This file contains technical specifications, installation instructions, and administrative templates for the AMI Small Meter Replacements project conducted by the Salt Lake City Department of Public Utilities (SLCDPU). The project involves the replacement of drinking water meters at various locations within the SLCDPU water service area, with an engineer's estimate of $775,870.00. The primary equipment specified is the Sensus iPERL+ smart water meter, an electromagnetic flow measurement system available in 5/8", 5/8" x 3/4", 3/4", and 1" sizes for both potable and reclaim water service. The iPERL+ features a 20-year accuracy warranty, 20-year battery life guarantee, solid-state electromagnetic technology with no moving parts, and smart water alarms for leak detection, reverse flow, empty pipe detection, magnetic tamper identification, and low battery alerts. The system integrates with Sensus AMI/AMR networks and FlexNet communication systems for remote management, monitoring, and diagnosis, with capability to log up to 120 days of hourly consumption data.
Installation requirements specify that meters must be oriented with flow arrows aligned to plumbing direction, installed with proper gaskets, and tested to ensure positive flow registration without empty pipe alarms or negative flow readings. The project includes pre-notification and post-notification templates in English and Spanish to inform customers of meter replacement activities, landscaping disturbance expectations, water discoloration possibilities, and contact information for the SLCDPU Customer Service office at (801) 483-6900. A data transfer format template is provided detailing the database structure for tracking meter information, including service numbers, addresses, geographic coordinates, meter specifications, installation dates, and various meter characteristics. The project area encompasses Salt Lake City and surrounding municipalities including Taylorsville, Midvale, Murray, Holladay, and other communities within the SLCDPU service territory, as depicted in the project map included in the appendices.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Final Bid Set Specifications 03APR2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX A
Owner Furnished
Equipment Submittal Package
DATA SHEET
WDS-10066-03
iPERL+ Smart Water Meter Electromagnetic Flow Measurement System Sensus iPERL+® smart water meters are designed to capture both lost water and lost revenue. The innovative magnetic technology delivers unmatched low flow registration and minimal pressure loss. With no moving parts, iPERL+ maintains its accuracy over a 20 year lifetime and is equipped with smart water alarms – delivering the intelligence you need to quickly resolve issues in the field.
Industry Leading Performance
The patented measurement technology of the iPERL+ water meter provides continuous and enhanced accuracy ranges at both low and high flows and perpetual accuracy over the life of the product. The iPERL+ meter has a 20-year accuracy warranty and a 20-year battery life guarantee. Over this 20-year lifespan, your iPERL+ will measure just as accurately as the day it was installed.
Construction
The iPERL+ has a flow tube that is comprised entirely of composite polymer and thermal polymer shell with an electronic register.
Electronic Register
The 9-digit hermetically-sealed electronic register with LCD display was designed to eliminate dirt, water, and moisture contamination in pit settings. The large, easy-to-read display includes AMI/AMR digits, direction of flow, units of measure, and empty pipe detection. The AMI/AMR digits and units of measure are fully programmable. The register also provides user configurable data logging.
Solid State Electromagnetic Technology
By avoiding the use of a mechanical measuring element inside the flow tube, metering performance is linear over the entire flow range – ensuring no reduction in accuracy at any flow rate over the life of the meter. The iPERL+ meter uses our patented remanent magnetic field technology – requiring far less energy and delivering superior accuracy.
Tamperproof
The integrated construction of the iPERL+ water meter prevents removal of the register to obtain free water. The magnetic tamper and low field alarms will both indicate any attempt to tamper with the magnetic field of the iPERL+ meter. The meter communication alarm indicates a possible cut cable.
Alarms
Quick resolution of field issues is made possible with smart water alarms including leak detection, reverse flow, empty pipe, magnetic tamper and low battery. When integrated with our FlexNet® communication network, remotely gathering and transmitting data has never been more reliable or profitable.
BENEFITS
� Maximize investment with iPERL+ electromagnetic technology, which delivers a 20-year accuracy warranty, with no required maintenance, and no loss in accuracy over 20 years.
� Smart alarms detect issues such as continuous flow, high flow, reverse flow, empty pipe, and tampering.
� Improve low flow accuracy to drive additional revenue.
FEATURES
� 5/8”, 5/8” x 3/4”, 3/4” and 1” sizes available in potable and reclaim versions.
� 3/4” and 1” available in residential fire service (UL 327b).
� Starts registering flow as low as 0.03 gpm (0.007 m³/hr).
� Can be installed horizontally, vertically or diagonally.
� Compatible with current Sensus AMI/ AMR systems.
� Reduces maintenance and cost.
� Allows remote management, monitoring, and diagnosis.
� Logs up to 120 days of hourly consumption data.
iPERL+ Smart Water Meter Electromagnetic Flow Measurement System
SPECIFICATIONS
Service Measurement of potable and reclaim water, and Residential Fire Service (UL 327b). 0-100% humidity. Fully submersible. IP68+ rated.
Temperature Ranges Water operating:
Ambient air operating:
Storage air:
33 °F (0.55 °C) to 80 °F (26.7 °C) -22 °F (-30 °C) to 140 °F (60 °C) -30 °F (-34.4 °C) to 158 °F (70 °C)
Starting Flow 5/8” (DN 15 mm) size: 0.03 gpm (0.007 m³/h)
5/8” x 3/4” (DN 15x20 mm) size: 0.03 gpm (0.007 m³/h)
3/4” (DN 20 mm) size: 0.03 gpm (0.007 m³/h)
1” (DN 25 mm) size: 0.11 gpm (0.025 m³/h)
Low Flow Range (±3%)
5/8” (DN 15 mm) size: >0.05 gpm (0.011 m³/hr) to <0.18 gpm (0.041 m³/hr)
5/8” x 3/4” (DN 15 mm) size:
>0.05 gpm (0.011 m³/hr) to <0.18 gpm (0.041 m³/hr)
3/4” (DN 20 mm) size: >0.05 gpm (0.011 m³/hr) to <0.18 gpm (0.041 m³/hr)
1” (DN 25 mm) size: >0.3 gpm (0.068 m³/hr) to <0.4 gpm (0.09 m³/hr)
Normal Water Operating Flow Range (±1.5%)
5/8” (DN 15 mm) size: 0.18 to 25 gpm (0.04 to 5.7 m³/hr)
5/8” x 3/4” (DN 15x20 mm) size: 0.18 to 35 gpm (0.04 to
8.0 m³/hr)
3/4” (DN 20 mm) size: 0.18 to 35 gpm (0.04 to 8.0 m³/hr)
1” (DN 25 mm) size: 0.4 to 55 gpm (0.09 to 12.5 m³/hr)
Normal Test Flow Limits (per UL 327b Listing, at ±1.5% accuracy)
3/4” (DN 20 mm) size:
2 to 30 gpm (0.5 to 6.8 m³/hr)
1” (DN 25 mm) size:
2 to 50 gpm (0.5 to 11.4 m³/hr)
Maximum Operating Pressure
5/8’’, 5/8” x 3/4”, and 3/4’’ size: 200 psi (13.8 bar) 1’’ size: 175 psi (12.1 bar)
Maximum Operating Pressure (per UL 327b Listing, at ±1.5% accuracy)
3/4” and 1’’ size: 175 psi (12.1 bar)
Measurement Technology
Solid state electromagnetic flow
Register Hermetically sealed, 9-digit programmable electronic register
Capacity 10,000,000 gallons, 1,000,000 cubic feet or 100,000 m³ capacity
Register Resolution .01 gallons/imperial gallons, .001 cubic foot, or .0001 m³
Conformance to Standards
Meets the requirements of NSF 61, Annex G and NSF 372.
Exceeds the most current revision of AWWA Standard C-715.
Materials External housing – Thermal polymer Flowtube – Composite polymer with a composite polymer internal core
Electrode – Silver/silver chloride Register cover – Hermetically sealed glass
� High Flow Detect large and continuous volume of water. This occurs if the consumption between consecutive reads exceeds the broken pipe threshold.
� Continuous Flow Detect continual consumption of water over a period of time to indicate downstream leaks. This protects your utility, infrastructure and customers through alarm notifications that can reduce water loss and leak adjustment costs.
� Empty Pipe Detects the absence of water in the flow tube and sends an alert. Allows you to identify main breaks downstream and water shortages for quicker resolution to ensure water availability. This alarm can also indicate the water meter has been removed from service, or notify you of potential tamper.
� Low Battery Replace your meters before they stop recording consumption through alerts indicating battery capacity to the meter or valve is running low.
� Reverse Flow Keep untreated water from re-entering your distribution system and deter tampering attempts through an alarm triggered when reverse flow is detected at the meter.
� Tampering Detect magnetic interference to reduce apparent water losses and protect against unauthorized activities.
Smart Alarms iPERL+ meters have many configurable smart alarms designed to protect your utility’s investment, enhance customer service, and monitor/optimize distribution systems. These alarms include:
iPERL+ Smart Water Meter Electromagnetic Flow Measurement System
A
B
C
Sealed Electronic Register
Magnetic Flow Sensors Flowtube
Width
5 3/4 in.
(146 mm)
DIMENSIONS AND NET WEIGHTS
Meter Size A B C Spud Ends NPSM Thread Size Width Net Weight
5/8” (DN 15 mm)
7-1/2” (190 mm)
6-1/10” (155mm)
1-3/4” (44 mm)
5/8” (15 mm)
3/4” (20 mm)
4-1/2” (114 mm)
3.1 lb.
(1.4 kg)
5/8” x 3/4” (DN 15 mm x 20 mm)
7-1/2” (190 mm)
6-1/10” (155mm)
1-3/4” (44 mm)
3/4” (20 mm)
1” (25 mm)
4-1/2” (114 mm)
3.1 lb.
(1.4 kg)
3/4”Short (DN 20 mm)
7-1/2” (190 mm)
6-1/10” (155 mm)
1-3/4” (44 mm)
3/4” (20 mm)
1” (25 mm)
4-1/2” (114 mm)
3.1 lb.
(1.4 kg)
3/4” (DN 20 mm)
9” (229 mm)
6-1/10” (155 mm)
1-3/4” (44 mm)
3/4” (20 mm)
1” (25 mm)
4-1/2” (114 mm)
3.2 lb.
(1.45 kg)
1” (DN 25 mm)
10-3/4” (273 mm)
6-1/10” (155 mm)
1-3/4” (44 mm)
1” (25 mm)
1-1/4” (32 mm)
4-1/2” (114 mm)
3.3 lb.
(1.5 kg)
SENSUS | 639 Davis Drive | Morrisville, NC 27560 | 800.638.3748
©2024 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.
This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.
FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT
SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.
Xylem.com | Sensus.com iPERL+ Smart Water Meter Electromagnetic Flow Measurement System
Head Loss Curves
0 5 10 15 20 25 30
He ad
L os s ( ps i)
Flow Rate (gpm)
5/8" iPERL
5/8" iPERL Head Loss (psi) AWWA Max Allowable Head Loss
0 5 10 15 20 25 30 35 40
He ad
L os s ( ps i)
Flow Rate (gpm)
5/8" x 3/4" and 3/4" Short iPERL
5/8 x 3/4" and 3/4" Short iPERL Head Loss (psi) AWWA Max Allowable Head Loss
0 5 10 15 20 25 30 35 40 45 50 55 60
He ad
L os s ( ps i)
Flow Rate (gpm)
1" iPERL
1" iPERL Head Loss (psi) AWWA Max Allowable Head Loss
0 5 10 15 20 25 30 35 40
He ad
L os s ( ps i)
Flow Rate (gpm)
3/4" iPERL
3/4" iPERL Head Loss (psi) AWWA Max Allowable Head Loss
DATA SHEET
WDS-10024-03
SmartPoint 520M Pit Set Module
BENEFITS:
�� Easily receives input from either walk-by/ drive-by or fixed-base collection device
�� Controls both deployment and lifetime operation costs
�� Compact installation that saves time, space and money - without reducing system performance
�� Delivers a fast, efficient and reliable connection at minimal cost
�� Minimizes new infrastructure investment
�� Enables effective leak detection
The SmartPoint® 520M Pit Set Module is a radio transceiver that provides water utilities inbound and outbound access to water measurement and ancillary device diagnostics via radio signal. The SmartPoint 520M is designed for submersible, pit-set environments.
TouchCoupler Design The SmartPoint 520M Module utilizes TouchCoupler, the patented
Sensus inductive coupling communication platform, to interface with the encoded meter. With TouchCoupler, the SmartPoint 520M Module can connect to the meter using existing two wire AMR installations instead of requiring utilities to access the meter to install a new three-wire connection. This results in a fast, efficient and reliable connection at minimal cost.
Operation With its migratable, two-way communication ability, the M-Series
SmartPoint functions as a walk-by/drive-by endpoint, fixed-base endpoint, or combination of the two. This flexibility increases utility data collection capabilities and streamlines operations. The SmartPoint 520M
Module receives input from the meter register and remotely sends data to a walk-by/drive-by or fixed-base collection device. The SmartPoint
520M Module easily migrates from walk-by/drive-by to fixed base by simply installing a Base Station.
In walk-by/drive-by mode, the SmartPoint 520M Module collects data and awaits an activation signal from the Vehicle Gateway Basestation
(VGB) or Hand-Held Device (HHD). Upon signal receipt, it transmits readings, the meter identification number and any alarms.
As a fixed-base endpoint, the SmartPoint 520M Module interacts with one or more strategically placed Base Stations located in the utility service area.
Top of the hour readings and other diagnostics are instantly forwarded to the Regional Network Interface (RNI)™ at time of transmission. The
FlexNet® communication network provides unmatched reliability by using expansive tower receiver coverage of metering end points, data/message redundancy, failover backup provisions and operation on FCC primary use
(unshared) RF spectrum.
©2018 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer.
The Sensus logo is a registered trademark of Sensus.
This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.
8601 Six Forks Rd, Ste 700 Raleigh, NC 27615 1-800-638-3748 sensus.com
SmartPoint 520M Pit Set Module
Powerful Transmission, Flexible Platform The SmartPoint® 520M Pit Set Module offers several advantages that control both deployment and lifetime operation costs. Its powerful, industry-leading two watt transmitter broadcasts over large distances and minimizes collection infrastructure.
And after the SmartPoint is installed, its migratable, two-way system platform can be updated without requiring personnel to visit each meter and/or inconveniencing customers.
Additional Smartpoint 520M Module Features The SmartPoint 520M Module obtains hourly readings and can monitor continuous flow over a programmable period of time, alerting the utility to leak conditions. In addition, the SmartPoint stores up to 840 consumption intervals (35 days of hourly consumption), providing the utility with the ability to extract detailed usage profiles for consumer information and dispute resolution. The SmartPoint also incorporates a two-port design, allowing the utility to connect multiple registers and ancillary devices (such as acoustic monitoring) to a single
SmartPoint. This results in a compact installation that saves time, space and money - without reducing system performance.
Specifications Service Pit set installation interfacing the utility meter to the Sensus FlexNet communication network. Unit requires 1.75” diameter hole in pit lid; fits pit lid thicknesses up to 1.75”
Physical characteristics Width: 4.43” x Height: 5.09” x Depth: 3”
Weight 1.0 lbs/16.0 oz
Color Black
Frequency range 900 – 950 MHz, 8000 channels X 6.25 kHz steps
Modulation Proprietary Narrow Band
Memory Non-Volatile
Power Lithium Thionyl Chloride batteries
Approvals US: FCC CFR 47: Part 24D, Part 101C, Part 15 Licensed operation Canada: Industry Canada (IC) RSS-134, RSS-119
Operating temperature - 22° F to +185° F
- 30° C to + 85° C
Options Dual or single port availability; TouchCoupler only, wired only
Installation environment 100% condensing, water submersible
Compatibility TouchCoupler and Wired Version: Sensus Encoder Registers, Badger ADE water registers, Master Meter AccuLinx, and Hersey Translator (approved TR/PL Lead)
Wired Version Only: Elster Encoder (Sensus protocol), Neptune ARB VI (ProRead), Hersey Translator, Zenner PMN Nitro 01, McCrometer flowcom FC100-00M, and Kamstrup flowIQ 2100
Refer to the 510M/520M SmartPoint® Module Water Meter and Ancillaries Compatibility Quick Guide for the latest compatibility information.
Warranty 20 years – Based on six transmissions per day.
Refer to Sensus G-500 for warranty.
FEATURES
• EPDM Rubber Gasket
• Conforms to ASTM D2000
• NSF 61 Compliant
RUBBER METER GASKET FOR 5/8" TO 1-1/4" METER CONNECTIONS
C S D A D B T
(T) P
N
✓ S
I ( )
5/8" 5/8" 15/16" 1/8" GT-108
3/4" 3/4" 1-5/32" 1/8" GT-114
1" 1" 1-1/2" 1/8" GT-120
1-1/4" 1-3/16" 1-11/16" 1/8" GT-124
The Ford Meter Box Company, Inc.
P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com
Submitted By:
The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. Our standard warranty applies.
02/24/20
Meter Gasket - (GT-xxx style)
SUBMITTAL INFORMATION
AB
T
TOP VIEW SIDE VIEW
Ø12.3125"
5.25" 2"
.50"
1.5"2" Thru Hole
BOTTOM VIEW
Sensus Recess
Ø10.50"LARGE
PENTA
BOLT
CUSTOMER DRAWING
12.25 Type A Pippy
NICOR, INC.
PROPRIETARY NOTICE
This document, whether patentable or non-patentable subject matter, embodies proprietary and confidential information and is the exclusive property of NICOR, INC. It may not be reproduced, used or disclosed to others for any purpose except that for which it is loaned, and it shall be returned on demand. All rights reserved.
FINISH OR TREATMENT
(UNLESS OTHERWISE SPECIFIED)
BEFORE FINISH PROCESS:
DIMENSIONS IN INCHES
(DIMENSIONS) IN MILLIMETERS
TOLERANCES UNLESS SPECIFIED: XXX+-.0010 (.0254)
XXX+-.005 (.127)
XX +- .010 (.254)
ANGLES +- .010 1/2°
REMOVE BURRS AND BREAK CORNERS
.005 (.127) MAX. UNLESS SPECIFIED
INSIDE CORNERS .010 R. MAX.
CONCENTRICITY .005 F.I.M.
MATERIAL: MAIN LID POLYMER
FINISH PROCESS
SURFACE FINISH 125
12.25PWBLKSLCthS Type A-Pippy Salt Lake City Logo
WOMAN OWNED
MADE IN THE USA
PROPRIETARY
TOP VIEW SIDE VIEW
.50"
BOTTOM VIEW
Ø12.125"Ø12.25" Ø10.375" .75" .75"
.75"
Ø4.125" SENSUS
RECESS
Ø2.00" THRU
HOLE
DEPTH .42"
CUSTOMER DRAWING
12.25 Pippy AX
NICOR, INC.
PROPRIETARY NOTICE
This document, whether patentable or non-patentable subject matter, embodies proprietary and confidential information and is the exclusive property of NICOR, INC. It may not be reproduced, used or disclosed to others for any purpose except that for which it is loaned, and it shall be returned on demand. All rights reserved.
FINISH OR TREATMENT
(UNLESS OTHERWISE SPECIFIED)
BEFORE FINISH PROCESS:
DIMENSIONS IN INCHES
(DIMENSIONS) IN MILLIMETERS
TOLERANCES UNLESS SPECIFIED: XXX+-.0010 (.0254)
XXX+-.005 (.127)
XX +- .010 (.254)
ANGLES +- .010 1/2°
REMOVE BURRS AND BREAK CORNERS
.005 (.127) MAX. UNLESS SPECIFIED
INSIDE CORNERS .010 R. MAX.
CONCENTRICITY .005 F.I.M.
MATERIAL: MAIN LID POLYMER
FINISH PROCESS
SURFACE FINISH 125
12.25PWBLKSLCthS AX
12.25 Pippy AX with Salt Lake
Public Utilities Logo with Sensus Recess & Thru Hole
WOMAN OWNED
MADE IN THE USA
Lid Weight: 2.82 lbs
TOP VIEW SIDE VIEWBOTTOM VIEW
Ø12.25"
Ø11.75" Ø11.125"
Ø10.75"
.50" .687" .50"
.75"Ø4.125" SENSUS
RECESS
Ø2.00" THRU HOLE
DEPTH .42"
LARGE PENTA BOLT
CUSTOMER DRAWING
12.25" TYPE OX
NICOR, INC.
PROPRIETARY NOTICE
This document, whether patentable or non-patentable subject matter, embodies proprietary and confidential information and is the exclusive property of NICOR, INC. It may not be reproduced, used or disclosed to others for any purpose except that for which it is loaned, and it shall be returned on demand. All rights reserved.
FINISH OR TREATMENT
(UNLESS OTHERWISE SPECIFIED)
BEFORE FINISH PROCESS:
DIMENSIONS IN INCHES
(DIMENSIONS) IN MILLIMETERS
TOLERANCES UNLESS SPECIFIED: XXX+-.0010 (.0254)
XXX+-.005 (.127)
XX +- .010 (.254)
ANGLES +- .010 1/2°
REMOVE BURRS AND BREAK CORNERS
.005 (.127) MAX. UNLESS SPECIFIED
INSIDE CORNERS .010 R. MAX.
CONCENTRICITY .005 F.I.M.
MATERIAL: MAIN LID POLYMER
FINISH PROCESS
SURFACE FINISH 125
12.25 Type OX with Worm
Gear with Sensus Recess & Thru Hole with Salt Lake Public Utilities Logo
WOMAN OWNED
MADE IN THE USA
Lid Weight: 3.12 lbs
APPENDIX B
Owner Furnished
Equipment Equipment Installation Guides
USER GUIDE
WUG-10015-03
iPERL+
WATER MANAGEMENT SYSTEM
Revision history Revision Number
Date Description
01 20-MAY-24 Initial version
02 03-JUN-24 Update low flow range.
03 16-AUG-24 Added Normal Test Flow Limits per UL 327b
Copyright © 2024 Xylem Inc. or one of its affiliates
Sensus USA 639 Davis Drive Morrisville, NC 27560
1-800-638-3748 https://www.xylem.com/en-us/brands/sensus/
Document: iPERL+ Water Management System User Guide Document Number: WUG-10015-03
Revision history | ii
Contents 1 Introducing iPERL+
Features Alarm persistence Security Specifications
2 Installation Preparing the iPERL+ site Installing iPERL+ Connect directly to an iPERL+ meter Configure the iPERL+ meter register directly Connect to an iPERL+ meter Activate and configure the SmartPoint module Deactivate an iPERL+ meter Replace an existing iPERL+
3 iPERL+ operations View iPERL+ meter details View iPERL+ details (Device Manager) Connect directly to an iPERL+ meter
View iPERL+ meter register details View sensor readings
4 iPERL+ alarms iPERL+ alerts
Contents | 3
1 Introducing iPERL+ iPERL® is an innovative residential water management system with unparalleled low flow accuracy, high flow durability, and minimal wear and maintenance needs.
Sensus iPERL+ smart water meters are designed to capture both lost water and lost revenue. The innovative magnetic technology delivers unmatched low flow registration and minimal pressure loss. With no moving parts, iPERL+ maintains its accuracy over a 20-year lifetime and is equipped with smart water alarms to deliver the intelligence you need to quickly resolve issues in the field.
Industry Leading Performance The patented measurement technology of the iPERL+ water meter provides continuous and enhanced accuracy ranges at both low and high flows and perpetual accuracy over the life of the product. The iPERL+ meter has a 20-year accuracy warranty and a 20-year battery life guarantee. Over this 20-year lifespan, your iPERL+ will measure just as accurately as the day it was installed.
Solid State Electromagnetic Technology By avoiding the use of a mechanical measuring element inside the flow tube, metering performance is linear over the entire flow range and ensures no reduction in accuracy at any flow rate over the life of the meter. The iPERL meter uses our patented remanent magnetic field technology and requires far less energy to deliver superior accuracy.
Construction The iPERL+ meter body is available in two versions. The first version has a flow tube that is comprised entirely of composite polymer. The second version is comprised of lead-free bronze alloy with a composite polymer core. Both versions use the same thermal polymer shell with the same electronic register inside.
Electronic Register The 9-digit hermetically-sealed electronic register with LCD display was designed to eliminate dirt, water, and moisture contamination in pit settings. The large, easy-to-read display includes AMI/AMR digits, direction of flow, units of measure, and empty pipe detection. The AMI/AMR digits and units of measure are fully programmable. The register also provides user configurable data logging.
1 Introducing iPERL+ | 4
Tamperproof The integrated construction of the iPERL+ water meter prevents removal of the register to obtain free water. The magnetic tamper and low field alarms will both indicate any attempt to tamper with the magnetic field of the iPERL+ meter. The meter communication alarm indicates a possible cut cable.
Features iPERL+ contains the following features and functionality.
Security method The security system ensures that only authorized people are allowed to modify system settings.
Data logging Data logging is defined as volume used and maximum flow rate per unit of time. Unit of time is programmable with a default of one hour intervals. Usage data can be extracted from the system using field software and hardware.
Resettable reading The system reading may be reset through the bi-directional TouchRead® connection.
Reading recovery The system reading is stored on an hourly basis for recovery purposes.
Reboot If the system reboots for any reason, iPERL+ saves all parameters to their latest settings.
Reprogram iPERL+ logs up to five programming sessions.
Dead Battery If the system loses power for any reason, the system may be powered through the TouchCoupler to retrieve the last reading.
Memory and self monitoring alarms iPERL+ self-monitoring alarms detect and report any memory failures.
Continuous Flow Detect continual consumption of water over a period of time to indicate downstream leaks. This protects your utility, infrastructure and customers through alarm notifications that can reduce water loss and leak adjustment costs.
Empty Pipe Detects the absence of water in the flow tube and sends an alert. Allows you to identify main breaks downstream and water shortages for quicker resolution to
1 Introducing iPERL+ | 5 ensure water availability. This alarm can also indicate the water meter has been removed from service, or notify you of potential tamper.
High Flow Detect broken pipes and reduce property damage through an alert triggered by the detection of excessive flow rates.
Low Battery Replace your meters before they stop recording consumption through alerts indicating battery capacity to the meter or valve is running low.
Reverse Flow Keep untreated water from re-entering your distribution system and deter tampering attempts through an alarm triggered when reverse flow is detected at the meter.
Tampering Detect magnetic interference to reduce apparent water losses and protect against unauthorized activities.
Alarm persistence Alarm persistence is the number of additional days an alarm notification will continue being reported after the condition is no longer active.
This is most important if you have an AMR system. If you only get data from your meters periodically, such as on a 30, 60, or 90 day reading cycle, then you may miss some alarms that happen between your reading days. If your persistence period is set for 35 days, then the meter will inform you about the alarm condition for another 35 days after the alarm goes away. This enables you to get the most data out of your meter so you can catch all of the alarms.
The persistence period sets how long the alarm will continue to display after the alarm is no longer active. The recommended setting for your persistence period is for 5 days past your reading schedule. For example, if you read on a 60-day cycle, a good persistence period is 65 days. That will make sure that you see all alarms that have happened since you last read a route.
For AMI systems, the persistence period acts as extra backup to make sure you always get your alarm data. The recommended AMI setting for the persistence period is 8 days.
Security The security system ensures that only qualified personnel may modify SmartPoint module settings.
You may use field software and hardware to communicate with SmartPoint module if the Fixed Base system cannot communicate with the base station. In this case, you must go into the field to troubleshoot an encrypted SmartPoint module.
1 Introducing iPERL+ | 6
Specifications iPERL+ is precisely engineered to meet the following physical specifications.
iPERL side views
Dimensions and net weights Size A (lay length) B (height) C Spud
Ends
NPSM
Thread Size
Width Polymer Net Weight
Metal Net Weight
5/8" (DN
15 mm)
7-1/2" (190 mm)
6-1/10" (155 mm)
1-3/4" (44 mm)
5/8" (15 mm)
3/4" (19 mm)
4-1/2" (114 mm)
3.1 lb (1.4 kg)
4.9 lb (2.2 kg)
5/8" x
3/4" (DN
15mm x 20mm)
7-1/2" (190 mm)
6-1/10" (155 mm)
1-3/4" (44 mm)
3/4" (20 mm)
1" (25 mm)
4-1/2" (114 mm)
3.1 lb (1.4 kg)
4.9 lb (2.2 kg)
3/4"Short
(DN 20
mm)
7-1/2" (190 mm)
6-1/10" (155 mm)
1-3/4" (44 mm)
3/4" (20 mm)
1" (25 mm)
4-1/2" (114 mm)
3.1 lb (1.4 kg)
5.1 lb (2.3 kg)
3/4" (DN
20 mm)
9" (229 mm)
6-1/10" (155 mm)
1-3/4" (44 mm)
3/4" (20 mm)
1" (25 mm)
4-1/2" (114 mm)
3.2 lb (1.5 kg)
5.2 lb (2.4 kg)
1" (DN 25
mm)
10" (273 mm)
6-1/10" (155 mm)
1-3/4" (44 mm)
1" (25 mm)
1-1/4" (32 mm)
4-1/2" (114 mm)
3.3 lb (1.6 kg)
5.7 lb (2.6 kg)
1 Introducing iPERL+ | 7
Operational specifications Service Measurement of potable and reclaim water. 0-100% humidity. Fully submersible. IP68 rated.
Temperature Water operating temperature range of 33 °F (0.55 °C) to 80 °F (26.7 °C) .
Ambient air operating temperature -22 °F (-30 °C) to -140 °F (60 °C). Storage air temperature -30 °F (-34.4 °C) to 158 °F (70 °C).
Starting Flow 5/8” (DN 15 mm) size: 0.03 gpm (0.007 m3/h)
5/8" x 3/4" (DN 20 mm) size: 0.03 gpm (0.007 m3/h)
3/4”S (DN 20 mm) size: 0.03 gpm (0.007 m3/h)
3/4" (DN 20 mm) size: 0.03 gpm (0.007 m3/h)
1” (DN 25 mm) size: 0.11 gpm (0.025 m3/h)
Low Flow Range (+-3%) 5/8” (DN 15 mm) size: Between 0.05 gpm (0.011 m3/hr) and 0.18 gpm (0.041 m3/hr)
5/8" x 3/4” (DN 20 mm) size: Between 0.05 gpm (0.011 m3/hr) and 0.18 gpm (0.041 m3/hr)
3/4”S (DN 20 mm) size: Between 0.05 gpm (0.011 m3/hr) and 0.18 gpm (0.041 m3/hr)
3/4” (DN 20 mm) size: Between 0.05 gpm (0.011 m3/hr) and 0.18 gpm (0.041 m3/hr)
1” (DN 25 mm) size: Between 0.3 gpm (0.068 m3/hr) and 0.4 gpm (0.09 m3/hr)
Normal Water Operating Flow Range (+-1.5%)
5/8” (DN 15 mm) size: 0.18 to 25 gpm (0.04 to 5.7 m3/hr)
5/8" x 3/4” (DN 20 mm) size: 0.18 to 35 gpm (0.04 to 8.0 m3/hr)
3/4”S (DN 20 mm) size: 0.18 to 35 gpm (0.04 to 8.0 m3/hr)
3/4” (DN 20 mm) size: 0.18 to 35 gpm (0.04 to 8.0 m3/hr)
1” (DN 25 mm) size: 0.4 to 55 gpm (0.09 to 12.5 m3/hr)
Normal Test Flow Limits (per UL 327b Listing, at ±1.5% accuracy)
3/4” (DN 20 mm) size: 2 to 30 gpm (0.5 to 6.8 m³/hr)
1” (DN 25 mm) size: 2 to 50 gpm (0.5 to 11.4 m³/hr)
Maximum Operating Pressure
5/8", 5/8" x 3/4", 3/4"S and 3/4" size: 200 psi (13.8 bar) 1" size: 175 psi (12.1 bar)
Maximum Operating Pressure (per UL 327b Listing, at ±1.5% accuracy)
3/4” and 1’’ size: 175 psi (12.1 bar)
Measurement Technology Solid state electromagnetic flow
Register Hermetically sealed, 9-digit programmable electronic register, AMR/AMI compatible
Materials External housing – Thermal polymer
Flowtube – Composite polymer or a bronze alloy flowtube with a composite polymer internal core
Electrode – Silver/silver chloride
Register cover – Hermetically sealed glass
Alarm Defaults Alarm Duration - 90 days; Leak Duration - 24 hours; Datalog Interval - 1 hour;
Alarm Mask - All alarms reported; History Mask - All event types reported
1 Introducing iPERL+ | 8
Headloss curves
1 Introducing iPERL+ | 9
Physical specifications 5/8" (DN15) 5/8" x 3/4"
(DN20)
3/4"Short
(DN20)
3/4" (DN20) 1" (DN25)
AWWA
Normal Flow
GPM (m3/h) 0.11 - 25 (0.02 - 5.7)
0.11 - 35 (0.02 - 8)
0.11 - 35 (0.02 - 8)
0.11 - 35 (0.02 - 8)
0.4 - 55 (0.09
- 12.5)
AWWA
Minimum Flow
GPM (m3/h) 0.03 (0.007) 0.03 (0.007) 0.03 (0.007) 0.03 (0.007) 0.11 (0.025)
AWWA
Continuous Flow
GPM (m3/h) 25 (5.7) 35 (8) 35 (8) 35 (8) 55 (12.5)
Laying Length Inches (mm) 7-1/2 (190) 9 (229) 7-1/2 (190) 9 (229) 10-3/4 (273)
Height - Base to Lid
Inches (mm) 6-1/10 (155) 6-1/10 (155) 6-1/10 (155) 6-1/10 (155) 6-1/10 (155)
1 Introducing iPERL+ | 10
5/8" (DN15) 5/8" x 3/4"
(DN20)
3/4"Short
(DN20)
3/4" (DN20) 1" (DN25)
Height - Base to Center Line
Inches (mm) 1-3/4 (44) 1-3/4 (44) 1-3/4 (44) 1-3/4 (44) 1-3/4 (44)
Width Inches (mm) 4-1/2 (114) 4-1/2 (114) 4-1/2 (114) 4-1/2 (114) 4-1/2 (114)
Pipe Threads Inches (mm) 3/4 (19) 1 (25) 1 (25) 1 (25) 1-1/4 (32)
Polymer Net Weight
Pounds (Kilograms)
3.1 (1.4) 3.2 (1.5) 3.1 (1.4) 3.2 (1.5) 3.3 (1.6)
Metal Net Weight
Pounds (Kilograms)
4.9 (2.2) 4.9 (2.2) 5.1 (2.3) 5.2 (2.4) 5.7 (2.6)
Pressure Loss
- Maximum Flow psi at GPM (bar at m3/h)
4.0 at 15 (0.3 at 3.4)
2.0 at 15 (0.1 at 3.4)
2.0 at 15 (0.1 at 3.4)
2.0 at 15 (0.1 at 3.4)
2.0 at 25 (0.1 at 5.7)
1 Introducing iPERL+ | 11
2 Installation When installing an iPERL+ water meter, you must install, activate, and configure the water meter to achieve full functionality.
Preparing the iPERL+ site Before you install your iPERL+ meter, you need to prepare the site.
The iPERL+ meter is designed to be installed in either an outdoor pit or in an indoor basement.
1. Unpack the meter from the packaging and remove the spud thread protectors.
Inspect the meter for any parts that may have been damaged during shipping.
2. If a new install, thoroughly flush the new water service plumbing before installing the meter.
3. Turn off the water supply valves.
CAUTION: Make sure that metallic water service plumbing is properly grounded as per local electrical codes. A ground strap or similar must be used if you believe or suspect electrical current is passing through the service pipe or if you believe or suspect that the service pipe may be used as an electrical ground.
4. If an existing install, remove the current meter out of the pit or basement.
Installing iPERL+ After the site has been prepared, you can install the iPERL+ meter.
Considerations The water meter should be installed on the discharge side of a pump with the flow directional arrow pointed downstream.
If a pump is installed on the outlet side of the water meter, a minimum of ten (10) diameters of straight pipe should be immediately downstream of the water meter to obtain valid system registration.
Suitable shutoff valves should be installed adjacent to the inlet and outlet of the water meter so that the service may be shutoff if it is necessary to remove the meter.
Clean and flush the service line thoroughly on the inlet side before installing.
The water lines must be coaxially aligned within three (3) degrees (0.4 inches) to ensure a proper seal.
It is recommended that old gaskets be completely removed and discarded and new 3/32" thick rubber gaskets be used with every installation.
1. Orient the iPERL+ meter so that the direction of the flow arrow on the meter body is aligned with the direction of the plumbing system water flow.
2. Install the new meter connection gaskets in both meter couplings.
Important: Never use thin meter gaskets.
3. Align threads and hand-tighten the coupling nuts.
2 Installation | 12
Note: Ensure water service connections are aligned and the meter has stress-free line connections to avoid damaging the meter.
4. Using a wrench, tighten an extra 1/4 to 1/2 turn on each coupling unit.
Note: Do not over tighten. You may tighten after turning on the water (if leaks are present). Additionally, do not use the opposite coupling nut for support when tightening a coupling nut. This could overstress the meter body and cause it to crack.
5. After the new meter is installed, shut off the outlet shut-off valve.
6. Open the inlet shut-off valve slowly until the meter is full of water and ensure that there are no leaks.
7. Open the outlet valve slowly until air is out of the meter and service line.
8. Open a valve downstream of the meter to ensure that no foreign debris in the water obstructs the operation of the meter.
9. It will take about 60 seconds for the iPERL+ to register flow after exiting an empty pipe condition. Check the consumption on the meter to make sure it is registering in the positive direction and not displaying an empty pipe alarm or registering negative flow. If registering negative flow, check that the meter is installed in the correct direction.
10. Connect a coupler cable or a 3-wire cable and attach to a SmartPoint module (if applicable).
11. Record meter and read information as required by the utility.
Figure 2-1: iPERL+ installation top view
2 Installation | 13
Figure 2-2: iPERL+ installation side view
Cable Assembly Sensus Part Number Description
SM50546439001 TR EXTENDER 6FT, PASSIVE - Y1
SM50546439002 TR EXTENDER 25 FT, PASSIVE - Y2
SM50546439003 DRY SET CONNECTOR, ACTIVE - Y3
SM50546439004 3-WIRE, 6FT, NO TRPL, ACTIVE - Y4
SM50546439005 3-WIRE, 25FT, NO TRPL, ACTIVE - Y5
SM50546439006 3-WIRE, 5FT, ITRON, ACTIVE - Y6
SM50546439007 3-WIRE, 25FT, ITRON, ACTIVE - Y7
SM50546439008 3-WIRE, 6FT, TRPL, ACTIVE - Y8
SM50546439009 3-WIRE, 25FT, TRPL, ACTIVE - Y9
SM50546439010 3-WIRE, 5FT, NICOR, ACTIVE - YA
SM50546439011 3-WIRE, 20FT, NICOR, ACTIVE - YB
SM50546439012 3-WIRE, 50FT, NICOR, ACTIVE - YC
Connect directly to an iPERL+ meter Connect directly to the iPERL+ meter instead of through the SmartPoint module.
You will need a field device with FieldLogic Tools, a FieldLogic Communicator, and a touchcoupler cable.
1. Power on the field device.
2. Power on the FieldLogic Communicator.
3. Connect the FieldLogic Communicator to the field device.
4. Connect one end of the coupler cable to the FieldLogic Communicator.
5. Start the FieldLogic Tools application on your field device.
2 Installation | 14
Configure the iPERL+ meter register directly The iPERL+ meter register can be configured directly.
Before configuring the register, make sure that you have the appropriate up-to-date product configuration loaded on your field device and that you have successfully connected your field device and communication device to the register.
1. From the FieldLogic Tools Device Summary page, select Configure.
2. The register configuration process begins.
After successful configuration, a confirmation screen displays.
3. Select OK to return to the Device Summary screen.
Connect to an iPERL+ meter Before working with an iPERL+ meter, connect to it with an Android, iOS, or Windows 10/11 App field device and a CommandLink.
1. Power on the field device.
2. Power on the CommandLink.
3. Start the FieldLogic Tools application on your field device.
4. From the Connect screen, enter the FlexNet ID of the SmartPoint module using the keypad or bar code scanner and select the green Connect icon.
5. Check the CommandLink's LEDs to ensure that the blue LNK LED is illuminated, indicating a Bluetooth connection between the field device and the CL.
6. FieldLogic Tools attempts to communicate with the SmartPoint module through the
CL.
Activate and configure the SmartPoint module After physically installing the meter, you can activate it by connecting it to a SmartPoint module and then activating the SmartPoint module.
To activate the iPERL+ meter, you will need an Android, iOS, or Windows 10/11 App field device and a FieldLogic Communicator or an AutoGun.
Before activating a SmartPoint module, make sure that you have successfully connected your field device and communication device to the SmartPoint module.
1. From the FieldLogic Tools Device Summary page, select Activate.
2. If the GPS source is set to Required for all SmartPoints in the device configuration, and FieldLogic does not have a valid GPS fix, an activation error displays. Select OK to return to the SmartPoint module main menu.
3. If activating a dual port SmartPoint module, the Choose Port(s) screen displays.
Select the desired port, or select All Ports to activate both ports.
4. Select OK.
5. If prompted, select the applicable device configuration.
6. The activation process begins.
After successful activation, the Activate Success confirmation message displays.
7. Select OK to return to the Device Summary screen.
2 Installation | 15
8. From the activated SmartPoint module screen, select Disconnect to disconnect from the SmartPoint module.
Note: Be sure to disconnect from the SmartPoint module when finished to prevent multi-transmissions with LAT. This ends the meter to CommandLink communications in preparation for network operations.
Deactivate an iPERL+ meter An activated iPERL+ meter must be deactivated prior to maintenance, exchange, or removal.
1. From the FieldLogic Tools Device Summary screen, select Deactivate.
2. When the deactivation confirmation message displays, select Yes.
The deactivation process begins.
3. Select OK on the Deactivate Success screen to return to the Device Summary screen.
4. Select Disconnect to disconnect from the SmartPoint module.
Replace an existing iPERL+ To replace an existing meter with the iPERL+:
1. If connecting with a SmartPoint module, deactivate the SmartPoint module using steps from Deactivate an iPERL+ meter on page 16.
2. Turn off the water supply valve.
3. Pull the current meter out of the pit or disassemble the current meter.
4. Follow the installation steps as detailed in Installing iPERL+ on page 12.
5. Attach the existing SmartPoint module, if one was attached to the meter you are replacing, to the new meter.
6. Activate the SmartPoint module using FieldLogic Tools as described in Activate and configure the SmartPoint module on page 15.
2 Installation | 16
3 iPERL+ operations When operating iPERL+, details can be viewed through direct connection, SmartPoint, and Device Manager.
Data logs are accessed through direct connection.
View iPERL+ meter details View or audit the status, configuration parameters, and network settings of an iPERL+ meter in a read-only state.
Note: The parameter setting fields are read-only, and display settings that are stored in the SmartPoint module. To modify these settings, you must use a product configuration containing the applicable values.
1. From the FieldLogic Tools Device Summary page, select View Details.
The Port 1 and Port 2 sections, if applicable, report identical information that is divided into three subsections: Status, Register Settings, Alarm Settings. Scroll on your device to view these different sections.
The Alarm Settings section displays backflow, high flow, and leak detection threshold settings.
2. Scroll to the Network section to view network-specific information such as FlexNet IDs, utility code, and encryption status.
3. Select Close to return to the Device Summary screen.
View iPERL+ details (Device Manager) To take advantage of the iPERL+'s advanced functionality, the Device Manager operator must enable these functions in the AMI fixed-base network. If you are in an AMI fixed-base network, you can view details through Device Manager.
From the Devices menu > Meters tab, select the applicable device.
From the About this Device page, you can see the status of the , view the reads, the transmit rate, and so on.
Connect directly to an iPERL+ meter Connect directly to the iPERL+ meter instead of through the SmartPoint module.
You will need a field device with FieldLogic Tools, a FieldLogic Communicator, and a touchcoupler cable.
1. Power on the field device.
2. Power on the FieldLogic Communicator.
3. Connect the FieldLogic Communicator to the field device.
4. Connect one end of the coupler cable to the FieldLogic Communicator.
5. Start the FieldLogic Tools application on your field device.
3 iPERL+ operations | 17
View iPERL+ meter register details View iPERL+ meter details through the register.
You can access information about the iPERL+ meter using FieldLogic Tools through the direct connection method instead of through connecting to a SmartPoint module if you are not in a fixed base network.
Note: If you are using FieldLogic Tools to view device details through a SmartPoint module in a fixed base network, then the View Details function presents different information. For example, viewing details directly through the register will not display any port information, because only SmartPoint modules have ports.
1. From the FieldLogic Tools Device Summary page, select View Details.
FieldLogic displays the details available for the iPERL+. Scroll to view all details.
2. Select Close to return to the Device Summary screen.
View sensor readings View sensor readings through the details screen on an activated SmartPoint.
The sensors need to be enabled in Device Manager before the readings display in FieldLogic.
1. From the activated SmartPoint screen, select View Details.
The Status screen of the Port 1 tab displays the Pressure and Temperature readings.
2. Select the right arrow to view the Register Settings. The "Type" now displays Smart
Meter in addition to TouchCoupler.
3 iPERL+ operations | 18
4 iPERL+ alarms iPERL+ alarms provide information about the meter's functions.
The length of time that the alarms remain is customizable to ensure that operators catch all alarms that have been triggered since the last visit to the meter.
iPERL+ alerts The following information describes the alarms, errors, and warnings for the iPERL+ meter.
iPERL+ user configurable alerts Meter event name Event description Event trigger Event threshold
Continuous Flow This alarm indicates the meter has detected continuous flow for an extended time period.
For example, a leak on the downstream of the meter.
Option: Enabled / Disabled Default:
Enabled in Smart Mode
Trigger duration:
24 Hours (default) 48 Hours, 72 Hours
Gallons per minute:
0.11 GPM, 0.25 GPM,
0.50 GPM, 0.75 GPM,
1.00 GPM, 1.25 GPM,
1.50 GPM.
Defaults: 5/8" & 5/8"x3/4" ,0.11 GPM;
3/4", 0.11 GPM;
1", 0.25 GPM.
Cubic feet per hour:
0.88 CF/HR, 2.00 CF/HR,
4.00 CF/HR, 6.00 CF/HR,
8.00 CF/HR, 10.00
CF/HR, 12.00 CF/HR.
Defaults: 5/8" &
5/8"x3/4", 0.88 CF/HR;
3/4", 0.88 CF/HR; 1",
2.00 CF/HR.
Cubic meters per hour:
0.025 M3/HR, 0.050
M3/HR, 0.110 M3/HR,
0.170 M3/HR, 0.220
M3/HR, 0.280 M3/HR,
0.340 M3/HR
Imperial Gallons Per minute:
Currently not supported in iPERL+
4 iPERL+ alarms | 19
Meter event name Event description Event trigger Event threshold
High Flow The high flow alarm indicates the meter has detected an excessive flow rate, possibly caused by a broken pipe.
Option: Enabled/
Disabled. Default:
Enabled in Smart Mode
Trigger Duration:
1 hour (Default), 2 hours, 3 hours, 4 hours, 8 hours, 12 hours, 16 hours, 20 hours, 24 hours.
Gallons per minute:
20.00GPM, 25.00 GPM,
30.00 GPM, 35.00 GPM,
40.00 GPM, 45.00 GPM,
50.00 GPM, 55.00 GPM.
Defaults:
5/8", 25.00 GPM;
5/8"x3/4" & 3/4", 35.00
GPM; 1", 55.00 GPM.
Cubic feet per hour:
160.00 CF/HR, 200.00
CF/HR, 240.00
CF/HR, 280.00 CF/HR,
320.00 CF/HR, 360.00
CF/HR, 400.00 CF/HR,
440.00 CF/HR.
Defaults:
5/8", 200.00 CF/HR;
5/8"x3/4" & 3/4", 280.00
CF/HR; 1", 440.00
CF/HR.
Cubic meters per hour:
4.50 M3/HR, 5.70
M3/HR, 6.80 M3/HR,
7.90 M3/HR, 9.00
M3/HR,
10.20 M3/HR, 11.40
M3/HR, 12.40 M3/HR.
Defaults: 5/8", 5.70
M3/HR; 5/8"x3/4" &
3/4", 7.90 M3/HR; 1",
12.40 M3/HR.
Imperial Gallons Per minute:
Currently not supported in iPERL+
4 iPERL+ alarms | 20
Meter event name Event description Event trigger Event threshold
Reverse Flow A reverse flow alarm indicates the endpoint has detected reverse flow (decreasing reading values) for a specified period of time.
Option: Enabled / Disabled Default:
Enabled in Smart Mode
Trigger duration:
1 min (default), 2 min, 4 min, 6 min, 8 min, 10 min, 15 min, 30 min, 60 min.
Gallons per minute:
-1.00 GPM, -2.00 GPM,
-4.00 GPM, -6.00 GPM,
-8.00 GPM, -10.00 GPM.
Default: -1.00 GPM for all sizes.
Cubic feet per hour:
-8.00 CF/HR, -16.00
CF/HR, -32.00 CF/HR,
-48.00 CF/HR, -64.00
CF/HR, -80.00 CF/HR.
Default: -8.00 CF/HR for all sizes.
Cubic meters per hour:
-0.22 M3/HR,- 0.45
M3/HR, -0.90 M3/HR,
-1.36
M3/HR, -1.82 M3/HR,
-2.27 M3/HR.
Default: -0.22 M3/HR for all sizes.
Imperial Gallons Per minute:
Currently not supported in iPERL+ iPERL+ pre-defined alarms Meter event name Event description Event trigger
Hardware Failure Set if a catastrophic hardware problem occurred. Failure conditions cover processor failure and meter calibration corruption.
Trigger Condition:
User Experience:
Meter experienced a processor hardware glitch or meter factory calibration has been defaulted.
Recommend further inspection of alarm data to verify valid meter calibration.
Technical Details:
-USC failure (oscillator fault, system clock failure).
or
-The calibration structure, which is stored in non-volatile INFOMEM, is corrupt and set to defaults.
Clear Condition:
After triggered this alarm is permanently set to active. The alarm can only be cleared via command.
4 iPERL+ alarms | 21
Meter event name Event description Event trigger
Non-Volatile Memory Error Indicates a failure when attempting to read the newest version of a file stored in internal flash during normal operations (excluding Datalog reads), or a failure to initialize the calibration structure in non-volatile INFOMEM.
Update:
When flash files are read on bootup or accessed in response to a command.
Trigger Condition:
User Experience:
Possible loss of the most recent metrology/alarm history, or meter calibration has been loaded with defaults.
Only possible with meter reboot.
Recommend further inspection of alarm data to verify valid meter calibration.
Technical Details:
-Calibration structure could not get loaded with the Master Calibration file or Backup Calibration file.
or
-Loaded a file data entry which is not the newest in the given Flash file.
or
-Error opening a Flash file.
Clear Condition:
This is a one-shot type alarm. It is automatically set to inactive after triggered.
Empty Pipe Alarm indicates the absence of water in the flow tube.
Update: Alarm condition is evaluated every ASIC field sample period.
Trigger Condition:
User Experience:
Absence of water in the meter’s flow tube for 5 minutes continuously.
Technical Details:
Metrology measured impedance exceeds threshold for 5 minutes continuously.
Clear Condition:
Alarm is set to inactive when conditions return to normal.
4 iPERL+ alarms | 22
Magnetic Tamper Detected an attempt to tamper with the meter by application of a magnet.
Update: Alarm condition is evaluated every ASIC field sample period.
Trigger Condition:
User Experience:
An external magnetic field applied to the flow tube disrupts normal flow measurement.
Typically indicates an attempt at tampering to stop proper metering.
Technical Details:
If the change in magnetic field per microsecond of field drive is out of range, the alarm will be triggered.
Condition must present for 15 minutes continuously.
Clear Condition:
Alarm is set to inactive when conditions return to normal.
Near End-of-Life The meter is approaching the end of the expected product life.
Update: Alarm condition is evaluated hourly.
Trigger Condition:
User Experience:
The meter has been operating for
20.5 years, and the battery is nearing exhaustion.
Technical Details:
After 20.5 years have elapsed since meter’s stored time of manufacture.
Clear Condition:
Alarm is set to inactive when the “End-of-Life" alarm becomes active.
End-of-Life The meter has reached the end of expected product life.
Update: Alarm condition is evaluated hourly.
Trigger Condition:
User Experience:
The meter has been operating for 21 years, the battery exhaustion is imminent.
Technical Details:
After 21 years have elapsed since meter’s stored time of manufacture.
Clear Condition:
Once conditions are met this alarm is permanently set to active.
4 iPERL+ alarms | 23
Internal Communication Error Indicates a hardware communications error occurred between the metrology processor and the ASIC.
Trigger Condition:
User Experience:
The meter’s processor experienced a hardware related communication glitch with the metrology ASIC.
Technical Details:
Hardware or communication failure during ASIC initialization or run-time sampling.
Note: A communication hard lockup of the ASIC chip or SPI bus typically results in a processor reboot in an attempt to recover.
Clear Condition:
Alarm is set to inactive when conditions return to normal.
Reboot Occurs if the meter has been rebooted due to hardware issue or firmware upgrade.
Trigger Condition:
User Experience:
The meter rebooted. Typically seen after a firmware upgrade.
Technical Details:
Processor reboot due to hardware/firmware issue or firmware upgrade completed.
Clear Condition:
This is a one-shot type alarm. It is automatically set to inactive after triggered.
4 iPERL+ alarms | 24
EMF Range Voltage between the two electrodes is too large to measure water flow.
Update: Alarm condition is evaluated every ASIC field sample period.
Trigger Condition:
User Experience:
Electrode voltage readings are too high for flow sensor to accurately calculate the flow measurements.
Technical Details:
Conditions are evaluated when meter has been out of Empty Pipe state for 2.5 days (default), and the condition is present for 15 min. continuously.
-Absolute value of the electrode delta (differential voltage between the electrodes) > 180mV.
or
-The…
This is the start of the file's text. The full file is on GovTribe.