quality Assurance Article: 42 DOT retention if warranty is required or expected.

a. Protection against North American subterranean termites, decay, and insects: 0.25 lbs/cu. ft. (4 kg/cu. m.) DOT retention (0.17 lbs/cu. ft (2.7 kg/cu. m.) B2 O3) minimum retention.

4. Field Applied End Cut Preservative

a. Tim-bor disodium octaborate tetrahydrate (DOT), 10% solution

b. Cooper Naphthenate, 2% solution, cooper metal base.

5. Available Manufacturer: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

BESSEY NURSERY PUMP BUILDING 061000 - 3

a. Osmose Wood Preserving Inc. “Advance Guard Borate PTW”.

2.3 DIMENSION LUMBER FRAMING

A. Maximum Moisture Content: 19 percent.

B. Non-Load-Bearing Interior Partitions: Construction or No. 2 grade of the any species:

C. Framing Other Than Non-Load-Bearing Partitions: No. 2 grade and the following species:

1. Douglas fir-larch, WCLIB, or WWPA.

D. Framing Other Than Non-Load-Bearing Interior Partitions: Any species and grade with a modulus elasticity of at least 1,600,000 psi and an extreme fiber stress in bending of at least 900 psi for 2-inch nominal (38 mm actual) thickness and 12-inch nominal (286 mm actual) width for single member use.

2.4 MISCELLANEOUS LUMBER

A. General: Provide miscellaneous lumber for support or attachment of other construction, including the following:

1. Blocking.

2. Nailers.

3. Furring.

B. For items of dimension lumber size, provide Construction or No. 2 grade lumber with 19 percent maximum moisture content of any species.

C. For concealed boards, provide lumber with 19 percent maximum moisture content and any of the following species and grades:

1. Mixed Southern Pine, No. 2 grade; SPIB.

2. Eastern Softwoods, No. 2 Common grade; NeLMA

3. Northern Species, No. 2 Common Grade; NLGA.

4. Western woods, Construction or No. 2 Common grade; WCLIB or WWPA.

2.5 FASTENERS

A. General: Provide fasteners of size and type indicated that comply with requirements specified.

1. Where rough carpentry is exposed to weather, in ground contact, pressure-preservative treated, or in area of high relative humidity, provide fasteners with hot-dip zinc coating complying with ASTM A 153/A 153M.

BESSEY NURSERY PUMP BUILDING 061000 - 4

B. Power-Driven Fasteners: NES NER-272.

C. Bolts: Steel bolts complying with ASTM A 307, grade A (ASTM F 568M, Property Class 4.6); with ASTM A 563 (ASTM A 563M) hex nuts and, where indicated, flat washers.

2.6 METAL FRAMING ANCHORS

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1. Simpson Strong-Tie Company, Inc.

B. Allowable Design Loads: Provide products with allowable design loads as published by manufacturer that meet or exceed those of products of manufacturers listed.

Manufacturer’s published values shall be determined from empirical data or by rational engineering analysis and demonstrated by comprehensive testing performed by an qualified independent testing agency.

C. Galvanized Steel Sheet: Hot-dip, zinc-coated steel sheet complying with ASTM A 653/A 653M, G60 (Z180) coating designation.

2.7 MISCELLANEOUS MATERIALS

A. Sill-Sealer Gaskets: Self-adhered, closed-cell polyethylene foam, 3/8 inch (9.5 mm) thick, selected from manufacturer's standard widths to suit width of sill members indicated. Basis-of-Design Product: Subject to compliance with requirements, provide "Protecto Wrap’s Premium Energy Sill Sealer" or comparable product.

B. Flexible Flashing: Composite, self-adhesive, flashing product consisting of a pliable, butyl rubber compound, bonded to a high-density polyethylene film, aluminum foil, or spunbonded polyolefin to produce an overall thickness of not less than 0.025 inch (0.6 mm).

PART 3 - EXECUTION

3.1 INSTALLATION

A. Set rough carpentry to required levels and lines, with members plumb, true to line, cut, and fitted. Fit rough carpentry to other construction; scribe and cope as needed for accurate fit. Locate furring, nailers, blocking, and similar supports to comply with requirements for attaching other construction.

B. Framing Standard: Comply with AF&PA’s “Details for Conventional Wood Frame Construction,” unless otherwise indicated.

BESSEY NURSERY PUMP BUILDING 061000 - 5

C. Metal Framing Anchors: Install metal framing to comply with manufacturer’s written instructions.

1. Prevent direct contact between treated wood and aluminum using an appropriate method as follows:

a. Maintain minimum ¼ inch (6.a mm) space between treated wood and aluminum building components using polyethylene or nylon spacers.

b. Maintain separation using minimum 10 mil (0.25 mm) thick polyethylene film between treated wood and aluminum.

D. Do not splice structural members between supports, unless otherwise indicated.

E. Comply with AWPA M4 for applying field treatment to cut surfaces of preservative-treated lumber.

F. Securely attach rough carpentry work to substrate by anchoring and fastening as indicated, complying with the following:

1. NES NER-272 for power-driven fasteners.

2. Table 2304.9.1,”Fastening Schedule,” in the ICC’s International Building Code.

3.2 PROTECTION

A. Protect wood that has been treated with inorganic boron (SBX) from weather. If, despite protection, inorganic boron-treated wood becomes wet, apply EPA-registered borate treatment. Apply borate solution by spraying to comply with EPA-registered label.

END OF SECTION 061000

BESSEY NURSERY PUMP BUILDING 061000 - 6

This page intentionally left blank.

BESSEY NURSERY PUMP BUILDING 061600 - 1

NEBRASKA NFs AND NGs SHEATHING

SECTION 061600

SHEATHING

PART 1 – GENERAL

1.1 SUMMARY

A. This Section includes the following:

1. Exterior Wall sheathing.

2. Interior Wall sheathing.

3. Soffits.

4. Soffit venting.

5. Roof sheathing.

6. Underlayment.

7. Sheathing joint-and-penetration treatment.

8. Flexible flashing at openings in sheathing.

1.2 SUBMITTALS

A. As specified in “Submittal Procedures” in Division 1 Section “General Requirements.”

1. Product Data: For each type of process and factory-fabricated product. Indicate component materials and dimensions and include construction and application details.

a. Include data for wood-preservative treatment from chemical treatment manufacturer and certification by treating plant that treated plywood com-plies with requirements.

2. Research/Evaluation Reports: For the following:

a. Preservative-treated plywood.

b. Building wrap.

1.3 DELIVERY, STORAGE, AND HANDLING

A. Stack plywood and other panels flat with spacers between each bundle to provide air circulation. Provide for air circulation around stacks and under coverings.

PART 2 – PRODUCTS

2.1 WOOD PANEL PRODUCTS, GENERAL

A. Plywood: Either DOC PS 1 or DOC PS 2, unless otherwise indicated.

BESSEY NURSERY PUMP BUILDING 061600 - 2

B. Oriented Strand Board: DOC PS 2, FSC certified.

2.2 PRESERVATIVE-TREATED PLYWOOD

A. Preservative Treatment by Pressure Process: AWPA C9.

B. Mark plywood with appropriate classification marking of an inspection agency ac-ceptable to authorities having jurisdiction.

C. Application: Treat items where indicated on drawings and plywood in contact with concrete.

2.3 EXTERIOR WALL SHEATHING

A. Plywood Wall Sheathing: Exposure 1 sheathing.

B. Oriented-Strand-Board Wall Sheathing: Exposure 1 sheathing, FSC certified.

2.4 INTERIOR WALL SHEATHING

A. Plywood Wall Sheathing, ½ inch T&G finish grade plywood with horizontally with offset joints, minimum Class C fire rating.

2.5 SOFFIT VENTING

A. Continuous soffit vent, aluminum, white, 2.75” x 96”, providing 9 sq. inches per foot, model SV202 by Air Vent, Inc.

2.6 ROOF SHEATHING

A. Plywood Roof Sheathing: Structural I, Exposure 1 sheathing.

B. Oriented-Strand-Board Roof Sheathing: Exposure 1 sheathing, FSC certified.

2.7 FASTENERS

A. General: Provide fasteners of size and type indicated on Drawings.

1. For wall and roof sheathing panels, provide fasteners with corrosion-protective coating having a salt-spray resistance of more than 800 hours according to

ASTM B 117.

2.8 WEATHER-RESISTANT SHEATHING PAPER

A. Building Paper: ASTM D 226, Type 1 (No. 15 asphalt-saturated organic felt), unper-forated.

BESSEY NURSERY PUMP BUILDING 061600 - 3

B. Building Wrap: ASTM E 1677, Type I air retarder; with flame-spread and smoke-developed indexes of less than 25 and 450, respectively, when tested according to ASTM E 84; UV stabilized; and acceptable to authorities having jurisdiction.

1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following:

a. Dow Chemical Company (The); Styrofoam Weathermate Plus Brand Housewrap.

b. DuPont (E. I. du Pont de Nemours and Company); Tyvek Commercial- Wrap.

c. Ludlow Coated Products; Barricade Building Wrap.

d. Pactiv, Inc.; GreenGuard Ultra Wrap.

2. Water-Vapor Permeance: 28 perms, when tested in accordance with ASTM E96, Method B.

C. Building-Wrap Tape: Tape recommended by building-wrap manufacturer.

2.9 MISCELLANEOUS MATERIALS

A. Adhesives for Field Gluing Panels to Framing: Formulation complying with ASTM D 3498 that is approved for use indicated by manufacturers of both adhesives and panels.

1. VOC Content: 70g/L or less when calculated according to 40 CFR 59, Sub-part D (EPA Method 24).

B. Flexible Flashing: Self-adhesive, rubberized-asphalt compound, bonded to a high-density, polyethylene film to produce an overall thickness of not less than 0.025 inch (0.6 mm).

PART 3 – EXECUTION

3.1 INSTALLATION, GENERAL

A. Securely attach to substrate by fastening as indicated, complying with the following:

1. NES NER-272 for power-driven fasteners.

2. Table 2304.9.1, "Fastening Schedule," in ICC's "International Building Code."

B. Coordinate sheathing installation with flashing and joint-sealant installation so these materials are installed in sequence and manner that exclude exterior moisture.

C. Do not bridge building expansion joints; cut and space edges of panels to match spac-ing of structural support elements.

3.2 WOOD STRUCTURAL PANEL INSTALLATION

BESSEY NURSERY PUMP BUILDING 061600 - 4

A. General: Comply with applicable recommendations in APA Form No. E30K, "APA Design/Construction Guide: Residential & Commercial."

1. Comply with "Code Plus" installation provisions in guide referenced in para-graph above.

B. Fastening Methods: Fasten panels as indicated below:

1. Wall and Roof Sheathing: Nail to wood framing.

3.3 WEATHER-RESISTANT SHEATHING-PAPER INSTALLATION

A. General: Cover sheathing with weather-resistant sheathing paper as follows:

1. Cut back barrier 1/2 inch (13 mm) on each side of the break in supporting mem-bers at expansion- or control-joint locations.

2. Apply barrier to cover vertical flashing with a minimum 4-inch (100-mm) over-lap, unless otherwise indicated.

B. Building Paper: Apply horizontally with a 2-inch (50-mm) overlap and a 6-inch (150-

mm) end lap; fasten to sheathing with galvanized staples or roofing nails.

C. Building Wrap: Comply with manufacturer's written instructions.

1. Seal seams, edges, fasteners, and penetrations with tape.

2. Extend into jambs of openings and seal corners with tape.

3.4 SOFFIT VENT INSTALLATION

A. Comply with manufacturer’s instructions.

3.5 FLEXIBLE FLASHING INSTALLATION

A. Apply flexible flashing where indicated to comply with manufacturers written instruc-tions.

1. Lap seams and junctures with other materials at least 4 inches (100 mm), except that at flashing flanges of other construction, laps need not exceed flange width.

2. Lap flashing over weather-resistant building paper at bottom and sides of open-ings.

3. Lap weather-resistant building paper over flashing at heads of openings.

4. After flashing has been applied, roll surfaces with a hard rubber or metal roller.

END OF SECTION 061600

BESSEY NURSERY PUMP BUILDING 061753 - 1

NEBRASKA NFs AND NGs SHOP-FABRICATED WOOD TRUSSES

SECTION 061753

SHOP-FABRICATED WOOD TRUSSES

PART 1 - GENERAL

1.1 SUMMARY

A. This Section includes the following:

1. Wood roof trusses.

2. Metal truss accessories.

1.2 PERFORMANCE REQUIREMENTS

A. Structural Performance: Provide metal-plate-connected wood trusses capable of withstanding design loads indicated. Comply with requirements in TPI 1.

1.3 SUBMITTALS

A. As specified in “Submittal Procedures” in Division 1 Section “General Requirements.”

1. Product Data: For metal-plate connectors, metal-framing anchors, bolts, and fasteners indicated.

2. Shop Drawings: Provide show drawings signed and sealed by a Professional Engineer licensed in Colorado. Show fabrication and installation details for trusses.

a. Show location, pitch, span, camber, configuration, and spacing for each type of truss required.

b. Indicate sizes, and stress grades, and species of lumber.

c. Indicate locations of permanent bracing required to prevent buckling of individual truss members due to design loads.

d. Indicate type, size, material, finish, design vales, orientation, and location of metal connector plates.

e. Show splice details and bearing details.

f. For installed products indicated to comply with design loads, include structural analysis data signed and sealed by the qualified Colorado licensed professional engineer responsible for their preparation.

3. Qualification Data: For Metal-plate manufacturer and Fabricator.

4. Research/Evaluation Reports: For the following, showing compliance with building code in effect for Project:

a. Metal-plate connectors.

b. Metal truss accessories.

1.4 QUALITY ASSURANCE

BESSEY NURSERY PUMP BUILDING 061753 - 2

A. Metal Connector-Plate Manufacturer Qualifications: A manufacturer that is a member of TPI and that complies with TPI quality-control procedures in TPI 1 for manufacture of connector plates.

1. Manufacturer's responsibilities include providing professional engineering services needed to assume engineering responsibility.

2. Engineering Responsibility: Preparation of Shop Drawings and comprehensive engineering analysis by a qualified Colorado licensed professional engineer.

B. Fabricator Qualifications: Shop that participates in a recognized quality-assurance program that complies with quality-control procedures in TPI 1 and that involves third-party inspection by an independent testing and inspecting agency.

C. Comply with applicable requirements and recommendations of the following publications:

1. TP1 1, "National Design Standard for Metal Plate Connected Wood Truss Construction"

2. TPI DSB, “Recommended Design Specification for Temporary Bracing of Metal Plate Connected Wood Trusses.”

3. TPI HIB, "Commentary and Recommendations for Handling, Installing & Bracing Metal Plate Connected Wood Trusses".

D. Wood Structural Design Standard: Comply with applicable requirements in AFPA's "National Design Specifications for Wood Construction" and its "Supplement".

PART 2 - PRODUCTS

2.1 DIMENSION LUMBER

A. Lumber: DOC PS 20 and applicable rules of lumber grading agencies certified by the American Lumber Standards Committee Board of Review. Provide lumber graded by an agency certified by the ALSC Board of Review to inspect and grade limber under the rules indicated.

1. Provide dry lumber with 19 percent maximum moisture content at a time of dressing.

B. Grade and Species: Any species for truss chord and web members, graded visually or mechanically, and capable of supporting required loads without exceeding allowable design values according to AFPA's "National Design Specifications for Wood Construction" and its "Supplement".

C. Permanent Bracing: Provide wood bracing that complies with requirements for miscellaneous lumber in Division 6 Section “Rough Carpentry”.

2.2 METAL PRODUCTS

BESSEY NURSERY PUMP BUILDING 061753 - 3

A. Metal Connector Plates: Fabricate connector plates to comply with TPI 1 from hot-dip galvanized steel sheet complying with ASTM A 653/A 653M, G60 (Z180) coating designation; Designation SS, Grade 33, and not less than 0.036 inch (0.9 mm) thick.

1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Alpine Engineered Products, Inc.

b. CompuTrus, Inc.

c. Eagle Metal Products.

d. Jager Industries, Inc.

e. Mitek Industries, Inc.; a subsidiary of Berkshire Hathaway Inc.

f. Robbins Engineering, Inc.

g. TEE-LOK Corporation; a subsidiary of Berkshire Hathaway Inc.

h. Truswal Systems Corporation.

B. Fasteners: Where trusses are exposed to weather, in ground contact, or in area of high relative humidity, provide fasteners with hot-dip zinc coating complying with

ASTM A 153/A 153M.

1. Nails, Brads, and Staples: ASTM F 1667.

2. Power-Driven Fasteners: NES NER-272.

3. Wood Screws: ASME B18.6.1.

4. Lag Bolts: ASME B18.2.1. (ASME B18.2.3.8M).

5. Bolts: Steel bolts complying with ASTM A 307, Grade A (ASTM F 568M, Property Class 4.6); with ASTM A 563 (ASTM A 563M) hex nuts and, where indicated, flat washers.

C. Metal Truss Accessories: Provide truss accessories made from hot-dip, zinc-coated steel sheet complying with ASTM A 653/A 653M, G60 (Z180) coating designation.

1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Cleveland Steel Specialty Co.

b. Harlen Metal Products, Inc.

c. KC Metals Products, Inc.

d. Simpson Strong-Tie Company, Inc.

e. Southeastern Metals Manufacturing Co., Inc.

f. USP Structural Connectors.

2. Allowable Design Loads: Provide products with allowable design loads, as published by manufacturer, that meet or exceed those of basis-of-design products. Manufacturer's published values shall be determined from empirical

BESSEY NURSERY PUMP BUILDING 061753 - 4

data or by rational engineering analysis and demonstrated by comprehensive testing performed by a qualified independent testing agency.

2.3 FABRICATION

A. Assemble truss members in design configuration indicated; use jigs or other means to ensure uniformity and accuracy of assembly with joints closely fitted to comply with tolerances in TPI 1. Position members to produce design camber indicated.

1. Fabricate wood trusses within manufacturing tolerances in TPI 1.

B. Connect truss members by metal connector plates located and securely embedded simultaneously in both sides of wood members by air or hydraulic press.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install wood trusses only after supporting construction is in place and is braced and secured.

B. If trusses are delivered to Project site in more than one piece, assemble trusses before installing.

C. Hoist trusses into place by lifting equipment suited to sizes and types of trusses required, exercising care not to damage truss members or joints by out-of-plane bending or other causes.

D. Install and brace trusses according to TPI recommendations and as indicated.

E. Anchor trusses securely at bearing points; use metal framing anchors. Install fasteners through each fastener hole in metal framing anchor according to manufacturer's fastening schedules and written instructions.

F. Securely connect each truss ply required for forming built-up girder trusses.

G. Install and fasten permanent bracing during truss erection and before construction loads are applied. Anchor ends of permanent bracing where terminating at walls or beams.

1. Install bracing to comply with Division 6 Section “Rough Carpentry.”

2. Install and fasten strongback bracing vertically against vertical web of parallel-chord floor trusses at centers indicated.

H. Install wood trusses within installation tolerances in TPI 1.

I. Do not cut or remove truss members.

BESSEY NURSERY PUMP BUILDING 061753 - 5

J. Replace wood trusses that are damaged or do not meet requirements.

END OF SECTION 061753

BESSEY NURSERY PUMP BUILDING 061753 - 6

BESSEY NURSERY PUMP BUILDING 066400 - 1

NEBRASKA NFs AND NGs FIBERGLASS REINFORCED PLASTIC PANELS

SECTION 066400

FIBERGLASS REINFORCED PLASTIC PANELS

PART 1- GENERAL

1.1 SUMMARY

A. The work in this section consists of preparation of the substrate, the furnishing and installation of fiberglass reinforced plastic (FRP) panels.

1.2 QUALITY ASSURANCE

A. Manufacturer: Minimum of 10 years’ experience in the production, sales, and technical support of FRP panels and related materials.

1.3 SUBMITTALS

A. As specified in Division 1 Section “Submittal Procedures.”

1. Product Data: Submit manufacturer’s product literature and data including:

a. Preparation instructions and recommendations.

b. Storage and handling requirements and recommendations.

c. Installation methods.

d. Color chart.

2. Shop Drawings: Submit shop drawings to indicate materials, details, and accessories. Include layout diagram indicting the location of each panel and joining method.

3. Installer Qualifications: Submit copy of installer’s certificate indicating certification from the manufacturer.

4. Manufacturer’s Material Safety Data Sheet (MSDS) for each product being used.

5. Samples: For each finish product submit two samples, 6 inch square, in the color specified.

6. Sample Warranty.

B. Closeout Submittals: As specified in Division 1 Section “Closeout Procedures.”

1. Operation and maintenance data: Include methods for maintaining installed products and precautions against cleaning materials and methods detrimental to finishes and performance.

2. Warranties.

1.4 PRODUCT DELIVERY, STORAGE, AND HANDLING

BESSEY NURSERY PUMP BUILDING 066400 - 2

A. Packing and Shipping: Delivered materials to the site in the Manufacturer's packaging, clearly identified with the product name and manufacturer.

B. Store materials in accordance with the manufacturer’s instructions. Store materials in dry, enclosed area with adequate protection from moisture. Maintain storage temperature ≥ 65oF.

C. Waste Disposal: Provide adequate disposal facilities for non-hazardous waste generated during installation of the system.

1.5 PROJECT CONDITIONS

A. Maintain temperature range between 65oF and 80oF 48 hours before, during, and 24 hours after installation of flooring.

PART 2 – PRODUCTS

2.1 WALL PANELS

A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1. Panolam Industries International, Inc.

2. Kal-Lite Division, Kalwall Corporation.

3. Marlite.

4. Interstate Plastics.

B. Fiberglass reinforced thermosetting polyester resin panel sheets complying with

ASTM D5319.

1. Fire Rating: ASTM E84, Class A.

2. Flexural Strength: ASTM D790, 1.0 x104 psi.

3. Flexural Modulus: ASTM D790, 3.1 x105 psi.

4. Tensile Strength: ASTM D638, 7.0 x103 psi.

5. Tensile Modulus: ASTM D638, 1.6 x105 psi.

6. Barcol Hardness: ASTM D2583, 35.

7. Water Absorption: ASTM D570, 0.2 percent.

8. Panel size: 4 foot wide by either 8 or 10 foot high.

9. Thickness: 0.09 inches.

10. Back Surface: Smooth.

11. Front Surface Texture: Smooth.

12. Color: As selected by Contracting Officer.

C. Accessories:

1. Vinyl moldings including inside and outside…