This is Addendum #2 to the original plans and specifications for the Alcona Community Schools Elementary School and Sugar Shack re-roofing project located at 51 North Barlow Street in Lincoln, Michigan. The addendum, issued on March 20, 2019, by R.S. Scott Associates, Inc., modifies the fascia profile design to simplify the custom bend requirements. The primary revision allows the angle hemmed detail for the fascia to be omitted, provided the upper outer fascia features a bend that covers the top of the bottom inner fascia. The project encompasses new metal roofing components including glass fiber-asphalt shingles, synthetic underlayment, metal drip edges, recessed crown mold, and PAC-CLAD (PAC-850) vented metal soffit panels in medium bronze color. The addendum includes detailed drawings at scales of 3/4" = 1'-0" and 1/4" = 1'-0" referencing multiple sections (A, D, and sheet designations A5, A7, A8, and A9A) showing proposed eave and soffit details at various building locations including the gym and library.
The revision clarifies construction methodology for fascia installation across different building sections, allowing contractors flexibility in field execution while maintaining design integrity. All work shall remain in accordance with the original plans and specifications except as specifically modified by this addendum. The document includes standard architect/engineer liability disclaimers stating that any changes made without written approval of the architect/engineer shall not be the responsibility of the architect/engineer, and the responsible party shall defend and indemnify the architect/engineer from resulting liability. All dimensions are to be field verified by the contractor during installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R. S. Scott Associates, Inc. Alcona Community Schools Alpena, Michigan Elementary School and Sugar Shack Reroofing
(989) 354-3178 tel Lincoln, Michigan
(989) 354-3191 fax E-mail: edwardss@rsscott.com
March 20, 2019 RSSA Project Number 1-2159-10
ADDENDUM #2
This addendum is issued for the purpose of modifying and/or clarifying the original plans and specifications and shall take precedence over them.
All work herein shall be in accordance with the original plans and specifications except as specifically noted herein.
This addendum is being distributed by R.S. Scott Associated, Inc.
1. REVISION AND CLARIFICATION OF FASCIA PROFILE
The fascia profile has been modified to simplify the custom bend. The angle hemmed detail for the fascia may be omitted provided the upper (outer) fascia has a bend that covers the top of the bottom (inner) fascia.
SEE SK2 ATTACHED
(TOTAL PAGES 2)
AutoCAD SHX Text
SK2
AutoCAD SHX Text
ADDENDUM 2 REVISED FASCIA DETAILS
AutoCAD SHX Text W.O. 1-2159-10
AutoCAD SHX Text
(989) 354-3178
AutoCAD SHX Text
ALPENA, MICHIGAN 49707
AutoCAD SHX Text
405 RIVER STREET
AutoCAD SHX Text
SURVEYING
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
R. S. SCOTT ASSOCIATES, INC.
AutoCAD SHX Text
SPE
AutoCAD SHX Text 2/19
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHK:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SPE/EG
AutoCAD SHX Text 2/19
AutoCAD SHX Text ANY CHANGE, INCLUDING ALTERATION, MODIFICATION, ADDITION, DELETION OR DEVIATION BY THE OWNER, CONTRACTOR, AutoCAD SHX Text SUB-CONTRACTOR OR ANY OTHER PARTY OF ANY OF THE CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, THE
AutoCAD SHX Text PLANS AND SPECIFICATIONS AS SUBMITTED BY THE ARCHITECT/ENGINEER, SHALL NOT BE BINDING UPON OR CONSIDERED
AutoCAD SHX Text TO BE THE WORK OF THE ARCHITECT/ENGINEER. ANY SUCH CHANGE BY THE OWNER, CONTRACTOR, SUB-CONTRACTOR OR
AutoCAD SHX Text ANY OTHER PARTY, WITHOUT THE WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER SHALL NOT BE THE RESPONSIBILITY
AutoCAD SHX Text OF THE ARCHITECT/ENGINEER. THE PARTY WHO MADE THE CHANGE SHALL DEFEND, INDEMNIFY AND HOLD HARMLESS THE
AutoCAD SHX Text
ARCHITECT/ENGINEER FROM ANY AND ALL LIABILITY RESULTING FROM SUCH CHANGE.
AutoCAD SHX Text
CHANGES TO PLANS AND SPECIFICATIONS
AutoCAD SHX Text THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT/ENGINEER AND ARE NOT TO BE REUSED OR REPRODUCED WITHOUT HIS WRITTEN PERMISSION. THIS DRAWING IS COPYWRITTEN
AutoCAD SHX Text
ISSUE DATE
AutoCAD SHX Text
MARCH 1, 2019
AutoCAD SHX Text ALCONA COMMUNITY SCHOOLS ELEMENTARY SCHOOL & SUGAR SHACK RE-RE-ROOFING 51 NORTH BARLOW STREET LINCLON, MI 48742
AutoCAD SHX Text
DETAIL 2: PROPOSED EAVE & SOFFIT REFERENCE SECTION A SHEET A5
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"" = 1'-0"
AutoCAD SHX Text A5
AutoCAD SHX Text
AutoCAD SHX Text
NEW METAL DRIP EDGE
AutoCAD SHX Text
NEW METAL FASCIA . TOP PIECE TO BE HEMMED AND OVERLAP BOTTOM PIECE
AutoCAD SHX Text
NEW 1X6 AND 1X10 WOOD SUB-FASCIAS
AutoCAD SHX Text
NEW SYNTHETIC UNDERLAYMENT
AutoCAD SHX Text
NEW GLASS FIBRE-ASPHALT SHINGLES
AutoCAD SHX Text
CAULK
AutoCAD SHX Text
NEW RECESSED CROWN MOLD
AutoCAD SHX Text NEW PAC-CLAD (PAC-850) OR EQUAL, VENTED METAL SOFFIT PANELS & TRIM . COLOR: MEDIUM BRONZE
AutoCAD SHX Text
NEW RECESSED CROWN MOLD
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
NEW RECESSED CROWN MOLD TO RECIEVE SOFFIT)
AutoCAD SHX Text
EXISTING MASONRY WALLS TO REMAIN
AutoCAD SHX Text
EXISTING VERTICAL V-GROOVE METAL SIDING AND TRIM TO REMAIN
AutoCAD SHX Text
NEW METAL DRIP EDGE
AutoCAD SHX Text
EXISTING VERTICAL V-GROOVE METAL SIDING AND TRIM TO REMAIN
AutoCAD SHX Text
EXIST. PLYWD.
AutoCAD SHX Text
PROPOSED EAVE DETAIL AT GYM (REFERENCE SECTION D SHEET A7
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"" = 1'-0"
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text NEW PAC-CLAD (PAC-850) VENTED METAL SOFFIT PANELS & TRIM (OR EQUAL)(COLOR: MEDIUM BRONZE
AutoCAD SHX Text
NEW GLAS-FIBRE ASPHALT SHINGLES
AutoCAD SHX Text
NEW SYNTHETIC UNDERLAYMENT AND ICE & WATER SHIELD
AutoCAD SHX Text
NEW RECESSED CROWN MOLD TO RECIEVE SOFFIT)
AutoCAD SHX Text
NEW 1X4 AND 1X8 WOOD SUB-FASCIAS
AutoCAD SHX Text
FASCIA DETAIL
AutoCAD SHX Text
REVISED FASCIA DETAIL
AutoCAD SHX Text
NEW METAL DRIP EDGE
AutoCAD SHX Text
NEW METAL FASCIA. TOP PIECE TO BE HEMMED AND OVERLAP BOTTOM PIECE
AutoCAD SHX Text
NEW 1X6 AND 1X10 WOOD SUB-FASCIAS
AutoCAD SHX Text
CAULK
AutoCAD SHX Text
NEW RECESSED CROWN MOLD
AutoCAD SHX Text
PROPOSED EAVE DETAIL AT LIBRARY REFERENCE SECTION D SHEET A8
AutoCAD SHX Text A8
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"" = 1'-0"
AutoCAD SHX Text NEW PAC-CLAD (PAC-850) VENTED METAL SOFFIT PANELS & TRIM (OR EQUAL) COLOR: MEDIUM BRONZE
AutoCAD SHX Text
NEW RECESSED CROWN MOLD
AutoCAD SHX Text
FASCIA DETAIL
AutoCAD SHX Text
REVISED FASCIA DETAIL
AutoCAD SHX Text
FASCIA DETAIL
AutoCAD SHX Text
REVISED FASCIA DETAIL
AutoCAD SHX Text DETAIL 1:PROPOSED DETAIL @ GABLE END (GYM) REFERNCE DETAIL 1 SHEET A9AREFERNCE DETAIL 1 SHEET A9A
AutoCAD SHX Text
SCALE:1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A9a
AutoCAD SHX Text
EXISTING WOOD BLOCKING &LOOKOUTS TO REMAIN
AutoCAD SHX Text
EXISTING WOOD BLOCKING &LOOKOUTS TO REMAIN
AutoCAD SHX Text NEW 8" (VIF) METAL FASCIA OVER NEW 1X8 WOOD SUB-FASCIA. (LOWER EDGE TO BE TURNED DOWN OVER VERTICAL SIDING & HEMMED)
AutoCAD SHX Text
CAULK
AutoCAD SHX Text
EXIST. VERTICAL METAL SIDING & TRIM OVER PLYWD. TO REMAIN
AutoCAD SHX Text NEW PAC-CLAD (PAC-850) VENTED METAL SOFFIT PANELS & TRIM (OR EQUAL) COLOR: MEDIUM BRONZE
AutoCAD SHX Text
NEW RECESS CROWN MOLD
AutoCAD SHX Text
EXIST. VERTICAL METAL SIDING & TRIM OVER PLYWD. TO REMAIN
AutoCAD SHX Text
NEW SHINGLES OVER NEW SYN. UNDERLAYMENT OVER EXIST. SHEATHING
AutoCAD SHX Text
NEW METAL DRIP EDGE
AutoCAD SHX Text
FASCIA DETAIL
AutoCAD SHX Text
REVISED FASCIA DETAIL
AutoCAD SHX Text
ISSUED 3/20/19
AutoCAD SHX Text NOTE: REVISED FASCIA DETAIL: WHERE THE ORIHGINAL DETAIL SHOWS AN ANGLE HEMMED EDGE AT THE STEPPED FSCIS AND SINGLE FASCIAS, THE GEM AND ANGLE MAY BE OMITTED AND IN ITS PLACE A STRAIGHT BEND THAT WIL OVERLAP THE INNER STEP OF THE FASCIA. ALL DIMENSIONS SHALL BE FIELD VERIFIED.