11-4 - Plan Set.pdf
PDF 37 MB Posted
- Attached to
- 26B-103 SW Regional WRF O&M Improvements
- Solicitation number
- 26-103
- Issued by
- Marion County, Florida
About this file
This is a plan set document for Marion County Utilities in Belleview, Florida, detailing the Southwest Regional Water Reclamation Facility (WRF) Operations & Maintenance Improvements project. The project involves the installation of three new positive displacement blowers with associated electrical work, site preparation, instrumentation, and stormwater infrastructure improvements, along with the decommissioning of three existing blowers. The plan set, issued for bid in May 2026, comprises comprehensive civil, structural, mechanical, electrical, and instrumentation drawings prepared by Ardurra, Inc., with the facility located at 11800 SE US Highway 441, Belleview, Florida. The project includes modifications to the existing chlorine contact basin system, yard piping plans, grading and drainage infrastructure, and detailed equipment specifications across multiple discipline-specific sheets.
The plan set includes extensive technical specifications and design standards, including compliance with the 2023 Florida Building Code, ACI 318-19 for reinforced concrete, and AISC standards for structural steel. Key project components documented include process flow diagrams for aeration and secondary treatment systems, equipment pad details, pipe support specifications, and comprehensive electrical one-line diagrams for motor control centers. The drawings specify that Marion County has already procured the blowers to reduce lead time, with physical construction to commence upon blower delivery, though contractors may pursue required permits during the interim period. The project area encompasses approximately 30-foot buffer zones around the existing treatment facility, with detailed grading elevations, reinforcement schedules, and foundation requirements for new equipment installations throughout the site.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS
LOCATION MAP
FOR:
PROJECT
SITE
11800 SE US HWY 441
BELLEVIEW, FLORIDA 34420
352-707 4624
MARION COUNTY UTILITIES
NO. DATE REVISION BY
G-1
ISSUED FOR BID
MAY 2026
405 Golfway West Drive, Suite 201A St. Augustine, Florida 32095
Phone: (904) 593-5610 www.Ardurra.com
M ay
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-C V
-O M
.d w g
JOB NO: 2024-1306
ENGINEER OF
RECORD
FL PE #
VICINITY MAP
PROJECT
SITE
ISSUED FOR BID
BOARD OF COUNTY COMMISSIONERS
DISTRICT 1 CRAIG CURRY
DISTRICT 2 KATHY BRYANT
DISTRICT 3 MATT McCLAIN
DISTRICT 4 CARL ZALAK, III
DISTRICT 5 MECHELLE STONE
COUNTY ADMINISTRATOR
MOUNIR BOUYOUNES, P.E.
UTILITIES DIRECTOR
ANTHONY L. CUNNINGHAM, P.E.
SHEET
ATTENTION IS DIRECTED TO THE FACT THAT
THESE PLANS MAY HAVE BEEN REDUCED IN
SIZE BY REPRODUCTION. THIS MUST BE
CONSIDERED WHEN OBTAINING SCALED
DATA.
Utilities
SR 2
SW HWY 484
S W
5T
H C
IR
SW HWY 484
S W
95TH
C
IR
Know what'sbelow.
before you dig.Call
R
MARION COUNTY UTILITIES
SOUTHWEST REGIONAL WRF O&M IMPROVEMENTS
SECTION 35, TOWNSHIP 16S S, RANGE 20 E
MARION COUNTY, FLORIDA
AutoCAD SHX Text S.S.O.C.O.F. TICKET No. ????? DATE: MM/DD/YYYY
M ay
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-C V
-O M
.d w g
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
G-2
ISSUED FOR BID
MAY 2026
S H
E E
T
IN
D E
X
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E N
TS
O
D
A
TE
R E
V
IS
IO
N
B Y
JOB NO:
405 Golfway West Drive, Suite 201A St. Augustine, Florida 32095
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
Sheet List Table Sheet Number Sheet Title
GENERAL
G-1 O&M COVER SHEET
G-2 SHEET INDEX
G-3 GENERAL NOTES AND ABBREVIATIONS
G-4 LEGEND AND SYMBOLS
G-5 PROCESS FLOW DIAGRAM I
G-6 PROCESS FLOW DIAGRAM II
CIVIL
C-1 EXISTING SITE PLAN
C-2 SITE PLAN
C-3 GEOMETRY PLAN
C-4 YARD PIPING PLAN
C-5 GRADING AND DRAINAGE PLAN
STRUCTURAL
S-1 GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND AND SYMBOLS
S-2 MISCELLANEOUS SLABS
S-3 PIPE SUPPORT DETAILS & STANDARD DETAILS
MECHANICAL
M-1 EXISTING BLOWERS DEMOLITION PLAN
M-2 BLOWERS PLAN
M-3 BLOWER SECTION
M-4 EXISTING CHLORINE CONTACT BASIN DEMOLITION PLAN
M-5 EXISTING CHLORINE CONTACT BASIN MODIFICATIONS PLAN
MD-1 MISCELLANEOUS MECHANICAL DETAILS
ELECTRICAL
E-1 ELECTRICAL GENERAL NOTES
E-2 ELECTRICAL LEGEND
E-3 MCC-1 DEMOLITION ONE-LINE DIAGRAM
E-4 MCC-2 DEMOLITION ONE-LINE DIAGRAM
E-5 MCC-3 EXISTING ONE-LINE DIAGRAM
E-6 MCC-4 EXISTING ONE-LINE DIAGRAM
E-7 MCC-1 PROPOSED ONE-LINE DIAGRAM
E-8 MCC-2 PROPOSED ONE-LINE DIAGRAM
E-9 ELECTRICAL OVERALL SITE PLAN
E-10 ELECTRICAL OVERALL SITE LIGHTING
E-11 ELECTRICAL BLOWER DEMOLITION PLAN
E-12 ELECTRICAL BLOWER PROPOSED PLAN
E-13 ELECTRICAL CHLORINE CONTACT BASIN DEMOLITION PLAN
E-14 ELECTRICAL CHLORINE CONTACT BASIN PROPOSED PLAN
E-15 ELECTRICAL PANEL AND WIRING SCHEDULES I
E-16 ELECTRICAL PANEL SCHEDULES II
E-17 ELECTRICAL PANEL SCHEDULES III
INSTRUMENTATION
I-1 LEGENDS, SYMBOLS, AND ABBREVIATIONS I
I-2 LEGENDS, SYMBOLS, AND ABBREVIATIONS II
I-3 CONTROL BLOCK DIAGRAM
I-4 AERATION BLOWERS
I-5 CHLORINE CONTACT BASIN
I-6 INSTRUMENTATION DETAILS
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-C V
-O M
.d w g
A
B
C
D
E
F
G
H
G-3
MAY 2026
G E
N E
R A
L N
O
TE
S A
N D
A B
B R
E V
IA
TI
O N
S
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
GENERAL NOTES:
1. SPECIAL CARE SHALL BE TAKEN TO ENSURE THAT EXISTING TREES TO BE SAVED REMAIN
UNDAMAGED DURING CONSTRUCTION. REFERENCE LANDSCAPE AND LAND ALTERATION
ORDINANCE. DEVELOPMENT SHALL COMPLY WITH THE TREE AND LANDSCAPE CODES AS SET
FORTH IN THE LAND DEVELOPMENT CODE UNLESS PERMITTED OTHERWISE.
2. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL EXPOSE ALL EXISTING UTILITIES TO
BE EXTENDED OR CROSSED AND CONTACT THE ENGINEER FOR RESOLUTION OF ANY
CONFLICTS BETWEEN FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS.
3. DIGITAL OR ELECTRONIC REPRESENTATION OF THESE CONSTRUCTION PLANS DOES NOT
CONSTITUTE A COORDINATE CONTROL MAP OR MATHEMATICALLY CONTROLLED
INFORMATION FOR THE USE OF CONSTRUCTION STAKEOUT. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR AND/OR CONTRACTOR'S SURVEYOR TO ENSURE THAT ANY DIGITAL OR
ELECTRONIC REPRESENTATION OF THESE PLANS IS IN COMPLETE CONFORMANCE WITH ALL
OF THE NOTATIONS, SPECIFICATIONS, DETAILS AND OTHER DATA APPEARING ON OR AS
MAY BE DERIVED FROM THESE CONSTRUCTION PLANS.
4. CONTRACTOR IS RESPONSIBLE FOR PREPARING AND IMPLEMENTING MAINTENANCE OF
TRAFFIC PLANS AS REQUIRED.
5. CONTRACTOR RESPONSIBLE FOR REPAIR AND REPLACEMENT OF INFRASTRUCTURE /
FACILITIES WITHIN THE RIGHT-OF-WAY THAT ARE DAMAGED DURING CONSTRUCTION
ACTIVITY.
SANITARY SEWER AND WATER DISTRIBUTION NOTES:
1. NO DEBRIS SHALL BE ALLOWED TO ENTER THE EXISTING SANITARY SYSTEM.
2. SANITARY SEWERS, FORCE MAINS, AND STORM SEWERS SHOULD ALWAYS CROSS UNDER WATER
MAINS. SANITARY SEWERS, FORCE MAINS AND STORM SEWERS CROSSING WATER MAINS SHALL
BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18-INCHES BETWEEN THE INVERT OF
THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE WHENEVER POSSIBLE.
3. WHERE SANITARY SEWERS, FORCE MAINS AND STORM SEWERS MUST CROSS A WATER MAIN
WITH LESS THAN 18-INCHES VERTICAL DISTANCE, BOTH THE SEWER AND THE WATER MAIN
SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS IF IT IS NOT AVAILABLE IN THE SIZE PROPOSED.) SUFFICIENT LENGTHS OF
DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO
JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE LEAK
FREE, AND MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6-INCHES MUST
BE MAINTAINED AT THE CROSSING.
4. WHERE THERE IS NO ALTERNATIVE TO SEWER PIPES CROSSING OVER THE WATER MAIN, THE
CRITERIA FOR MINIMUM SEPARATION OF 18-INCHES BETWEEN LINES AND 10 FEET BETWEEN
JOINTS SHALL BE REQUIRED.
5. ALL CROSSINGS SHALL BE ARRANGED SO THAT THE SEWER PIPE JOINTS AND THE WATER MAIN
PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING (PIPES CENTERED ON THE
CROSSING). WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE, THE NEW PIPE SHALL BE
CONSTRUCTED OF DIP AND THE CROSSING SHALL BE ARRANGED TO MEET THE REQUIREMENTS
ABOVE.
6. A MINIMUM 10-FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN ANY TYPE OF
SEWER AND WATER MAIN IN PARALLEL INSTALLATIONS WHENEVER POSSIBLE.
7. IN CASES WHERE IT IS NOT POSSIBLE TO MAINTAIN A 10-FOOT HORIZONTAL SEPARATION, THE
WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF
LOCATED ON ONE SIDE OF THE SEWER OR FORCE MAIN AT SUCH AN ELEVATION THAT THE
BOTTOM OF THE WATER MAIN IS AT LEAST 18-INCHES ABOVE THE TOP OF THE SEWER.
8. WHERE IT IS NOT POSSIBLE TO MAINTAIN A VERTICAL DISTANCE OF 18-INCHES IN PARALLEL
INSTALLATIONS, THE WATER MAIN SHALL BE CONSTRUCTED OF DIP AND THE SEWER OR THE
FORCE MAIN SHALL BE CONSTRUCTED OF DIP (IF AVAILABLE IN THE SIZE PROPOSED) WITH A
MINIMUM VERTICAL DISTANCE OF 6-INCHES. THE WATER MAIN SHOULD ALWAYS BE ABOVE
THE SEWER. JOINTS ON THE WATER MAIN SHALL BE LOCATED AS FAR APART AS POSSIBLE FROM
JOINTS ON THE SEWER OR FORCE MAIN (STAGGERED JOINTS).
ABU ABUTMENT
AS ACTIVE SLUDGE
AL ALUM SOLUTION
AB ANCHOR BOLT
ADPT ADAPTER
ADJ ADJUSTMENT or ADJACENT
AC ACRES
AHD AHEAD
ARV AIR RELEASE VALVE
AKA ALSO KNOWN AS
AG ALLEY GRATE
ALUM ALUMINUM
APP APPARENT
APP'D APPROVED
APPROX APPROXIMATE
A ARC
ARCH ARCHITECTURAL or
ARCHITECT
AC ASBESTOS CEMENT
ASPH ASPHALT
ASSY ASSEMBLY
ATM ATMOSPHERE
AT AUGER TERMINATION DEPTH
AVE AVENUE
AWL AVERAGE WATER LEVEL
BK BACK
BFD BACK FLOW DEVICE
BOC BACK OF CURB
BOW BACK OF WALK
BV BALL VALVE
BW BACKWASH
BRCD BARRICADE
BL BASELINE
BRG BEARING
BM BENCH MARK
BIT BITUMINOUS
BF BLIND FLANGE
BO BLOW OFF
BK BOOK
BBCV BOTTOM BUFFER CHECK
VALVE
BC BOTTOM OF CURVE
BLVD BOULEVARD
BOXC BOX CULVERT
BRKT BRACKET
BLDG BUILDING
BE BURIED ELECTRIC
BT BURIED TELEPHONE
BFV BUTTERFLY VALVE
CATV CABLE TELEVISION
(C) CALCULATED
CI CAST IRON
CIP CAST IRON PIPE
CB CATCH BASIN
CAT CATALOG
CLKG CAULKING
CTR CENTER
CL CENTERLINE
CENT CENTRATE
CHKD CHECKERED
CV CHECK VALVE
CL2 CHLORINE
CL2S CHLORINE SOLUTION
CCC CHLORINE CONTACT
CHAMBER
CCP CHLORINE CONTACT POINT
CH CHORD
CIR CIRCLE
CEP CITY ELECTRIC POLE
CWM CITY WATER MAIN
CLW CLARIFIED WATER
CE CLARIFIER EFFLUENT
CO CLEAN OUT
CLR CLEAR OR CLEARANCE
COL COLUMN
CAV COMBINATION AIR/VACUUM
RELEASE VALVE
CA COMPRESSED AIR
CONC CONCRETE
CBS CONCRETE BLOCK STRUCTURE
CMU CONCRETE MASONRY UNIT
CM CONCRETE MONUMENT
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CTB COOLING TOWER BLOW DOWN
CTR COOLING TOWER RETURN
CNR CORNER
CORP CORPORATION
CORR CORRUGATED
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE
ARCH
C SNK COUNTERSINK
CR COUNTY ROAD
CPLG COUPLING
CF CUBIC FEET
CFM CUBIC FEET PER MINUTE
CY CUBIC YARD
CULV CULVERT
C&G CURB & GUTTER
C# CURVE NUMBER
C CUT
DEC DECANT
DB DEED BOOK
DEPT DEPARTMENT
DET DETAIL
DWS DEWATERED SOLIDS
DIA DIAMETER
DIM DIMENSION
DBI DITCH BOTTOM INLET
DPI DITCH POINT INTERSECTION
DBL DOUBLE
DN DOWN
DWG DRAWING
DR DRIVE
DW DRIVEWAY
DWA DRIVEWAY ASPHALT
DWB DRIVEWAY BRICK
DWC DRIVEWAY CONCRETE
DWD DRIVEWAY DIRT
DWGS DRIVEWAY GRASS
DWGR DRIVEWAY GRAVEL
DI DUCTILE IRON
DIP DUCTILE IRON PIPE
EA EACH
EW EACH WAY
EASMT EASEMENT
E EAST OR EASTING
E-W EAST - WEST
ECC ECCENTRIC
EOP or EP EDGE OF PAVEMENT
ELEC ELECTRIC OR ELECTRICAL
ELEV or EL ELEVATION
ERCP ELLIPTICAL REINFORCED
CONC. PIPE
ENV ENVIRONMENTAL or
ENVIRONMENT
EQ EQUATION
EQUIP EQUIPMENT
ED EQUIPMENT DRAIN
EX or EXIST EXISTING
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTRUDED
FAB FABRICATED
FOW FACE OF WALK
FT FEET or FOOT FL FENCE LINE or FLOW LINE
FRP FIBERGLASS REINFORCED
PIPE
FOC FIBER OPTIC CABLE
F FILL
FA FILTER AIR or FOUL AIR
FBW FILTER BACKWASH
FE FILTER EFFLUENT or FINISH
ELEVATION
FO FILTER OVERFLOW
FSD FILTER SUMP DRAIN
FWW FILTER WASH WATER
FIN FINISH
FF FINISH FLOOR
FHA FIRE HYDRANT ASSEMBLY
FTG FITTING or FOOTING
FLG FLANGE
FES FLARED END SECTION
FLX FLEXIBLE
FLR FLOOR
FD FLOOR DRAIN
FL FLOW LINE
FM FORCE MAIN
FA FOUL AIR PIPE
FND FOUND
FIP FOUND IRON PIPE
FIR FOUND IRON ROD
FIRC FOUND IRON ROD & CAP
FN&D FOUND NAIL & DISK
GAL GALLON
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GALV/GLV GALVANIZED
GSP GALVANIZED STEEL PIPE
G GAS LINE
GV GATE VALVE
GA GAUGE
GTEB GENERAL TELEPHONE BURIED
GEO GEODETIC
GRD GRADE
GE GRATE ELEVATION
GI GRATE INLET
GRT'G GRATING
GS GRAVITY SEWER or GROUND SHOT
GS GREASE/SEPTAGE
GP GROUND POINT
GST GROUND STORAGE TANK
HT HAMMER TAP or HEIGHT
HA HAND AUGER
HH HAND HOLE
HR HAND RAIL
HDD HORIZONTAL DIRECTIONAL DRILL
HDPE HIGH DENSITY POLYETHYLENE
HDWL HEAD WALL
HC HIGH CURB or HANDICAP HP HIGH POINT or HORSEPOWER
HSP HIGH SERVICE PUMPS
HWL HIGH WATER LEVEL
HWM HIGH WATER MARK
HWY HIGHWAY
HORZ HORIZONTAL
HB HOSE BIB
HR HOUR
ID IDENTIFICATION
IN INCH
INF INFLUENT
IPS INFLUENT PUMP STATION
ID INSIDE DIAMETER
IR INTERNAL RECYCLE
INT INTERSECTION
IE INVERT ELEVATION
INV INVERT
IP IRON PIPE
IR IRON ROD
IRR IRRIGATION
IV IRRIGATION VALVE
JT JOINT
JB JUNCTION BOX
JD JURISDICTION LINE
LN LANE
LT LEFT
LS LIFT STATION
LP LIGHT POLE
LF LINEAR FEET
LCL2 LIQUID CHLORINE
LL LOT LINE
LP LOW POINT
MAG MAGNETIC
MB MAIL BOX
MH MANHOLE
MARV MANUAL AIR RELEASE VALVE
MAVV MANUAL AIR/VACUUM VALVE
MFR MANUFACTURER
MPS MASTER PUMP STATION
MTL MATERIAL
MAX MAXIMUM
MHW MEAN HIGH WATER
MLW MEAN LOW WATER
(M) MEASURED
MECH MECHANICAL
MJ MECHANICAL JOINT
MG MILLION GALLON
MGD MILLION GALLONS PER DAY
MIN MINIMUM
MISC MISCELLANEOUS
MES MITERED END SECTION
ML MIXED LIQUOR
MOD MODIFIED
MON MONUMENT
MO MOTOR OPERATED
MOV MOTOR OPERATED VALVE
MT MOUNT
NPT NATIONAL PIPE THREAD
NC NORMALLY CLOSED
NO NORMALLY OPEN
N NORTH or NORTHING
N-S NORTH-SOUTH
N/A NOT APPLICABLE or NOT AVAILABLE NIC NOT INCLUDED or NOT IN CONTRACT
NTS NOT TO SCALE
NO or # NUMBER OC ON CENTER or ODOR CONTROL
O/S OFFSET
OP OPEN PIPE
OPNG OPENING
O/E OR EQUAL
OD OUTSIDE DIAMETER
O/A OVERALL
OHE OVERHEAD ELECTRIC
OHL OVERHEAD LIGHT or LINE
OHT OVERHEAD TELEPHONE
OHW OVERHEAD WIRE
PG PAGE
PVMT PAVEMENT
PED PEDESTAL or PEDESTRIAN
PBO PERMANENT BLOW OFF
PRM PERMANENT REFERENCE MONUMENT
PV PINCH VALVE
PE PLAIN END or PLANT EFFLUENT
PB PLAT BOOK
PL PLATE, PLACE or PROPERTY LINE
PLV PLUG VALVE
PNT POINT
PCC POINT OF COMPOUND CURVATURE
PC POINT OF CURVATURE
PI POINT OF INTERSECTION
PRC POINT OF REVERSE CURVE
PT POINT OF TANGENT or POINT
PVI POINT OF VERTICAL INTERSECTION
PLS POLYMER SOLUTION PIPE
PVC POLYVINYL CHLORIDE
PW POTABLE WATER
LB or # POUND
PSI POUNDS PER SQUARE INCH
PP POWER POLE
PCV PRESSURE CONTROL VALVE
PRV PRESSURE REDUCING VALVE
PTE PRETREATED EFFLUENT
PSL PRIMARY SLUDGE LINE
PLS PROFESSIONAL LAND SURVEYOR
PSM PROFESSIONAL SURVEYOR & MAPPER
PROP PROPOSED
PL PROPERTY LINE
PID PROPERTY IDENTIFICATION
PS PUMP STATION
PO PUSH ON
R RADIUS
RP RADIUS POINT
RR RAIL ROAD
ROFCV RATE OF FLOW CONTROL VALVE
RS RAW SEWAGE
RWM RAW WATER MAIN
RCW RECLAIMED WATER
(R) RECORD DATA
RED REDUCER
REF REFERENCE
RLS REGISTERED LAND SURVEYOR
RCP REINFORCED CONCRETE PIPE
REINF REINFORCING
RJW REJECT WATER
REQD REQUIRED
RWGV RESILIENT WEDGE GATE VALVE
RMF RESOURCE MANAGEMENT FACILITY
RRF RESOURCE RECOVERY FACILITY
RAS RETURN ACTIVATED SLUDGE
RU REUSE
RT RIGHT
R/W RIGHT OF WAY
RIM RIM ELEVATION
RD ROOF DRAIN / ROAD
RND ROUND
SP SAMPLE POINT
SCO SANITARY CLEANOUT
SMH SANITARY SEWER MANHOLE
SAN SANITARY SEWER
SCH SCHEDULE
SC SCUM
SE SECONDARY EFFLUENT
S-T-R SECTION, TOWNSHIP & RANGE
SIR SET IRON ROD
SIRC SET IRON ROD & CAP
SHT SHEET
S/W SIDE WALK
SWD SIDE WATER DEPTH
SL SLUDGE
NaOCI SODIUM HYPOCHLORITE SOLUTION
SPECS SPECIFICATIONS
SPLWY SPILLWAY
SH SPRINKLER HEAD
SQ SQUARE
SF SQUARE FEET
SS STAINLESS STEEL
STD STANDARD
SR STATE ROAD
STA STATION
STM STORM
STY STORY
ST STREET
SN SUPERNATANT
SL SURVEY LINE
TS&V TAPPING SLEEVE & VALVE
TEL TELEPHONE
TEMP TEMPORARY
TBO TEMPORARY BLOW OFF
THK THICK
TSL THICKENED SLUDGE LINE
TSR THICKENED SLUDGE RETURN
THD THREADED
TOS TOE OF SLOPE
TOB TOP OF BANK or BERM
TOC TOP OF CURB
TC TOP OF CURVE
TSS TOTAL SUSPENDED SOLIDS
TWE TRUCK WASH EFFLUENT
TYP TYPICAL
UD UNDERDRAIN
UDCO UNDERDRAIN CLEANOUT
UG UNDERGROUND
UGE UNDERGROUND ELECTRIC
UGT UNDERGROUND TELEPHONE
USC & GS UNITED STATES COASTAL &
GEODETIC SURVEY
UB UTILITY BOX
VTH VACUUM TEST HOLE (SOFT DIG)
VAR VARIOUS
VTR VENT THRU ROOF
VERT VERTICAL
VCP VITRIFIED CLAY PIPE
WAS WASTE ACTIVATED SLUDGE
WM WATER MAIN / WATER METER
WS WATER SERVICE
WV WATER VALVE
WWM WELDED WIRE MESH
W/ WITH
W/O WITHOUT
WLP WOOD LIGHT POLE
WPP WOOD POWER POLE
WTP WOOD TELEPHONE POLE
YD YARD
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-C V
-O M
.d w g
A
B
C
D
E
F
G
H
G-4
MAY 2026
LE
G
E N
D A
N D
S Y
M B
O
LS
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
PLAN
A
SHEET ON WHICH
DETAIL IS DRAWN
DETAIL DESIGNATION
SHEET ON WHICH
SECTION IS DRAWN
SECTION DESIGNATION
D1.02
DETAIL TITLE TARGET
SHOWN VARIOUS
SHEETS
DETAIL DESIGNATION
SECTION TITLE TARGET
SHEET ON WHICH
SECTION IS CUT
SECTION DESIGNATION
SUBTITLE OR DESCRIPTION AS RQUED
SECTION & DETAIL TARGET
THIS SYMBOLOGY TO BE
USED FOR SHORT SECTION
CUTS ONLY.SECTION LINE
JB
FH
GENERAL SYMBOLS
DESCRIPTION EXISTING NEW
WATER VALVE
WATER METER
FIRE HYDRANT
AIR RELEASE VALVE
GRAVITY SEWER LINE
FORCE MAIN
SEWER MANHOLE
CLEAN OUT
STORM DRAIN
CATCH BASIN
JUNCTION BOX
GAS LINE
GAS VALVE
PAVED ROAD
CURB & GUTTER
DIRT/GRAVEL ROAD
SIDEWALK
GUARD RAIL
FENCE LINE (LINK)
FENCE LINE (WOOD)
TREE LINE
SILT FENCE
UNDERGROUND FIBER OPTIC
ARV
WV
18SD
DIRT ROAD
FO
8FM
8S SS
FM
SD
POWER POLE
SERVICE POLE
LIGHT POLE
CONCRETE MONUMENT
BUILDING
MATERIALS
EARTH OR GRADE
CONCRETE
ASPHALTIC PAVEMENT
2G GAS
BENCHMARK
GRATING
WM
FH
S
GENERAL NOTES:
1. SIMPLIFIED JOINT SYMBOL IS USED FOR ALL SINGLE LINE PIPING
SHOWN ON THE INTERIOR AND EXTERIOR PIPING DRAWINGS.
2. BOTH SIMPLIFIED AND COMPLEX JOINT REPRESENTATIONS MAY BE
SHOWN ON THE DRAWINGS.
3. UNLESS MODIFIED BY THE GENERAL PROJECT NOTES OR DETAILED
ON THE LAYOUT AND SCHEMATIC DRAWINGS PIPE AND FITTING
JOINT REQUIREMENTS FOR THE VARIOUS PIPE MATERIALS ARE
DEFINED IN THE SPECIFICATIONS.
4. THE CONTRACTOR SHALL CLEAN AND BACTERIOLOGICALLY CLEAR
ALL POTABLE WATER LINES IN ACCORDANCE WITH AWWA C651,
LATEST EDITION.
5. FOR ABBREVIATIONS IN ARCHITECTURAL, STRUCTURAL,
ELECTRICAL, PLUMBING, HVAC, AND INSTRUMENTATION SEE OTHER
DISCIPLINE DRAWINGS IN THIS PLAN SET.
GENERAL SYMBOLS
EXISTING PROPOSED
CRUSHED STONED
PAVING
FLANGED JOINT
ADAPTER
FIRE EXTINGUISHERFE
BFP
REDUCED PRESSURE PRINCIPLE
BACKFLOW PREVENTER
DOUBLE CHECK VALVE BACKFLOW
PREVENTERBFP
TRANSMITTER
T
D: DENSITY
F: FLOW
L: LEVEL
P: PRESSURE
PRESSURE GAUGE
RUBBER EXPANSION JOINT
NEW MAIN THIS PROJECT
SOIL BORING
PIEZOMETER
EXISTING CONTOUR
NEW CONTOUR
EXISTING SPOT ELEVATION
NEW SPOT ELEVATION
EXISTING STRUCTURES
(TO BE MODIFIED)
EXISTING STRUCTURES
(TO BE REMOVED)
FUTURE STRUCTURES
PIPING SYMBOLOGY
FLANGED JOINT SIMPLIFIED
REPRESENTATION.
FLANGED JOINT COMPLEX
REPRESENTATION.
MECHANICAL JOINT COMPLEX
REPRESENTATION.
DIRECTION OF FLOW
FLOW METER, GENERAL SYMBOL
VENTURI FLOW METER
VALVE SYMBOLOGY
UNCLASSIFIED. TYPE AS SHOWN ON THE
DRAWINGS ADJACENT TO SYMBOL
FLOW METER
TELESCOPING VALVE
KNIFE GATE VALVE
GLOBE VALVE
BALL VALVE
3-WAY BALL VALVE
GATE VALVE
4-WAY BALL VALVE
NEEDLE VALVE
PINCH VALVE
DIAPHRAM VALVE
BUTTERFLY VALVE
PLUG VALVE
CHECK VALVE
BALL CHECK VALVE
SOLENOID VALVE
MOTOR OPERATED VALVE
MUD VALVE
FLOOR DRAIN
CALIBRATION CYLINDER
AIR RELEASE VALVE
PIPE TAG
(3) 6" PVC PW
PIPE MATERIAL (OPTIONAL)
ABBREVIATED PROCSS LINE
DESCRIPTION
NOMINAL PIPE SIZE
NUMERICAL INDICATOR
FOR MULTIPLE IDENTICAL
FLOWSTREAMS
VALVE TAG (OPTIONAL)
16" SBT-BV-4
NUMERICAL INDICATOR
UNIQUE NUMBER ASSIGNED
TO EACH GATE USED
(OPTIONAL IF NO SCHEDULE)
ABBREVIATION INDICATING
TYP OF VALVE, i.e. GATE, PLUG, BUTTERFLY, ETC
PROCESS FLOW STREAM
OR STRUCTURE
VALVE SIZE
SB-1
PZ-1
x12.00
12.00
MM
V
K
S
M
12.00
CB
SECTION A
M1.01
DETAIL 1
BUR
CONT
EXP
SUB
ENC
BURIED
CONTAINMENT
EXPOSED
SUBMERGED
CONCRETE ENCASED
EXPOSURE
DI
CPVC
CS
FRP
PVC
SS
DUCTILE IRON
CHLORINATED POLYVINYL CHLORIDE PIPE
CARBON STEEL
FIBERGLASS REINFORCED PLASTIC
POLYVINYL CHLORIDE
STAINLESS STEEL
MATERIAL
FL
MJ
RMJ
WJ
SWJ
THRD
FLANGED
MECHANICAL JOINT
RESTRAINED MECHANICAL
WELDED JOINT
SOLVENT WELD JOINT
THREAD(ED)
JOINT TYPE
AL
ALP
BWD
BYP
CDR
CEN
D
DR
DS
DSL
FE
FOR
FOS
HW
LPO
ML
NPW
OC
OF
PE
PW
PYS
RAS
RCW
RJW
RS
SA
SC
SE
SHC
SPC
SRS
SSM
V
WAS
WM
ALUM
AIR LOW PRESSURE
BACKWASH DRAIN
BYPASS
CONTAINMENT DRAIN
CENTRATE
DRAIN-SANITARY
DRAIN
DIGESTED SLUDGE
DECANT SLUDGE
FILTERED EFFLUENT
FUEL OIL RETURN
FUEL OIL SUPPLY
HOT WATER-POTABLE
LIQUID POLYMER
MIXED LIQUOR
NON POTABLE WATER
ODOR CONTROL
OVERFLOW
PLANT EFFLUENT
POTABLE WATER
POLYMER SOLUTION
RETURNED ACTIVATED SLUDGE
RECLAIMED WATER
REJECT WATER
RAW SEWAGE
SAMPLE
SCUM
SECONDARY EFFLUENT
SODIUM HYPOCHLORITE
SUPPLEMENTAL CARBON
SCREENED RAW SEWAGE
SECONDARY SCUM
VENT
WASTE ACTIVATED SLUDGE
WATER MAIN
PROCESS FLOW IDENTIFICATION
A D2.01
FLOW METERM
SAMPLERS
VAR
CO
BM
CM
LP
SP
PP
SP
PP
LP
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
SCALE: NTS
CO
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-P F-
O M
.d w g
A
B
C
D
E
F
G
H
G-5
MAY 2026
P R
O C
E S
S F
LO
W
D
IA
G R
A M
I
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SPLITTER BOX
PROCESS UNIT NO 1
PROCESS UNIT NO 2
CLARIFIER NO 1
MECHANICAL
SCREEN
MANUAL BAR
SCREEN
CLARIFIER NO 2
GRIT
SURGE TANK
NRCY PUMP
(TYP OF 2)
NRCY PUMP
(TYP OF 2)
RAS/WAS PUMP
(TYP OF 2)
1S T
AN
O
XI
C
(1
,0
G
AL
2N D
AN
O
XI
C
(6 7, GA
L)
RE
AE
RA
TI
O N
(3 3, GA
L)
1S T
AN
O
XI
C
(1
,0
G
AL
2N D
AN
O
XI
C
(6 7, GA
L)
RE
AE
RA
TI
O N
(3 3, GA
L)
AE
RA
TI
O
N (5
,0
G
AL
RAS/WAS PUMP
(TYP OF 2)
6" RAS
8" D
RA
IN
8" D
RA
IN
8" DRAIN
6" RAS
6" W
AS
8" W
AS
LINE "A"
(SEE SHEET G-6
FOR CONTINUATION)
LINE "B"
(SEE SHEET G-6
FOR CONTINUATION)
LINE "C"
(SEE SHEET G-6
FOR CONTINUATION)
BLOWER
(TYP OF 3)
AE
RA
TI
O
N (5
,0
G
AL
LINE "D"
(SEE SHEET G-6
FOR CONTINUATION)
8" WAS
16" CE
16" CE
16" CE
16"
16"
2" RW2" RW
SURGE PUMP
(TYP OF 2)
INFLUENT FLOW METER
COMPOSITE SAMPLER
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \G
-P F-
O M
.d w g
A
B
C
D
E
F
G
H
G-6
MAY 2026
P R
O C
E S
S F
LO
W
D
IA
G R
A M
II
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
CHLORINE CONTACT BASIN
EFFLUENT TRANSFER PUMP
(TYP OF 2)
DIGESTER
IN-PLANT LIFT STATION
RIBS
FILTER NO 1
FILTER NO 2
BACKWASH PUMP
(TYP OF 2)
16"
CCC NO 1
CCC NO 2
EFFLUENT PUMP
(TYP OF 3)
REUSE STORAGE TANK
(1.5 MG)
8" DRAIN
LINE "A"
(SEE SHEET G-5
FOR CONTINUATION)
LINE "B"
(SEE SHEET G-5
FOR CONTINUATION)
LINE "C"
(SEE SHEET G-5
FOR CONTINUATION)
16"
ON-SITE REUSE PUMP
(TYP OF 2)
LINE "D"
(SEE SHEET G-5
FOR CONTINUATION)
2" RW
2" RW
2" RW
2" RW
16"
16"
TO HEADWORKS
BACKWASH PUMP
(TYP OF 2)
TO BIOSOLIDS
DEWATERING BUILDING
8" WAS
EFFLUENT
WET WELL
GENERATOR
BIOSOLIDS
DEWATERING
BUILDING
ODOR CONTROL
HEADWORKS
APPROXIMATE
BOUNDARY
FILTERS
CHLORINE
CONTACT
BLOWERS
PEAK SHAVING TANK
PROPERTY
BOUNDARY
PROPERTY
BOUNDARY
RECLAIMED WATER
HYDRO TANK
STORM WATER
MANAGEMENT AREA
BLOWERS
DIGESTER
TANK
ADMINISTRATIVE
BUILDING
MAINTENANCE
BUILDING
OPERATIONS
BUILDING
PROCESS
UNIT NO. 1
PROCESS
UNIT NO. 2
REUSE STORAGE
TANK
UTILITY EASEMENT
M ay
, 2
C :\U se rs
\d lu go .A
D \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \C
-S P
-O M
.d w g
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
C-1
E X
IS
TI
N G
S
IT
E P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E N
TS
N O
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1"=40'
20' 40' 80'
ISSUED FOR BID
MAY 2026
NOTES:
1. AERIAL PHOTO BACKGROUND DATE MARCH 2021 FROM F.D.O.T AERIAL
PHOTOGRAPHY ARCHIVE.
EFFLUENT
WET WELL
GENERATOR
BIOSOLIDS
DEWATERING
BUILDING
ODOR CONTROL
HEADWORKS
APPROXIMATE
BOUNDARY
30' BUFFER
FILTERS
CHLORINE
CONTACT
BLOWERS
PEAK SHAVING TANK
PROPERTY
BOUNDARY
PROPERTY
BOUNDARY
30' BUFFER
30' BUFFER
PROPOSED
BLOWERS
& PIPING
STORM WATER
MANAGEMENT AREA
DIGESTER
TANK
ADMINISTRATIVE
BUILDING
MAINTENANCE
BUILDING
OPERATIONS
BUILDING
PROCESS
UNIT NO. 1
PROCESS
UNIT NO. 2
REUSE STORAGE
TANK
UTILITY EASEMENT
M ay
, 2
C :\U se rs
\d lu go .A
D \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \C
-S P
-O M
.d w g
A
B
C
D
E
F
G
H
C-2
MAY 2026
S
IT
E P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1"=40'
20' 40' 80'
NOTE:
1. SEE DEMOLITION PLANS FOR EQUIPMENT AND ITEMS TO BE REMOVED.
Point Table Point #
Elevation
96.30
96.30
96.30
96.30
Northing
1716730.39
1716730.39
1716728.39
1716699.64
Easting
569710.43
569730.10
569732.10
569732.10
5 96.30 1716699.64 569710.43
SAN SAN SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN SAN SAN SAN SAN SAN SAN
SAN SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN SAN SAN SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN SAN SAN SAN SAN SAN SAN SAN
SAN
SAN
SAN
SAN
SAN
per the 2019 as built this is the ID point 23 per the 2019 as per the 2019 as built this is the ID point 41 per the 2019 as built this is the ID point 40 per the 2019 as built this is the ID point 42 per the 2019 as built this is the ID point 39
EXISTING BLOWERS
TO BE REMOVED
AIR PIPING TO BE
MODIFIED WITH
NEW BLOWERS
BLOWERS
1 2
.7
5'
21.67'
CORNER CLIPPED TO AVOID PIPING
EXISTING BIO-REACTOR
EXISTING BIO-REACTOR
M ay
, 2
C :\U se rs
\d lu go .A
D \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \C
-G E
-O M
.d w g
A
B
C
D
E
F
G
H
C-3
MAY 2026
G E
O M
E
TR
Y P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1"=10'
5' 10' 20'
SITE PLAN AREA ENLARGEMENT
per the 2019 as built this is the ID point 23 per the 2019 as per the 2019 as built this is the ID point 41 per the 2019 as built this is the ID point 40 per the 2019 as built this is the ID point 42 per the 2019 as built this is the ID point 39
BLOWERS
16" EFFLUENT
8" DRAIN
IN PLANT RETURN
8" DRAIN
12" INFLUENT
8" WAS
IN PLANT RETURN
IN PLANT RETURN
YARD DRAIN
GE 95.75
INV 92.75 (W)
CONCRETE COLLAR
INV 92.10 (E)
63 LF OF 6" PVC
SCH 40 @1.04%
M ay
, 2
C :\U se rs
\d lu go .A
D \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \C
-Y P
-O M
.d w g
A
B
C
D
E
F
G
H
C-4
MAY 2026
Y A
R D
P
IP
IN
G
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1"=10'
5' 10' 20'
DRAIN COLLAR DETAIL
4"
6"
6" per the 2019 as built this is the ID point 23 per the 2019 as built this is the ID point 88 per the 2019 as built this is the ID point 41 per the 2019 as built this is the ID point 40 per the 2019 as built this is the ID point 42 per the 2019 as built this is the ID point 39
95 96
1 2
BLOWERS
SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
AIR PIPING SUPPORTS
AND FOOTERS
YARD DRAIN
RIM 95.75
INV 92.75 (W)
SUMP 92.25
CONCRETE COLLAR
INV 92.10 (E)
63 LF OF 6" PVC @
1.04%
Point Table Point #
Description
CONCRETE SLAB
CONCRETE SLAB
CONCRETE SLAB
CONCRETE SLAB
CONCRETE SLAB
Elevation
96.30
96.30
96.30
96.30
96.30
M ay
, 2
C :\U se rs
\d lu go .A
D \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \C
-G R
D R
-O M
.d w g
A
B
C
D
E
F
G
H
C-5
MAY 2026
G R
A D
IN
G
A N
D D
R A
IN
A
G E
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
LEGEND:
= EXISTING SPOT ELEVATION
= PROPOSED SPOT ELEVATION
= EXISTING MINOR CONTOUR (1FT)
= EXISTING MAJOR CONTOUR (5FT)
= PROPOSED MINOR CONTOUR (1FT)
= PROPOSED MAJOR CONTOUR (5FT)
= EXISTING FLOW ARROW
=PROPOSED FLOW ARROW
= POINT NUMBER
100.00
100.00
SCALE: 1"=10'
5' 10' 20'
NOTES:
1. INSTALL 0.5" EXPANSION JOINT, MATCH EXISTING ELEVATION OF CONCRETE SLAB.
ADAPTER ANGLES
VARIABLE 0° - 360°
ACCORDING TO
PLAN
SUMP DEPTH
PER PLAN
4" MIN
HEIGHT PER PLAN
VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:
4" - 24" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,
ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
INTEGRATED DUCTILE IRON
FRAME & GRATE TO MATCH BASIN O.D.
NYLOPLAST 24" DRAIN BASIN:
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
TOP SOIL
GRATE/COVER
4" MIN ON 8" - 24"
6" MIN ON 30" & 36"
GENERAL CONDITIONS
1. ALL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE MECHANICAL, CIVIL, ELECTRICAL AND SHOP DRAWINGS AND SPECIFICATIONS.
2. THE CONTRACTOR SHALL REVIEW AND VERIFY DIMENSIONS SHOWN IN ALL PLANS AND REVIEW
ALL FIELD CONDITIONS THAT MAY AFFECT THE WORK DEPICTED ON THE DRAWINGS. SHOULD
DISCREPANCIES APPEAR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING TO
OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING WITH THE WORK.
3. FOR ALL ITEMS EMBEDDED IN OR PASSING THROUGH CONCRETE, THE CONTRACTOR SHALL
INITIALLY REFER TO MECHANICAL DRAWINGS FOR TYPE, SIZE, LOCATION, AND SPECIAL
INSTALLATION REQUIREMENTS FOR THESE ITEMS.
4. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT EXISTING
STRUCTURES FROM DAMAGE WHEN WORKING IN AND AROUND EXISTING STRUCTURES WHILE
PERFORMING WORK SUCH AS DEMOLITION, FOUNDATION EXCAVATIONS, AND OTHERS.
5. SIZE AND LOCATION OF EQUIPMENT PADS AND ANCHOR BOLTS SHALL BE PER EQUIPMENT
MANUFACTURER'S REQUIREMENTS.
6. THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INDICATE METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL
MEASURES NECESSARY TO PROTECT EXISTING AND NEW STRUCTURES DURING
CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING,
SHORING, ET CETERA FOR ALL CONSTRUCTION PHASE LOADS.
7. ANY EQUIPMENT THAT MAY INDUCE VIBRATION TO THE STRUCTURE SHALL BE ADEQUATELY
ISOLATED FROM THE STRUCTURE.
8. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
DESIGN CRITERIA
1. DESIGN BUILDING CODE: 2023 FLORIDA BUILDING CODE, 8TH EDITION
2. REINFORCED CONCRETE: ACI 318-19 "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE"
3. STRUCTURAL STEEL: AISC MANUAL OF STEEL CONSTRUCTION, 15TH EDITION
4. ALUMINUM: ADM1-2020, ALUMINUM DESIGN MANUAL
5. DEAD LOADS: ACTUAL WEIGHT
6. LIVE LOADS:
PROCESS RELATED STRUCTURES:
WALKWAYS, STAIRWAYS AND LANDINGS: 100 PSF
ELEVATED SLABS AT PROCESS AREAS: 200 PSF
SLABS ON GRADE 300 PSF
BUILDINGS:
ROOF 20 PSF
STORAGE AREAS (HEAVY), ELECTRICAL ROOMS 300 PSF
STORAGE AREAS (LIGHT) 150 PSF
7. RAIN LOADS:
RAIN INTENSITY 4.5 IN/HR
RAIN LOAD, R 10.4 PSF
8. RISK CATEGORY: III
9. WIND DESIGN CRITERIA:
ULTIMATE DESIGN WIND SPEED, VULT 147 MPH
NOMINAL DESIGN WIND SEED, VASD 114 MPH
EXPOSURE CATEGORY C
ENCLOSURE CLASSIFICATION ENCLOSED STRUCTURE
INTERNAL PRESSURE COEFFICIENT, GCpi + / - 0.18
TORNADO WIND SPEED, VT 50 MPH
EFFECTIVE PLAN AREA, AE 1,230 SF
IS TORNADO WIND DESIGN EXEMPT YES, VT < 60 MPH
10. SNOW LOAD: N/A
11. SEISMIC DESIGN CRITERIA: N/A
FOUNDATIONS
GEOTECHNICAL REPORT:
1. GEOTECHNICAL REPORT "REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL
ENGINEERING EVALUATION" PREPARED BY GEO HYDRO ENGINEERS, GEO-HYDRO PROJECT
NUMBER 160205.20, DATED MAY 3, 2015. ANY INTERPRETATION OF THE CONTENTS OF THE
GEOTECHNICAL REPORT IS THE RESPONSIBILITY OF THE CONTRACTOR.
FOUNDATION DESIGN:
1. ALLOWABLE BEARING PRESSURE FOR MAT SLAB: 2,000 PSF
CONCRETE (CAST-IN-PLACE)
1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318
REQUIREMENTS.
2. ALL CONCRETE SHALL BE AIR-ENTRAINED WITH A MINIMUM OF 4,000 PSI COMPRESSIVE
STRENGTH AT 28 DAYS UNLESS OTHERWISE NOTED.
3. WATER REDUCING AGENT SHALL BE IN ACCORDANCE WITH ASTM C494.
4. ALL CONCRETE SURFACES EXPOSED TO AIR, UNLESS OTHERWISE NOTED IN THE
SPECIFICATIONS, SHALL BE TREATED WITH AN APPROPRIATE CURING METHOD AS SOON AS
FINISHING IS COMPLETED OR FORMS ARE REMOVED.
5. ALL EXPOSED CORNERS SHALL HAVE A MINIMUM CHAMFER OF 3/4" UNLESS OTHERWISE NOTED.
6. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR THE LOCATIONS OF
CONSTRUCTION JOINTS THAT ARE NOT SHOWN ON THE DRAWINGS.
REINFORCING STEEL
1. REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60 REQUIREMENTS. WELDED WIRE
FABRIC SHALL CONFORM TO ASTM A1064 REQUIREMENTS. ALL ACCESSORIES SHALL BE IN
CONFORMANCE WITH ACI 315 REQUIREMENTS.
2. REINFORCING STEEL SHALL HAVE THE FOLLOWING CLEAR COVER UNLESS OTHERWISE NOTED:
a. CONCRETE CAST AGAINST EARTH 3"
b. FORMED SURFACE IN CONTACT WITH SOIL, SEWAGE, 2"
WATER OR EXPOSED TO WEATHER
3. LAP SPLICES SHALL BE AS SHOWN ON THE DRAWINGS. FOR LAP SPLICES NOT SHOWN ON THE
DRAWINGS, THE CONTRACTOR SHALL OBTAIN ENGINEERS APPROVAL.
4. THE CONTRACTOR SHALL PREPARE PLACING DRAWINGS AND SCHEDULES IN CONFORMANCE
WITH ACI 315 REQUIREMENTS.
5. UNLESS OTHERWISE NOTED, THE MINIMUM REINFORCING FOR WALLS AND SLABS SHALL BE AS
FOLLOWS.
STRUCTURAL STEEL
1. DESIGN, FABRICATION, ERECTION MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE
WITH THE LATEST AISC SPECIFICATIONS AND THE DESIGN DRAWINGS.
2. STEEL MATERIAL:
a. W-SHAPED SECTIONS : ASTM A992, GRADE 50
b. HOLLOW STRUCTURAL SECTIONS: ASTM A500, GRADE B
c. ALL OTHER STRUCTURAL STEEL: ASTM A36
d. ALL PIPE: ASTM A53, GRADE B
3. WELDED CONNECTIONS SHALL BE IN ACCORDANCE WITH THE LATEST AWS STRUCTURAL
WELDING CODE REQUIREMENTS. ELECTRODES SHALL BE E-70XX. SUBMIT CERTIFICATIONS THAT
WELDERS ARE QUALIFIED IN ACCORDANCE WITH AWS D1.1 ON THE SHOP AND FIELD WELDED
PROCEDURES TO BE USED. CERTIFICATION SHALL BE WITHIN PREVIOUS 12 MONTHS.
4. BOLTED CONNECTIONS:
a. MAIN CONNECTIONS: 3/4" DIA, ASTM A325 BOLTS. HOLES: 13/16" DIA CONNECTION SHALL BE
"BEARING" TYPE WITH THREADS EXCLUDED FROM THE SHEAR PLANE.
b. SECONDARY CONNECTION: 3/4" DIA, ASTM A307 GRADE A BOLTS.
c. ALL CONNECTION SHALL HAVE A MINIMUM OF TWO BOLTS. GUSSET PLATES SHALL BE A
MINIMUM OF 3/8" THICK.
d. ALL COLUMNS AND POSTS SHALL HAVE MILLED ENDS FOR FULL BEARING AT BASE PLATES.
e. ALL FIELD WELDS MUST BE TOUCHED-UP WITH A HEAVY COAT OF ZINC RICH PAINT IN
ACCORDANCE WITH ASTM A780.
5. ALL STEEL FABRICATIONS SHALL BE MATCH MARKED FOR FIELD ASSEMBLY.
6. WHERE GALVANIZED STEEL IS INDICATION ON THE DRAWINGS ALL STEEL IS TO BE HOT-DIPPED
GALVANIZED IN ACCORDANCE WITH ASTM A123.
6. WHERE GALVANIZED STEEL HARDWARE IS INDICATION ON THE DRAWINGS ALL HARDWARE IS TO
BE GALVANIZED IN ACCORDANCE WITH ASTM A153.
ALUMINUM
1. ALUMINUM DESIGN, DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE LATEST
EDITION OF THE ALUMINUM DESIGN MANUAL.
2. ALUMINUM IN CONTACT WITH OR EMBEDDED IN CONCRETE OR MASONRY SURFACES SHALL BE
COATED WITH A HEAVY COATING OF ALKALI RESISTANT BITUMINOUS PAINT.
3. ALL BOLTS USED IN CONNECTIONS WITH ALUMINUM MEMBERS SHALL BE STAINLESS STEEL
TYPE 316, UNLESS NOTED OTHERWISE.
4. ALL WELDING OF ALUMINUM STRUCTURES SHALL CONFORM TO "STRUCTURAL WELDING CODE -
ALUMINUM", AWS D1.2, LATEST EDITION.
STAINLESS STEEL
1. STAINLESS STEEL MATERIALS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
a. EXTERIOR AND SUBMERGED USE: TYPE 316
TYPE 316L (WHERE WELDED)
a. INTERIOR AND ARCHITECTURAL USE : TYPE 304
TYPE 304L (WHERE WELDED)
2. ALL WELDING OF STRUCTURAL STAINLESS STEEL SHALL CONFORM TO "STRUCTURAL WELDING CODE - STAINLESS STEEL", AWS D1.6, LATEST EDITION. ELECTRODES SHALL BE E-318 316L
STAINLESS STEEL.
3. STAINLESS STEEL PLATES, SHEETS AND WASHERS SHALL BE IN ACCORDANCE TO ASTM A240.
4. STAINLESS STEEL W SHAPES, CHANNELS AND ANGLES SHALL BE IN ACCORDANCE TO ASTM
A276.
5. ALL BUILT-UP ASSEMBLIES SHALL BE FUSED BY LASER IN ACCORDANCE WITH ASTM A1069 FOR
NON TUBULAR SHAPES OR WELDED IN ACCORDANCE WITH ASTM A554 FOR TUBULAR SHAPES.
6. STAINLESS STEEL BOLTS AND THREADED RODS SHALL BE TYPE 316 IN ACCORDANCE TO ASTM
F593 UNLESS NOTED OTHERWISE.
7. STAINLESS STEEL NUTS SHALL BE TYPE 316 IN ACCORDANCE TO ASTM F594 UNLESS NOTED
OTHERWISE.
FLOTATION CONSIDERATION
1. STRUCTURES WERE DESIGNED TO BE NON-BUOYANT AFTER THEY ARE PLACED INTO
OPERATION. THEREFORE THE STRUCTURES MAY BE BUOYANT DURING CONSTRUCTION.
GENERAL CONTRACTOR SHALL PROTECT ALL STRUCTURES FROM FLOTATION DURING
CONSTRUCTION REGARDLESS OF GROUND WATER LEVELS UNTIL STRUCTURES ARE PLACED
INTO OPERATION.
PRE-ENGINEERED METAL BUILDING
1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED TO DESIGN,
FABRICATE, DELIVER TO JOB SITE AND ERECT THE PRE-ENGINEERED METAL BUILDING AS
SHOWN ON THE CONTRACT DOCUMENTS.
2. SUBMIT TO THE ENGINEER AS PROVIDED COMPLETE PLANS SHOWING SUPERSTRUCTURE
COLUMN LINES SET TO COORDINATE WITH CONCRETE DIMENSIONS SHOWN. INDICATE ANCHOR
BOLT SIZE AND LOCATIONS AND FOUNDATION REACTIONS IN KIPS AT ALL COLUMNS.
FOUNDATION SIZE AND REINFORCEMENT FOR PRE-ENGINEERED METAL BUILDING ARE
PRELIMINARY AND ARE SUBJECT TO CHANGE UNTIL FINAL REACTIONS ARE PROVIDED BY
BUILDING MANUFACTURER AND APPROVED BY THE ENGINEER OF RECORD.
3. SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATION PREPARED BY A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA CERTIFYING THAT THE
STRUCTURAL FRAMING AND COVERING PANELS PROPOSED MEET THE DESIGN CRITERIA.
4. PRIOR TO FOUNDATION CONSTRUCTION, PRE-ENGINEERED METAL BUILDING SUBMITTAL MUST
BE APPROVED. CONSTRUCTION DETAILS MAY BE VARIED TO SUIT MANUFACTURER'S STANDARD
DESIGN.
5. ALL BUILDING COLUMNS SHALL BE DESIGNED AS "PIN" CONNECTED. COLUMN ENDS SHALL NOT
TRANSFER MOMENTS TO FOUNDATION. ANCHOR BOLTS SHALL BE DESIGNED BY THE BUILDING
MANUFACTURER AND FURNISHED BY THE CONTRACTOR.
6. SEE SPECIFICATION SECTION 13121 "PRE-ENGINEERED METAL BUILDING" FOR REQUIREMENT IN
ADDITION TO THESE NOTES.
GENERAL STRUCTURAL NOTES STRUCTURAL ABBREVIATIONS
& AND
@ AT
# NUMBER
ADDTL ADDITIONAL
AFF ABOVE FINISHED
FLOOR
ALUM ALUMINUM
AEWS AUTOMATIC END
WELDED STUD(S)
ALT ALTERNATE
APROX APPROXIMATE(LY)
BLD BUILDING
BM BEAM
BOT BOTTOM
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY
UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CTR CENTER
DIA DIAMETER
DIM DIMENSION
DEG DEGREE(S)
DO DITTO
DWG DRAWING
DWL DOWEL(S)
(E) EXISTING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMBED EMBEDMENT
EQ EQUAL
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
FE FIRE EXTINGUISHER
FF FAR FACE, FINISHED
FLOOR
FG FINISHED GRADE
FRP FIBER REINFORCED
PLASTIC
FT FOOT
FTG FOOTING
FV FIELD VERIFY
GA GAGE
GALV GALVANIZED
HK HOOK
HORIZ HORIZONTAL
HSS HOLLOW STRUCTURAL
SECTION
HP HIGH POINT
ID INSIDE DIAMETER
JT JOINT
LB(S) POUND(S)
LONG LONGITUDINAL
LP LOW POINT
MANUF MANUFACTURER
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
PCS PIECES
PEMB PRE-ENGINEERED
METAL BUILDING
PERP PERPENDICULAR
PL PLATE
PLF POUND PER LINEAR
FOOT
PT PRESSURE TREATED
PROJ PROJECTION
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PVC POLYVINYL CHLORIDE
R RADIUS
REINF REINFORCING
REQD REQUIRED
RO ROUGH OPENING
SCHED SCHEDULE(D)
SIM SIMILAR
SJ SAWCUT JOINT
SMS SHEET METAL SCREW
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
T/ TOP OF
TB TIE BEAM
T&B TOP AND BOTTOM
THK THICK
THRU THROUGH
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED
OTHERWISE
VERT VERTICAL
WT WEIGHT
WWF WELDED WIRE FABRIC
MINIMUM REINFORCING
THICKNESS 6" 8" 10" 12" - 16" 18" - 22" 24"
REINF. EACH WAY #4 @ 12" #5 @12" #5 @ 12" #5 @ 12" #6 @ 12" #7 @ 12"
LOCATION CTR CTR EF EF EF EF
DWG. NODWG. NO. OF
SECTION VIEW
SECTION NO. DETAIL NO.
ELEVATION TAGT/SLAB
EL.0.00
COLUMN OR WALL LINE TAG
BUILDING SECTION
INDICATOR DETAIL
INDICATOR
SYMBOLS APPLY TO "S" SHEETS ONLY
EARTH FILL
UNDISTURBED EARTH
GROUT OR SAND (AS NOTED)
COMPACTED GRANULAR FILL
CONCRETE
DEMOLITION
EXISTING
CONCRETE
STEEL
PRECAST CONCRETEGRATING
STRUCTURAL LEGEND APPLIES TO "S" SHEETS ONLY
SYMBOLSLEGEND
A
S00
S00
INDICATES DETAIL SECTION
CUT (WHERE SHOWN)
M ay
1, P
:\A rd ur ra
\2 4-
O ak
R un
W W
TF
E xp an si on
\D ra w in gs \O a nd
M S tr uc tu ra l\S -1
.d w g
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1320 WILIFRED DRIVE
ORLANDO, FL 32803
P: 407.219.4454 COA Lic. No: 31920
WEKIVA PROJECT #24-170
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
ISSUED FOR BID
MAY 2026
JOB NO: 2024-1306
A
R
IO
N C
O U
N
TY
U
TI
LI
TE
S S
O U
TH
W
E S
T R
E G
IO
N
A L
W R
F O
M
IM
P
R O
V E
M E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-6510 www.Ardurra.com
S-1
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S, AB
BR
EV
IA
TI
O N
S, L
EG
EN
D A
N D
SY
M
BO
LS
PROPOSED PIPING PER
"M" DRAWINGS; NOT
SHOWN IN ENTIRETY FOR
CLARITY
PROPOSED PIPE SUPPORT
PER DETAIL; PROVIDE
SUPPORTS ALONG LENGTH
OF PIPE AT 15'-0" OC
A
S-3
BLOWER SLAB
3/8"=1'-0"
PLAN
'-9
21'-8"
12" SLAB REINF W/
#5AT10", EW T&B
EQUIP PAD
PER DETAIL,
TYP
C
S-3
14'-0" 14'-0"
1' -2
9'
-4
9' -6
2'-6"
THICKEN SLAB TO
18" OVER WIDTH
SHOWN
M ay
1, P
:\A rd ur ra
\2 4-
O ak
R un
W W
TF
E xp an si on
\D ra w in gs \O a nd
M S tr uc tu ra l\S -2
.d w g
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1320 WILIFRED DRIVE
ORLANDO, FL 32803
P: 407.219.4454 COA Lic. No: 31920
WEKIVA PROJECT #24-170
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
ISSUED FOR BID
R
IO
N C
O U
N
TY
U
TI
LI
TE
S S
O U
TH
W
E S
T R
E G
IO
N
A L
W R
F O
M
IM
P
R O
V E
M E
D
A
TE
R E
V
IS
IO
N
Phone: (904) 593-6510 www.Ardurra.com
S-2
M
IS
C
EL
LA
N
EO
U
S
SL
AB
S
STANDARD HOOK DEVELOPMENT
LENGTH
BAR SIZE
#3
#4
#5
#6
#7
#8
#9
#10
#11
90° STD
HOOK "A"
6"
8"
10"
1'-0"
1'-2"
1'-4"
1'-7"
1'-10"
2'-0"
6"
7"
9"
10"
1'-0"
1'-2"
1'-3"
1'-5"
1'-7"
90° HOOK
BA
R
D
IA
A
180° HOOK
BA
R
D
IA
4 BAR DIA.
OR
2" MIN.
4 BAR DIA. (#3 TO #8 BAR)
5 BAR DIA. (#9 TO #11 BAR)
ld ldh ldh
J
MIN. LAP LENGTH
*SPACING NOT TO BE GREATER THAN 1/5
LAP LENGTH OR 6IN. WHICH EVER IS LESS
180° STD
HOOK "J"
3"
4"
5"
6"
7"
8"
4"
1'-11 4"
1'-23 4"
DEVELOPMENT
LENGTH,
ldh
*FOR STD HOOK BAR GEOMETRY
NOT SHOWN REFER TO MINIMUM ACI
REQUIREMENTS
BAR SIZE
#3
OTHER BARS
#4
#5
#6
#7
#8
#9
#10
#11
TOP BARS
DEVELOPMENT LENGTH, ld
1'-7"
2'-1"
2'-7"
3'-1"
4'-6"
5'-2"
5'-10"
6'-6"
7'-3"
1'-3"
1'-7"
2'-0"
2'-4"
3'-6"
3'-11"
4'-6"
5'-0"
5'-7"
CONCRETE STRENGTH f`c= 4,000 PSI OR GREATER
NOTES:
1. GRADE 60 UNCOATED REINFORCEMENT
2. SPLICE LENGTHS GIVEN ABOVE ARE TO BE USED
UNLESS NOTED OTHERWISE ON DESIGN DRAWINGS.
3. "TOP BARS" INCLUDE ALL TOP BARS IN SLABS AND ALL WALL HORIZONTALS.
TOP BARS
LAP LENGTH (CLASS B SPLICE)
2'-0"
2'-8"
3'-4"
4'-0"
5'-10"
6'-8"
7'-6"
8'-6"
9'-6"
1'-7"
2'-0"
2'-7"
3'-1"
4'-6"
5'-2"
5'-10"
6'-6"
7'-3"
OTHER BARS
REBAR MINIMUM TENSION DEVELOPMENT & LAP LENGTHS
MAXIMUM BAR SPACING AT NON-CONTACT LAPS:
BAR SIZE
#3
#4
#5
#6
#7
#8
#9
#10
#11
DETAIL B
-NTS
STANDARD REINFORCEMENT DETAILS
DETAIL D
-NTS
CHAMFER
3/4" CHAMFER ALL
EXPOSED CORNERS
DETAIL C
-NTS
EQUIPMENT PAD
4" M
IN
O
R P
ER
M
AN
U
F R
EQ
U
IR
EM
EN
TS
NOTE:
1. FOR EXISTING CONCRETE SLAB DRILL AND EPOXY
#5AT12" AROUND PERIMETER W/ 6" MIN EMBEDMENT.
BASIC SLAB
REINF PER PLAN
#4 AT 6"
ROUGHENED JOINT
SEE NOTE
COMPACTED
SUBGRADE
COMPACTED SUBBASE
PER SPECIFICATIONS
3/4" CHAMFER
6x6x3/8 GALV POST
ANCHORS PER PLAN
CL
L4x7x1/4" LLH BENT PLATE
GALV OVER POST
1/2" DIA SS 316 "U"
BOLT TO TOP FLANGE
OF ANGLE
3/16" 3/16"
PIPING PER "M" SHEETS;
PROVIDE TEFLON BEARING PAD
BETWEEN PIPE AND ANGLE
AND SIZE "U" BOLT TO 1/4"
LARGER THAN OD OF PIPE; DO
NOT OVER-TIGHTEN "U" BOLT
C O
O R
D W
M
" S H
EE
TS
'-0
" M
AX
1/2" NON-SHRINK
GROUT BELOW
BASE PLATE
2"
4'-6"
SQR
1'-0"
MAX
CL
3/8" STIFFENER PLATE
ON EACH SIDE OF
THE POST
1'-4"
1' -4
3/4"
CHAMFER,
TYP
(8)-#5 VERT W/
#3AT6" TIES w/ (3)
EQUALLY SPACED IN
THE TOP 5"
PLAN AT PEDESTAL
(4)-1" DIA SS TYPE 316
CAST-IN ANCHORS W/
12" MIN EMBED W/
NUT AT BOT OF
ANCHORS
12X12X1"
6" 6"
1' -0
8"
PLAN AT
BASE PLATE
3/16"
6"
1/4" CAP PLATE
1' -0
1'
-0
1' -0
DETAIL A
-NTS
PIPE SUPPORT
#5 "U" BAR PER
SECTION; PROVIDE
8" LONG HORIZ LEG
#5 "U" BAR
LAPPING W/
VERT 1'-10"
PROVIDE FOOTING
AND PEDESTAL
WHERE SUPPORT IS
NOT LOCATED ON A
PROPOSED SLAB
DIMENSION MAY
BE REDUCED TO
0" AS NEEDED
#6AT12" T&B, EW
M ay
1, P
:\A rd ur ra
\2 4-
O ak
R un
W W
TF
E xp an si on
\D ra w in gs \O a nd
M S tr uc tu ra l\S -2
.d w g
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1320 WILIFRED DRIVE
ORLANDO, FL 32803
P: 407.219.4454 COA Lic. No: 31920
WEKIVA PROJECT #24-170
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
ISSUED FOR BID
R
IO
N C
O U
N
TY
U
TI
LI
TE
S S
O U
TH
W
E S
T R
E G
IO
N
A L
W R
F O
M
IM
P
R O
V E
M E
D
A
TE
R E
V
IS
IO
N
Phone: (904) 593-6510 www.Ardurra.com
S-3
PI
PE
S U
PP
O
R T
D
ET
AI
LS
ST
AN
D
AR
D
D
ET
AI
LS
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-B L-
O M
.d w g
A
B
C
D
E
F
G
H
M-1
MAY 2026
E X
IS
TI
N G
B
LO
W E
R S
D E
M O
LI
TI
O N
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 3/8"=1'-0"
2' 4' 6'
PLAN
DEMOLISH BLOWER AND
EQUIPMENT PAD
(TYP OF 3)
DEMOLISH AIR PIPING (TYP)
DEMOLISH AIR PIPING (TYP)
REMOVE AND RELOCATE
EXISTING LIGHT POLE
(SEE ELECTRICAL FOR DETAILS)
PROCESS UNIT NO 2
PROCESS UNIT NO 1
DEMOLISH CONCRETE SLAB
AND SIDEWALK
8" DI IN-PLANT RETURN
8" DI IR
12" DI IR
8" DI
12" DI IR
12" INFLUENT
12" INFLUENT
12" DI IR
12" INFLUENT
1/2" NaOCl FEED
2" NPW
SCALE: 3/8" =1'-0"
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-B L-
O M
.d w g
A
B
C
D
E
F
G
H
M-2
MAY 2026
B
LO
W E
R S
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1/2"=1'-0"
1' 2' 4'
PLAN
'-9
10" 90° BEND
10" BFV
10" EXPANSION JOINT
(TYP OF 3)
10" 90° BEND
(TYP OF 2)
10" BFV W/
CHAIN WHEEL OPERATOR
(TYP OF 6)
21'-8"
4'-6" 10'-10" (TYP) 6'-4"
3' -0
TY
P) 6'
-0
TY
P)
3' -5
CUT INTO EXISTING
10" AIR PIPE AND INSTALL
10 TEE
10" BFV
(TYP OF 2)
CONNECT TO EXISTING
10" EXPANSION JOINT
(TYP OF 2)
BLOWER NO 1
BLOWER NO 2
BLOWER NO 3
A M-3
A M-3
PIPE SUPPORT (TYP)
(SEE STRUCTURAL SHEETS)
10" SS AIR
10" SS AIR
PROCESS UNIT NO 2
PROCESS UNIT NO 1
PIPE SUPPORT
(TYP OF 3)
MD-1
SLOPE PIPE 1%
(TO CONDENSATE BLOWOFF)
SLOPE PIPE 1%
(TO CONDENSATE BLOWOFF)
1/2" NaOCl FEED
2" NPW
3/4" CONDENSATE BLOWOFF
(TYP OF 2)
10" TEE
(TYP OF 3)
PRESSURE TRANSMITTER
(TYP OF 2)
I2
I-6
SCALE: 3/8" =1'-0"
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-B L-
O M
.d w g
A
B
C
D
E
F
G
H
B
LO
W E
R S
E C
TI
O
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B Y
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 1/2"=1'-0"
1' 2' 4'
SECTION A
M-2
21'-8"
CL EL 98.30
CL EL 113.00±
(MATCH EXST CL ELEVATION)
GRADE EL 96.00
CONCRETE
EQUIPMENT PAD
BLOWER NO 1
4'-6" (TYP) 10'-10"
10" EXPANSION JOINT
10" BFV
10" 90° BEND
10" TEE
10" 90° BEND
10" SS AIR
TANK WALL
TOP OF WALL
EL 112.50±
3/4" BV SS
3/4" 90° BEND
3/4" THREADED BOSS CONNECTION
(2) 3/4" 45° BEND
PIPE SUPPORT
PIPE SUPPORT
M-3
3/4" PVC CONDENSATE BLOWOFF
MD-1
10" SS
AIR
GRADE EL 96.00
PIPE SUPPORT (TYP)
(SEE STRUCTURAL SHEETS)
PIPE SUPPORT
(SEE STRUCTURAL SHEETS)
MD-1
CL EL 113.00±
(MATCH EXST CL ELEVATION)
C
S-3EL 96.30
SCALE: 1/2" = 1'-0"
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-C C
-O M
.d w g
A
B
C
D
E
F
G
H
M-4
MAY 2026
E X
IS
TI
N G
C H
LO
R
IN
E
C O
N
TA
C T
B A
S
IN
D E
M O
LI
TI
O N
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
SCALE: 3/16"=1'-0"
4' 8' 16'
PLAN
3'-0"x1'-0" OPENING
(TYP OF 2)
DEMOLISH 16"
CONTROL VALVE
AND CONTROLS
TURBIDITY
SAMPLE PUMP
DRAIN SUMP
1/2" SH
3'-0" SQ ACCESS HATCH
(TYP OF 3)
EFFLUENT
SAMPLER
NPW BOOSTER STATION
CHLORINE
ANALYZER
TURBIDMETER
EFFLUENT WETWELL
CHLORINE CONTACT BASIN
EFFLUENT
PUMP NO 3
EFFLUENT
PUMP NO 2
EFFLUENT
PUMP NO 1
EFFLUENT
TRANSFER
PUMP NO 1
EFFLUENT
TRANSFER
PUMP NO 2
DEMOLISH
15,000 GALLON HYDROPNEUMATIC TANK AND
CONCRETE FOOTINGS
DEMOLISH
10" RCW
16" EFF
16" EFF
24" RCW
16" RCW
16" RCW
4" DRN
4" DRN3" NPW
12" MAG
METER
DEMOLISH
AIR COMPRESSOR
AND CONTROLS
SCALE: 3/16" =1'-0"
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-C C
-O M
.d w g
A
B
C
D
E
F
G
H
M-5
MAY 2026
E X
IS
TI
N G
C H
LO
R
IN
E
C O
N
TA
C T
B A
S
IN
M O
D
IF
IC
A
TI
O
N S
P
LA
N
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
PLAN
3'-0"x1'-0" OPENING
(TYP OF 2)
TURBIDITY
SAMPLE PUMP
DRAIN SUMP
1/2" SH
3'-0" SQ ACCESS HATCH
(TYP OF 3)
EFFLUENT
SAMPLER
NPW BOOSTER STATION
CHLORINE
ANALYZER
TURBIDMETER
EFFLUENT WETWELL
CHLORINE CONTACT BASIN
EFFLUENT
PUMP NO 3
EFFLUENT
PUMP NO 2
EFFLUENT
PUMP NO 1
EFFLUENT
TRANSFER
PUMP NO 1
EFFLUENT
TRANSFER
PUMP NO 2
16" EFF
16" EFF
24" RCW
16" RCW
16" RCW
4" DRN
4" DRN
3" NPW
12" MAG
METER
ULTRASONIC TRANSDUCER W/
MANUFACTURER PROVIDED
MOUNTING BRACKET
LEVEL
TRANSMITTER
16" BFV (MOTOR OPERATED)
16" SPOOL PIECE (FLxPE)
M
16" RCW
SCALE: 3/16"=1'-0"
4' 8' 16'
SCALE: 3/16" =1'-0"
, 2
C :\U se rs
\k st ep he ns \D
C \A
C C
D oc s\ A rd ur ra , I nc \2
4-
\P ro je ct
F ile s\
-P ro d\
-D w gs \D
-D E
T- O
M .d w g
A
B
C
D
E
F
G
H
MD-1
MAY 2026
M
IS
C E
LL
A
N E
O U
S M
E C
H A
N
IC
A L
D E
TA
IL
S
M A
R
IO
N C
O U
N
TY
U
TI
LI
TI
E S
S O
U
TH
W E
S T
R E
G
IO
N A
L W
R F
O
M
IM
P R
O V
E M
E
D
A
TE
R E
V
IS
IO
N
B
Phone: (904) 593-5610 www.Ardurra.com
2024-1306
Utilities 11800 S. U.S. Highway 441
Belleview, FL 34420
Phone: 352-307-6000 Fax: 352-307-6001
After hours: 352-307-6000
PROCESS PIPE
SEE NOTES 1, 2 & 3
SEE DETAIL "2"
PRESSURE SEAL WITH 1/4" NPT
CONNECTIONS (SEE SPECIFICATIONS)
SS TEST TAP (1/4" PIPE). LOCATE ON
LOWER DIAPHRAGM FLUSHING CONNECTION
WITH TEE.
1/4" TO MATCH SEAL MATERIAL
1/4" BV MATERIAL TO MATCH PIPE
MATERIAL
SEE DETAIL "3"
RESSURE GAUGE
NOTES:
1. FOR STEEL, GALVANIZED STEEL AND PVC 2-1/2" AND SMALLER,
USE A BUSING IN A TEE.
2. FOR DUCTILE IRON AND FIBERGLASS REINFORCED PLASTIC PIPE,
ALL SIZES, USE PIPE SADDLE WITH BUSHING.
3. FOR STEEL AND STAINLESS STEEL PIPES 3" AND LARGER, AND
PRESSURE VESSELS, USE THRED-O-LET AS SHOWN.
4. PROVIDE SNUBBER FOR POSITIVE DISPLACEMENT PUMP
INSTALLATIONS OR WHERE SHOWN ELSEWHERE.
13 1/4"8 1/2"8"4 1/4"2"3" 1 1/2"
4" 4"
4"
2 1/2"
2 1/2" 2 1/2"
3 1/2" 3 1/2"
2 1/2"
3" 3"
4"
1 1/2"
22 1/2" 24 1/2"
21 5/16"
9 15/16" 10 15/16"
17 15/16"24"
32" 36"
30" 6"
6" 6"
6"
6" 8"
10"
18" 20"
16" 14" 12"
4" 3" 3" 3"
6" 6" 4" 4" 3"
2"
13 1/2"
13 1/2" 13 1/2"
13 1/2"
13 1/2" 13 1/2"
5 1/2"
8 1/2" 6 7/8"
12 3/8" 13 7/8" 15 3/8"
4 1/2"
11" 11"
9" 9" 9" 9"
8"
32 3/4" 34 3/4"
31 1/2"
25 1/2"
22 1/4" 20 3/4"
28 1/4"23 3/4"
28 1/4" 30 1/4"
27"
10 1/2"
13 1/2"
16 1/4" 17 3/4" 19 1/2"
11 3/4"
9 3/4"
21"
15"
15 1/4"
18 1/4" 16 1/2"
24"
19 3/4"
14 1/2"
DIMENSION TABLE
"D"PIPE SIZE "A" "B" "C" "E" MIN. "E" MAX.
"C"
AS
R
EQ
'D
"A"
"B
"E
"D"
SS PIPE SADDLE
SUPPORT
1 1/2" NON-SHRINK GROUT
STD. PIPE FLANGE ATTACH TO
CONC W/ (4) SS STUD TYPE
WEDGE ANCHORS.
SS PIPE
3" THRU 36" PIPE
NOTES:
1. PROVIDE HALF ROUND RIGID INSULATION & INSULATION PROTECTION SHIELD.
2. PROVIDE NEOPRENE WAFFLE ISOLATION PAD UNDER SUPPORT FOOT WHEN PIPING IS ISOLATED OR
SUPPORT IS ADJACENT TO MECHANICAL EQUIPMENT.
3. FOR BASE, HEIGHT, AND FLANGE DIMENSIONS, SEE TABLE.
1/2" CONCRETE ANCHOR, 6" OC
PIPE STRAP SS
NO. & SIZE OF PIPE(S) VARIES.
SEE PLANS
ADJUSTABLE FRAMING CHANNEL SS
NOTES:
1. ALL MATERIALS TO BE 316 SS.
GAUGE/DIAPHRAGM ASSEMBLY GAUGE MOUNTING
3" THRU 36" PIPE SUPPORT
(SADDLE TYPE)
CHEMICAL PIPING SUPPORT
DIMENSIONS
FLANGE CL 125 CRADLE MATERIAL THREAD STUD BASE PLATE EXTENSION PIPE REQ'D MINIMUM DIST. TO FLOOR
3" 1/2" x 2" 1" x 6" 4"x6"x1/4" 2" SCH 40 7"
4" 1/2" x 2" 1" x 6" 8"x8"x1/4" 2" SCH 40 7"
6" 1/2" x 2" 1" x 6" 8"x8"x1/4" 2" SCH 40 7"
8" 1/2" x 2 1/2" 1" x 6" 8"x8"x1/4" 2" SCH 40 7"
10" 1/2" x 2 1/2" 1" x 6" 8"x8"x1/4" 2" SCH 40 7"
12" 1/2" x 2 1/2" 1" x 6" 8"x8"x1/4" 2" SCH 40 7"
14" 5/8" x 3" 1 1/2" x 6" 8"x8"x1/2" 3" SCH 40 9 1/2"
16" 5/8" x 3" 1 1/2" x 6" 8"x8"x1/2" 3" SCH 40 9 1/2"
18" 3/4" x 3 1/2" 2" x 6" 8"x8"x1/2" 4" SCH 40 10"
20" 3/4" x 3 1/2" 2" x 6" 8"x8"x1/2" 4" SCH 40 10"
24" 3/4 x 4" 2" x 6" 8"x8"x1/2" 4" SCH 40 10"
NOTES:
1. FLANGE CRADLE ASTM A36.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .