This is an asbestos survey and assessment report prepared by Air Quality Consulting, LLC for Granite School District regarding Portable 2113 at West Kearns Elementary School located at 4895 S 4720 W, Kearns, Utah 84118. The survey was conducted on June 8, 2026, with laboratory analysis completed by Eurofins Reservoirs in Denver, Colorado, and finalized on June 10, 2026. The scope of work involved comprehensive sampling and testing of building materials across the portable structure in preparation for its pending demolition. Ten bulk samples were collected from various homogeneous areas including cove base, vinyl flooring, ceiling panels, drywall systems, and yellow mastic materials, with a total surveyed area encompassing approximately 8,625 square feet across both the South and North classrooms.
The laboratory analysis results indicate that asbestos-containing material (ACM) was not detected in any of the bulk samples tested. All samples returned non-detect (ND) results for asbestos content. The testing was conducted in accordance with appropriate methodologies using Transmission Electron Microscopy (TEM), Polarized Light Microscopy (PLM), and Phase Contrast Microscopy (PCM) analysis by an accredited laboratory holding certifications from the National Voluntary Laboratory Accreditation Program (NVLAP) and the American Industrial Hygiene Association (AIHA LAP). The findings confirm that the portable structure contains no regulated asbestos materials, clearing the path for demolition to proceed without asbestos abatement requirements.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
226 East 4800 South Murray, Utah 84107
AN ASBESTOS SURVEY AND ASSESSMENT FOR
Granite School District West Kearns Elementary Portable 2113
4895 S 4720 W Kearns, UT, 84118
10 June, 2026
Prepared by:
Scott Bainbridge #ASB-6822 Preston Bainbridge #ASB-8870
Jaden Ford #ASB-8971 Air Quality Consulting, LLC #603
385-321-9701 scott@aqc.solutions http://scott@aqc.solutions/
Scope of Work
We were hired by Granite School District to survey Portable 2113 at West Kearns Elementary for a pending demolition of the entire portable. Samples were taken by Jaden Ford on 8 June, 2026, and tested at Eurofins Reservoirs in Denver, Colorado. The results are included in this report.
Executive Summary
Asbestos-containing material (ACM) was not found in any bulk samples.
*- Denotes less than 1% asbestos which is regulatedby OSHA, it is recommended to review their regulations before removal
Building Description
Structure: Wood or Metal Framed
Roof: Metal
Siding: Metal
Foundation: None
Insulation: None
Walls: Paneling, Drywall
Ceiling: Ceiling Panel
Flooring: Vinyl Tile, Carpet
Non-ACM Results by Material
Sample Number
Material Description
Amount Sample Location
Homogeneous Area
Lab Results Category
Cove Base
P2113-6826-1 4" Gray Cove Base
25 SF South Classroom Baseboards ND ND
P2113-6826-2 4" Gray Cove Base
25 SF North Classroom Baseboards ND ND photo photo photo
Vinyl Flooring
P2113-6826-3 Vinyl Flooring 925 SF South Classroom Non Carpet Floors ND ND
P2113-6826-4 Vinyl Flooring 925 SF North Classroom Non Carpet Floors ND ND photo photo photo
Ceiling Panel
P2113-6826-5 2'x4' Wormhole Ceiling Panel
1,850 SF South Classroom Ceilings ND ND
P2113-6826-6 2'x4' Wormhole Ceiling Panel
1,850 SF North Classroom Ceilings ND ND photo photo photo
Drywall System
P2113-6826-7 Drywall System
4,000 SF South Classroom Throughout ND ND
P2113-6826-8 Drywall System
4,000 SF North Classroom Throughout ND ND
Yellow Mastic
P2113-6826-9 Yellow Mastic 925 SF South Classroom Under Carpet ND ND
P2113-6826-10 Yellow Mastic 925 SF North Classroom Under Carpet ND ND
June 09, 2026
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 757228-1
Project #/P.O. #: P2113-6826
Project Description: West Kearns Portable 2113
Jaden Ford Air Quality Consulting, LLC 226 E 4800 S Murray, UT 84107
Dear Jaden, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 757228-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer (i.e. sample volumes and areas). This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
06/09/202606/09/202606/09/202606/09/2026
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 757228 -757228 -757228 -757228 - P2113-6826-1P2113-6826-1P2113-6826-1P2113-6826-1 A Gray cove base 100 NDNDNDND 0 100.0 757228 -757228 -757228 -757228 - P2113-6826-2P2113-6826-2P2113-6826-2P2113-6826-2 A Cream adhesive 1 NDNDNDND 0 100.0 B Gray cove base 99 NDNDNDND 0 100.0 757228 -757228 -757228 -757228 - P2113-6826-3P2113-6826-3P2113-6826-3P2113-6826-3 A Gray leveling compound w/ colorless adhesive 10 NDNDNDND 0 100.0 B Gray/multi-colored flooring w/ clear adhesive 90 NDNDNDND 0 100.0 757228 -757228 -757228 -757228 - P2113-6826-4P2113-6826-4P2113-6826-4P2113-6826-4 A Yellow adhesive 1 NDNDNDND 0 100.0 B Off-white floor tile 35 NDNDNDND 0 100.0 C Gray/multi-colored flooring w/ clear adhesive 64 NDNDNDND 0 100.0 757228 -757228 -757228 -757228 - P2113-6826-5P2113-6826-5P2113-6826-5P2113-6826-5 A Gray/white ceiling tile 100 NDNDNDND 80 20.0 757228 -757228 -757228 -757228 - P2113-6826-6P2113-6826-6P2113-6826-6P2113-6826-6 A Gray/white ceiling tile 100 NDNDNDND 80 20.0 757228 -757228 -757228 -757228 - P2113-6826-7P2113-6826-7P2113-6826-7P2113-6826-7 A White/tan drywall w/ purple/white resinous material 100 NDNDNDND 20 80.0 757228 -757228 -757228 -757228 - P2113-6826-8P2113-6826-8P2113-6826-8P2113-6826-8 A Tan resinous material 2 NDNDNDND 0 100.0 B White/tan drywall w/ white resinous material 98 NDNDNDND 20 80.0 757228 -757228 -757228 -757228 - P2113-6826-9P2113-6826-9P2113-6826-9P2113-6826-9 A Yellow/green adhesive 100 NDNDNDND 0 100.0 757228 -757228 -757228 -757228 - P2113-6826-10P2113-6826-10P2113-6826-10P2113-6826-10 A Green/yellow adhesive 100 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Christina Tiggemann Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
757228-1 Air Quality Consulting, LLC P2113-6826 West Kearns Portable 2113 June 09, 2026 EPA 600/R-93/116 - Short Report, Bulk Rush June 09, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 757228
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: Air Quality Consulting, LLC Company: Air Quality Consulting, LLC
Address: 226 E 4800 S Address: 226 E 4800 S
Murray, UT 84107 Murray, UT 84107
Project Number and/or P.O. #: P2113-6826 Project Zip Code:
Project Description/Location: West Kearns Portable 2113
Contact: Jaden Ford -1 PLM Rush *NO VERBALS* Phone: (385) 388-2614
Fax:
Cell: (385) 388-2614
Final Data Deliverable Email Address:
jaden@aqc.solutions (+ 2 ADDNL. CONTACTS)
PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 P2113-6826-1 X B 06/08/26 00:00
2 P2113-6826-2 X B 06/08/26 00:00
3 P2113-6826-3 X B 06/08/26 00:00
4 P2113-6826-4 X B 06/08/26 00:00
5 P2113-6826-5 X B 06/08/26 00:00
6 P2113-6826-6 X B 06/08/26 00:00
7 P2113-6826-7 X B 06/08/26 00:00
8 P2113-6826-8 X B 06/08/26 00:00
9 P2113-6826-9 X B 06/08/26 00:00
10 P2113-6826-10 X B 06/08/26 00:00
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
N Y
S
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.
Relinquished By:
Jaden Ford Date/Time: 06/08/2026 11:26:19 Sample Condition: Acceptable
Received By:
Emily Creasey Date/Time: 06/09/2026 10:37:17 Carrier: Fed-Ex
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
List of NESHAP Regulated Materials Tested and Found in Surveys
1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized or reduced to powder by hand pressure)
Tested Materials Positive ______ Thermal System Insulation (TSI) ________ ______ Textured Ceiling Materials (TCM) ________ ______ Spray-on Insulation or Fireproofing ________ ______ Blown-in Insulation ________ ______ Ceiling Tiles/Panels ________ ______ Plaster, Gypsum Board, Joint Compound ________ ______ Cloth Materials ________ ______ Paper Materials ________ ______ Electrical Wiring Insulation ________ ______ Sink Undercoating (loose) ________ ______ Other____________________________ ________
2. Category I ACM which has become friable
Tested Materials Positive ______ Packings ________ ______ Gaskets ________ ______ Vinyl Floor Tile and Sheet Vinyl Flooring ________ ______ Asphalt Roofing Products ________
3. Category I ACM that will be or has been subjected to sanding, grinding, cutting or abrading
Tested Materials Positive ______ Packings ________ ______ Gaskets ________ ______ Vinyl Floor Tile and Sheet Vinyl Flooring ________ ______ Asphalt Roofing Products ________
4. Category II ACM that has a high probability of becoming or has become friable in the course of demolition or renovation operations
Tested Materials Positive ______ Asbestos Cement Materials (transite) ________ ______ Asphalt, tar and rubber base ACM products other than roofing ________ ______ Non-asphalt and Non-paper Roofing Products ________ ______ Paint ________ ______ Fire Brick and/or Mortar ________ ______ Stainless Steel Sink Undercoating (solid) ________ ______ Encapsulated TCM ________ ______ Encapsulated TSI ________ ______ Mastic for Floor Tile, Ceiling Tile, Cove Molding, etc. ________
List of NESHAP Non-Regulated Materials Tested and Found in Survey
1. 1% Asbestos≤
2. Category I Non-Friable (cannot be crumbled, pulverized or reduced to powder by hand pressure) ACM with <1% asbestos by new PLM procedure
Tested Materials Positive ______ Packings ________ ______ Gaskets ________ ______ Vinyl Floor Tile and Sheet Vinyl Flooring ________ ______ Asphalt Roofing Products ________
3. Category II Non-Friable ACM with <1% asbestos by new PLM procedure (category includes items meeting Category I definition but not specifically listed in that category)
Tested Materials Positive ______ Asbestos Cement Materials (transite) ________ ______ Asphalt, tar and rubber base ACM products other than roofing ________ ______ Non-asphalt and Non-paper Roofing Products ________ ______ Paint ________ ______ Fire Brick and/or Mortar ________ ______ Stainless Steel Sink Undercoating (solid) ________ ______ Encapsulated TCM ________ ______ Encapsulated TSI ________ ______ Mastic for Floor Tile, Ceiling Tile, Cove Molding, etc. ________ ______ Other__________________________________ ________
Notes
1. All materials and conditions are interpreted by Air Quality Consulting LLC
2. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air Pollutants (NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature. Asbestos materials classified as “Non-Regulated” at the time of the survey may become “Regulated” due to ongoing or planned maintenance, renovation or demolition actions which can transform a material containing greater than 1% asbestos from a “non-friable” and “Non-Regulated” to a “friable” and “Regulated” condition. Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.
3. Maintenance, renovation, demolition, weathering, normal wear, water or other damage can alter the “Non-Regulated” status of materials, and necessitate precautions required for handling them as “Regulated” asbestos-materials.
4. Details on testing locations, methods and results can be found on the remaining report.
Asbestos Survey and Assessment Performed at West Kearns Elementary Portable 2113
4895 S 4720 W Kearns, UT, 84118
10 June, 2026
Methods and Materials
A survey of the areas was conducted to observe, identify, locate and sample any materials suspected of containing asbestos according to NESHAP categories. All accessible areas were identified and documented.
Bulk samples were collected using approved methods and microscopically analyzed for asbestos content by a lab that participates in the National Institute for Standards and Technology’s National Voluntary Laboratory Accreditation Program (NVLAP).
Asbestos percentages were estimated utilizing the polarized light microscope (PLM) and dispersion staining methods as prescribed by NIOSH.
10 June, 2026 Scott Bainbridge Date State of Utah Inspector #ASB-6822 exp. 9/18/26
10 June, 2026 Preston Bainbridge Date State of Utah Inspector #ASB-8870exp. 05/09/27
Jaden Ford 10 June, 2026
Jaden Ford Date State of Utah Inspector #ASB-8971exp. 12/10/26