1-ODOT_106_Group7_TF5000_Nema_TS2Type1_terminal_facilities.pdf

PDF 540 KB Posted

Attached to
Competitive Selection OH|DOT10626-1
Contract number
DOT10626-1
Issued by
Ohio

About this file

The document is a product specification sheet for the Eagle TF5000 Series Load Bay, a NEMA TS-2, Type 1 traffic control system component manufactured by Eagle Traffic Control Systems, a division of MoboTrex located in Davenport, IA and Austin, TX. The document appears to be associated with a government file potentially related to an Oregon Department of Transportation (ODOT) contract, as indicated by the file naming convention.

The TF5000 Series Load Bay is available in four configurations (4, 8, 12, and 16 load switch positions) with standard NEMA TS2, Type 1 controllers and MMU monitors. Key product features include hardwired design for easy maintenance, front panel programmable flash indication colors, and compatibility with most existing Eagle cabinets. The load bays can be installed in less than four hours, with models TF5016 and TF5116 requiring size 6 or larger cabinets. The specification sheet provides detailed technical specifications, including dimensions, switch positions, and flash relay positions for each model variant.

View the file

Other files

File Type Posted
1-ODOT_106_Group10_2018ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group10_2018KCLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11_MMU16E_TS2_monitor.pdf PDF
1-ODOT_106_Group11_MMU216LE_TS2_monitor.pdf PDF
1-ODOT_106_Group7_Cabinet-Power-Supply_CPS105.pdf PDF
1-ODOT_106_Group7_LMD622_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_5_M-EL702cabinet.pdf PDF
1-ODOT_106_Group7_Size_6_P-EL712_cabinet.pdf PDF
1-ODOT_106_Group9_Cabinet_Transfer_XTV__Battery_Accessories__Alpha.pdf PDF
1-ODOT_106_Group11_SSM6LE_SSM12LE_Nema_6_and_12_ch_monitors.pdf PDF
1-ODOT_106_Group13Queue_Cutter_loop_amp_U-1400.pdf PDF
1-ODOT_106_Group13_Riotech_CTC_RRPE_Interface.pdf PDF
1-ODOT_106_Group1__2_2070E_2070_ATC_Controller_Yunex_.pdf PDF
1-ODOT_106_Group2__BLADE_Controller__Yunex.pdf PDF
1-ODOT_106_Group3_332L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group4_Base_Riser_336.pdf PDF
1-ODOT_106_Group5_SHA-1250_EDCO_NEMA_332_plug_in.pdf PDF
1-ODOT_106_Group7_LMD301_loop_amp.pdf PDF
1-ODOT_106_Group7_LMD622T_loop_amp.pdf PDF
1-ODOT_106_Group7_Size_6_SUPER_P_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_SUPER_R__cabinet.pdf PDF
1-ODOT_106_Group7__12VDC_Panel_Mount_Flasher_Control_for_Solar_ELTEC_FS5.pdf PDF
1-ODOT_106_Group7__Flasher_Cube_Traffic_Sensor_25DF.pdf PDF
1-ODOT_106_Group7_biu700.pdf PDF
1-ODOT_106_Group7_detector_racks_TS1.pdf PDF
1-ODOT_106_Group8_Item_8-01.pdf PDF
1-ODOT_106_Group9_Alpha_PBT.pdf PDF
1-ODOT_106_Group9_Alpha_UPS_Riser.pdf PDF
1-2025_signed_Affirmation_and_Disclosure.pdf PDF
1-ODOT_106_Group10_DataKey_Programmer__MonitorKey_EDI.pdf PDF
1-ODOT_106_Group17_Time_Sync-GPS.pdf PDF
1-ODOT_106_Group2__6__M60_ATC_NEMA_Yunex.pdf PDF
1-ODOT_106_Group4_336L-Wired-Cabinet.pdf PDF
1-ODOT_106_Group5_206L_power_supply.pdf PDF
1-ODOT_106_Group5_LMD222_Loop_Amp.pdf PDF
1-ODOT_106_Group5_Traffic_Sensor_Corporation_-_Load_Switches.pdf PDF
1-ODOT_106_Group7_Size_5_stretchwide_M36-EL704_cabinet.pdf PDF
1-ODOT_106_Group7_Size_7_EL720_cabinet.pdf PDF
1-ODOT_106_Group8_Item_8-03.pdf PDF
1-ODOT_106_Group9_Alpha_FXM1100HP_Inverter.pdf PDF
1-ODOT_106_Group9_Mini_Battery_Backup_System.pdf PDF
1-106-26_pricing__ITS_Controllers__Cabinets__Monitors__Detection__Accessory_Equipment__Probe_Data__and_Software_Due_5.15.25.xlsx XLSX spreadsheet
1-ODOT_106_Group10_2010ECLip_Catalog_Sheet.pdf PDF
1-ODOT_106_Group11NSM3E_Nema_3_ch_monitor.pdf PDF
1-ODOT_106_Group15_Mitchell_Technology_578.pdf PDF
1-ODOT_106_Group18Conflict_Monitor__Recertification.pdf PDF
1-ODOT_106_Group3_Base_Riser_332.pdf PDF
1-ODOT_106_Group5_EDI_242_isolator.pdf PDF
1-ODOT_106_Group5_PDC_252_isolator.pdf PDF
1-ODOT_106_Group5_SHA1210_EDCO_332.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TF5000 Series Load Bay NEMA TS-2, Type 1

Description

Eagle Traffic Control Systems continues our 80+ year history of providing excellence in the ever evolving traffic industry. All of Eagle’s prod-ucts are developed with the highest standards of engineering and manufacturing. Eagle maintains a superior level of integrity in interactions with all of our business partners and customers. We also take tremen-dous pride in being model corporate citizens.

Eagle load bays are available in dedicated four, eight, twelve, and sixteen load switch configurations.

The TF5000 series load bays are hardwired for ease of maintenance and economical modification.

The flash indication colors can be programmed from the front panel, using only a screwdriver.

The load bays will fit into most existing Eagle cabinets and can be installed in less than four

(4) hours.

Note: The TF5016 and TF5116 loadbays will only fit in size 6 or larger cabinets.

Part Number TF5004 TF5008 TF5012/TF5112** TF5016/TF5116**

Controller NEMA TS2, Type 1 NEMA TS2, Type 1 NEMA TS2, Type 1 NEMA TS2, Type 1

Monitor MMU MMU MMU MMU

Load Switch Positions 4 8 12 16

Flash Realy Positions 2 4 6 8

NEMA-2 Circuit Flasher 1 1 1 1

Dimensions

18.5”H x

19.25”W x 28.25”W

* The TF5112 and TF5116 use 10-32 screw connector field terminal connections.

Eagle TF5115 Load bay

Eagle Traffic Control Systems is a division of:

109 W. 55th Street • Davenport, IA • 52806 301 W. Howard Lane, Suite 200 • Austin, TX • 78753MoboTrex.com

File details come from the government source that posted it. Updated .