This document appears to be a product catalog from Alpha Technologies Ltd. featuring transfer switches, enclosures, batteries, and battery accessories for outdoor power solutions, primarily targeting transportation infrastructure applications such as traffic systems. The materials are designed for use in various environmental conditions, with a focus on reliability for state and local transportation departments, specifically mentioning Department of Transportation (DOT) requirements.

The product line includes Universal Automatic Transfer Switches (UATS and UGTS) for 120V/30A and 230V/16A configurations, outdoor traffic enclosures in multiple sizes (TE27-2218, SE41-2722, SE48-1616, SE48-2216, SE48-1909), AlphaCell XTV AGM batteries with 5-year warranties, and battery management accessories like the AlphaGuard Charge Management System and battery testing equipment. The products are engineered for extreme temperature performance, with features such as thermal management, surge protection, generator connectivity, and options for battery heating in cold weather environments. The catalog emphasizes system flexibility, extended battery life, and comprehensive monitoring capabilities for critical infrastructure power systems.

View the file

Other files

File Type Posted
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
1-ODOT_106_Group7_detector_racks_TS1.pdf PDF
1-ODOT_106_Group8_Item_8-01.pdf PDF
1-ODOT_106_Group9_Alpha_PBT.pdf PDF
1-ODOT_106_Group9_Alpha_UPS_Riser.pdf PDF
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_EL720_cabinet.pdf PDF
1-ODOT_106_Group8_Item_8-03.pdf PDF
1-ODOT_106_Group9_Alpha_FXM1100HP_Inverter.pdf PDF
1-ODOT_106_Group9_Mini_Battery_Backup_System.pdf PDF
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tran sfer &

B yp ass S w itch es

Outdoor Solutions

Alpha Transfer Switches n 120V/30A n 230V/16A

Alpha's Universal Automatic Transfer Switch is designed as a three stage bypass switch that allows for the UPS to be bypassed and still maintain the ability to keep batteries fully charged.

It acts as a fail-safe device by switching the critical load to the utility line should a fault occur in the UPS. The UATS ensures that clean power is always provided to the critical load, ensuring that your mission-critical equipment always remains running in the event of an outage. This transfer switch also includes a stan-dard manual bypass switch which eliminates costly equipment downtime while servicing the UPS or replacing the batteries.

Dimensions:

mm: 81H x 135W x 152D inches: 3.25H x 5.3W x 6.0D

Mounting options:

Wall, shelf or single side rack mount

Rack mount options can be configured with Surge block, UGTS, UATS or a receptacle plate for powering optional battery heater mats.

n 120V/30A n 230V/16A

Alpha’s Universal Automatic Generator Transfer Switch automatically transfers the input to the UPS from the utility line to a portable AC generator.

The UGTS allows the generator to recharge the batteries and ensure your mission - critical equipment remains in operation during extended power outages. For manually connecting or disconnecting a generator, a standard switch is included.

Dimensions:

mm: 81H x 135W x 152D inches: 3.25H x 5.3W x 6.0D

Mounting options:

Wall, shelf or single side rack mount

19/23 Rack mount configurations

Universal Automatic Transfer Switch

Universal Automatic generator Transfer Switch

Tr an sf er

B yp as s S w it ch es

Configurations

Alpha Transfer Switches

Surge Assembly The Surge Assembly comes with a UL listed Type 1

Surge Protection Device suitable for use on:

• Surge Entrance

• Distribution panels

• Point of use application

Universal Automatic Transfer Switch The UATS ensures continuous operation of your systems either with conditioned line power, battery backup power or power direct from the line should the UPS require maintenance.

Receptacle Plate The receptacle plate provides connection point for UPS backed up customer load, internal enclosure AC lamp and convenience receptacle for non-critical loads like battery heater mats.

UGTS

The Universal Automatic Generator Transfer

Switch (UGTS) automatically transfers the input to the UPS from the utility line to a portable AC generator. The UGTS allows the generator to recharge the batteries and power your systems during extended power outages.

19" rack mount shelf option is offered in few different configurations based on application. In option 1 is precon-figured with surge arrestor, UATS and receptacle plate assembly. In option 2 assembly comes preconfigured with UGTS and a UATS.

Other configurations are available.

Consult your Alpha representative for P/N

From Generator

To Heater Mat

To LoadFrom Utility

To LoadFrom Utility

To UPS

From UPSTo UPS

From UPS

Option 1

Option 2

E n clo su res

Alpha Enclosure Solutions Alpha offers a complete line up of NEMA 3R traffic enclosures both in aluminum and stainless steel that are designed and tested to meet the highest industry operating standards. Each enclosure maintains a clean and dry environment ensuring an extended life and enhanced reliability of the power electronics and batteries. Alpha enclosures provide application flexibility with a variety of mounting options, choice of enclosure color, thermal management solutions, security level, generator connectivity, heaters and many other options and features. When an Alpha outdoor enclosure is combined with either an FXM Outdoor AC UPS or Cordex

DC power system and AlphaCell batteries, the result is an optimally designed, highly-reliable and efficient outdoor power system that provides easy installation and long term operation.

TE27-2218 is a cost-effective and versatile traffic enclosure solution ideal for space constrained intersections. The cabinet can be pole, host, wall, or pedestal mounted and can accommodate Alpha’s FXM UPS and up to four AlphaCell™ 85GXL or 195 GXL front terminal batteries. With a small form factor, the TE27-2218 is the perfect choice for intersections where limited real estate and need for discretion are key challenges.

SE41-2722 is a configurable-to-order system suitable for ITS applica-tions. The cabinet provides up to 20RU of total equipment space for power, batteries, accessory panel and customer equipment. Flexible thermal management solutions (including fan, heat exchanger and air conditioning variants) enable convenient matching to load and environmental parameters.

SE48-1616 is one of the most popular traffic enclosures sold today. It is designed to accommodate an FXM UPS module, transfer switches and four (4) AlphaCell 220 GXL batteries (BCI Group 31), with additional room for other components. Thermostat controlled fan and louvered vents ensure reliable operation of the system in high temperature environments.

SE48-1616 is available in multiple colors to meet DOT requirements for the state, county or the city.

SE48-2216 is a new addition to the Alpha traffic enclosure line up. The enclosure design is based on the popular SE48-1616 enclosure but with one main difference being width. The SE48-2216 is designed to accommo-date a FXM UPS module, transfer switches and four (4) AlphaCell 220

GXL batteries (BCI Group 31), with additional room for other components.

Thermostat controlled fan and louvered vents ensure reliable operation of the system in high temperature environments.

SE48-1909 is a battery only enclosure designed to hold four (4)

AlphaCell 220 GXL batteries (BCI Group 31). It is rated for NEMA 3R protection for the batteries from outdoor elements. The SE48-1909 is a cost-effective method of adding 48Vdc standby capacity to any existing ground mount enclosure where there is no room inside the existing traffic enclosure for the batteries.

ssours Highlight

E n cl o su re s

> �Traffic grade aluminum enclosure protects battery backup power systems (BBS) from outdoor elements

> �Various mounting options (including pole-mount) provide a flexible solution for traffic applications

> �Large sun shield reduces solar heat load inside the cabinet

> �Thermostat controlled fan and louvered vents ensure reliable operation in high temperatures

> �180° stainless steel piano hinged door with two locking open positions makes internal component installation and maintenance easy and convenient

> �Three-point latching mechanism with Corbin Type 2 lock (or optional Best lock) for maximum security

> � 5-Year “No Worries” Warranty providing full coverage of your Alpha S6 enclosure system*

Consult your Alpha representative for P/N configurations

Mechanical

Dimensions:

mm:..................................1220H x 419W x 419D inches:.............................48H x 16.5W x 16.5D

Weight:..............................34kg (75lbs) Construction:...................High strength corrosion resistant aluminum Finish:...............................Natural aluminum Equipment space:............8RU space (without generator inlet) with two

(2) battery shelves Equipment rails:...............�EIA standard 19" (vertical) Cable entrance:..................Bottom of enclosure: 1 x 76mm (3") dia. knock-out

Hardware

Hinge type:.......................Stainless steel piano hinge Door prop:.........................Aluminum rod, 2 locking open positions Handle:..............................�Stainless steel handle with padlock fitting for extended life and improved look Door latch:........................�3 point latch with integrated Corbin Type 2 lock

(or optional Best lock) for maximum security

HVAC

Cooling:............................�Thermostat controlled 48Vdc fan, 100 cfm or better, ON at 49°C (120°F) Off at 32°C (89°F) Ventilation:.......................Door installed louvers

Environmental

Temperature:

Operating:.......................-40 to 46°C (-40 to 115°F) Storage:...........................-40 to 85°C (-40 to 185°F)

Installation

Access:.............................�Removable bottom shelf for easy wiring access

Maintenance

Door installed louver:......�Equipped with washable filter Other:................................�Bug screen protected top vent

Enclosure Options

Mounting:..........................Side mount (standard) - designed to mount to

the side of most traffic enclosure cabinets
Ground mount kit (optional)
Pole mount kit (optional)

System Specifications (as shown)

• 2 Battery shelf with 4x AlphaCell 220GXL batteries

• FXM1100 UPS

• Universal automatic transfer switch

• Universal generator transfer switch

>System Options

• �Generator support: locking generator access door and L5-30 F1 plug

• Tamper switch

• Tilt switch

• AlphaGuard™ battery balancer

• Door activated interior light

• Battery heater mats

• "On Battery" indicator light

Agency Compliance

CSA/UL, CE:.....................UL50E/C22.2 No.94 NEMA rating:....................3R

* �The 5 Year “No Worries” Warranty applies to bundled systems consisting of at least an Alpha S6 enclosure, an Alpha FXM UPS module and AlphaCell GEL batteries.

48" Outdoor Traffic BBS Enclosure

SE48-1616 (Formerly S6)

B atteries

Nominal Specifications

Model 100XTV 150XTV 195XTV 240XTV

P/N 1810226 1810227 1810228 1810229

Warranty1 5-year full replacement

Operating Temperature Range (w/Temperature Compensation)

-40 to 60°C (-40 to 140°F) (charger temperature compensation @ ±3.3mVpc per °C)

Storage Temperature -10 to 40°C (14 to 104°F) -10 to 40°C (14 to 104°F) -10 to 40°C (14 to 104°F) -10 to 40°C (14 to 104°F)

Self Discharge Battery can be stored up to 12 months at 25°C (77°F).

Higher temperatures during storage will require more frequent recharge.

Voltage Per Unit 12V 12V 12V 12V

Float Charge Voltage 13.5 to 13.8Vdc average per 12V unit at 25°C (77°F)

Refresh/Boost Charging Voltage 14.4 to 15.0Vdc average 12V unit at 25°C (77°F)

Maximum AC Ripple (Charger) 0.5% RMS or 1.5% of float recommended for best results. Maximum voltage allowed = 4% P/P

Terminal Type Threaded alloy insert terminal to accept M6 x 12mm bolt Threaded alloy insert terminal to accept M6 x 20mm bolt

Terminal Hardware Torque 13.6NM / 120in-lbs 13.6NM / 120in-lbs 13.6NM / 120in-lbs 13.6NM / 120in-lbs

Case Sizes 22NF 24 27 31

Mechanical

Dimensions w/terminals mm 207H x 138W x 228D 214H x 168W x 275D 214H x 322L x 169W 217H x 343L x 170W inches 8.17H x 5.46W x 9.01D 8.44H x 6.65W x 10.85D 8.43H x 12.71L x 6.67W 8.57H x 13.50L x 6.71W

Weight 17.7kg (39lbs) 25.4kg (56lbs) 30.5kg (67lbs) 32kg (75lbs)

Battery

Runtime Rating 25A (@ 25°C/77°F to 1.75Vpc)

100 minutes 150 minutes 195 minutes 240 minutes

Amp Hour Capacity 20Hr Rate (@ 25°C/77°F to 1.75Vpc)

56Ah 80Ah 100Ah 110Ah

Conductance Range Fully Charged New Battery (@ 25°C/77°F)

700 - 800 900 - 1100 1050 - 1250 1250 - 1550

Current Discharge Ratings Table in Amps (end Voltage 1.75VPC @ 25°C/77°F)

Hours 1 2 3 4 5 6 8 10 12 20

100XTV 39.4 22.1 15.8 12.4 10.3 8.7 6.7 5.4 4.6 2.8

150XTV 53.0 30.6 21.6 16.8 13.9 11.9 9.3 7.7 6.5 4.0

195XTV 65.5 37.6 26.9 21.0 17.3 14.7 11.3 9.4 7.9 5.0

230XTV 75.6 42.5 30.3 23.9 19.5 16.5 12.8 10.4 8.8 5.5

1. Warranty varies by country and region. Warranty valid only when used with Alpha approved power supplies, chargers and enclosures in US/Canada. Consult your salesperson or manual for details.

> �Extreme temperature Absorbed Glass Mat (AGM) technology

> �Significant cold temperature performance improvement over gel

> �Longer runtimes help increase network reliability

> �Multiple models provide options for all network architectures

> �Power density gains allow more runtime from smaller sized battery

> �Extended service life for non-temperature controlled outdoor enclosures

> �Full 5-year replacement warranty1

AlphaCell™ XTV AGM Top-Terminal Battery ssours Highlight ssours Text Box ALPHACELL 240XTV 112 ah battery.

The Remote Battery Monitoring System (RBMS) from Alpha provides detailed, real time information on batteries, reducing unnecessary costly truck rolls, and ensuring actual outage backup times are not unknowingly compromised by degraded batteries. Scalable up to 2 strings of 4 batteries each, the system provides detailed information on every battery, from admittance to individual battery temperatures and string voltages.

This, and a wealth of other information (including alarms) can be monitored directly via SNMP. Unit has a built-in SNMP proxy, a built-in web server and a built-in SMTP mail client.

> �Compact, intelligent and cost effective system for determining battery condition remotely

> �Monitors each individual 12V battery via a user programmable schedule, from hourly to monthly

> ��Intelligent battery balancing extends the life of the battery string and reduces maintenance costs

> ��Automatic data logging function records individual battery voltage, temperature and admittance

> Enables the scheduling and budgeting of battery replacements

> �Built-in web server allows for convenient read-only monitoring from any internet-connected computer

Remote Battery Monitoring System Plus Real-Time Measurement and Control ssours

Optional

Alpha Technologies Ltd. � For more information visit www.alpha.ca

Canada: Burnaby, British ColumbiaT: 604.436.5900F: 604.436.1233 � #0470289-00 Rev B (06/2017)
United States: Bellingham, WashingtonT: 360.647.2360F: 360.671.4936

Alpha Technologies reserves the right to make changes to the products and information contained in this document without notice.

Copyright © 2017 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies.

member of The Alpha Group™ is a trademark of Alpha Technologies.

Remote Battery Monitoring System Plus 48Vdc 1 String: 0370260-002 48Vdc 2 Strings: 0370260-003

ELECTRICAL

Site controller unit:

Voltage:............................21 – 59Vdc Power consumption:........7W NOTE: Power is supplied from the battery bank

Sensors:

Voltage:............................12V: 8.0 – 16Vdc Power consumption:........�12V: �<10mA nominal, 0.5/6A during admittance test

MECHANICAL

Site controller unit:

Dimensions:

mm:..............................32H x 104.15W x 120.15D inches:..........................1.26H x 4.1W x 4.73D Weight:.............................0.242kg (0.53lbs)

Sensors (12V)

• Two-wire connection with max bolt size for terminals of 5/16 inch

• �Mounted to the top of the battery with self-adhesive industrial Velcro strip

• CAT5 cable used to daisy chain from sensor to sensor

• �Last sensor in the daisy chain connects to String 1 for the first battery string

• �Last sensor in the daisy chain connects to String 2 for the second battery string

Power harness cable connection

• Connects to the 48Vdc battery string + (Red) and – (Black) terminals

OPTIONAL ACCESSORIES

Equipment P/N

AC Output Current Sensor 7400583

Moisture Sensor 7400162

120V AC wall transformer, for monitoring utility power voltage

0180059

Two wire sensor, High Current* 0180055

Battery cable to power RBMS Controller* 8701040

*included with 0370260-002/003 kit

ENVIRONMENTAL

Operating temperature:....-40 to 80°C (-40 to 176°F)

COMMUNICATIONS

Site controller unit

• SNMP via TCP/IP & built-in web server and SMTP mail client

Site controller software

• �Optional Lookout software provides a convenient way to monitor multiple site controllers on the network atteries

> �Durable polyester construction

> �Sealed on-mat electronics for maximum protection

> �On-mat thermal switch and thermal fuse for redundant safety

> �Insulated design directs heat to the batteries not the enclosure for a 30% reduction in power consumption

> Piggyback plug standard on 120V models

Battery heater mats are an integral component in outdoor power solutions and need to be carefully integrated with the other system elements to ensure effective operations.

Please contact your Alpha representative to determine the proper battery heater mat required for your outdoor power system.

Line Cord Thermostat Turn on Temperature:.........5°C (41°F) Turn off Temperature:.........15°C (59°F)

Mat Mounted Thermostat Over Temperature Off:.......50°C (122°F) Turn Back on:.....................40°C (104°F) Thermal Fuse Rating:.........85°C (185°F)

Optional Line Cord Thermostat.........................Turn on Temperature:......................0°C (32°F) Turn off Temperature:.........10°C (50°F)

The main power connector (1) on the heater mat is plugged into an AC source. In low temperature conditions the main control thermistor (2) will allow power to flow to the heater mat coil (5). The thermistor is mounted on the power cord so that it reacts to the enclosure temperatures and not the mat surface temperature. A secondary thermistor (3) is mounted on the mat with significantly higher temperature settings than the main thermistor (2). This thermistor keeps the mat from overheating during extended run periods. A thermal fuse (4) is a final fail safe device. The power connector (1) has an AC receptacle so that additional mats can be plugged in. Its parallel wiring keeps the failure of the first mat from affecting the operation of others in the string.

Extend Battery Runtime in Cold Weather

Battery Heater Mats ssours

Heater Mats set of 4 required per system at te ri es

Battery Accessories

AG-CMT-4 AlphaGuard™ Charge Management SC, 48V String – including Battery interface cable

The AlphaGuard is a battery charge management system that monitors and protects your batteries for runtime optimization and longer battery life. CSA and UL approved, AlphaGuard allows you to replace single batteries rather than the whole string.

It spreads charge voltage equally across batteries to maximize battery life and compensates for battery differences as they age.

• �Designed for use with most group 27 (165GXL) or 31 (3.5HP, 4.0HP, 195GXL, 220GXL) VRLA batteries

• Easy to install - clips to the top of the battery

• �Increases battery life expectancy by providing critical battery spacing required for proper ventilation

• �Accurately positions and secures the Remote Temperature

Sensor (RTS)

• Strongly recommended for hot climates

• Designed to last over 30 years or lifetime of the equipment

Alpha’s battery testing equipment provides accurate information about the status of installed standby batteries allowing you to budget for early detection of failed or degraded batteries and for replacements with confidence.

A fast, reliable and affordable testing process.

Conductance testing, coupled with a simple utility load test, arms the operator with the quality of data necessary to know the status of installed standby batteries, allowing for detection and replacement before failure occurs and puts backup during an outage at risk.

Battery Testing Equipment

Battery Spacer Clip

AlphaGuard™ Battery Charge Management System ssours Rectangle

File details come from the government source that posted it. Updated .