This document is a product catalog sheet for the Eberle Design Inc. (EDI) 2018ECL Enhanced Signal Monitor, designed for Type 170 / 2070 traffic signal controller systems. The catalog sheet is specifically associated with the California Department of Transportation (Caltrans), as evidenced by references to Caltrans TSCE Specifications and Transportation Electrical Equipment Specifications (TEES). The document provides detailed technical specifications for a signal monitoring device manufactured by EDI, located in Phoenix, Arizona, and is ISO 9001:2015 registered.

The 2018ECL Signal Monitor offers 18-channel monitoring capabilities with multiple model options including versions with EIA-232 and Ethernet ports, as well as Datakey programming variants. Key features include enhanced 210 monitoring functions, event logging with 100 record nonvolatile memory, full intersection display with Red, Yellow, and Green LEDs, true RMS voltage measurements, recurrent pulse detection, and LEDguard signal thresholding technology. The device is designed to increase cabinet fault coverage, provide diagnostic capabilities, and support communications with laptop PCs or remote traffic management centers through specialized software. The product is specifically engineered to meet Caltrans specifications and support modern traffic signal infrastructure requirements.

View the file

Other files

File Type Posted
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
1-ODOT_106_Group7_TF4200_Nema_TS2Type2_terminal_facilities.pdf PDF
1-ODOT_106_Group8_Item_8-02.pdf PDF
1-ODOT_106_Group9_AlphaCell_Testing_11_A05__Celltron_Tester.pdf PDF
106-26_spec_Bid_Doc..pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
1-ODOT_106_Group7_detector_racks_TS1.pdf PDF
1-ODOT_106_Group8_Item_8-01.pdf PDF
1-ODOT_106_Group9_Alpha_PBT.pdf PDF
1-ODOT_106_Group9_Alpha_UPS_Riser.pdf PDF
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Model 2018ECL Catalog Sheet – 082819 Designed, Manufactured and Tested in the United States of America ISO 9001:2015 Registered

INTRODUCING A NEW STANDARD OF SAFETY AND

DIAGNOSTIC CAPABILITIES IN TYPE 170 / 2070

ENHANCED SIGNAL MONITORS

The EDI model 2018ECL Signal Monitor is designed to upgrade the capabilities of the basic 210 monitor used in Type 170 / 179 Output Files. The unit is fully compatible with the requirements of the 170, 179, and 2070 Controller Units and offers eighteen channels of monitoring. The 2018ECL Signal Monitor utilizes enhanced monitoring functions to increase cabinet fault coverage, providing additional assurance that cabinet equipment malfunctions will be detected and diagnosed properly.

Model Options:

2018ECL 18 channel capability with EIA-232 Port 2018ECLip 18 channel capability with Ethernet Port 2018KCL Datakey Programming with EIA-232 Port 2018KCLip Datakey Programming with Ethernet Port

2018ECL FEATURES

Enhanced 210 Monitoring Functions:

The 2018ECL meets all requirements of the Caltrans "TSCE Specifications 1/89" and Caltrans Transportation Electrical Equipment Specifications (TEES) of March 2009. Basic fault coverage includes Conflict, 24Vdc, and CU Watchdog monitoring. Red Monitoring senses the absence of signals on a channel. Dual Indication Monitoring detects simultaneous active signals on a channel. Clearance Monitoring ensures sequencing of signals with a proper minimum yellow clearance interval. AC Line Monitoring detects and responds to low AC Line voltages as well as interruptions with a minimum flash interval.

Event Logging:

The 2018ECL monitor maintains a 100 record nonvolatile event log which contains records of fault events showing the complete intersection status as well as AC Line events, configuration changes, monitor resets, cabinet temperature and true RMS voltages. A real time clock time stamps each log event with time and date.

RYG Full Intersection Display: The Full Intersection display uses Red, Yellow, and Green LEDs to show active colors of all channel inputs simultaneously for real-time intersection status.

EDI RMS-Engine: A DSP coprocessor converts ac input measurements to True RMS voltages, virtually eliminating false sensing due to changes in frequency, phase, or sine wave distortion.

Recurrent Pulse Detection: Recurrent Pulse Detection works in conjunction with the RMS-Engine to detect faults that are pulsing or intermittent in nature.

LEDguard®: This EDI innovative signal thresholding technique is used to increase the level of monitoring protection when using LED based signal heads.

Communications to Laptop PC or Remote Traffic Management Center:

An EIA-232 or optional Ethernet port provides access by a local PC or remote TMC running ECcom Windows based software for status, event log review, and archival.

Signal Sequence History Display: Five Signal Sequence History logs stored in nonvolatile memory each graphically display 30 seconds of signal status prior to each fault event. The resulting display eases diagnosing of intermittent and transient faults by viewing the exact signal states that the monitor sensed.

Configuration Monitor: Detects unintended and potentially unsafe programming changes and Red cable problems.

Flashing Yellow Arrow PPLT: Three operational modes are built-in for support of the MUTCD Flashing Yellow Arrow PPLT operation depending on the number of load switches in the cabinet.