This document appears to be a detailed product specification sheet for the Alpha FXM HP 1100 Rugged UPS Module, manufactured by Alpha Technologies Services, Inc., an EnerSys company. While the document does not explicitly outline a state or local contract, it provides comprehensive technical specifications for a high-performance Uninterruptible Power Supply (UPS) designed for extreme environments and critical applications such as security, communications, traffic, and industrial systems.

The FXM HP 1100 is a 1100W/VA UPS module available in 120VAC and 230VAC models with advanced features including a high-resolution color touchscreen LCD, built-in data loggers, integrated USB host for firmware upgrades, wide range Automatic Voltage Regulation, and multiple communication ports. It offers robust performance specifications, including an operating temperature range of -40 to 74°C, up to 95% non-condensing humidity, and a Mean Time Between Failure (MTBF) of 250,000+ hours. The device includes programmable dry contacts, SNMP and TCP/IP protocols, and meets various agency compliance standards such as UL 1778, CAN/CSA-C22.2, and EN 62040-1 electrical safety certifications.

View the file

Other files

File Type Posted
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_EL720_cabinet.pdf PDF
1-ODOT_106_Group8_Item_8-03.pdf PDF
1-ODOT_106_Group9_Mini_Battery_Backup_System.pdf PDF
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
1-ODOT_106_Group7_TF4200_Nema_TS2Type2_terminal_facilities.pdf PDF
1-ODOT_106_Group8_Item_8-02.pdf PDF
1-ODOT_106_Group9_AlphaCell_Testing_11_A05__Celltron_Tester.pdf PDF
106-26_spec_Bid_Doc..pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

• 1100W/VA UPS designed to operate in extreme environments and provide maximum flexibility

• Advanced next-generation control and monitoring platform with high resolution color touchscreen LCD display with advanced local UI

• Built-in data loggers to monitor performance logs, user configurable alarms and advanced equation editing for custom data and actions

• Integrated USB host for local firmware upgrades, configuration updates, backup, restoration and cloning

• Wide range Automatic Voltage Regulation (AVR) lengthens battery life by providing protection without transferring to backup mode during voltage surge or sag

• Independently programmable control and reporting dry contacts allow monitoring and controlling of key functions

The FXM HP UPS continues the longstanding excellence in Battery Backup Systems by ensuring equipment in security, communications, traffic, industrial environments, and many other critical applications remains safe and protected from power disturbances and outages.

Thanks to its powerful programmable temperature compensated battery charger, the FXM UPS is capable of providing the runtime and extended battery life you need. The FXM HP colored LCD touchscreen display provides access to multiple configurable tabs for quick system status, overview and configuration without the need of a laptop.

Multiple communication ports including two Ethernet connections permits simultaneous local craft access as well as permanent LAN/WAN connectivity. A USB key may also be used to quickly backup and restore site configuration settings and data logs.

Enhanced security using modern encryption technology ensures proper authentication and privacy for remote connection with the UPS. Environmental conditions and other equipment can be monitored via a single IP interface via CAN port using Alpha® Analog Digital Input Output (ADIO) devices.

FXM HP 1100

Rugged UPS Module

Alpha Technologies Services, Inc. USA: 3767 Alpha Way, Bellingham, WA 98226 Canada: 7700 Riverfront Gate, Burnaby, BC V5J 5M4 Toll Free North America: +1 800 322 5742 Outside US: +1 360 647 2360 Technical Support: +1 800 863 3364 For more information visit www.alpha.com © 2021 Alpha Technologies Services, Inc. All Rights Reserved. Trademarks and logos are the property of Alpha Technologies Services, Inc.

and its affiliates unless otherwise noted. Subject to revisions without prior notice. E. & O.E.

Mechanical

Dimensions: mm: 133H x 394W x 222D inches: 5.22H x 15.5W x 8.75D

Weight: 14kg/31lbs

Environmental

Operating Temp Range*: -40 to 74°C (-40 to 165°F)

Humidity: Up to 95% (non condensing)

Altitude (m/ft): Up to 3700 (12,000)**

Audible noise @ 25°C***: 45dBa @ 1 meter (39in)

MTBF (hours): 250K + as per Telcordia SR-332, 100% duty cycle, full load, @ 40°C

BTU/Hr:

Normal mode: 120VAC Model: 18Watts/61.42BTU/HR

230VAC Model: 30Watts/102.36BTU/HR

Backup mode: 120VAC Model: 187.56Watts/640BTU/HR 230VAC Model: 197.82Watts/675BTU/HR

*�120VAC module derates after 50°C (122°F). 230VAC module derates after 55°C (131°F) @220/230/240V.

Derates 1.4% per °C past listed temperature range until a maximum of 74°C, Refer to manual for non listed voltage settings.

**Derates 2°C per 300m (1000ft) above 1400m (4500ft) *** Measured at 25°C ambient temperature

Performance

Typical Output Voltage THD (resistive load):

120VAC Model: <3% 230VAC Model: <3.5%

Typical Efficiency* (resistive load):

120VAC Model: 98% 230VAC Model: 97%

Typical Transfer Time: <5ms

Load Crest Factor: 3:1 (load dependent)

Lightning/Surge Protection: ANSI/IEEE C62.41.2:2002, Criteria A & B

*At nominal AC Input, full load and at 25°C ambient temperature

Power Connector Options

120VAC Model

Input: Output:

Standard (0170024-001)

Terminal Block Terminal Block

Optional (0170024-002)

Terminal Block Terminal Block + Dual 5-15R

230VAC Model

Standard (0170024-101)

Terminal Block Terminal Block

Agency Compliance

Electrical Safety: UL 1778, CAN/CSA-C22.2 No. 107.3, EN 62040-1**

Marks:

EMC: CFR Title 47 FCC Part 15 – Class A, ICES-003 – Class A, EN 62040-2 – UPS Category C2**

RoHS: Yes

**Applies to 230VAC version only

FXM HP 1100 Rugged UPS Module

Electrical

120VAC Model

Battery:

String Voltage: 48VDC Battery Breaker Rating: 50A Maximum Charging Current: 15A

Input:

Nominal Voltage: 120VAC Voltage Range: 85 to 171VAC Frequency: 50Hz or 60Hz (Autodetect Frequency is the default configuration, can also be manually configured.) ±5% �Maximum Current: 15A (@ Nominal voltage and max battery charging current) AC Breaker Rating: 20A

Output:

Waveform: Pure sinewave Nominal Voltage: 120VAC Voltage Regulation: ±10% on line mode, ±2% on inverter mode Power at 50°C: 1100W/VA Frequency: Output frequency = Input frequency Frequency Tolerance, Backup Mode: ±0.3 Hz

230VAC Model

Battery:

String Voltage: 48VDC Battery Breaker Rating: 50A Maximum Charging Current: 15A

Input:

Nominal Voltage: 210/220/230/240VAC Voltage Range: 153 to 322VAC Frequency: Nominal: 50Hz or 60Hz (Autodetect Frequency is the default configuration, can also be manually configured.) ±5% Current: �8A (@ Nominal voltage and max battery charging current) Input Breaker Rating: 10A

Output:

Waveform: Pure sinewave Nominal voltage: 210/220/230/240VAC (same as input) Voltage regulation: ±10% on line mode, ±2% on inverter mode Power at 55°C: 1100 @220/230/240V Frequency: Output frequency = Input frequency Frequency Tolerance: Backup Mode: ±0.3 Hz

Communication Interface

Protocol:

SNMP: SNMP v3 via Ethernet. Compatible with subscription and discovery services TCP/IP: IPv4 or IPv6 Email: SMTP via Ethernet

Security: Password: 256-bit Encryption Secured Web Interface: SSL for HTTPS

Display: Full graphic LCD, 480x272 pixels, Resistive touch screen

Ports:

•2 x RJ45: Ethernet •1 x RJ11: Battery Temperature Compensation •1 x RJ12: for Alpha CAN devices •1 x USB-A: For upgrades or file management via a standard USB flash drive •1 x USB-Mini B: For soft shutdown using MegaTec protocol complaint client

Indicators:

•Solid Green: Line Mode, •Flashing Green: Inverter mode •Yellow/Amber: Minor alarms •Red: Major/Critical alarms

Dry Contacts: Programmable NO/NC (250VAC, 1A)*, 3 user inputs, ATS

Factory Default:

•C1: On Battery •C2, C3: Low Battery + No Line •C4: Load Shed Timer 1 •C5: Alarm •C6*: 48VDC @ 500mA •C7: User Inputs •S1: Self test •S2: User Input •S3: Shutdown(EPO) •C8: ATS (48VDC @ 10mA )

* C6 is factory configurable only

02/2021

#0480066-00 REV A