This document comprises the 100% construction submittal plans for the West Lubbock Water System Expansion project, prepared by Freese and Nichols, Inc. for the City of Lubbock, Texas. The project involves the design and construction of water pipeline infrastructure serving the city's west service area, including transmission and distribution lines with associated appurtenances, yard piping, and cathodic protection systems.
The project encompasses approximately 3,500 linear feet of 36-inch diameter transmission pipeline along 26th Street and Yuma Avenue, approximately 6,000 linear feet of 24-inch diameter distribution pipeline along Alcove Avenue, approximately 745 linear feet of 30-inch diameter pipeline along 29th Street, and supporting yard piping at the proposed pump station site. The scope includes installation of butterfly valves, air release valves, blowoff valves, access manholes, cathodic protection systems with test stations and rectifiers, and associated pavement repair and restoration. Construction is issued for use with an execution date of April 8, 2025. The project requires contractor compliance with extensive design standards, TCEQ regulations for public water systems, AWWA standards, traffic control requirements, trench safety plans, storm water pollution prevention protocols, and comprehensive utility coordination procedures. Key specifications include hydrostatic testing requirements, disinfection and flushing protocols per AWWA C-651, pipe material certifications to ANSI/NSF standards, minimum cover requirements of 24 inches below ground surface, and detailed joint bonding and cathodic protection procedures. The contractor shall be responsible for all costs related to utility coordination, traffic control, trench safety, environmental compliance, as-built documentation, and restoration of disturbed areas.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WEST LUBBOCK WATER SYSTEM EXPANSION
100% SUBMITTAL
2575 S. Loop 289 Suite 103 Lubbock, Texas 79423 Phone - (806) 686-2700 Web - www.freese.com
MARK MCBRAYER
MAYOR
W. JARRETT ATKINSON
CITY MANAG
DAVID BRAGG, P.E.
INTERIM DIRECTOR OF PUBLIC WORKS
JOHN TURPIN, P.E.
DIVISION DIRECTOR OF ENGINEERING/CITY ENGINEER
PIPELINE
CONSTRUCTION PLANS FOR
CITY OF LUBBOCK, TEXAS
Executive Committee:
JANUARY 2026
WALTER PISHKUR
DIRECTOR OF WATER UTILITIES
KERRY KOEHLER, P.E.
ASSISTANT CITY ENGINEER
01/14/2026
DAVID BRAGG, P.E.
INTERIM DIRECTOR OF PUBLIC WORKS
26TH ST
19TH ST LEVELLAND HWY
4TH ST
ERSKINE ST CR6500
URSLINE ST CR 6400
U
PL
AN
D
AV
E
M
IL
W
AU
KE
E
AV
E
AL
CO
VE
A
VE
AUBURN ST
34TH ST CR 6800
CITY LIMITS
CITY LIMITS
CITY LIMITS
98th ST
M
IL
W
AU
KE
E
AV
E
66TH ST
82nd ST
LUBBOCK WESTERN & RAILWAY
PROPOSED PUMP
STATION 17 PROJECT SITE
(BY OTHERS)
EXISTING BAILEY COUNTY
WELL FIELD SUPPLY PIPELINE
EXISTING
PUMP
STATION 16
EXISTING LOW
HEAD C PIPELINE
EXISTING LOW HEAD C
PUMP STATION
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
AS
AJ
DW
S
M
AM
G-1
VI
CI
N
IT
Y M
AP
, I
N
DE
X
AN
D
LE
GE
N
D
CI
VI
L
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig in al
IS
SU
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:53 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-ALL-GN-VMAP01.dwg
CV
-A
LL
-G
N -V
M
AP
.d w g
La st
S av ed : 1
1/
/2
8:
A
M
Sa ve d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-A
LL
-G
N -V
M
AP
.d w g
AC
AD
R el
: 2 5.
1s (L
M S
Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
CREEK OR DRAINAGE PATH
IRON ROD
BORING
PROPERTY LINE AND / OR R.O.W.
LIMITS OF PERMANENT EASEMENT
LIMITS OF TEMPORARY EASEMENT
ASPHALT PAVING
CHAIN LINK OR WOOD FENCE
TREE
MONUMENT
SURVEY CONTROL POINT
SIGN
TELEPHONE PEDESTAL
GUY WIRE AND ANCHOR
POWER POLE
UNDERGROUND WATERLINE
OVERHEAD ELECTRIC
FIRE HYDRANT
P.I.
UNDERGROUND ELECTRIC
CUT/FILL AREA ON PIPELINE (PROFILE)
UNDERGROUND TELEPHONE
BRICKCRETE SCREEN FENCE
PROPOSED ASPHALT PAVEMENT
CUT/FILL AREA ON PIPELINE (PROFILE)
CUT FILL
UNDERGROUND SANITARY SEWER
VICINITY MAP
SCALE IN FEET
0 3000 60001500
NORTH
PROPOSED PIPELINE
GAS LINE
FLEXBASE PAVING REPLACEMENT
GRAVEL DRIVEWAY REPLACEMENT
FINAL
GRADE
CONCRETE PAVEMENT REPLACEMENT
PAVING REPLACEMENT
Sequence Sheet Sheet Title/Description
COVER SHEET
GENERAL
1 G-1 VICINITY MAP, INDEX AND LEGEND
2 G-2 GENERAL NOTES
3 G-3 SURVEY CONTROL POINTS
4 G-4 SUE TEST HOLES AND GEOTECHNICAL BORES
PIPELINE PLAN AND PROFILE
5 WL-1 26TH ST AND YUMA AVE STA 1+00 TO STA 8+00
6 WL-2 26TH ST AND YUMA AVE STA 8+00 TO STA 16+00
7 WL-3 26TH ST AND YUMA AVE STA 16+00 TO STA 23+00
8 WL-4 26TH ST AND YUMA AVE STA 23+00 TO STA 30+00
9 WL-5 26TH ST AND YUMA AVE STA 30+00 TO STA 37+50
10 WL-6 26TH ST AND YUMA AVE STA 37+50 TO STA 45+00
11 WL-7 26TH ST AND YUMA AVE STA 45+00 TO STA END
12 WL-8 29TH ST STA 1+00 TO END
13 WL-9 ALCOVE AVE START TO STA 9+50
14 WL-10 ALCOVE AVE 9+50 TO STA 19+00
15 WL-11 ALCOVE AVE 19+00 TO STA 28+00
16 WL-12 ALCOVE AVE 28+00 TO STA 37+50
17 WL-13 ALCOVE AVE 37+50 TO STA 47+00
18 WL-14 ALCOVE AVE 47+00 TO STA 56+50
19 WL-15 ALCOVE AVE 56+50 TO STA 66+00
20 WL-16 ALCOVE AVE 66+00 TO STA 75+50
21 WL-17 ALCOVE AVE 75+50 TO STA 85+00
22 WL-18 ALCOVE AVE 85+00 TO STA 94+00
23 WL-19 ALCOVE AVE 94+00 TO STA 102+00
24 WL-20 ALCOVE AVE 102+00 TO END
PAVEMENT
25 PV-1 YUMA AVE PAVING HORIZONTAL ALIGN DATA AND TYPICAL SECTIONS
26 PV-2 YUMA AVE PAVING REMOVAL PLAN
27 PV-3 YUMA AVE PAVING PLAN AND PROFILE (1 OF 2)
28 PV-4 YUMA AVE PAVING PLAN AND PROFILE (2 OF 2)
29 PV-5 YUMA AVE PAVING INTERSECTION LAYOUTS
DETAILS
30 DT-1 TRENCH DETAILS
31 DT-2 PIPE JOINT DETAILS
32 DT-3 TUNNEL DETAILS
33 DT-4 APPURTENANCE DETAILS
34 DT-5 BUTTERFLY VALVE VAULT DETAILS
35 DT-6 MANHOLE COVER DETAILS
36 DT-7 PIPELINE MARKER DETAILS
37 DT-8 THRUST RESTRAINT
38 DT-9 ROAD PAVING DETAILS
39 DT-10 LOW HEAD C PIPELINE CONNECTION DETAILS
40 DT-11 19TH STREET CROSSING
41 DT-12 26TH STREET BYPASS LINE
42 DT-12 LUBBOCK STANDARD DETAILS I
43 DT-13 LUBBOCK STANDARD DETAILS II
44 DT-14 LUBBOCK STANDARD DETAILS III
45 DT-15 LUBBOCK STANDARD DETAILS IV
46 DT-16 LUBBOCK STANDARD DETAILS V
CATHODIC PROTECTION
47 CP-1 YARD PIPING PLAN - CATHODIC PROTECTION
48 CP-2 YARD PIPING I - CATHODIC PROTECTION
49 CP-3 YARD PIPING II - CATHODIC PROTECTION
50 CP-4 YARD PIPING III - CATHODIC PROTECTION
51 CP-5 CATHODIC PROTECTION DETAILS I
52 CP-6 CATHODIC PROTECTION DETAILS II
53 CP-7 CATHODIC PROTECTION DETAILS III
54 CP-8 CATHODIC PROTECTION DETAILS IV
/1
4/
PIPLINE GENERAL NOTES
1. CLEARING AND GRUBBING MAY BEGIN NO SOONER THAN ONE MONTH
PRIOR TO PIPE TRENCHING OPERATIONS. PIPE STRINGING SHALL BE NO
MORE THAN ONE MONTH PRIOR TO PIPE LAYING. BACKFILL, CLEAN-UP,
AND SURFACE RESTORATION SHALL BE COMPLETED NO MORE THAN ONE
MONTH AFTER PIPE LAYING. THE SITE SHALL BE KEPT CLEAN OF TRASH AT
ALL TIMES. FAILURE TO COMPLY WITH THESE REQUIREMENTS MAY
RESULT IN WITHHOLDING SOME OR ALL PAYMENT TO THE CONTRACTOR.
2. CONTRACTOR SHALL DISPOSE OF OFFSITE ALL EXCESS MATERIAL,
CONSTRUCTION, RUBBLE, AND TRASH.
3. NO BLASTING IS ALLOWED.
4. REMOVE ROCK FROM THE DISTURBED AREAS SUCH THAT IT IS LEFT WITH
NO MORE QUANTITY OR SIZE OF ROCK THAN THE ADJACENT LAND.
5. CONTRACTOR WILL BE REQUIRED TO PREPARE AND SUBMIT A TRAFFIC
CONTROL PLAN (TCP) TO THE CITY OF LUBBOCK FOR REVIEW AND
APPROVAL PRIOR TO CONSTRUCTION STARTING. TCP TO BE SEALED BY A
LICENSED PROFESSIONAL ENGINEERING REGISTERED IN THE STATE OF
TEXAS. CONTRACTOR SHALL FOLLOW THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (TMUTCD) AND ALL
CITY RULES AND REGULATIONS.
6. CONTRACTOR SHALL MAINTAIN AT LEAST ONE LANE OF TRAFFIC ON ALL
PRIVATE, CITY AND COUNTY ROADS AT ALL TIMES, AND CONSTRUCT
TEMPORARY BYPASS IF NECESSARY.
7. CONTRACTOR SHALL PROVIDE APPROPRIATE SIGNAGE, BARRICADES,
FLAGMEN, ETC. REQUIRED TO MAINTAIN SAFE TRAFFIC FLOW AT ALL
TIMES. ALL TRAFFIC CONTROL MEASURES SHALL BE IN ACCORDANCE WITH
TXDOT'S MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES.
8. LOCATIONS OF CORROSION MONITORING AND CATHODIC PROTECTION
FACILITIES SHALL BE AS SHOWN IN THE SCHEDULE IN THE DETAIL SHEETS.
9. CONTRACTOR SHALL ABIDE BY ALL APPLICABLE GOVERNMENTAL AND
REGULATORY STANDARDS AND REQUIREMENTS AND OBTAIN ALL
NECESSARY PERMITS AND APPROVALS FOR CONSTRUCTION OF THE
PIPELINE FACILITIES SHOWN IN THE PLANS.
10.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING GENERAL SAFETY
AT AND ADJACENT TO THE PROJECT AREA, INCLUDING THE PERSONAL
SAFETY OF THE CONSTRUCTION STAFF AND THE GENERAL PUBLIC, AND
FOR THE SAFETY OF PUBLIC AND PRIVATE PROPERTY.
11.CONTRACTOR IS RESPONSIBLE FOR ALL TRENCH SAFETY. THE
CONTRACTOR SHALL CONSTRUCT THE PROPOSED WORK UTILIZING A
TRENCH SAFETY PLAN PREPARED, SIGNED AND SEALED BY A
PROFESSIONAL ENGINEER IN THE STATE OF TEXAS FOR THIS PROJECT. THIS
TRENCH SAFETY PLAN SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO
ANY WORK ACTIVITIES.
12.CONTRACTOR SHALL PROVIDE A STORM WATER POLLUTION PREVENTION
PLAN SIGNED AND SEALED BY A TEXAS PROFESSIONAL ENGINEER AND
PROVIDE ALL APPURTENANCES TO COMPLY WITH THE LATEST TCEQ
STORM WATER POLLUTION PREVENTION REGULATIONS. CONTRACTOR
SHALL BE RESPONSIBLE FOR FILING A NOTICE OF INTENT (NOI) AT THE
START OF CONSTRUCTION WITH THE TCEQ AND THE CITY OF LUBBOCK
AND A NOTICE OF TERMINATION (NOT) AT THE END. THE CONTRACTOR
SHALL SUBMIT THE SWPPP AND NOI TO THE CITY FOR REVIEW, APPROVAL,
AND SIGNATURE PRIOR TO ANY FIELD WORK.
13.THE CONTRACTOR SHALL EMPLOY ADEQUATE METHODS TO MINIMIZE
TURBIDITY IN WATERWAYS DURING ALL PHASES OF THE PROJECT. THE
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LAWS AND
REGULATIONS CONCERNING WATER POLLUTION PREVENTION.
14.CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE
MEASURES FOR PREVENTING STORM WATER RUNOFF FROM ENTERING
THE TRENCH DURING CONSTRUCTION.
15.CONTRACTOR SHALL NOTIFY TXDOT OF THE CONSTRUCTION SCHEDULE OF
ALL TUNNELS TO BE INSTALLED WITHIN STATE HIGHWAYS AND
ROADWAYS. NOTIFY TXDOT AT LEAST 48 HOURS PRIOR TO STARTING
CONSTRUCTION SO THAT TXDOT CAN HAVE A REPRESENTATIVE PRESENT.
CONTRACTOR SHALL COMPLY WITH ALL OF THE REQUIREMENTS OF THE
CROSSING PERMITS ATTACHED TO THE PROJECT SPECIFICATION.
16.CONSTRUCTION SURVEYING IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR INCLUDING BUT NOT LIMITED TO LIMITS OF PERMANENT
EASEMENT, TEMPORARY EASEMENT, CENTERLINE, ETC. THE CONTRACTOR
SHALL VERIFY ALL CONTROL MONUMENTATION PRIOR TO BEGINNING
CONSTRUCTION.
17.CONTRACTOR SHALL PROVIDE THE OWNER AS-BUILT LOCATIONS AND
ELEVATIONS OF APPURTENANCES, INCLUDING BUT NOT LIMITED TO AIR
RELEASE, AIR/VACUUM, AND BLOW OFF VALVES, MANHOLE COVERS,
IN-LINE VALVES, CORROSION TEST STATIONS, CONNECTIONS AND
OUTLETS. CONTRACTOR SHALL ALSO PROVIDE AS-BUILT TOP-OF-PIPE
SURVEY FOR EVERY 100-FEET OF PIPE AND ALL FITTINGS AS IT IS BEING
LAID INCLUDING STATION AND ELEVATION INFORMATION. AS-BUILT DATA
SHALL BE PROVIDED WITH THE REQUEST FOR PAYMENT FOR THESE ITEMS.
18.CONTRACTOR SHALL BE REQUIRED TO INSTALL TEMPORARY TEST PLUGS
FOR HYDROSTATIC TESTING AS NECESSARY AT NO ADDITIONAL COST TO
THE OWNER.
19.ALL ABOVE GROUND METAL SHALL BE PAINTED OR COATED ACCORDING
TO THE SPECIFICATIONS. CONTRACTOR SHALL COORDINATE THE COLORS
WITH THE OWNER.
20.VARIOUS LOCATIONS OF THE WORK ARE SUBJECT TO FLOODING OR
STANDING WATER DURING WET WEATHER PERIODS. CONTRACTOR SHALL
PLAN THIS WORK FOR DRY WEATHER PERIODS OR PROVIDE DEWATERING
AND OTHER WET WEATHER PROVISIONS AS INCIDENTAL WORK.
21.CONTRACTOR SHALL COORDINATE HIS PROPOSED CONSTRUCTION WITH
OTHER CONTRACTORS IN THE EVENT THE OTHER CONTRACTORS ARE
DOING WORK IN THE SAME AREA SIMULTANEOUSLY WITH HIS PROJECT.
THIS INCLUDES, BUT IS NOT LIMITED TO, ALL CONNECTION POINTS OR
OTHER SPECIAL ITEMS AS REQUIRED FOR TESTING.
22.IN ACCORDANCE WITH TEXAS STATE LAW, AT LEAST 2 DAYS PRIOR TO
BEGINNING EXCAVATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
NOTIFYING A TEXAS REGISTERED NOTIFICATION CENTER (I.E. TEXAS ONE
CALL, DIG TESS, ETC.), IN ORDER TO HAVE EXISTING UTILITIES LOCATED.
23.CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS WITHIN THE
CONSTRUCTION SITE AS PER THE EASEMENT REQUIREMENTS ASSOCIATED
WITH THE PROJECT AND ANY OTHER REQUIREMENTS SHOWN ON THE
PLANS. IF NOT OTHERWISE SPECIFIED, ALL STREETS, DRIVEWAYS, FENCING,
LANDSCAPING, ETC. SHALL BE RETURNED TO A CONDITION EQUAL TO OR
BETTER THAN EXISTED PRIOR TO CONSTRUCTION.
24.THE CONTRACTOR SHALL PROVIDE DETAILED PHOTOS AND VIDEOS TO
THE OWNER DOCUMENTING THE CONDITION OF THE PIPELINE ROUTE,
INCLUDING THE PERMANENT EASEMENT, TEMPORARY EASEMENT AND
SURROUNDING AREA. CONTRACTOR SHALL REVIEW PHOTOS WITH THE
OWNER PRIOR TO THE START OF ANY CONSTRUCTION.
25.THE CONTRACTOR SHALL RESTORE, AT HIS OWN EXPENSE, TEMPORARY
ROADS AND CONSTRUCTION WORK AREAS TO PRE-CONSTRUCTION
CONDITIONS.
26.THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHOWN IN THE
PLANS ARE APPROXIMATE ONLY AND SHOULD BE VERIFIED BY THE
CONTRACTOR BEFORE COMMENCING WORK. CONTRACTOR IS FULLY
RESPONSIBLE FOR ANY AND ALL DAMAGES RESULTING FROM FAILURE TO
EXACTLY LOCATE AND PRESERVE THE UNDERGROUND UTILITIES.
27.CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES
PRIOR TO MANUFACTURING OF PIPE AND SUFFICIENTLY IN ADVANCE OF
THE CONSTRUCTION SO THAT IF IT IS NECESSARY TO CHANGE OR MOVE
THE UTILITY, THE PROGRESS OF THE WORK WILL NOT BE DELAYED. ANY
EXISTING UTILITY DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED
OR REPLACED IMMEDIATELY WITH LIKE OR BETTER MATERIALS.
28.CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF ALL POWER AND
TELEPHONE POLES AND GUY WIRES WITHIN 15 FEET OF PROPOSED WATER
LINE AND SHALL REPAIR DAMAGED POLES AND GUY WIRES OR RELOCATE
POLES AND GUY WIRES AS REQUIRED BY THE UTILITY OWNER AT NO
ADDITIONAL COST TO THE OWNER.
29.THE CONTRACTOR MAY NOT USE PRIVATELY OWNED ROADS UNLESS HE
OBTAINS PERMISSION FROM THE LAND OWNERS. CONTRACTOR SHALL
REPAIR ANY DAMAGE TO PRIVATE ROADS.
30.NO MOUNDING IS ALLOWED IN ROADS. WITHIN ROADS, UPON
COMPLETION OF CONSTRUCTION, THE ENTIRE EASEMENT AREA SHALL BE
LEVELED TO GRADE.
31.THE MAXIMUM OPEN TRENCH LENGTH IS 150 FEET FOR POPULATED
AREAS OR OTHER AREAS DESIGNATED ON THE PLAN AND PROFILE SHEETS.
OPEN TRENCH WILL NOT BE ALLOWED IN ROADWAYS AND POPULATED
AREAS OVERNIGHT. ALL OPEN PITS MUST BE PROTECTED ON ALL SIDES
WITH CONCRETE BARRIERS OR BACKFILLED FOR PUBLIC SAFETY.
32.PRIOR TO COMMENCEMENT OF CONSTRUCTION THE CONTRACTOR SHALL
STAKE THE EXTERIOR BOUNDARIES OF THE PERMANENT AND TEMPORARY
EASEMENT.
33.THE CONTRACTOR IS TO SURVEY IN LOCATION, DEPTH, SIZE, PIPE
MATERIAL AND IF POSSIBLE UTILITY OWNER OF ALL UTILITY CROSSINGS
ALONG THE PIPELINE. THIS ITEM WILL BE REVIEWED EACH MONTH ALONG
WITH THE AS-BUILTS BEFORE APPROVAL OF THE PAY ESTIMATE.
34.ALL UTILITIES KNOWN OR UNKNOWN ARE THE RESPONSIBILITY OF THE
CONTRACTOR. NO EXTRA PAYMENT WILL BE GIVEN FOR UTILITIES
ENCOUNTERED THAT ARE NOT SHOWN IN THE DRAWINGS.
35.CONTRACTOR SHALL REPAIR AND REPAVE EACH CITY STREET, WITHIN 14
DAYS UPON COMPLETION OF ALL PIPE LAYING ACTIVITIES FOR EACH
STREET. (I.E. WHEN CONTRACTOR LEAVES ONE STREET TO PRIVATE
PROPERTY OR TO ANOTHER STREET, THE STREET MUST BE REPAVED.) PIPE
LAYING ACTIVITIES INCLUDE, PIPE INSTALLATION, BEDDING AND BACKFILL
THE FULL HEIGHT OF THE TRENCH, MANHOLE INSTALLATIONS, CONCRETE
AND FLOWABLE FILL ENCASEMENTS, AND APPURTENANCES.
36.WHEN THE PIPELINE ROW CROSSES DRIVEWAY, MAILBOXES, SIGNS,
RESIDENTIAL FENCES, THE CONTRACTOR SHALL REPAIR OR REPLACE ITEMS
THAT WERE DAMAGED WITH LIKE OR BETTER MATERIALS AND
CONDITIONS.
37.IF CONTRACTOR DAMAGES EXISTING ASPHALT OR CONCRETE PAVING
OUTSIDE OF THE REPLACEMENT LIMITS SHOWN IN THE DRAWINGS, IT
WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE
THE DAMAGED ASPHALT OR CONCRETE PAVEMENT THAT WAS DAMAGED
WITH LIKE OR BETTER MATERIAL AND CONDITIONS AND NO SEPARATE
PAYMENT WILL BE MADE.
38.ALL VALVE COVERS, VAULT LIDS, AND ANY APPURTENANCES LOCATED IN
PAVEMENT SHALL BE FINISHED AT GRADE. TRAFFIC RATED COVERS AND
LIDS ARE TO BE USED.
40.PIPELINE/CATHODIC PROTECTION CONTRACTOR SHALL COORDINATE WITH
PUMP STATION/GST CONTRACTOR TO INSTALL CATHODIC PROTECTION
TEST STATIONS ON THE YARD PIPING. YARD PIPING TO BE INSTALLED BY
PUMP STATION/GST CONTRACTOR.
41.SURVEY NOTE:
THE COORDINATE SYSTEM USED FOR THIS SURVEY IS NAD83 TEXAS
STATEPLANES, NORTH CENTRAL ZONE, U.S. FOOT (TX83-NCF)
SCALE FACTOR = 0.999760057586179
TCEQ WATER DISTRIBUTION SYSTEM
GENERAL CONSTRUCTION NOTES (REVISED 02-2019)
1. THIS WATER DISTRIBUTION SYSTEM MUST BE CONSTRUCTED IN
ACCORDANCE WITH THE CURRENT TEXAS COMMISSION ON
ENVIRONMENTAL QUALITY (TCEQ) RULES AND REGULATIONS FOR PUBLIC
WATER SYSTEMS 30 TEXAS ADMINISTRATIVE CODE (TAC) CHAPTER 290
SUBCHAPTER D. WHEN CONFLICTS ARE NOTED WITH LOCAL STANDARDS,
THE MORE STRINGENT REQUIREMENT SHALL BE APPLIED. AT A MINIMUM,
CONSTRUCTION FOR PUBLIC WATER SYSTEMS MUST ALWAYS MEET
TCEQ'S "RULES AND REGULATIONS FOR PUBLIC WATER SYSTEMS.”
2. ALL NEWLY INSTALLED PIPES AND RELATED PRODUCTS MUST CONFORM
TO AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)/NSF
INTERNATIONAL STANDARD 61 AND MUST BE CERTIFIED BY AN
ORGANIZATION ACCREDITED BY ANSI [§290.44(A)(1)].
3. PLASTIC PIPE FOR USE IN PUBLIC WATER SYSTEMS MUST BEAR THE NSF
INTERNATIONAL SEAL OF APPROVAL (NSF-PW) AND HAVE AN ASTM
DESIGN PRESSURE RATING OF AT LEAST 150 PSI OR A STANDARD
DIMENSION RATIO OF 26 OR LESS [§290.44(A)(2)].
4. NO PIPE WHICH HAS BEEN USED FOR ANY PURPOSE OTHER THAN THE
CONVEYANCE OF DRINKING WATER SHALL BE ACCEPTED OR RELOCATED
FOR USE IN ANY PUBLIC DRINKING WATER SUPPLY [§290.44(A)(3)].
5. ALL WATER LINE CROSSINGS OF WASTEWATER MAINS SHALL BE
PERPENDICULAR [§290.44(E)(4)(B)].
6. WATER TRANSMISSION AND DISTRIBUTION LINES SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. HOWEVER,
THE TOP OF THE WATER LINE MUST BE LOCATED BELOW THE FROST LINE
AND IN NO CASE SHALL THE TOP OF THE WATER LINE BE LESS THAN 24
INCHES BELOW GROUND SURFACE [§290.44(A)(4)].
7. THE MAXIMUM ALLOWABLE LEAD CONTENT OF PIPES, PIPE FITTINGS,
PLUMBING FITTINGS, AND FIXTURES IS 0.25 PERCENT [§290.44(B)].
8. THE CONTRACTOR SHALL INSTALL APPROPRIATE AIR RELEASE DEVICES
WITH VENT OPENINGS TO THE ATMOSPHERE COVERED WITH 16-MESH OR
FINER, CORROSION RESISTANT SCREENING MATERIAL OR AN ACCEPTABLE
EQUIVALENT [§290.44(D)(1)].
9. THE CONTRACTOR SHALL NOT PLACE THE PIPE IN WATER OR WHERE IT
CAN BE FLOODED WITH WATER OR SEWAGE DURING ITS STORAGE OR
INSTALLATION [§290.44(F)(1)].
10. WHEN WATERLINES ARE LAID UNDER ANY FLOWING OR INTERMITTENT
STREAM OR SEMI-PERMANENT BODY OF WATER THE WATERLINE SHALL BE
INSTALLED IN A SEPARATE WATERTIGHT PIPE ENCASEMENT. VALVES MUST
BE PROVIDED ON EACH SIDE OF THE CROSSING WITH FACILITIES TO
ALLOW THE UNDERWATER PORTION OF THE SYSTEM TO BE ISOLATED AND
TESTED [§290.44(F)(2)].
11.PURSUANT TO 30 TAC §290.44(A)(5), THE HYDROSTATIC LEAKAGE RATE
SHALL NOT EXCEED THE AMOUNT ALLOWED OR RECOMMENDED BY THE
MOST CURRENT AWWA FORMULAS FOR STEEL OR BAR-WRAPPED PIPE.
INCLUDE THE FORMULAS IN THE NOTES ON THE PLANS.
O THE HYDROSTATIC LEAKAGE RATE FOR POLYVINYL CHLORIDE (PVC)
PIPE AND APPURTENANCES SHALL NOT EXCEED THE AMOUNT
ALLOWED OR RECOMMENDED BY FORMULAS IN AMERICA WATER
WORKS ASSOCIATION (AWWA) C-605 AS REQUIRED IN 30 TAC
§290.44(A)(5). PLEASE ENSURE THAT THE FORMULA FOR THIS
CALCULATION IS CORRECT AND MOST CURRENT FORMULA IS IN
USE;
WHERE: Q= LD√P
148,000
§ Q = THE QUANTITY OF MAKEUP WATER IN GALLONS PER HOUR, L
= THE LENGTH OF THE PIPE SECTION BEING TESTED, IN FEET, D =
THE NOMINAL DIAMETER OF THE PIPE IN INCHES, AND P = THE
AVERAGE TEST PRESSURE DURING THE HYDROSTATIC TEST IN
POUNDS PER SQUARE INCH (PSI).
O THE HYDROSTATIC LEAKAGE RATE FOR DUCTILE IRON (DI) PIPE AND
APPURTENANCES SHALL NOT EXCEED THE AMOUNT ALLOWED OR
RECOMMENDED BY FORMULAS IN AMERICA WATER WORKS
ASSOCIATION (AWWA) C-600 AS REQUIRED IN 30 TAC
§290.44(A)(5). PLEASE ENSURE THAT THE FORMULA FOR THIS
CALCULATION IS CORRECT AND MOST CURRENT FORMULA IS IN
USE;
WHERE: L= SD√P
148,000
§ L = THE QUANTITY OF MAKEUP WATER IN GALLONS PER HOUR, S
= THE LENGTH OF THE PIPE SECTION BEING TESTED, IN FEET, D =
THE NOMINAL DIAMETER OF THE PIPE IN INCHES, AND P = THE
AVERAGE TEST PRESSURE DURING THE HYDROSTATIC TEST IN
POUNDS PER SQUARE INCH (PSI).
12. THE CONTRACTOR SHALL MAINTAIN A MINIMUM SEPARATION DISTANCE
IN ALL DIRECTIONS OF NINE FEET BETWEEN THE PROPOSED WATERLINE
AND WASTEWATER COLLECTION FACILITIES INCLUDING MANHOLES. IF
THIS DISTANCE CANNOT BE MAINTAINED, THE CONTRACTOR MUST
IMMEDIATELY NOTIFY THE PROJECT ENGINEER FOR FURTHER DIRECTION.
SEPARATION DISTANCES, INSTALLATION METHODS, AND MATERIALS
UTILIZED MUST MEET §290.44(E)(1)-(4).
13. THE SEPARATION DISTANCE FROM A POTABLE WATERLINE TO A
WASTEWATER MAIN OR LATERAL MANHOLE OR CLEANOUT SHALL BE A
MINIMUM OF NINE FEET. WHERE THE NINE-FOOT SEPARATION DISTANCE
CANNOT BE ACHIEVED, THE POTABLE WATERLINE SHALL BE ENCASED IN A
JOINT OF AT LEAST 150 PSI PRESSURE CLASS PIPE AT LEAST 18 FEET LONG
AND TWO NOMINAL SIZES LARGER THAN THE NEW CONVEYANCE. THE
SPACE AROUND THE CARRIER PIPE SHALL BE SUPPORTED AT FIVE-FOOT
INTERVALS WITH SPACERS OR BE FILLED TO THE SPRINGLINE WITH
WASHED SAND. THE ENCASEMENT PIPE SHALL BE CENTERED ON THE
CROSSING AND BOTH ENDS SEALED WITH CEMENT GROUT OR
MANUFACTURED SEALANT [§290.44(E)(5)].
14. FIRE HYDRANTS SHALL NOT BE INSTALLED WITHIN NINE FEET VERTICALLY
OR HORIZONTALLY OF ANY WASTEWATER LINE, WASTEWATER LATERAL,
OR WASTEWATER SERVICE LINE REGARDLESS OF CONSTRUCTION
[§290.44(E)(6)].
15. SUCTION MAINS TO PUMPING EQUIPMENT SHALL NOT CROSS
WASTEWATER MAINS, WASTEWATER LATERALS, OR WASTEWATER
SERVICE LINES. RAW WATER SUPPLY LINES SHALL NOT BE INSTALLED
WITHIN FIVE FEET OF ANY TILE OR CONCRETE WASTEWATER MAIN,
WASTEWATER LATERAL, OR WASTEWATER SERVICE LINE [§290.44(E)(7)].
16. WATERLINES SHALL NOT BE INSTALLED CLOSER THAN TEN FEET TO
SEPTIC TANK DRAINFIELDS [§290.44(E)(8)].
17. THE CONTRACTOR SHALL DISINFECT THE NEW WATERLINES IN
ACCORDANCE WITH AWWA STANDARD C-651-14 OR MOST RECENT,
THEN FLUSH AND SAMPLE THE LINES BEFORE BEING PLACED INTO
SERVICE. SAMPLES SHALL BE COLLECTED FOR MICROBIOLOGICAL
ANALYSIS TO CHECK THE EFFECTIVENESS OF THE DISINFECTION
PROCEDURE WHICH SHALL BE REPEATED IF CONTAMINATION PERSISTS.
A MINIMUM OF ONE SAMPLE FOR EACH 1,000 FEET OF COMPLETED
WATERLINE WILL BE REQUIRED OR AT THE NEXT AVAILABLE SAMPLING
POINT BEYOND 1,000 FEET AS DESIGNATED BY THE DESIGN ENGINEER
[§290.44(F)(3)].
18. DECHLORINATION OF DISINFECTING WATER SHALL BE IN STRICT
ACCORDANCE WITH CURRENT AWWA STANDARD C655-09 OR MOST
RECENT.
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
G-2
GE
N
ER
AL
N O
TE
S
CI
VI
L
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:54 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-ALL-GN-NOTE01.dwg
CV
-A
LL
-G
N -N
O
TE
.d w g
La st
S av ed : 1
2/
/2
2:
P d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-A
LL
-G
N -N
O
TE
.d w g
AC
AD
R el
: 2 5.
1s (L
M S
Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
TCEQ NOTES INDICATED ARE THE
MINIMUM CRITERIA. WHEN NOTES
ARE IN CONFLICT WITH THE
DRAWINGS AND SPECIFICATIONS,
THE MOST STRINGENT
REQUIREMENTS WILL APPLY AS
DETERMINED BY THE ENGINEER.
/1
4/
FH
FH
FH
W
ELL
W
ELL
FH
FH
FH
FH FH
FH
FH
FH
C7, Q
L"B"
20' UNDERGROUND UTILITY EASEMENT TO BE GRANTED BY SEPARATEINSTRUMENT
P.O.B.N= 7,271,923.73'
E= 907,471.48'
PPPP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
PP
PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
PP
PP
PP
PP
PP
PP
0+54 5+00 10+00 15+00 20+00 25+00 30+00 35+00 40+00 45+00 50+00 55+00 60+00 65+00 70+00 75+00 80+00 85+00 90+00 95+00 100+00 105+00
1+
5+
8+
5+
+0
+0
+0
+0
+0
+0
40+0045+00
ST
S
TR
EE
T
VIRGINIA AVENUE
VIOLA AVENUE
WINFIELD AVENUE
TH
S
TR
EE
T
WAUSAU AVENUE
ALLEYWAY
ALLEYWAY
VENITA AVENUE
WAUSAU AVENUE
TH
S
TR
EE
T
TH
S
TR
EE
T
HW
Y
TH
S
TR
EE
T 4T
H
ST
RE
ET
YUMA AVENUE
TH
S
TR
EE
T
N
D
ST
RE
ET
N COUNTY ROAD 1500
TH
S
TR
EE
T
TH
S
TR
EE
T
URBANA PLACE
UPLAND AVENUE
URBANA PLACE
VENITA AVENUE
YUKON AVENUE
TH
S T
TH
S T
ST
S T
LU
BB
OC
K
W
ES
TE
RN
R
AI
LW
AY
ALCOVE AVENUE
ALCOVE AVENUE
ALCOVE AVENUE
CONTROL POINT
CP-1
CONTROL POINT
CP-2
CONTROL POINT
CP-3
CONTROL POINT
CP-4
CONTROL POINT
CP-5
CONTROL POINT
CP-6
CONTROL POINT
CP-7
CONTROL POINT
CP-8CONTROL POINT
CP-9
CONTROL POINT
CP-10
CONTROL POINT
CP-11
CONTROL POINT
CP-12
CONTROL POINT
CP-13
CONTROL POINT
CP-14
CONTROL POINT
CP-15
CONTROL POINT
CP-16
CONTROL POINT
CP-17
CONTROL POINT
CP-18
CONTROL POINT
CP-19
PS #17 &
GST SITE
CONTROL POINT TABLE
POINT
CP-1
CP-2
CP-3
CP-4
CP-5
CP-6
CP-7
CP-8
CP-9
CP-10
CP-11
CP-12
CP-13
CP-14
CP-15
CP-16
CP-17
CP-18
CP-19
NORTHING
7281558.08
7280227.08
7278896.17
7277560.68
7276317.12
7274995.27
7273667.62
7272336.82
7271134.90
7272434.14
7272816.71
7273202.03
7272540.48
7272885.58
7273136.17
7273657.34
7273623.46
7273586.42
7273527.32
EASTING
905654.41
905614.03
905479.70
905517.26
905426.35
905361.53
905317.91
905352.16
905313.02
906307.85
906220.14
906140.19
906799.81
906811.89
906820.35
907328.90
908382.89
909543.10
910586.70
ELEVATION
3315.83
3311.89
3308.52
3301.68
3303.81
3309.66
3312.32
3307.72
3299.99
3303.02
3304.84
3306.36
3301.00
3302.45
3302.85
3293.78
3283.40
3280.61
3287.08
DESCRIPTION
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
ALUM. MONUMENT IN CONCRETE
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
G-3
SU
RV
EY
C
O N
TR
O
L
PO
IN
TS
CI
VI
L
N O
RTH
SCALE IN FEET
0 500 1000
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:54 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-CTRL01.dwg
CV
-P
PL
-P
P-
CT
RL
.d w g
La st
S av ed : 1
0/
/2
:4
AM
d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
CT
RL
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
NOTES:
1. CONTRACTOR SHALL VERIFY LOCATION
AND DEPTH OF ALL UTILITIES PRIOR TO
BEGINNING OF CONSTRUCTION.
2. THE EXISTENCE AND LOCATIONS OF
ALL KNOWN UNDERGROUND UTILITIES
SHOWN ON THE DRAWINGS WERE
OBTAINED FROM AVAILABLE RECORDS
AND LIMITED SURVEY DATA. THE
CONTRACTOR SHALL DETERMINE THE
DEPTH AND LOCATIONS OF EXISTING
UNDERGROUND UTILITIES PRIOR TO
TRENCHING AND SHALL BE REQUIRED
TO ANY PRECAUTIONARY MEASURES
TO PROTECT ALL UTILITIES SHOWN OR
NOT SHOWN IN THE PLANS
SURVEY NOTE:
THE COORDINATE SYSTEM USED FOR
THIS SURVEY IS NAD83 TEXAS STATE
PLANES, NORTH CENTRAL ZONE, U.S.
FOOT (TX83-NCF)
/1
4/
20' UNDERGROUND UTILITY EASEMENT TO BE GRANTED BY SEPARATEINSTRUMENT
TH
S
TR
EE
T
WAUSAU AVENUE
P.O.B.N= 7,271,923.73' E= 907,471.48'
VENITA AVENUE
TH
S
TR
EE
T
TH
S
TR
EE
T19
TH
S
TR
EE
T
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
FM
(4
TH
S
TR
EE
T)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
YUMA AVENUE
(ASPHALT PAVEMENT)
12TH STREET
N
D
ST
RE
ET
N COUNTY ROAD 1500
TO
W
ER GU
Y W
IRE
3 TRAN
SFO
RM
ERS
29TH STREET
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
URBANA PLACE
UPLAND AVENUE
(ASPHALT PAVEMENT)
URBANA PLACE
VENITA AVENUE
YUKON AVENUE
28TH STREET
29TH STREET
30TH STREET
31ST STREET
LU
BB
OC
K
W
ES
TE
RN
R
AI
LW
AY
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
TH
S
TR
EE
T
(A
SP
HA
LT
P
AV
EM
EN
T)
TH
S
TR
EE
T (A
SP
HA
LT
P
AV
EM
EN
T)
27ST STREET
VIRGINIA AVENUE
ALLEYWAY
VIOLA AVENUE
WINFIELD AVENUE
ALLEYWAY
E
WAUSAU AVENUE
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
ALCOVE AVENUE
(ASPHALT PAVEMENT)
YUMA AVENUE
(ASPHALT PAVEMENT)
YUMA AVENUE
(ASPHALT PAVEMENT)
PPPP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP
PP
PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP PP PP
PP
PP
PP
PP
PP
PP
GUY
GUY
GUY
G1, Q
L"D"
C7, Q
L"B"
ST
S
TR
EE
T
VIRGINIA AVENUE
VIOLA AVENUE
WINFIELD AVENUE
TH
S
TR
EE
T
WAUSAU AVENUE
ALLEYWAY
ALLEYWAY
VENITA AVENUE
WAUSAU AVENUE
TH
S
TR
EE
T
TH
S
TR
EE
T
TH
S
TR
EE
T
TH
S
TR
EE
T 4T
H
ST
RE
ET
YUMA AVENUE
TH
S
TR
EE
T
N
D
ST
RE
ET
N COUNTY ROAD 1500
TH
S
TR
EE
T
TH
S
TR
EE
T
URBANA PLACE
UPLAND AVENUE
URBANA PLACE
VENITA AVENUE
YUKON AVENUE
TH
S T
TH
S T
ST
S T
LU
BB
OC
K
W
ES
TE
RN
R
AI
LW
AY
ALCOVE AVENUE
ALCOVE AVENUE
ALCOVE AVENUE
PL-3
0+54 5+00 10+00 15+00 20+00 25+00 30+00 35+00 40+00 45+00 50+00 55+00 60+00 65+00 70+00 75+00 80+00 85+00 90+00 95+00 100+00 105+00
1+
5+
8+
5+
+0
+0
+0
+0
+0
+0
40+0045+00
PL-1
PL-2
BORING TABLE
POINT
NO.
BORING
NUMBER
PL-1
PL-2
PL-3
NORTHING
7271480.17
7276512.52
7281419.81
EASTING
905212.45
905492.26
905624.03
POINT
DESCRIPTION
PIPELINE
PIPELINE
PIPELINE
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
G-4
SU
E
TE
ST
H O
LE
S
AN
D
GE
O
TE
CH
N
IC
AL
B
O
RE
S
CI
VI
L
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:54 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-TEST01.dwg
CV
-P
PL
-P
P-
TE
ST
.d w g
La st
S av ed : 1
0/
/2
:4 d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
TE
ST
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
NOTES:
1. CONTRACTOR SHALL VERIFY LOCATION
AND DEPTH OF ALL UTILITIES PRIOR TO
BEGINNING OF CONSTRUCTION.
2. THE EXISTENCE AND LOCATIONS OF
ALL KNOWN UNDERGROUND UTILITIES
SHOWN ON THE DRAWINGS WERE
OBTAINED FROM AVAILABLE RECORDS
AND LIMITED SURVEY DATA. THE
CONTRACTOR SHALL DETERMINE THE
DEPTH AND LOCATIONS OF EXISTING
UNDERGROUND UTILITIES PRIOR TO
TRENCHING AND SHALL BE REQUIRED
TO ANY PRECAUTIONARY MEASURES
TO PROTECT ALL UTILITIES SHOWN OR
NOT SHOWN IN THE PLANS
SURVEY NOTE:
THE COORDINATE SYSTEM USED FOR
THIS SURVEY IS NAD83 TEXAS STATE
PLANES, NORTH CENTRAL ZONE, U.S.
FOOT (TX83-NCF)
N O
RTH
SCALE IN FEET
0 500 1000
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
LEGEND
BORING LOCATION
SUE TEST HOLE TABLE
Test Hole
Utility Size, O.D. (Inches)
Utility Material (Refer to Legend)
Utility Type (Refer to Legend)
Depth to Top of Utility (Feet)
Northing
(Y) Easting (X)
Ground Elevation
(Z)
Top of Utility
Elevation
SUE
Quality
Level
1 12 Polyvinyl Chloride Water 4.92 7279860.174 905430.353 3315.178 3310.26 QLA 2 2 Steel Gas 4.28 7279853.395 905418.539 3315.09 3310.81 QLA 3 UNKNOWN UNKNOWN Sanitary Sewer UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 4 8 Transite Water 6.20 7274691.818 905258.287 3302.441 3296.24 QLA
4A 1 UNKNOWN Fiber Optic Cable 5.24 7274692.162 905258.262 3302.344 3297.10 QLA 5 4 Steel Water 4.90 7274580.989 905254.402 3303.394 3298.49 QLA 6 3 Steel Gas 3.44 7274576.409 905248.136 3303.537 3300.10 QLA 7 6 Ductile Iron Water 5.64 7274264.988 905242.33 3305.23 3299.59 QLA 8 UNKNOWN UNKNOWN Gas UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 9 12 Polyvinyl Chloride Water 5.46 7269376.249 905020.344 3299.191 3293.73 QLA
10 UNKNOWN UNKNOWN Gas UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 11 UNKNOWN UNKNOWN Gas UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 12 UNKNOWN UNKNOWN Gas UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 13 8 Polyvinyl Chloride Water 5.51 7271854.047 909699.903 3281.74 3276.23 QLA 14 18 UNKNOWN Sanitary Sewer UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 15 10 Transite Water 4.22 7271845.585 910362.839 3285.868 3281.65 QLA
15A 8 Polyvinyl Chloride Water 4.38 7271835.847 910369.759 3285.893 3281.51 QLA 16 UNKNOWN UNKNOWN Gas UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN QLA 17 16 Transite Water 4.24 7271871.565 910400.135 3286.793 3282.55 QLA 18 4 Polyvinyl Chloride Fiber Optic Cable 4.30 7271975.325 906643.285 3301.193 3296.89 QLA
/1
4/
10 " AC
36"
8" P
VC
6" PVC
" A
C
NOT FOUND
IN RECORDS
NOT FOUND
IN RECORDS
NOT FOUND
IN RECORDSNOT FOUND
IN RECORDS
NOT FOUND
IN RECORDS
6" PVC
16" PVC FM
16" PVC FM
" P
VC
F
M
ENTERS MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD
ENDS AT MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD
6" PVC6" PVC
ENTERS MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD 18"
MAILBOX
MAILBOX MAILBOX MAILBOX
MAILBOX
32' RIGHT-OF-WAY EASEMENT (DEDICATED BY PLAT)
30' RIGHT-OF-WAY EASEMENT
(VOL: 473, PG: 315)
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
0.167 ACRE
7324 26TH ST
LUBBOCK, TX 79407
BRIAN ROSSER
5401 71ST
LUBBOCK TX 79424
(VOL: 9463, PG: 272)
0.175 ACRE
7302 26TH ST
LUBBOCK, TX 79407
KATHERINE BROWN
6327 CRAWFORD LN E
FOREST HILL TX 76119
(CCFN: 2012037498)
0.167 ACRE
JOSE & ANGEL
BOCANEGRA
7322 26TH ST
LUBBOCK, TX 79407
(VOL: 4225, PG: 247)
0.167 ACRE
UNKNOWN OWNER
(NO DOCUMENT
FOUND)
0.167 ACRE
EARLENE STANLEY
(NO DOCUMENT
FOUND)
0.167 ACRE
7310 26TH ST
LUBBOCK, TX 79407
SVEND BURNS
7305 25TH ST
LUBBOCK TX
79407-4337
(CCFN: 2002769031)
0.167 ACRE
ROSIE EVANS
ESTATE
214 CHERRY AVE
LUBBOCK TX 79403
(NO DOCUMENT
FOUND)
0.167 ACRE
7306 26TH ST
LUBBOCK, TX 79407
CLAUDE WILLIAMS
415 STONE CANYON DR
SUNNYVALE TX
75182-5021
(VOL: 6421, PG: 90)
0.167 ACRE
7304 26TH ST
LUBBOCK, TX 79407
CLAUDE WILLIAMS
415 STONE CANYON DR
SUNNYVALE TX
75182-5021
(CCFN: 2000006161)
0.167 ACRE
UNKNOWN OWNER
(NO DOCUMENT
FOUND)
0.167 ACRE
UNKNOWN OWNER
(NO DOCUMENT
FOUND)
0.167 ACRE
EARLENE STANLEY
ADDRESS UNKNOWN
(NO DOCUMENT
FOUND)
Vegetation Ground Obscured
E
LOTS 772-823
TRACTS K-M
(CCFN: 2021003474)
CP-19
STA 4+94.60
INSTALL:
1-CAV ASSEMBLY (RE: DT-4)
1-TYPE B TRAFFIC RATED VAULT LID
(RE: DT-6)
N: 7273567.07 E: 910257.99
STA 3+00.00
INSTALL:
1-36" BFV IN MANHOLE
(RE: DT-5)
N=7273560.33 E=910452.47
5'
WORK LIMITS
.7
'-1
3 4"
U
PL
AN
D
AV
EN
U E
(A
SP
HA
LT
P
AV
EM
EN
T)
26TH STREET
(ASPHALT PAVEMENT)
STA 1+00.00
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273553.41 E=910652.35
STA 1+00.00
TIE-IN TO EX 36" WATER LINE
(RE: DT-10)
1-INSULATING FLANGE KIT
(RE:1/CP-7)
N=7273553.41 E=910652.35
STA 0+89.56
INSTALL:
1-INSULATING JOINT TEST STATION
(RE:2/CP-7)
N=7273555.77 E=910662.88
1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00
1556 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
EX 30" BFV
EX BAILEY COUNTY 30" WL
EX 2" CAV
EX 16" AC WL EX F/O EX GAS
EX 8" PVC WL
EX 10" PVC WL
EX 16" PVC FM
EX 16" PVC FM
PROPOSED 36" WLEX LOW HEAD C 36" WL
PROP 36" BYPASS LINE
(RE: DT-12)
M
AT
CH
L
IN
E
ST
A
8+
0+50 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00
ST
A
1+
.5 2T
O P
EX
6" W
L
TO
P
EL
EV
=3
2.
(F
IE
LD
V
ER
IF
Y)
ST
A
1+
EX
G
AS
EL
EV
=U
N
KN
(F
IE
LD
V
ER
IF
Y)
ST
A
7+
.6
EX
" W L
TO
P
EL
EV
=U N
KN
(F
IE
LD
V
ER
IF
Y)
TO
P=
.0
TO
P=
.9
TO
P=
.8
TO
P=
.5
TO
P=
.8
TO
P=
.1
TO
P=
.4
TO
P=
.8
PV
I S
TA
+5 0.
PV
I E L
.0
PV
I S
TA
+5 0.
PV
I E L
.8
4.00% -0.08%
-0.67%
EXISTING GROUND
6' M
IN
ST
A
1+
TI
E
IN
TO
E X
" W
AT
ER
L
IN
E (R
E:
D
T-
TO
P=
.0
ST
A
1+
.1
EX
" W L
TO
P
EL
EV
=3
1.
(F
IE
LD
V
ER
IF
Y)
INSTALL 700 LF 36" AWWA C200/C303 (ALT BID) CLASS 150 PIPE
ST
A
4+
.9
IN
ST
AL
L:
1-
CA
V
AS
SE
M
BL
Y
(R E:
DT
-4
1-
TY
PE
B T
RA
FF
IC
R
AT
ED
V
AU
LT
L
ID
(R
E:
D
T- 6)
TO
P=
.7
ST
A
3+
IN
ST
AL
L:
1-
" B
FV
M
AN
HO
LE
(R E:
DT
-5
TO
P=
.8
ST
A
1+
.5
EX
F
/O
TO
P
EL
EV
U N
KN
(F
IE
LD
V
ER
IF
Y)
TOP OF PIPE
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:54 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-PIPE03.dwg
CV
-P
PL
-P
P-
PI
PE
.d w g
La st
S av ed : 1
2/
/2
2:
d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
PI
PE
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
SCALE IN FEET
0 10'5'
VERTICAL
NORTH
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
WL-1
ST
A
1+
T O
S
TA
+0
TH
S
T
AN
D
YU
M A
AV
E
CI
VI
L
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
SCALE IN FEET
0 80'40'
HORIZONTAL
NOTES:
1. CONTRACTOR SHALL VERIFY
LOCATION AND DEPTH OF ALL
UTILITIES PRIOR TO BEGINNING
OF CONSTRUCTION.
2. CONTRACTOR WILL BE
REQUIRED TO PREPARE AND
SUBMIT FOR APPROVAL A
TRAFFIC CONTROL PLAN SEALED
BY A LICENSED PROFESSIONAL
ENGINEER REGISTERED IN THE
STATE OF TEXAS, PRIOR TO
CONSTRUCTION STARTING.
CONTRACTOR SHALL FOLLOW
THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES (TMUTCD)
AND ALL CITY RULES AND
REGULATIONS.
3. CONTRACTOR SHALL MAINTAIN
VEHICLE ACCESS TO
HOMEOWNERS WHOSE
DRIVEWAYS ARE CROSSED BY
THE PROPOSED PIPELINE
ALIGNMENT AT ALL TIMES.
4. CONTRACTOR SHALL MAINTAIN
A MINIMUM OF 2' VERTICAL
SEPARATION BETWEEN THE
PIPELINE AND EXISTING
UTILITIES.
5. WORK LIMITS ARE SHOWN ON
THIS SHEET
6. RETURN GRADES OF DISTURBED
AREAS TO PRECONSTRUCTION
GRADES AFTER INSTALLATION
ACTIVITIES ARE COMPLETE.
MAINTAIN ZERO NET FILL FOR
BACKFILL AND FILLS IN THE
FLOODPLAIN FROM STA 6+67
TO STA 27+00. DISPOSE OF
EXCESS MATERIAL FROM
EXCAVATION OFF SITE.
7. AIR VENT PIPES TO BE PLACED
BEHIND THE BACK OF CURB. AIR
VENT PIPES SHALL BE
POSITIONED TO MAINTAIN
REQUIRED ADA CLEARANCES,
REMAIN OUTSIDE PEDESTRIAN
ACCESS ROUTES, AND AVOID
CONFLICTS WITH SIDEWALKS,
CURB RAMPS, UTILITIES, AND
OTHER SURFACE FEATURES.
COORDINATE FINAL LOCATIONS
IN THE FIELD AS NECESSARY.
EXISTING UNDERGROUND AND
OVERHEAD UTILITIES IN THE AREA.
48 HOURS PRIOR TO
CONSTRUCTION CONTACT
1-800-DIG-TESS
CAUTION!!! 01
/1
4/
SSMH RIM = 3282.22
UNABLE TO INERT,
NOT FOUND FIELD
SSMH RIM = 3282.55
FL 6" PVC E = 3276.39
FL 6" PVC SW = 3276.37
10" DI
8"
8" P
VC
10" AC
6" PVC
ENTERS LIFT
STATION
" P
VC
F
M
16" PVC FM
18" ENTERS LIFT
STATION
8"
18"
ENTERS MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD
ENTERS MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD
UPLAND CROSSING ADDITION
LOTS 78-130, TRACTS B & C
BETENBOUGH HOMES LLC
6305 82ND ST
LUBBOCK TX 79424-3681
(CCFN: 2020042791)
0.286 ACRE
LUPE SERVANTEZ ESTATE
7338 26TH ST
LUBBOCK, TX 79407
(NO DOCUMENT FOUND)
MAILBOX
MAILBOX
MAILBOX
MAILBOX
MAILBOX MAILBOX
MAILBOXVegetation
Ground Obscured
32' RIGHT-OF-WAY EASEMENT (DEDICATED BY PLAT)
30' RIGHT-OF-WAY EASEMENT
(VOL: 473, PG: 315)
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
0.175 ACRE
7328 26TH ST
LUBBOCK, TX 79407
LANDWISE PROPERTIES LLC
9005 DAWSON AVE
WOLFFORTH TX 79382
(CCFN: 2022002345)
0.167 ACRE
R GAITHER SYMANTHA
10127 OLGA LN
HOUSTON TX
77041-6115
(NO DOCUMENT
FOUND)
0.167 ACRE
7324 26TH ST
LUBBOCK, TX 79407
BRIAN ROSSER
5401 71ST
LUBBOCK TX 79424
(VOL: 9463, PG: 272)
JOSE & ANGEL
7322 26TH ST
LUBBOCK, TX 79407
(VOL: 4225, PG: 247)
CONNALLY TRACTS
UNRECORDED SUBDIVISION
0.286 ACRE
7346 26TH ST
LUBBOCK, TX 79407
JOSEFA MENDOLLA
5508 69TH ST
LUBBOCK TX 79424-1414
(NO DOCUMENT FOUND)
0.286 ACRE
ROBERT & TERESA GARCIA
7344 26TH ST
LUBBOCK, TX 79407
(VOL: 2743, PG: 018)
0.286 ACRE
LUPE SERVANTEZ ESTATE
7338 26TH ST
LUBBOCK, TX 79407
(NO DOCUMENT FOUND)
0.248 ACRE
ALFREDO CARRIZALES ESTATE
7336 26TH ST
LUBBOCK, TX 79407
(NO DOCUMENT FOUND)
0.286 ACRE
ROBERT GARCIA
7342 26TH ST
LUBBOCK, TX 79407
(VOL: 9720, PG: 180)
0.771 ACRE
LOUISE CONNALLY
7330 26TH ST
LUBBOCK, TX 79407
(NO DOCUMENT FOUND)
CP-18
STA 10+23.11
INSTALL:
1-STANDARD TEST STATION
(RE:1/CP-6)
N=7273576.84 E=909729.50
9'
7'
WORK LIMITS WORK LIMITS
STA 9+00.00
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273581.09 E=909852.84
U
RB
AN
A
PL
AC
E
U
RB
AN
A
PL
AC
E
26TH STREET
(ASPHALT PAVEMENT)
8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00
1323 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
EX 8" PVC WL EX 8" PVC SS
EX 16" PVC FM
EX 10" PVC WL EX 10" PVC WL
EX 16" PVC FM
303 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
158 SY OF CONCRETE
PAVEMENT REPAIR
(RE:DT-9)
PROPOSED 36" WL
M
ATCH LIN
E STA 8+00
M
ATCH LIN
E STA 16+00
8+008+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+0016+00
TO
P=
.8
TO
P=
.8
TO
P=
.3
TO
P=
.2
TO
P=
.0
TO
P=
.9
TO
P=
.7
TO
P=
.6
TO
P=
.4
TO
P=
.3
TO
P=
.3
PV
I S
TA
+5 6.
PV
I E L
.4
-0.67% -0.15%
EXISTING GROUND
ST
A
8+
.0
EX
" W L
TO
P
EL
EV
=3
6.
(F
IE
LD
V
ER
IF
Y)
6' M
IN
INSTALL 800 LF 36" AWWA C200/C303 (ALT BID) CLASS 150 PIPE
TOP OF PIPE
ST
A
8+
.3
EX
8" S
S
FL
=3
6.
(F
IE
LD
V
ER
IF
Y)
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/30/2025 8:55 AM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-PIPE03.dwg
CV
-P
PL
-P
P-
PI
PE
.d w g
La st
S av ed : 1
2/
/2
8:
A d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
PI
PE
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
SCALE IN FEET
0 10'5'
VERTICAL
NORTH
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
SCALE IN FEET
0 80'40'
HORIZONTAL
EXISTING UNDERGROUND AND
OVERHEAD UTILITIES IN THE AREA.
48 HOURS PRIOR TO
CONSTRUCTION CONTACT
1-800-DIG-TESS
CAUTION!!!
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
WL-2
ST
A
8+
T O
S
TA
6+
TH
S
T
AN
D
YU
M A
AV
E
CI
VI
L
NOTES:
1. CONTRACTOR SHALL VERIFY
LOCATION AND DEPTH OF ALL
UTILITIES PRIOR TO BEGINNING
OF CONSTRUCTION.
2. CONTRACTOR WILL BE
REQUIRED TO PREPARE AND
SUBMIT FOR APPROVAL A
TRAFFIC CONTROL PLAN SEALED
BY A LICENSED PROFESSIONAL
ENGINEER REGISTERED IN THE
STATE OF TEXAS, PRIOR TO
CONSTRUCTION STARTING.
CONTRACTOR SHALL FOLLOW
THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES (TMUTCD)
AND ALL CITY RULES AND
REGULATIONS.
3. CONTRACTOR SHALL MAINTAIN
VEHICLE ACCESS TO
HOMEOWNERS WHOSE
DRIVEWAYS ARE CROSSED BY
THE PROPOSED PIPELINE
ALIGNMENT AT ALL TIMES.
4. CONTRACTOR SHALL MAINTAIN
A MINIMUM OF 2' VERTICAL
SEPARATION BETWEEN THE
PIPELINE AND EXISTING
UTILITIES.
5. WORK LIMITS ARE SHOWN ON
THIS SHEET
6. RETURN GRADES OF DISTURBED
AREAS TO PRECONSTRUCTION
GRADES AFTER INSTALLATION
ACTIVITIES ARE COMPLETE.
MAINTAIN ZERO NET FILL FOR
BACKFILL AND FILLS IN THE
FLOODPLAIN FROM STA 6+67
TO STA 27+00. DISPOSE OF
EXCESS MATERIAL FROM
EXCAVATION OFF SITE.
/1
4/
6" DI
UNABLE TO
TONE, NOT
FOUND IN
RECORDS
10" PVC
10" PVC10" PVC
MAILBOX
5.00 ACRE
AUGUSTINE LARA
PO BOX 16081
LUBBOCK TX 79490-6081
(VOL: 4119, PG: 169)
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
0.286 ACRE
7348 26TH ST
LUBBOCK, TX 79407
JUAN GONZALES
1819 E 1ST ST
LUBBOCK TX 79401
(CCFN: 2009031152)
0.286 ACRE
7346 26TH ST
LUBBOCK, TX 79407
JOSEFA MENDOLLA
5508 69TH ST
LUBBOCK TX 79424-1414
(NO DOCUMENT FOUND)
VE
N
IT
A
AV
EN
U E
5.00 ACRE
AUGUSTINE LARA
PO BOX 16081
LUBBOCK TX 79490-6081
(VOL: 4119, PG: 169)
UPLAND CROSSING ADDITION
LOTS 78-130, TRACTS B & C
BETENBOUGH HOMES LLC
6305 82ND ST
LUBBOCK TX 79424-3681
(CCFN: 2020042791)
VEN
ITA AVEN
UE
26TH STREET
(ASPHALT PAVEMENT)
AL
LE
YW
AY
PI STA 17+86.89
r 45°04'38"
INSTALL:
1-36"x 45° BEND N=7273634.88 E=908976.98
PI STA 17+53.68
r 44°55'55"
INSTALL:
1-36" x 45° BEND N=7273610.63 E=908999.66
STA 17+58.19
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273613.92 E=908996.58
STA 17+86.89
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273634.88 E=908976.98
STA 21+01.40
INSTALL:
1-STANDARD TEST STATION
(RE:1/CP-6)
N=7273652.23 E=908662.86
STA 17+98.45
INSTALL:
1- BOV ASSEMBLY
(RE: DT-4)
N=7273635.26 E=908965.42
WORK LIMITSWORK LIMITS
WORK LIMITS
16+00 17+00
18+00 19+00 20+00 21+00 22+00 23+00
589 SY OF ASPHALT PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
PROPOSED 36" WL
EX 10" PVC WL
EX 10" PVC WL
89 SY OF CONCRETE
PAVEMENT REPAIR
(RE:DT-9)
1363 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
331 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
66 SY OF CONCRETE
PAVEMENT REPAIR
(RE:DT-9)
M
AT
CH
L
IN
E
ST
A
+0
M
AT
CH
L
IN
E
ST
A
+0
16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00
TO
P=
.3
TO
P=
.1
TO
P=
.0
TO
P=
.5
TO
P=
.1
TO
P=
.7
TO
P=
.2
TO
P=
.8
PV
I S
TA
7+
.4
PV
I E
L
.0
0.57% 0.57%
-0.15%
EXISTING GROUND
ST
A
+6
3.
EX
0" W
L
TO
P
EL
EV
=U
N
KN
(F
IE
LD
V
ER
IF
Y)
6' M
IN
INSTALL 700 LF 36" AWWA C200/C303 (ALT BID) CLASS 150 PIPE
ST
A
+9
8.
IN
ST
AL
L:
1-
BO
V
AS
SE
M
BL
Y(
RE
:D
T- 4)
TO
P=
.0
6' M
IN
TOP OF PIPE
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:55 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-PIPE03.dwg
CV
-P
PL
-P
P-
PI
PE
.d w g
La st
S av ed : 1
2/
/2
2:
d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
PI
PE
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
SCALE IN FEET
0 10'5'
VERTICAL
NORTH
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
SCALE IN FEET
0 80'40'
HORIZONTAL
EXISTING UNDERGROUND AND
OVERHEAD UTILITIES IN THE AREA.
48 HOURS PRIOR TO
CONSTRUCTION CONTACT
1-800-DIG-TESS
CAUTION!!!
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
WL-3
ST
A
+0
TO
S
TA
3+
TH
S
T
AN
D
YU
M A
AV
E
CI
VI
L
NOTES:
1. CONTRACTOR SHALL VERIFY
LOCATION AND DEPTH OF ALL
UTILITIES PRIOR TO BEGINNING
OF CONSTRUCTION.
2. CONTRACTOR WILL BE
REQUIRED TO PREPARE AND
SUBMIT FOR APPROVAL A
TRAFFIC CONTROL PLAN SEALED
BY A LICENSED PROFESSIONAL
ENGINEER REGISTERED IN THE
STATE OF TEXAS, PRIOR TO
CONSTRUCTION STARTING.
CONTRACTOR SHALL FOLLOW
THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES (TMUTCD)
AND ALL CITY RULES AND
REGULATIONS.
3. CONTRACTOR SHALL MAINTAIN
VEHICLE ACCESS TO
HOMEOWNERS WHOSE
DRIVEWAYS ARE CROSSED BY
THE PROPOSED PIPELINE
ALIGNMENT AT ALL TIMES.
4. CONTRACTOR SHALL MAINTAIN
A MINIMUM OF 2' VERTICAL
SEPARATION BETWEEN THE
PIPELINE AND EXISTING
UTILITIES.
5. WORK LIMITS ARE SHOWN ON
THIS SHEET
6. RETURN GRADES OF DISTURBED
AREAS TO PRECONSTRUCTION
GRADES AFTER INSTALLATION
ACTIVITIES ARE COMPLETE.
MAINTAIN ZERO NET FILL FOR
BACKFILL AND FILLS IN THE
FLOODPLAIN FROM STA 6+67
TO STA 27+00. DISPOSE OF
EXCESS MATERIAL FROM
EXCAVATION OFF SITE.
/1
4/
6"
VC
8" P
VC
10" PVC 10" PVC
Vegetation Ground Obscured
30' RIGHT-OF-WAY EASEMENT
(VOL: 473, PG: 315)
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
32' RIGHT-OF-WAY EASEMENT
(CCFN: 2022031764)32' RIGHT-OF-WAY EASEMENT (DEDICATED BY PLAT)
2.00 ACRE
WESLEY GARNER
7509 W 26TH ST
LUBBOCK TX 79407
(CCFN: 2009530760)
6.00 ACRE
ELVIRA LARA
7918 34TH ST
LUBBOCK TX 79407-4802
(CCFN: 2013003250)
P.O.B.
N= 7,271,923.73' E= 907,471.48'
6.00 ACRE
ELVIRA LARA
7918 34TH ST
LUBBOCK TX 79407-4802
(CCFN: 2013003250)
26TH STREET
(ASPHALT PAVEMENT)
VI
RG
IN
IA
A
VE
N U
E
AL
LE
YW
AY
VI
O
LA
A
VE
N
U E
CP-17
STA 26+01.40
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273660.99 E=908162.88
STA 31+21.40
INSTALL:
1-CATHODIC PROTECTION
RECTIFIER
(RE:1/CP-5)
N=7273674.29 E=907643.04
4'
8'
WORK LIMITS
23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00
PROPOSED 36" WL
1398 SY OF ASPHALT PAVEMENT
REPAIR (RE:1/DT-1,3/DT-17)
M
AT
CH
L
IN
E
ST
A
+0
M
AT
CH
L
IN
E
ST
A
+0
23+0023+00 24+00 25+00 26+00 27+00 28+00 29+00 30+0030+00
0.57%
1.62%
TO
P=
.8
TO
P=
.4
TO
P=
.0
TO
P=
.5
TO
P=
.1
TO
P=
.7
TO
P=
.2
TO
P=
.9
TO
P=
.9
EXISTING GROUND
PV
I S
TA
9+
.2
PV
I E
LE
V=
.8
6' M
IN
INSTALL 700 LF 36" AWWA C200/C303 (ALT BID) CLASS 150 PIPE
TOP OF PIPE
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:55 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-PIPE03.dwg
CV
-P
PL
-P
P-
PI
PE
.d w g
La st
S av ed : 1
2/
/2
2:
d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
PI
PE
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
SCALE IN FEET
0 10'5'
VERTICAL
NORTH
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
SCALE IN FEET
0 80'40'
HORIZONTAL
NOTES:
1. CONTRACTOR SHALL VERIFY
LOCATION AND DEPTH OF ALL
UTILITIES PRIOR TO BEGINNING
OF CONSTRUCTION.
2. CONTRACTOR WILL BE
REQUIRED TO PREPARE AND
SUBMIT FOR APPROVAL A
TRAFFIC CONTROL PLAN SEALED
BY A LICENSED PROFESSIONAL
ENGINEER REGISTERED IN THE
STATE OF TEXAS, PRIOR TO
CONSTRUCTION STARTING.
CONTRACTOR SHALL FOLLOW
THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES (TMUTCD)
AND ALL CITY RULES AND
REGULATIONS.
3. CONTRACTOR SHALL MAINTAIN
VEHICLE ACCESS TO
HOMEOWNERS WHOSE
DRIVEWAYS ARE CROSSED BY
THE PROPOSED PIPELINE
ALIGNMENT AT ALL TIMES.
4. CONTRACTOR SHALL MAINTAIN
A MINIMUM OF 2' VERTICAL
SEPARATION BETWEEN THE
PIPELINE AND EXISTING
UTILITIES.
5. WORK LIMITS ARE SHOWN ON
THIS SHEET
6. RETURN GRADES OF DISTURBED
AREAS TO PRECONSTRUCTION
GRADES AFTER INSTALLATION
ACTIVITIES ARE COMPLETE.
MAINTAIN ZERO NET FILL FOR
BACKFILL AND FILLS IN THE
FLOODPLAIN FROM STA 6+67
TO STA 27+00. DISPOSE OF
EXCESS MATERIAL FROM
EXCAVATION OFF SITE.
EXISTING UNDERGROUND AND
OVERHEAD UTILITIES IN THE AREA.
48 HOURS PRIOR TO
CONSTRUCTION CONTACT
1-800-DIG-TESS
CAUTION!!!
PI
PE
LI
N
E W
ES
T
LU
BB
O
CK
W
AT
ER
S
YS
TE
M E
XP
AN
SI
O
N
100% SUBMITTAL
LU
B2
/2
CI
TY
O F
LU
BB
O
CK
, T
EX
M
AM
WL-4
ST
A
+0
TO
S
TA
0+
TH
S
T
AN
D
YU
M A
AV
E
CI
VI
L
/1
4/
GOES
BEHIND THE
FENCE
6"
ENTERS
SHED
6" P
VC8"
P
VC
10" PVC
8" P
VC
6" P
VC
ENTERS MANHOLE, PER
RECORDS. UNABLE TO
LOCATE IN THE FIELD
GARNER ADDITION
LOT 1
(VOL: 2678, PG: 45)
0.80 ACRE
WESLEY GARNER
7509 W 26TH ST
LUBBOCK TX 79407
MAILBOX
W
AU
SA
U
A
VE
N U
E
Vegetation Ground Obscured
32' RIGHT-OF-WAY EASEMENT (DEDICATED BY PLAT)
14.13 ACRE
COYOTE LAND LTD
6309 INDIANA AVE STE B
LUBBOCK TX 79413-5739
(CCFN: 2010024988)
30' RIGHT-OF-WAY EASEMENT
(VOL: 473, PG: 315)
' R
IG
HT
-O F-
W
AY
E
AS
EM
EN
T (V
O L:
, P G:
30' STREET
(KILLIAN TRACTS PLAT)
2.00 ACRE
WESLEY GARNER
7509 W 26TH ST
LUBBOCK TX 79407
(CCFN: 2009530760)
26TH STREET
(ASPHALT PAVEMENT)
26TH STREET
(ASPHALT PAVEMENT)
W
IN
FI
EL
D
AV
EN
U
E
CP-16
W
AU
SA
U
A
VE
N U
E
STA 31+21.40
INSTALL:
1-CATHODIC PROTECTION
RECTIFIER
(RE:1/CP-5)
N=7273674.29 E=907643.04
STA 34+01.40
INSTALL:
1-FIBER PULL BOX
1-FIBER UTILITY MARKER
N=7273686.63 E=907363.29
7'9'
WORK LIMITS WORK LIMITS
'26
TH
S
TR
EE
T (A
SP
HA
LT
P
AV
EM
EN
T)
30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00
PROPOSED 36" WL1385 SY OF ASPHALT
PAVEMENT REPAIR
(RE:1/DT-1,3/DT-17)
EX 8" PVC WL EX 6" PVC WL
EX 10" PVC WL EX 8" PVC WL 32
SY
O F
AS
PH
AL
T
PA
VE
M
EN
T
RE
PA
IR
M
AT
CH
L
IN
E
ST
A
+0
M
AT
CH
L
IN
E
ST
A
+5
30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 37+50
TO
P=
.9
TO
P=
.5
TO
P=
.1
TO
P=
.7
TO
P=
.4
TO
P=
.0
TO
P=
.6
TO
P=
.2
TO
P=
.0
1.62%
6' M
IN
INSTALL 750 LF 36" AWWA C200/C303 (ALT BID) CLASS 150 PIPE
EXISTING GROUND
TOP OF PIPE
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
SE
AL
ED
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 12/29/2025 2:55 PM Plot By: 08524 Filename: N:\WTU\Drawings\Pipeline\CV-PPL-PP-PIPE03.dwg
CV
-P
PL
-P
P-
PI
PE
.d w g
La st
S av ed : 1
2/
/2
2:
d By
: 0
Fi le na m e:
N
W
TU
\D ra w in gs \P ip el in e\
CV
-P
PL
-P
P-
PI
PE
.d w g
AC
AD
R el : 2
5.
1s
(L M
S Te ch
Fr ee se a nd N ic ho ls, In c.
Te xa s R eg ist er ed
E ng in ee rin g
Fi rm
F -2
S . L oo p
9, S ui te
Lu bb oc k, T ex as
Ph on e
6)
-2
W eb w w w
.fr ee se .c om
SCALE IN FEET
0 10'5'
VERTICAL
NORTH
IS
SU
ED
F
O R
CO
N
ST
RU
CT
IO
N O
N 4/
/2
O N
TE
XA
S
N O
TH
E
SE
AL
T
HA
T O
RI
GI
N
AL
LY
A
PP
EA
RE
D
O N
T
HI
S
DO
CU
M
EN
T
W
AS
A U
TH
O
RI
ZE
D
BY
AL
TE
RA
TI
O N
O F
A
SE
AL
ED
D O
CU
M
EN
T
W
IT
HO
U
T
PR
O
PE
R N
O
TI
FI
CA
TI
O
N O
F
TH
E
RE
SP
O
N
SI
BL
E
EN
GI
N
EE
R
IS
A N
O
FF
EN
SE
U N
DE
R
TH
E
TE
XA
S
EN
GI
N
EE
RI
N G
PR
AC
TI
CE
A
CT
M
IC
HA
EL
A
LL
EN
M
CB
EE
P .E
4/
/2
SCALE IN FEET
0 80'40'
HORIZONTAL
NOTES:
1. CONTRACTOR SHALL VERIFY
LOCATION AND DEPTH OF ALL
UTILITIES PRIOR TO BEGINNING
OF CONSTRUCTION.
2. CONTRACTOR WILL BE
REQUIRED TO PREPARE AND
SUBMIT FOR APPROVAL A
TRAFFIC CONTROL PLAN SEALED
BY A LICENSED PROFESSIONAL
ENGINEER REGISTERED IN THE
STATE OF TEXAS, PRIOR TO
CONSTRUCTION STARTING.
CONTRACTOR SHALL FOLLOW
THE LATEST EDITION OF TEXAS
MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES (TMUTCD)
AND ALL CITY RULES AND
R…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .