This document is Attachment 5 to a federal contract solicitation for the Deschutes National Forest, containing supplemental planting specifications and detailed unit information sheets for tree planting, tube installation, and grubbing work across three ranger districts: Bend, Fort Rock, and Sisters.
The specifications detail planting requirements across multiple base and optional award units. Contractors must plant ponderosa pine (PP) or mixed conifer species (PP + Douglas-fir + Larch) using bareroot stock with container protection or rigid mesh tubes. Planting methods require hoedad or shovel application with 12-inch diameter scalped planting holes at depths of 10-12 inches to expose moist mineral soil. Average spacing requirements range from 15' x 15' to 20' x 20' with microsite emphasis on suitable existing trees. Root length specifications are 10 inches with tolerance of +/- 1.5 inches. Grubbing requirements mandate removal of all live vegetation within 36-inch diameter areas around planted seedlings, with root crown removal to 2-4 inches below soil surface. Rigid mesh tube installation is required only on current year plantings. For the Sisters ranger district unit 12, no power equipment is permitted for grubbing operations. Base award units total 698 acres across the Bend/Fort Rock districts with numerous optional units totaling 698 acres. Elevation ranges from 4,100 to 5,120 feet with varying slopes and aspects. Access points are specified by road designation for each unit.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10/
5/ GRUBBING
DIAMETER
(INCHES)
DEPTH
(INCHES)
PLACEMENT DIAMETER
(INCHES)
15' x 15'
Microsite Emphasis
15' x 15'
Microsite Emphasis
15' x 15'
15' x 15'
Microsite Emphasis
15' x 15'
Microsite Emphasis
15' x 15'
Microsite Emphasis
15' x 15' Microsite Emphasis
15' x 15' Microsite Emphasis
15' x 15'
Microsite Emphasis
15' x 15'
Microsite Emphasis
Base DAR 10 7 Flat 4,320 Hoedad or shovel 12" 3/ 4/
BFR Supplemental Planting Specifications Detailed Unit Info Sheet (DUIS)
REMARKS2/ SCALPING
4/
4/
4/
4/
4/
3/
3/
No Suitable existing PP Container 10" Rigid Mesh
Tube
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube Base
Oldwood 1A
18 Flat 4,240 Hoedad or shovel 12" 3/ 4/
36" Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube 4/
Rigid Mesh Tube
Base Tepee Salv
5C 4 Flat 4,750
Hoedad or shovel
12"
12" 3/ 36" Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"4/
10" Rigid Mesh Tube
Base Tepee Salv
3B 5 Flat 4,840
Hoedad or shovel
12" 3/ 36" Suitable existing PP Container4/ Base
Tepee Salv 2C
11 Flat 4,750 Hoedad or shovel
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube Base
SWAMP
WELLS
FIRE REFO
47 Flat 4,700
Hoedad or shovel
12" 3/
No Suitable existing PP Container 10" Rigid Mesh
Tube
Microsite Emphasis
Base DAR 9 23 Flat 4,360 Hoedad or shovel 12"
3/ No Suitable existing PP Container 10" Rigid Mesh
Tube Base
Darlene 3 Salvage 03
25 Flat 4,320 Hoedad or shovel 12"
12" 3/
10" Rigid Mesh Tube
Base Darlene 3
Salvage 02 42 Flat 4,320
Hoedad or shovel
12" 3/ No Suitable existing PP ContainerBase
Darlene 3 Salvage 01
59 Flat 4,320 Hoedad or shovel
Rigid Mesh Tube
No Suitable existing PP Container 10"
7/
SPECIES &
STOCK
TYPE TO BE
PLANTED
8/ ROOT
LENGTH
(INCH)
9/
TYPE OF
SEEDLING
PROTECTION
REQUIRED
AWARD UNIT
NAME
AND
NUMBER
ACRES ASPECT
AND
SLOPE %
ELEV.
(FEET)
REQUIRED
PLANTING
METHOD
1/
AVERAGE
PLANTING
SPACING
(FEET)
PLANTING SITE PREPARATION 6/
SPECIES
& SIZE OF
SUITABLE
EXISTING
TREES
ATTACHMENT 5
1240BE26Q0020
Deschutes NF, Bend Fort Rock Sisters RD’s
Tree Planting, Tube Installation, and Grubbing
DIAMETER
(INCHES)
DEPTH
(INCHES)
PLACEMENT DIAMETER
(INCHES)
15' x 15'
Microsite Emphasis
16' x 16'
Microsite Emphasis
15' x 15' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
20' x 20' Microsite Emphasis
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 12" 3/ 4/ 10"
Rigid Mesh Tube if award
Optional Flatside Refo 6B
10 Flat 4,920 Hoedad or shovel 12" 3/ 4/ No
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Rigid Mesh Tube if award
Optional Flatside Refo 6A
6 Flat 4,920 Hoedad or shovel
Base Flatside Refo 9A
12"
10/***
Rigid Mesh Tube
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
4/
Rigid Mesh Tube
Rigid Mesh Tube
3/
3/ No4/
4/
3/ No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5
10" Rigid Mesh Tube
10"
4/
4/
4/
4/
4/ 12" 3/
BFR Supplemental Planting Specifications Detailed Unit Info Sheet
Base Flatside Refo 5
5 Flat 4,840 Hoedad or shovel
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 Base
Flatside Refo 10A
8 Flat 5,120 Hoedad or shovel 12"
11 Flat 5,120 Hoedad or shovel 12"
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
10" Rigid Mesh Tube
Base Flatside Refo 4A
41 Flat 4,800 Hoedad or shovel
12" 3/ No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 Base
Flatside Refo 2A
4 Flat 4,960 Hoedad or shovel
Base Flatside Refo 3A
52 Flat 4,800
10" Rigid Mesh Tube
Base BOX 9 235 Flat 4,800 Hoedad or shovel
12" 3/ No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 Base
Oldwood 1B
2 Flat 4,240 Hoedad or shovel
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube
Hoedad or shovel
12" 3/ 4/ No
12" 3/ No
Base Flatside Refo 1A
Rigid Mesh Tube
AWARD UNIT
NAME
AND
NUMBER
ACRES ASPECT
AND
SLOPE %
ELEV.
(FEET)
REQUIRED
PLANTING
METHOD
1/
AVERAGE
PLANTING
SPACING
(FEET)
PLANTING SITE PREPARATION
No
REMARKS
7/
SPECIES &
STOCK
TYPE TO BE
PLANTED
8/ ROOT
LENGTH
(INCH)
9/
TYPE OF
SEEDLING
PROTECTION
REQUIRED
2/ SCALPING
6/
SPECIES
& SIZE OF
SUITABLE
EXISTING
TREES
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10" Rigid Mesh
Tube
4/ 3/12" Hoedad or shovel 4,320 Flat42
Rosland
Base
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Flat 4,960 Hoedad or shovel 12" 3/
1240BE26Q0020
Deschutes NF, Bend Fort Rock Sisters RD’s
DIAMETER
(INCHES)
DEPTH
(INCHES)
PLACEMENT DIAMETER
(INCHES)
20' x 20'
Microsite Emphasis
20' x 20' Microsite Emphasis
15' x 15' Microsite Emphasis
15' x 15' Microsite Emphasis
15' x 15' Microsite Emphasis
10" Rigid Mesh Tube if award
Optional Flatside Refo 8
2 Flat 5,040 Hoedad or shovel 12" 3/ 4/ No
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Rigid Mesh Tube if award
Optional Flatside Refo 7A
2 Flat 5,040 Hoedad or shovel 12" 3/ 4/ No
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Rigid Mesh Tube if award
No Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Rigid Mesh Tube if award
Suitable existing PP
PP
Bareroot Q-
Plug + 1.5 10"
Rigid Mesh Tube if award
Hoedad or shovel
12" 3/ 4/ No
Optional DAR 5 12 Flat 4,280
Optional DAR 6 3 Flat 4,280
No4/ 3/12" Hoedad or shovel
Optional DAR 4 18 Flat 4,280 Hoedad or shovel 12" 3/ 4/
REQUIRED
PLANTING
METHOD
1/
AVERAGE
PLANTING
SPACING
(FEET)
PLANTING SITE PREPARATION 6/
SPECIES
& SIZE OF
SUITABLE
EXISTING
TREES
7/
SPECIES &
STOCK
TYPE TO BE
PLANTED
8/ ROOT
LENGTH
(INCH)
9/
TYPE OF
SEEDLING
PROTECTION
REQUIRED
2/ SCALPING
BFR Supplemental Planting Specifications Detailed Unit Info Sheet
AWARD UNIT
NAME
AND
NUMBER
ACRES ASPECT
AND
SLOPE %
ELEV.
(FEET) REMARKS
1/ Where acceptable exisiting trees are ≥6 inches in height, average spacing shall be from the dripline of such trees instead of from the bole. Seedlings shall be planted to the boundary of all planting areas and around the perimeter of unplantable areas in spots distributed at intervals prescribed. For individual seedlings, the specified average spacing may be varied no more than 20 percent in any direction to find a suitable planting spot including emphasis on microsite planting. See Exhibit B for microsite emphasis.
2/ Clearing of surface materials shall be sufficient to make the size of scalp specified. 12 inch diameter scalp is required for planting holes.
3/ Depth of planting hole shall be deep enough to expose moist mineral soils and sufficient room for roots to be set straight, but not too deep when packing in planting hole to avoid air pockets. Aim for 10-12 inches.
4/ Stem of planted trees shall be no closer than 5 inches to the edge of the planting hole scalp where 12-inch diameter hand scalp is required.
5/ If awarded, all live vegetation within a 36 inch diameter area of the planted seedlings shall be grubbed. For shrubs and unsuitable seedlings, all of the plant above the root crown shall be removed. The root crown and roots of grasses and sedges shall be removed to a minimum depth of 3 inches below the soil surface.
6/ Suitable existing trees are ponderosa pines ≥6" height and free of top leader (apical meristem) damage, forks, or disease, and have a live crown ratio >= 40%. Ignore all other conifer species.
7/ PP = ponderosa pine, Bareroot Q-Plug +1.5 / Container
8/ Root length is measured from the cotyledon scar to end of longest root when held suspended by the stem in a natural position. Length may vary +/- 1.5 inches from length specified.
9/ Rigid mesh tube caging work will only be required on current year's planted trees.
10/ *** Refer to Seedling Trial Specifications and map attachment for planting instruction.
1240BE26Q0020
Deschutes NF, Bend Fort Rock Sisters RD’s
GRUBBING
DEPTH DIAMETER
(INCHES)
LOCATION DIAMETER
17,848
15' x 15'
Microsite Emphasis
2,910 15' x 15'
3,880 15' x 15'
Microsite Emphasis
8,730
15' x 15'
Microsite Emphasis
17,654
15' x 15'
Microsite Emphasis
2,716 15' x 15'
Microsite Emphasis
Optional Unit 13 14 S, 8% 4000
PP + DF +
Larch
Container Stock
10"
Rigid Mesh Tube if award
Access from
1000/700 road
Hoedad or shovel
3/ 12 4/ 5/
Rigid Mesh Tube
Access from
1040/320 road
Hoedad or shovel
3/ 12 4/ 5/
Rigid Mesh Tube
Access from
1040/320 road
5/
PP + DF +
Larch
Container Stock
10"Base Unit 16 91 NE, 15% 4900
Hoedad or shovel
3/ 12 4/Base Unit 14 45 NE, 10% 4800
PP + DF +
Larch
Container Stock
Rigid Mesh Tube
Access from HWY
PP + DF +
Larch
Container Stock
10"
PP + DF +
Larch
Container Stock
10"
Hoedad or shovel
3/ 12 4/ 5/ No Power equipment Base Unit 12 20 W, 5% 4200
3/ 12 4/ 5/
10" Rigid Mesh Tube
Access from
1000/700 road
Base Unit 4 15 NE, 15% 4100 Hoedad or shovel
3/ 12 4/ 5/
PP + DF +
Larch
Container Stock
Base Unit 3 92 E, 17% 4100 Hoedad or shovel
10" Rigid Mesh Tube
Access from 1040 road Microsite Emphasis
6/
SPECIES &
STOCK
TYPE
Sisters Supplemental Planting Specifications Detailed Info Sheet
AWARD
UNIT
NAME
AND
NUMBER
ACRES
ASPECT
AND
SLOPE %
ELEV.
(FEET)
PLANTING
METHOD
1/ Number of trees to plant
PLANTING SITE PREPARATION 7/
ROOT
LENGTH
(INCH)
8/
SEEDLING
PROTECT-
ION
REMARKS
2/ SCALPING
1240BE26Q0020
Deschutes NF, Bend Fort Rock Sisters RD’s
GRUBBING
DEPTH DIAMETER
(INCHES)
LOCATION DIAMETER
1,358
15' x 15'
Microsite Emphasis
Unit 7 7 E, 15% 4300Optional
Sisters Supplemental Planting Specifications Detailed Info Sheet
AWARD
UNIT
NAME
AND
NUMBER
ACRES
ASPECT
AND
SLOPE %
ELEV.
(FEET)
PLANTING
METHOD
1/ Number of trees to plant
PLANTING SITE PREPARATION 6/
SPECIES &
STOCK
TYPE
7/
ROOT
LENGTH
(INCH)
8/
SEEDLING
PROTECT-
ION
REMARKS
2/ SCALPING
PP + DF +
Larch
Container Stock
10" Rigid Mesh Tube
Access from
1000/700 road
Hoedad or shovel
3/ 12 4/ 5/
1/ Seedlings shall be planted to the boundary of all planting areas and around the perimeter of unplantable areas in spots distributed at intervals prescribed. Do NOT space off Existing Suitable Trees: A planted or naturally existing tree at least 6 inches in height of good form and vigor which shows no physical damage, and which conforms to the size, characteristics, and species. For individual seedlings, the specified average spacing may be varied no more than 20 percent in any direction to find a suitable planting spot including emphasis on microsite planting. See Exhibit B for microsite emphasis.
2/ Clearing of surface materials shall be sufficient to make the size of scalp specified (12 inches).
3/ Depth of planting hole shall be deep enough to expose moist mineral soils, have sufficient room for up to the first whorl of the seedling will be buried and the roots to be set straight. However, not to the depth where air pockets occur.
4/ Stem of planted trees shall be no closer than 5 inches to the edge of the planting hole scalp where 12-inch diameter hand scalp is required Microsite emphasis.
5/ If awarded, all live vegetation within a 36-inch diameter area of the planted seedlings shall be grubbed. For shrubs and unsuitable seedlings, all of the plant above the root crown shall be removed. The root crown and roots of grasses and sedges shall be removed between 2-4 inches below the soil surface. No Power equipment shall be used for Grubbing in Unit 12.
6/ PP = ponderosa pine, bareroot stock. DF = Douglas-fir.
7/ Root length is measured from the cotyledon scar to end of longest root when held suspended by the stem in a natural position.
Length may vary +/- 1.5 inches from length specified.
8/ Installing Rigid Mesh Tubes will only be required on current year's planted trees.
1240BE26Q0020
Deschutes NF, Bend Fort Rock Sisters RD’s
BFR