This document is a detailed engineering drawing for an Extended R Cabinet for UPS, created by MoboTrex, a mobility and traffic engineering company located in Austin, TX. The technical drawing (ELS1027) provides a comprehensive schematic for a cabinet design, including multiple detailed views, component annotations, and assembly instructions. The drawing was initially released on 6/14 and underwent a revision on 9/17 involving a switch shield component replacement.

The technical drawing specifies a complex cabinet assembly with numerous components, including multiple quantity requirements for various parts (e.g., QTY 22 for some items, QTY 4 for others). The document includes specific installation notes, such as installing item 43 inside seams top and bottom, and provides scale references and detailed views of different cabinet sections. While the document does not explicitly outline contract terms, it appears to be a technical specification for a specialized cabinet design potentially intended for infrastructure or utility applications, with precise manufacturing tolerances and detailed component layout.

View the file

Other files

File Type Posted
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
1-ODOT_106_Group7_TF4200_Nema_TS2Type2_terminal_facilities.pdf PDF
1-ODOT_106_Group8_Item_8-02.pdf PDF
1-ODOT_106_Group9_AlphaCell_Testing_11_A05__Celltron_Tester.pdf PDF
106-26_spec_Bid_Doc..pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
1-ODOT_106_Group7_detector_racks_TS1.pdf PDF
1-ODOT_106_Group8_Item_8-01.pdf PDF
1-ODOT_106_Group9_Alpha_PBT.pdf PDF
1-ODOT_106_Group9_Alpha_UPS_Riser.pdf PDF
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG TITLEDES ENGR

CHECKED BY

DRAWN

MATERIAL & FINISH

SIZE

D DWG No REV

PROE

ANGLES = 0.5

X.XXX = 0.020

X.XX = 0.030

OTHERWISE SPECIFIED

TOLERANCES UNLESS

UNITS = INCHES

HOLE = .005

109 WEST 55TH STREET

DAVENPORT, IA 52806

PHONE: (563) 323-0009

REV ECN DESCRIPTION

REVISIONS

DATE CHKDDRAFT

WWW.MOBOTREX.COM

301 W. HOWARD LN., STE.200

AUSTIN, TX 78753

PHONE: (512) 521-3060

The information contained herein is the proprietary property of MoboTrex, Inc., and is disclosed with the understanding it will be retained in confidence and will neither be duplicated nor copied in whole or part nor be used for any purpose other than that for which disclosed.

MOBILITY & TRAFFIC EXPERTS

TM

71.12

REF

58.98

REF 26.38

REF

EXTENDED R CABINET, UPS

ELS1027

SEE BOM

JKA 6/14

BP 6/14

JKA 6/14

1 20237 INITIAL RELEASE JKA 6/14 BP

2 21810 SWITCH SHIELD FFD16802-001 REPLACED WITH F4029 DSH 9/17 BLP

SHEET 1 OF 1

SEE DETAIL D

NOTES:

1. INSTALL ITEM 43, INSIDE SEAMS TOP & BOTTOM.

SCALE 0.100

SEE DETAIL A

4 QTY 2

QTY 22

QTY 22

QTY 4

SCALE 0.120

SEE DETAIL B

SEE DETAIL C

REMOVED TO SHOW

ITEMS 5, 6, & 7.

QTY 10

QTY 22

QTY 22

20QTY 4

QTY 4

QTY 3

39QTY 2

DETAIL D

(22) PLACES

SCALE 0.300

SCALE 0.300

(2) PLACES

DETAIL A

11 35

36 37

SCALE 0.300

DETAIL B

13 14

15 QTY 7

23 INSTALL ITEM 23 BEHIND

ITEM 14

SCALE 0.300

DETAIL C

ssours Text Box provide a battery compartment that will accommodate (1) 13 1/2" (minimum) deep standard shelf and (2) roll out shelves with a 13-1/2" useable depth to accommodate two batteries each. (The batteries are 13-1/2" deep x 6-3/4" wide and weigh 73 LBs each