1-Cover Page Holladay City Hall VESTIBULE PERMIT (1) (1).pdf
PDF 2 MB Posted
- Solicitation number
- NS26-52
- Issued by
- Salt Lake County, Hildale City, Utah
About this file
This document is a permit document set for the Holladay City Hall Remodel, involving Holladay Municipal Corporation located at 4580 S. 2300 E. in Holladay, Utah. The project consists of a vestibule addition to the south of the existing City Hall, with revised parking and landscaping at the south end of the building. The permit documents are dated 10.20.2025 and include comprehensive drawing sets covering civil, landscape, architectural, structural, mechanical, plumbing, and electrical plans. The project involves multiple professional consultants, including Process Studio PLLC as the architect, Talisman Civil Consultants as the civil engineer, and several other specialized engineering firms.
The project site is located in a residential area, as shown in the vicinity map, and involves significant site modifications including a new vestibule, revised parking layout, new retaining and landscaping areas, and a new dumpster enclosure. Existing parking areas will be resurfaced according to civil drawings. The comprehensive drawing set (labeled GI002) provides a detailed overview of the project, including a full drawing list with multiple sheets covering every aspect of the renovation. The documents are prepared with professional specifications and include general contractor notes, emphasizing precise architectural and engineering requirements for the municipal building renovation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING CITY
HALL ENTRANCE
N
EXISTING CITY HALL
NEW VESTIBULE
ADDITION
REVISED PARKING LAYOUT
NEW RETAINING AND
LANDSCAPING AREAS
REVISED PARKING LAYOUT &
CURB CUT / ENTRY
NEW DUMPSTER
ENCLOSURE
EXISTING PARKING AREA,
TO BE RESURFACED PER
CIVIL DRAWINGS.
EXISTING PARKING AREA,
TO BE RESURFACED PER
CIVIL DRAWINGS.
Scale
Project Number
Date
Drawn by
Checked by
3055 s. grace street salt lake city, utah 84109 p.801.906.0866 www.processpllc.com
AL
L
ID
EA
S, D
ES
IG
N S, A R
R
AN
G
EM
EN
TS
, A N
D P
LA
N
S
IN
D
IC
AT
ED
O R
R
EP
R
ES
EN
TE
D
IN
T H
IS
D
R
AW
IN
G
A R
E O
W N
ED
B
Y
AN
D T
H E
PO
PE
R
TY
O F
PR
O
C
ES
S
ST
U D
IO
P
LL
C
A N
D W
ER
E
C R
EA
TE
D , E
VO
LV
ED
, A
N D
D
EV
EL
O
PE
D
F O
R U
SE
O
N A
N D
IN
C
O N
N
EC
TI
O
N W
IT
H
T H
IS
S
PE
C
IF
IE
D P
R O
JE
C
T.
N
O N
E O
F
TH
E
ID
EA
S, D
ES
IG
N
S, A
R R
AN
G
EM
EN
TS
, O
R P
LA
N
S
SH
AL
L
BE
U
SE
D
B Y
O R
D
IS
C
LO
SE
D
T O
A N
Y
PE
R
SO
N , F
IR
M
, O R
C O
R
PO
R
AT
IO
N
F O
R A
N Y
PU
R
PO
SE
W H
AT
SO
EV
ER
W
IT
H O
U T
W R
IT
TE
N C
O N
SE
N
T O
F
PR
O C
ES
S
ST
U
D
IO
P
LL
C
W R
IT
TE
N D
IM
EN
SI
O
N S
SH
AL
L H
AV
E
PR
EC
ED
EN
C E
O
VE
R S
C
AL
E D
IM
EN
SI
O
N S.
C O
N
TR
AC
TO
R S
SH
AL
L
VE
R
IF
Y
AN
D B
E R
ES
PO
N
SI
BL
E
FO
R
A
LL
D
IM
EN
SI
O N
S
AN
D C
O N
D
IT
IO
N
S O
N T
H E
JO
B
AN
D
T H
IS
O
FF
IC
E
BE
N O
TI
FI
ED
O
F
AN
Y
VA
R
IA
TI
O
N F
R O
M T
H E
D
IM
EN
SI
O N
S
AN
D C
O N
D
IT
IO
N
S
SH
O W
N B
Y
TH
ES
E
D R
AW
IN
G S.
W
AR
N
IN
G :R
EP
R
O D
U C
TI
O
N H
ER
EO
F
IS
A C
R
IM
IN
AL
O
FF
EN
SE
U
N
AU
TH
O
R
IZ
ED
D
IS
C
LO
SU
R E
M
AY
C O
N
ST
IT
U
TE
T
R
AD
E
SE
C R
ET
M
IS
AP
PR
O
PR
IA
TI
O
N
IN
V
IO
LA
TI
O N
O F
LA
W
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
CIVIL ENGINEER
TALISMAN CIVIL CONSULTANTS, LLC
1588 SOUTH MAIN STREET
SALT LAKE CITY, UTAH 84115
PHONE: 801.743.1300
CONTACT: ANDREW MORAN
EMAIL: andrewm@talismancivil.com
Project Status
STRUCTURAL ENGINEER
WCA STRUCTURAL ENGINEERING
442 NORTH MAIN STREET, SUITE 200
BOUNTIFUL, UT 84010
PHONE: 801-298-1118
CONTACT: CLIFF COLE
EMAIL: cliff.cole@wcaeng.com
MECHANICAL/ELECTRICAL/PLUMBING ENGINEER
ROYAL ENGINEERING
5005 SOUTH 900 EAST
MURRAY, UTAH 84117
PHONE: 801-375-2228
CONTACT: MARK MAKIN / CALVIN BARLOW
EMAIL: mark.makin@royaleng.com calvin.barlow@royaleng.com
LANDSCAPE ARCHITECT
G. BROWN DESIGN INC
678 EAST VINE STREET, SUITE 10
MURRAY, UTAH 84107
PHONE: 801-575-6066
CONTACT: ELIZABETH BEST
EMAIL: lbest@gbrowndesign.com
GEOTECHNICAL ENGINEER
GORDON GEOTECHNICAL ENGINEERING, INC
4426 SOUTH CENTURY DRIVE, SUITE 100
SALT LAKE CITY, UTAH 84123
PHONE: 801-327-9600
CONTACT: PATRICK EMERY
EMAIL: pat@gordongeotech.com
OWNERS:
10.20.2025
12" = 1'-0"
-1 0-
2:
:4
GI002
COVER SHEET - VESTIBULE
ADDITION
22-0044
HOLLADAY CITY
HALL REMODEL
10.20.2025
MDB
DJY
PERMIT DOCUMENTS
HOLLADAY CITY HALL REMODEL
4580 S. 2300 E. HOLLADAY, UT 84117
HOLLADAY MUNICIPAL CORPORATION
PERMIT DOCUMENTS | 10.20.2025
PROJECT INFORMATION:
DRAWING LIST:
VICINITY MAP:
PROJECT OVERVIEW:
PROJECT SITE
GENERAL CONTRACTOR NOTES:
4580 S 2300 E, HOLLADAY, UT 84117
HOLLADAY MUNICIPAL CORPORATION (C/O JARED BUNCH)
TBD
PROCESS STUDIO PLLC
TALISMAN CIVIL CONSULTANTS
GORDON GEOTECHNICAL ENGINEERING
G. BROWN ASSOCIATES
WCA STRUCTURAL ENGINEERING
ROYAL ENGINEERING
VESTIBULE ADDITION TO SOUTH OF EXISTING CITY HALL,
WITH REVISED PARKING AND LANDSCAPING AT SOUTH END
OF BUILDING.
*THIS DRAWING SET TO BE USED IN CONJUNCTION WITH
PRIMARY DRAWING SET ISSUED ON SAME DATE.
PROJECT ADDRESS:
PROJECT OWNER:
GENERAL CONTRACTOR:
ARCHITECT:
CIVIL ENGINEER:
GEOTECHNICAL ENGINEER:
LANDSCAPE ARCHITECT:
STRUCTURAL ENGINEER:
MEP ENGINEER:
PROJECT DESCRIPTION:
E
AS
T
4500 SOUTH
4500 SOUTH
HOLLADAY
BLVDMURRAY
HOLLADAY
ROAD
MURRAY
HOLLADAY
ROAD
SHEET # SHEET NAME
GENERAL
GI002 COVER SHEET - VESTIBULE ADDITION
CIVIL
C100 SITE PLAN
C200 GRADING PLAN
C700 DETAILS
C701 DETAILS
LANDSCAPE
LP-001 OVERALL PLANTING PLAN
LP-101 PLANTING PLAN
LP-501 PLANTING DETAILS
LI-101 IRRIGATION PLAN
LI-501 IRRIGATION DETAILS
LI-502 IRRIGATION DETAILS
ARCHITECTURAL
AE010 CODE ANALYSIS - VESTIBULE ADDITION
AS110 DEMOLITION SITE PLAN - VESTIBULE ADDITION
AS111 ARCHITECTURAL SITE PLAN - VESTIBULE ADDITION
AD110 DEMOLITION PLAN - VESTIBULE ADDITION
AE110 FLOOR PLANS - VESTIBULE ADDITION
AE111 FLOOR PLANS - VESTIBULE ADDITION
AE130 REFLECTED CEILING PLANS - VESTIBULE ADDITION
AE150 FINISH PLANS - VESTIBULE ADDITION
AE210 EXTERIOR VIEWS - VESTIBULE ADDITION
AE211 EXTERIOR ELEVATIONS - VESTIBULE ADDITION
AE310 BUILDING SECTIONS - VESTIBULE ADDITION
AE420 ENLARGED STAIR PLANS - VESTIBULE ADDITION
AE510 DETAILS - VESTIBULE ADDITION
AE511 DETAILS - VESTIBULE ADDITION
AE512 DETAILS - VESTIBULE ADDITION
AE513 DETAILS - VESTIBULE ADDITION
AE610 SCHEDULES & ASSEMBLIES - VESTIBULE ADDITION
STRUCTURAL
S2.0. FRAMING PLANS
S5.0. DETAILS
S5.1. DETAILS
S5.2. DETAILS
MECHANICAL
M001. MECHANICAL NOTES & LEGENDS
M403 MECHANICAL PLANS ADD/ALT SCOPE
M501. MECHANICAL DETAILS
M502. MECHANICAL DETAILS
M601. MECHANICAL SCHEDULES
PLUMBING
P001. PLUMBING NOTES & LEGENDS
P402 PLUMBING PLANS ADD/ALT SCOPE
P501. PLUMBING DETAILS
P601. PLUMBING DETAILS, SCHEDULES & SCHEMATICS
ELECTRICAL
E001. ELECTRICAL COVER SHEET
E002 ELECTRICAL SITE PLAN
E003 PHOTOMETRIC SITE PLAN
E401 ELECTRICAL PLANS ADD/ALT SCOPE
E501. ELECTRICAL DETAILS
E502 ELECTRICAL DETAILS
E601. ELECTRICAL SCHEDULES
E602. ELECTRICAL SCHEDULES
VESTIBULE
ADDITION SET
• THESE PERMIT DOCUMENTS, DATED 10.20.2025, SHALL BE SUBMITTED BY THE
GENERAL CONTRACTOR TO HOLLADAY CITY BUILDING DEPARTMENT FOR
REVIEW AND ISSUANCE OF BUILDING PERMIT. THIS DRAWING SET SUPERSEDES
ALL PREVIOUS DRAWING SETS ISSUED FOR THIS PROJECT. CONSTRUCTION
SHALL BE BASED ON THIS DRAWING SET ALONE.
• THE GENERAL CONTRACTOR SHALL REVIEW THE ENTIRE DRAWING SET AND
PARTICIPATE IN A PRE-CONSTRUCTION CONFERENCE INCLUDING THE
ARCHITECT AND ALL SUBCONTRACTORS PRIOR TO START OF CONSTRUCTION
ACTIVITIES. THE GENERAL CONTRACTOR SHALL PERFORM IN ACCORDANCE
WITH ALL GENERAL NOTES ON SHEET AE001
• THE GENERAL CONTRACTOR SHALL ABIDE BY THE UTAH DIVISION OF AIR
QUALITY REQUIREMENTS AND CONTACT THE UTAH DIVISION OF AIR QUALITY AT
(801) 536-4000.
• PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE GENERAL
CONTRACTOR WILL CONTACT BLUE STAKES AT (800) 662-4111 TO LOCATE
EXISTING IN-GROUND UTILITY LINE LOCATIONS.
• THE GENERAL CONTRACTOR SHALL NOT MAKE FIELD CHANGES TO THE
PROJECT DESIGN WITHOUT CONSULTATION AND APPROVAL BY BOTH THE
OWNER AND ARCHITECT-AND, WHEN REQUIRED, THE STRUCTURAL ENGINEER.
FAILURE TO DO SO MAY COMPROMISE THE PROJECT DESIGN'S CONFORMANCE
WITH BUILDING CODES, ENERGY CODES, OR STRUCTURAL INTEGRITY. THE
GENERAL CONTRACTOR WILL BEAR THE COST OF ANY CORRECTIONS TO
UNAUTHORIZED FIELD CHANGES.
• THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY
WITH ANY QUESTIONS OR REQUESTS FOR INFORMATION AS THEY ARISE, SO
TIMELY RESPONSES CAN BE PROVIDED AND CONSTRUCTION DELAYS AVOIDED.
CONTACT: DWIGHT YEE (607-379-3209, DWIGHT@PROCESSPLLC.COM). DO NOT
CONTACT THE STRUCTURAL ENGINEER DIRECTLY.
• THE GENERAL CONTRACTOR SHALL PROVIDE GUARANTEE OF ALL WORK ON
THE PROJECT TO THE OWNERS FOR A MINIMUM OF 1 YEAR FROM THE DATE OF
SUBSTANTIAL COMPLETION. THE GENERAL CONTRACTOR WILL PROVIDE
WRITTEN WARRANTIES FROM ALL PRODUCT, MATERIAL, AND SYSTEM
MANUFACTURERS FOR ITEMS INSTALLED ON THE PROJECT TO THE OWNERS.
• THE GENERAL CONTRACTOR WILL PROVIDE THE FOLLOWING SUBMITTALS FOR
OWNER AND ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING OR
INSTALLATION:
WINDOW SHOP DRAWINGS & PRODUCT DATA (SEE WINDOW SCHEDULE &
NOTES ON SHEET AE601)
EXTERIOR DOOR SHOP DRAWINGS & PRODUCT DATA (SEE DOOR SCHEDULE
& NOTES ON SHEET AE601)
BUILT-IN CASEWORK SHOP DRAWINGS
METAL FABRICATION AND SHOP DRAWINGS
STRUCTURAL STEEL FRAMING
RAILING AND GUARDRAIL SHOP DRAWINGS
SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL, ELECTRICAL AND
PLUMBING WORK. THE GENERAL CONTRACTOR WILL DIRECT SUBCONTRACTORS
TO APPLY FOR PERMITS ONCE THE BUILDING PERMIT HAS BEEN ISSUED.
No. Description Date
File details come from the government source that posted it. Updated .