This document is an Asbestos Survey Results report for a demolition project located at 57600 McKenzie Hwy, McKenzie Bridge, Oregon, prepared for the United States Forest Service. The survey was conducted by Alpine Abatement Associates on 8/29/2025, with Seth Webb as the certified AHERA inspector. The 15,445 square foot commercial firefighting warehouse, built in 1990, was thoroughly inspected for potential asbestos-containing materials (ACM) using sampling protocols from the Asbestos Hazard Emergency Response Act.

The laboratory analysis by Atlas Labs found no asbestos-containing materials in any of the samples collected from various areas including the conference room, locker room, NW office, engine bay, office hallway, exterior, fire workplace, engine bay storage, and stairs. The report recommends contacting a licensed abatement contractor or the Oregon Department of Environmental Quality for further guidance, and emphasizes that a copy of the survey must be kept onsite during any remediation, renovation, or demolition activities. The TCLP analysis performed by SanAir Technologies also confirmed no significant levels of hazardous metals in the debris samples.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

- Asbestos Survey Results

DEMOLITION ASBESTOS SURVEY

DATE: 9/8/2025

JOBSITE LOCATION: 57600 McKenzie Hwy, McKenzie Bridge, OR 97413

SURVEY PREPARED FOR: Kenny Gabriel, United States Forest Service

PHONE NUMBER: 541-915-2598

SURVEY PERFORMED BY: Seth Webb

Certificate #IRO-25-4665C, Expires: 05/01/2025

Alpine Abatement Associates

PO Box 1557 Bend OR 97709

541-388-2672 service@alpineabatement.com

PROJECT NUMBER: O2827

Purpose for Survey

This survey was requested by the said customer to fulfill applicable regulatory compliance both in the

State of Oregon and on a Federal level.

Discussion of Findings

Asbestos Containing Materials:

The EPA, Oregon DEQ, and Oregon-OSHA define ACM as "any material containing more than one percent asbestos". Oregon-OSHA has adopted federal regulation governing asbestos (29 CFR Part

1926.1101). These regulations address work procedures and how asbestos-containing materials are removed. Hazard communication, training, personal protection, work practices, exposure monitoring, and recordkeeping are all major components of the regulation.

Reference documents for the removal of asbestos-containing materials include the following:

1. Oregon Occupational Safety and Health Administration (OAR-437, 1926.1101 Asbestos)

2. Department of Environmental Quality (OAR-340, Division 248)

3. OSHA (OAR 437-003-1926.1101) for projects <1%

Sample ID:

N/A: Accredited Asbestos Abatement Company to follow OAR-340, Division 248 standards

Special Terms & Conditions

No prior inspection by Alpine Abatement Associates Inc. has been performed on the property and all owner specified investigations are to be conducted at the time of the initial survey. A minimum number of samples were taken to ensure full accounting of potential ACM, while keeping sampling and analysis costs at an acceptable level to owner.

Detailed Description of Limitation and Thoroughness of Survey

Asbestos surveys are non-comprehensive by nature and subject to many limitations including those presented. This report applies only to the specific subject property, location and area detailed above.

While areas specified by the customer were surveyed and materials sampled, areas behind walls and/or covered by structural members, or materials requiring destructive means to access which could not be found with reasonable diligence were not sampled during the survey. There can be hidden crawl spaces and cavities that were not surveyed. Any areas not specified to be surveyed cannot be assumed to be free of asbestos as no survey was performed to determine the presence of asbestos-containing materials in these areas. This survey report is not intended for use as an asbestos abatement plan, specifications of work scope, or management of risks associated with asbestos. No part of this survey is intended to be used as renovation, addition or demolition plans and specifications.

Sampling Methodology

This survey was performed using sampling protocols adopted from the Asbestos Hazard Emergency

Response Act (AHERA) and modified to meet modified to meet Oregon DEQ asbestos survey and report requirements found in OAR 340-248-0270.

- Areas in the structure were grouped into homogeneous areas based on use or sameness of building materials used in that area; e.g. wall texture, etc.

- Each specified area was sampled for those materials which were identified as suspect ACM.

- When sampling, all samples were collected to the maximum extent possible (taken to substrate) to ensure all components were present in sample which might include asbestos.

- A minimum of one (1) bulk sample for each homogeneous material suspected of being asbestos-containing material was collected. OAR 340-248-0270(3)(a)

- A minimum of three (3) random bulk samples for each homogeneous sprayed or troweled on material were collected. OAR 340-248-0270(3)b)

- Samples were numbered using sequential numbering system to ensure quality control and replication of results for further surveys if needed during demolition of structure.

- Analysis of samples was performed by a laboratory that participates in a nationally recognized accreditation program for asbestos testing, or participates in, and maintains passing status in a nationally recognized bulk sample asbestos proficiency testing program. OAR 340-248-

0270(3)(c)

Jobsite Information

1. Date Performed: 8/29/2025

2. Address: 57600 McKenzie Hwy, McKenzie Bridge, OR 97413

3. Description of Facility: Commercial

4. Current or Past Use of Facility: Commercial

5. Area(s) Square Footage or Linear Footage: 15,445 SF

6. Approximate Construction Date: 1990

7. Number of Floors: Two

8. Purpose of Testing or Survey: Demolition

9. All location(s) at the address where the survey was performed: Firefighting Warehouse

10. All areas surveyed: Conference room, locker room, NW office, engine bay, office hallway, exterior, fire workplace, engine bay storage, stairs

11. Asbestos Containing Building Material Identified During Survey: None detected

12. A complete copy of the lab report for all samples analyzed: See attached

a. Laboratory name, address, and phone number

b. Unique sample analysis ID number

c. Bulk sample analysis results showing asbestos content

d. Name of the analyst

e. Completed chain of custody for the samples

13. Recommended Response Plan: Contact a Licensed Abatement Contractor or OREGON DEQ. The

Oregon Department of Environmental Quality regulates the handling, removal and disposal of asbestos-containing material to protect public health and the environment.

https://www.oregon.gov/deq/Hazards-and-Cleanup/Pages/Asbestos-Information.aspx

14. A copy of this survey report must be kept onsite during any remediation, renovation or demolition activities, as required by Oregon DEQ OAR 340-248-0270(2).

https://www.oregon.gov/deq/Hazards-and-Cleanup/Pages/Asbestos-Information.aspx

Accredited Inspector Information

15. Phone Number: 541-388-2672

16. Certificate Number: IRO-25-4665C

17. Copy of Certificate: See attached

Batch # 2022 * Name / Company *

519401 Alpine Abatement Associates

Analysis Date * Project Name

08/29/2025

Project # PO #

#02827

Analyst * Project Location *

Jason Elbon 57600 McKenzie Bridge Hwy, McKenzie Bridge, OR 97413

Turnaround Time *

2-Day

Asbestos Analysis of Bulk Material by Polarized Light Microscopy

Sample* Layer

Description* Non Asbestos*

Asbestos Type*

Asbestos

A-1 1 Drywall Debris (White / Burnt) - Conference Room

Cellulose None Present N/D

A-1 2 Insulation (White) - Conference Room Cellulose / Fiberglass

None Present N/D

A-2 1 Vinyl (Brown / Burnt) - Conference Room

Cellulose None Present N/D

A-2 2 Pad (Black) - Conference Room Cellulose None Present N/D

A-3 1 Drywall Debris (Burnt) - Locker Room Cellulose None Present N/D

A-4 1 Drywall Debris (White / Burnt) - NW Office

Cellulose None Present N/D

A-4 2 Texture (Burnt) - NW Office Cellulose None Present N/D

A-5 1 Drywall Debris (Burnt) - Engine Bay Cellulose None Present N/D

A-5 2 Insulation (White) - Engine Bay Cellulose / Fiberglass

None Present N/D

A-6 1 Drywall Debris (White / Burnt) - Office Hallway

Cellulose None Present N/D

A-6 2 Texture (Burnt) - Office Hallway Cellulose None Present N/D

A-7 1 Debris (Burnt) - NE Exterior Cellulose None Present N/D

Sample* Layer

Description* Non Asbestos*

Asbestos Type*

Asbestos

A-8 1 Debris (Burnt) - Fire Work Place Cellulose None Present N/D

A-9 1 Debris (Burnt) - Engine Bay Storage Cellulose None Present N/D

A-10 1 Debris (Burnt) - Stairs Cellulose None Present N/D

To Be Filled by the Technician

Technician *

Atlas Laboratories maintains liability to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full without written permission by Atlas. Atlas bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST, NIOSH or any other agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore Atlas recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Transmission Electron Microscopy asbestos identification and lead paint analysis will be available and performed by laboratories by proxy. Original analysis documents are available upon request of the client.

Analyst: Douglass, Vincent

Test Method: EPA 1311/6010C/7470A

TCLP Analysis Results in

Sample Description Analyte mg/L MRL (mg/L)

25058145 - 1 B-1 / Debris - Throughout Silver (Ag) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Arsenic (As) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Barium (Ba) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Cadmium (Cd) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Chromium (Cr) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Lead (Pb) < 0.5 < 0.5

25058145 - 1 B-1 / Debris - Throughout Mercury (Hg) < 0.002 < 0.002

25058145 - 1 B-1 / Debris - Throughout Selenium (Se) < 0.5 < 0.5

Signature:

Date: 9/4/2025 Date: 9/4/2025

Reviewed:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com

57600 McKenzieProject Number:

P.O. Number:

Project Name: Alpine Abatement Associates - #02827

8/29/2025Collected Date:

9/2/2025 9:50:00 AMReceived Date:

9/4/2025 2:44:25 PM

25058145

SanAir ID Number

FINAL REPORT

Atlas Laboratories, Inc - ORName:

Address: 14795 SW 72nd Ave, Ste B.

Portland, OR 97224

503-385-8848Phone:

AHERA INSPECTOR CERTIFICATE