CSID Product Sheet - Gen I.pdf

PDF 344 KB Posted

Attached to
Sanitization Systems Federal contract opportunity
Solicitation number
12305B24Q0159
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Northeast Area

About this file

This document contains a Product Sheet for the CSI-D+ Contamination, Sanitization Inspection and Disinfection system manufactured by SafetySpect, Inc. and a related Federal Contract Opportunity solicitation from the United States Department of Agriculture (USDA) Agricultural Research Service (ARS) for a handheld contamination, sanitization inspection, and disinfection system.

The Product Sheet describes the key features of the CSI-D+ system, including its ability to detect and disinfect various types of contaminants using UV-C and violet wavelengths. It provides technical specifications such as dimensions, power source, and safety standards. The Federal Contract Opportunity solicitation, Solicitation Number 12305B24Q0159, seeks a contractor to provide a system meeting the salient characteristics described in the attached specifications. This is a 100% small business set-aside with an NAICS code of 334516 and a size standard of 1,000 employees. Quotes are due by 8/19/2024 at 2:00 PM PST and must demonstrate the ability to meet or exceed the technical requirements. Award will be made on a Lowest Priced Technically Acceptable (LPTA) basis.

View the file

Other files for this federal contract opportunity

Other files attached to Sanitization Systems, newest first.
File Type Posted
CSI Product Sheet - Gen I.pdf PDF
Questions and Answers for SAM.docx DOCX document
Contract Terms and Conditions.docx DOCX document
Specifications.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Confidential - SafetySpect, Inc Page 1 of 3

Product Name: CSI-D+ Contamination, Sanitization Inspection and Disinfection system

Model: SS-CSID-01 Manufacturer: SafetySpect, Inc Origin: Invented, Developed, and Assembled in the USA, Patent Pending [1]

EPA Registration Number 85548-ND-001 EPA Establishment Number 98766-CA-1

FEATURES:

1. CSID+: detection achieved through UVC (275nm) and violet (405nm) wavelengths.

2. CSI: detection achieved through UVA (365nm) and violet (405nm) wavelengths.

3. Creates UV-C irradiation of 7.6 mW/cm2 at 5” distance (CSID+).

4. Produces no ozone or other secondary contaminants.

5. High-quality LED illumination design for a long lifespan and no mercury.

6. Portable, versatile, and easy.

7. Use on products and equipment where chemicals and liquids can’t be used.

8. Dimensions: 11.4” x 8.2” x 7.9” (290cm x 209cm x 201cm)

9. Wireless Communication: Wi-Fi 801.11ac

How the technology works:

The CSI Imaging Device allows cleaning auditors to quickly, safely, and easily visualize and document potentially harmful contamination residue presence af ter cleaning on high-touch and high-risk surfaces in real-time. The f luorescence imaging scanner is non-contact, and no f luorescent dyes or reagents are required for operation.

Examples of invisible organic residues include saliva and respiratory droplets [2], vegetable and grain starch [2], leafy vegetable residue [2], fecal matter contamination [3], fats and oils, and animal protein residue. The CSI scanner is an EPA-registered device comprised of a high-resolution color LCD display and touch-sensitive screen with integrated optical and microelectronic components. The handheld scanner is battery-operated and rechargeable and incorporates illumination, imaging, battery power, display, and processing units in a single system.

A unique capability of CSID+ is to provide immediate spot disinfection using the UV-C germicidal ef fect when residual contamination is discovered during audits. Our in vitro studies show that CSI-D+ completely neutralizes residual viruses, bacteria, and fungi in seconds (Inf luenza A, Streptococcus pneumoniae, Escherichia coli, Listeria monocytogenes, Salmonella, Aspergillus fumigatus) [2,4].

The CSI scanner uses its patented technology to enable real-time standard light and f luorescence imaging of residue on contaminated surfaces under normal indoor ambient light conditions. The CSI technology captures real-time images (JPEG) and videos (MP4) in both standard imaging and f luorescence imaging.

Confidential - SafetySpect, Inc Page 2 of 3

UV Source / Intensity

• 275nm high Power LEDs

• Built-in safety mechanisms, including auto-shutof f based on distance, orientation, and dual trigger system.

Optical System

Camera Lens Filter

RGB Camera (Top) Alvium 1500 C-120 Allied Vision lens s-4.1-

F3-5MP-T1-2.5

Omega Dual bandpass f ilter 535-

700DBEM/14MM

UV Camera (Central) EHD SCM2020-UV UV Lens 9mm F/2.8 -

Wide UV Lens

EO Techspec

Bandpass Filter 350/50nm

Power

• Battery- 3.7 V, 5.0 Ah Li-Ion Rechargeable via a docking station.

• Removable, of f -the-shelf , Milwaukee Tool model 50-11-1850 M18™ 5.0Ah Battery.

Example Measured UV irradiance distribution

Ingress / Water protection.

• There is no IP rating for the system

Safety Standards The following safety standards are planned for CSI-D+:

• UL 61010-1 Safety Requirements for Electrical Equipment for

Measurement, Control, and Laboratory Use - Part 1: General

Requirements (Ed. 3)

• UL 2900-1 ANSI/CAN/UL Standard for Sof tware Cybersecurity for Network-Connectable Products, Part1: General

Requirements

• UL 8750 Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products (Ed. 2)

• UL 2595 General Requirements for Battery-Powered Appliances (Ed. 3)

• ANSI/IES RP-27.1-15 Recommended Practice For Photobiological Safety For Lamps And Lamp Systems -

General Requirements

• ISO 15858:2016(en) UV-C Devices — Safety information — Permissible human exposure

Quality Standards The following quality standards are planned for CSI-D+:

• Food and Drug Administration Federal Register 21 CFR 820 "Quality System Regulation."

• International Standard for Organization "Medical devices - Quality management systems - Requirements for regulatory purposes" ISO 13485:2016.

PRECAUTIONS for the end user:

The CSI-D+ system is a Class 3 UV illumination hazard. The operator should avoid direct skin and eye contact with UV light. Protective eyewear and skin protection are required when using the CSI-D+ Unit.

5.0

5.1

4.7

4.64.5

4.5

6.9

6.9

4.7 7.1

4.9

6.8

6.8

7.6 7.2

7.2

6.9

CSi-D+ Irradiance at 5” Distance

Target Size: 2R(0): 5” (127mm) Target Distance: 5” (127mm)

Units mW/cm2

Confidential - SafetySpect, Inc Page 3 of 3

References:

1. Vasef i, Fartash; Barton, Kenneth Edward; MacKinnon, Nicholas Bennett; Carroll, David; Marinkovich, Sava; Inspection and sanitation device and method 2021, US Patent App. 17/161,567

2. Sueker, Mitchell; Stromsodt, Kristen; Gorji, Hamed Taheri; Vasef i, Fartash; Khan, Nadeem; Schmit, Taylor; Varma, Rangati; Mackinnon, Nicholas; Sokolov, Stanislav; Akhbardeh, Alireza; Handheld multispectral f luorescence imaging system to detect and disinfect surface contamination, Sensors, 21 21

7222, 2021, MDPI

3. Gorji, Hamed Taheri; Shahabi, Seyed Mojtaba; Sharma, Akshay; Tande, Lucas Q; Husarik, Kaylee; Qin, Jianwei; Chan, Diane E; Baek, Insuck; Kim, Moon S; MacKinnon, Nicholas; Combining deep learning and f luorescence imaging to automatically identify fecal contamination on meat carcasses, Scientif ic Reports, 12 1, 11-Jan 2022, Nature Publishing Group

4. Gorji, Hamed Taheri; Van Kessel, Jo Ann; Husarik, Kaylee; Shahabi, Seyed Mojtaba; Zadeh, Hossein

Kashani; Chan, Diane E.; Qin, Jianwei; Baek, Insuck; Kim, Moon S.; Akhbardeh, Alireza; Sohrabi, Mona;

Kerge, Brick; Vasef i, Fartash; MacKinnon, Nicholas; Tavakolian, Kouhyar; Deep Learning and Multiwavelength Fluorescence Imaging for Cleanliness Assessment and Disinfection in Food Services, Frontiers in Sensors, Submitted

File details come from the government source that posted it. Updated .