1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf

PDF 160 KB Posted

Attached to
Competitive Selection OH|DOT10626-1
Contract number
DOT10626-1
Issued by
Ohio

About this file

This document is a product catalog sheet for the MMU2-16LE SmartMonitor, a NEMA LCD Malfunction Management Unit manufactured by Eberle Design Inc. (EDI), a U.S.-based company located in Phoenix, Arizona. The catalog sheet details a traffic signal monitoring device designed to comply with NEMA TS2-2003 (R2008) standards and MUTCD (Manual on Uniform Traffic Control Devices) requirements, with specific models including MMU2-16LEip with an Ethernet port and MMU2-16LE with an EIA-232 port.

The product offers advanced features for traffic signal technicians, including a built-in Setup Wizard for configuration, a menu-driven LCD interface for viewing operational details, and a Diagnostic Wizard to automatically identify signal malfunctions. Key technical capabilities include standardized communications, full intersection status display, time-stamped event logging, support for Flashing Yellow Arrow PPLT operation, and compatibility with both TS-2 and TS-1 cabinet configurations. The device includes innovative technologies such as LEDguard signal monitoring, an EDI RMS-Engine for accurate voltage measurements, and the ability to store configuration settings on a removable Program Card. The catalog sheet is marked as ISO 9001:2008 registered and includes contact information for Eberle Design Inc.

View the file

Other files

File Type Posted
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group9_Alpha_FXM1100HP_Inverter.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group9_Mini_Battery_Backup_System.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group8_Item_8-03.pdf PDF
1-ODOT_106_Group7_Size_7_EL720_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group9_Alpha_PBT.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group7_detector_racks_TS1.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group8_Item_8-01.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group9_Alpha_UPS_Riser.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group8_Item_8-02.pdf PDF
106-26_spec_Bid_Doc..pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
1-ODOT_106_Group7_TF4200_Nema_TS2Type2_terminal_facilities.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MMU2-16LE Catalog Sheet – 120312 Designed, Manufactured and Tested in the United States of America ISO 9001:2008 Registered

SmartMonitor and LEDguard are registered trademarks of Eberle Design Inc. U.S. Pat. No. 7,246,037

Complies With The New

NEMA MMU2 Standard and MUTCD Requirements

MMU2-16LE SERIES

NEMA LCD MALFUNCTION MANAGEMENT UNIT

MMU2-16LEip wi th Ethernet Port MMU2-16LE wi th EIA-232 Port

Whether you’re a NOVICE or EXPERT

Use a built-in SETUP WIZARD to quickly and accurately configure the Signal Monitor to the exact requirements of the cabinet and intersection?

Signal Technician, wouldn’t it be great if you could:

Use a MENU DRIVEN LCD interface to view vital cabinet operational details such as field signal voltages, historical event logs, and monitor configuration data?

Use a built-in DIAGNOSTIC WIZARD to automatically diagnose cabinet malfunctions and pinpoint faulty signals?

If your answer is Yes, the MMU2-16LE SmartMonitor® is for YOU!

NEW MMU2-16LE SmartMonitor® ENHANCED FEATURES

NEMA TS2-2003 (R2008) Standard Including Amendment #4:

The MMU2-16LE SmartMonitor® meets all specifications of the NEMA Standard TS2-2003 (R2008) for the MMU2 configuration while maintaining compatibility with NEMA TS1-1989 Assemblies.

NEMA Standard Flashing Yellow Arrow PPLT:

The MMU2-16LE SmartMonitor® supports MUTCD Flashing Yellow Arrow PPLT operation and meets / exceeds the NEMA Standard MMU2 requirements of TS-2 Amendment #4-2012, providing modes for both TS-2 or TS-1 cabinet configurations.

Standardized Communications: Real-time SDLC communications with the Controller Unit exchanges field input status, Controller Unit output status, fault status, MMU programming, and time and date.

Full Intersection & Status Display: Two high contrast, large area Liquid Crystal Displays (LCD) continuously show full RYG(W) intersection status. A separate graphic LCD provides a menu driven user interface to status, signal voltages, configuration, event logs, and the Help system.

Event Logging: A time-stamped nonvolatile event log records the complete intersection status as well as AC Line events, configuration changes, monitor resets, temperature and true RMS voltages.

Setup Wizard: Use the built-in Setup Wizard to configure the Nema Enhanced settings of the SmartMonitor® by answering a short series of questions regarding intersection design and operation.

Diagnostic Wizard:

and Help System

The Diagnostic Wizard automatically pinpoints faulty signals and offers trouble-shooting guidance.

The integrated Help System provides context sensitive operational assistance.

TS-1 Type 12 with SDLC Mode: The MMU2-16LE SmartMonitor® can be configured to operate with the Port 1 SDLC function and Diagnostic Wizard enabled in a TS-1 twelve channel cabinet with no cabinet wiring changes.

Program Card Memory: Enhanced settings of the MMU2-16LE SmartMonitor® are stored in nonvolatile memory on the EDI Program Card. Moving the Program Card to another MMU2-16LE automatically transfers all settings.

Signal Sequence History Log: The five Signal Sequence History logs stored in nonvolatile memory graphically display up to 30 seconds of signal status prior to each fault event.

LEDguard®: This EDI innovative signal threshold technique can be used to increase the level of monitoring protection when using LED based signal heads.

EDI RMS-Engine: A DSP coprocessor converts AC input measurements to True RMS voltages, virtually eliminating false sensing due to changes in frequency, phase, or sine wave distortion.

ECcom PC Software: Access to the MMU2-16LE data is provided by the industry standard EDI ECcom Windows based software for status, event log retrieval, configuration, and data archival.

ssours Typewritten Text 10-3, 10-7 ssours Typewritten Text 10-5 ssours Typewritten Text