About this file

The document is a technical specification sheet for Eagle Detector Racks manufactured by Siemens Energy & Automation, Inc.'s Intelligent Transportation Systems (ITS) business unit, located in Austin, Texas. The documentation specifically covers two models of detector racks (DD1004 and DD1008) designed for TS-1 traffic signal cabinets, with detailed specifications from Mobotrex Eagle Traffic Control.

The Eagle Detector Racks are traffic signal hardware components with two model variants: DD1004 supports a power supply with 2 four-channel or 4 two-channel detector positions, while DD1008 supports a power supply with 4 four-channel or 8 two-channel detector positions. Each rack requires a specific power cable (DD1000-200) and detector cable (DD1000-201), and features a printed circuit backplane with plug connections that facilitate easy installation and troubleshooting. The racks have standardized physical dimensions (height: 5.388 inches, width: 9.595-14.343 inches, depth: 7.5 inches) and offer flexible channel configuration, with the ability to isolate output pins for different operational modes.

View the file

Other files

File Type Posted
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_EL720_cabinet.pdf PDF
1-ODOT_106_Group8_Item_8-03.pdf PDF
1-ODOT_106_Group9_Alpha_FXM1100HP_Inverter.pdf PDF
1-ODOT_106_Group9_Mini_Battery_Backup_System.pdf PDF
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
1-ODOT_106_Group7_TF4200_Nema_TS2Type2_terminal_facilities.pdf PDF
1-ODOT_106_Group8_Item_8-02.pdf PDF
1-ODOT_106_Group9_AlphaCell_Testing_11_A05__Celltron_Tester.pdf PDF
106-26_spec_Bid_Doc..pdf PDF
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Height: 5.388 inches (136.85 mm) Width: DD1004 = 9.595 inches (243.71 mm)

DD1008 = 14.343 inches (364.1 mm) Depth: 7.5 inches (190.5 mm) (does not include external cable connectors)

Models

Features

Physical Dimensions s EAGLE DETECTOR RACKS

FOR TS-1 CABINETS

Siemens ITS 8004 Cameron Road · Austin, TX 78754 Siemens Energy & Automation, Inc. Ph: (512) 837-8310 · Fax: (512) 837-0196 Business Unit Intelligent Transportation Systems http://www.itssiemens.com

Model DD1004: For Power Supply and 2 Four Channel or 4 Two Channel Detector Positions

Model DD1008: For Power Supply and 4 Four Channel or 8 Two Channel Detector Positions

Note: Each four channel position will accept 2 two channel detector modules.

Each rack requires:

Power Cable (P/N DD1000-200) for AC and DC voltage input.

Detector Cable (P/N DD1000-201) for each four channel detector position or each 2 adjacent two channel detectors.

DD1004 DD1008

Printed circuit backplane with plug connections for power and detector hookups. Discrete cables save tedious soldering to edge connector pins and facilitate troubleshooting and repair to detection systems.

All detector module pins are brought out so that timing capabilities of all channels may be uti-lized. While the "Output -" (emitter) pins are standardly tied to logic common on the backplane, they are isolatable by interrupting a clearly labeled connection. This allows the channel to be used in "calling" or "extend only" modes.

ssours Text Box Detector Rack TS1 with cables and power supply ssours Text Box Mobotrex

EAGLE TRAFFIC CONTROL

ssours Rectangle ssours Highlight

Cable Hookup Data

DD1000-200 DD1000-201

Power Cable Detector Cable**

PIN Function PIN Function 1 AC Line 1 Channel 1 Green Input 2 AC Neutral 2 Channel 2 Green Input 3 Safety Ground 3 Channel 3 Green Input 4 Logic Common 4 Channel 1 Loop Input 5 Reset 5 Channel 1 Loop Input 6* External +24 Volts 6 Channel 1 Output (+)

7 Channel 2 Loop Input 8 Channel 2 Loop Input 9 Channel 4 Green Input

10 Channel 3 Loop Input 11 Channel 3 Loop Input 12 Channel 3 Output (+) 13 Channel 4 Loop Input 14 Channel 4 Loop Input 15 Channel 2 Output (+) 16 Channel 4 Output(+) 17 Channel 1 Output (-) 18 Channel 2 Output (-) 19 Channel 3 Output (-) 20 Channel 4 Output (-)

Notes:

*Power cable pin 6 is used only if an external DC power supply is required, 4 diodes are then installed on the motherboard to common the DC inputs to the detector positions.

**The detector channel outputs (-) are tied to logic common on the motherboard but are isolatable by removing circuit track jumpers.

Siemens ITS 8004 Cameron Road · Austin, TX 78754 Siemens Energy & Automation, Inc. Ph: (512) 837-8310 · Fax: (512) 837-0196 Business Unit Intelligent Transportation Systems http://www.itssiemens.com

File details come from the government source that posted it. Updated .