08_71_00_-_Door_Hardware.pdf

PDF 179 KB Posted

Attached to
Public Works Administration Building Window Replacement
Solicitation number
Y25-757
Issued by
Orange County, Orlando City, Florida

About this file

This document is a technical specification section (08710) for Door Hardware for the Orange County Public Works Administration Building, detailing comprehensive requirements for door hardware installation. The specification covers commercial door hardware for swinging doors, including hinges, locks, exit devices, closers, thresholds, and weatherstripping, with a focus on meeting Florida Product Approval standards and compliance with various building and safety codes. The document provides detailed requirements for manufacturers, materials, installation methods, and performance standards, with specific emphasis on hurricane-rated components, accessibility requirements, and system integration.

The specification mandates strict quality control, including BHMA Grade 1 standards for hardware, Florida-specific product approvals, and comprehensive warranty provisions (three years for most components, with five-year warranties for specific items like electromagnetic locks and exit devices). Manufacturers must provide detailed submittal documentation, including product data, shop drawings, and certification of fire-rated hardware. The specification also requires coordination with electrical systems, access control, and security systems, and includes specific requirements for keying systems, with all lock cylinders to be furnished in Schlage restricted keyways and coordinated with the Owner's existing master key system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORANGE COUNTY 2023.10.06

PUBLIC WORKS ADMINISTRATION BUILDING SPECIFICATIONS

DOOR HARDWARE 08710 - 1

SECTION 08710 - DOOR HARDWARE

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary

Conditions and Division 01 Specification Sections, apply to this Section.

B. Note all pressures on the all drawings, architectural, structural or otherwise as well as specifications. All hardware must meet the pressures indicated tested within the door, within the wall system, as a whole, not individually. If systems do not meet as expected notify the design team immediately during bidding.

1.2 SUMMARY

A. This Section includes the following:

1. Commercial door hardware for the following:

a. Swinging doors.

b. Other doors to the extent indicated.

2. Cylinders for doors specified in other Sections.

3. Electrified door hardware.

4. Adding hardware to new doors as indicated in architectural documents.

B. Related Sections include the following:

1. Division 08 Section "Aluminum Frames" for door silencers provided as part of frames.

2. Division 08 Section "Aluminum-Framed Entrances and Storefronts" for entrance door hardware, except cylinders.

3. Division 08 Section "All-Glass Entrances and Storefronts" for door hardware.

4. Division 26 Sections for connections to electrical power system and for low-voltage wiring work.

5. Division 28 Section "Access Control" for access control devices installed at door openings and provided as part of a security access system.

6. Division 28 Section "Intrusion Detection" for detection devices installed at door openings and provided as part of an intrusion detection system.

7. Division 28 Section "Fire Detection and Alarm" for connections to building fire alarm system.

1.3 SUBMITTALS

A. Product Data

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 2

1. Catalog Cuts: Each hardware item.

2. Manufacturer's parts lists, templates, and installation instructions.

3. Florida product approval of entire system, wall, door, hardware, locks etc.

B. Shop Drawings

1. Hardware Schedule: Submit schedule based on hardware indicated, organize sets into schedule using same door numbers and hardware sets indicated on drawing and specifica-tions. Indicate locations and mounting heights of each type of hardware.

2. Each door number shown on drawings shall be easily and readily identifiable as to its hardware.

3. Templates: After hardware schedule has been reviewed, submit immediately to door manufacturer and millwork supplier of wood doors templates for finish hardware needed to prepare doors and frames.

4. Ship hardware prepaid to door manufacturer and millwork supplier.

5. Keying Schedule: Include keying information in schedule.

6. Wiring Diagrams: Submit wiring diagrams of electrically operated or electrical control items specified herein.

7. Submit copies of product approval in accordance with Division 1, General requirements for each exterior openings. Evidence of product approval are (Miami-Dade County or Florida State “Notice of Acceptance.”) Where acceptable by AHJ, furnish a signed sealed Engineer’s Evaluation by a registered Florida Engineer in lieu of “Notice of Ac-ceptance.”

C. Quality Control Submittals: Certificates: Manufacturer's certificate that fire rated hardware meets or exceeds specified requirements.

D. Contract Closeout Submittals

1. Instruction sheets for locks, door closers, panic hardware.

2. Special hardware items such as wrenches.

3. Include data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.

1.4 QUALITY ASSURANCE

A. Installer Qualifications: An employer of workers trained and approved by lock manufacturer.

1. Installer's responsibilities include supplying and installing door hardware and providing a qualified Architectural Hardware Consultant available during the course of the Work to consult with Contractor, Architect, and Owner about door hardware and keying.

2. Installer shall have warehousing facilities in Project's vicinity.

3. Scheduling Responsibility: Preparation of door hardware and keying schedules.

B. Required to generate submittals: Architectural Hardware Consultant Qualifications: A person who is currently certified by DHI as an Architectural Hardware Consultant and who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 3

1. Electrified Door Hardware Consultant Qualifications: A qualified Architectural

Hardware Consultant who is experienced in providing consulting services for electrified door hardware installations.

C. Source Limitations: Obtain each type and variety of door hardware from a single manufacturer, unless otherwise indicated.

1. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction are acceptable.

D. Fire-Rated Door Assemblies: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to NFPA 252.

1. Test Pressure: After 5 minutes into the test, neutral pressure level in furnace shall be established at 40 inches (1016 mm) or less above the sill.

E. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use.

F. Preinstallation Conference: Upon return of the reviewed finish hardware schedule, arrange for a keying meeting with Architect and Owner, hardware supplier, and other involved parties to ensure locksets are functionally correct and keying fulfills project requirements

1. As soon as possible after the keying conference, typed copies of the keying schedule shall be furnished to Owner's Representative.

2. After review, keying schedule will be returned to factory representative so that perma-nent cores and keys can be prepared on a timely basis.

3. Masterkey system shall be a factory registered system to ensure the propriety of the codes and avoid duplication or crosskeying.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Packing and Shipping: Package each item of hardware and each lockset separately in individual boxes, complete with necessary screws, instructions and installation template for spotting mortising tools.

1. Mark each box with item number corresponding to number in Hardware Schedule.

2. Protect hardware from theft by cataloging and storing in secure area.

3. Deliver permanent keys and interchangeable cores to Owner by security shipment di-rect from lock manufacturer or hardware supplier.

1.6 COORDINATION

A. Templates: Distribute door hardware templates for doors, frames, and other work specified to be factory prepared for installing door hardware. Check Shop Drawings of other work to

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 4

confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

B. Electrical System Roughing-in: Coordinate layout and installation of electrified door hardware with connections to access control system.

1.7 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Structural failures including excessive deflection, cracking, or breakage.

b. Faulty operation of operators and door hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering and use.

2. Warranty Period: Three years from date of Substantial Completion, except as follows:

a. Electromagnetic Locks: Five years from date of Substantial Completion.

b. Exit Devices: Five years from date of Substantial Completion.

c. Manual Closers: Five years from date of Substantial Completion.

1.8 MAINTENANCE SERVICE

A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

PART 2 - PRODUCTS

2.1 MATERIALS AND FABRICATION

A. General: Contract hardware shall fit doors, frames, and hardware as detailed or required herein.

1. Furnish hardware with template and with machine and wood screws as required for use with frames and doors.

2. Include screws, concealed fasteners, brackets and accessories necessary for complete in-stallation.

3. Except for finish hardware specified under other Sections, sufficient quantities of finish hardware shall be furnished as required to complete project, even though not completely scheduled herein. Such items shall be of type and quality suitable to service and function required and comparable in quality to adjacent hardware.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 5

2.2 HINGES, BUTTS, AND PIVOTS

A. Provide ball bearing butt hinges for doors:

1. With closers

2. With spring hinges

3. That are labeled doors

4. With 2 pair butts or greater

5. That are main entrances

B. Provide plain bearing hinges for other doors.

C. Provide one hinge for each 2'-6" of door height or fraction thereof.

D. Provide 4.5 by 4.5 inch hinges unless size of door or cladding requires a different size.

E. Provide brushed stainless steel hinges throughout.

F. All hinges shall have non-removeable pins

G. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. YKK Branded Hinges provided they meet the specification above.

2. Hager Companies (HAG).

3. Stanley Commercial Hardware; Div. of The Stanley Works (STH).

4. Accepted Equal

2.3 LOCK CYLINDERS AND KEYING

A. Cylinder Grade: BHMA Grade 1. Coordinate Cylinders and Keying selection with Owner Representative prior to preparing new hardware schedule. New cylinder and keying must work with existing building hardware.

B. Cylinders/Cores: Manufacturer's standard tumbler type, constructed from brass or bronze, stainless steel, or nickel silver :

1. All lock cylinders shall be furnished in Schlage restricted keyway H01 through H08. The Public Works Locksmith shall designate which keyway will be provided for each project.

2. All lock systems shall be operated by the following unless otherwise directed:

a. New or existing master key as determined by Public Works

b. Grand master or Great grand master key as determined by Public Works

3. Cores shall be removable for use by manufacturer’s cylinder only.

4. Lock systems shall for access-controlled doors shall have a mechanical key override that shall only be operated by the master key, grand master key or great grand master key.

C. Construction Keying: Comply with the following:

1. Construction Master Keys: Provide cylinders with feature that permits voiding of con-struction keys without cylinder removal. Provide 10 construction master keys.

1. Construction Cores: Provide construction cores that are replaceable by permanent cores.

2. a. Replace construction cores with permanent cores, as directed by Owner.

b. Furnish permanent cores to Owner for installation.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 6

D. Permanent Keying System: Unless otherwise indicated, provide a factory-registered keying system complying with the following requirements:

1. Existing System: Great grand master key locks to Owner's existing system.

2. Keying: As directed by Public Works. Key all cylinders to the same change key.

a. Cylinders shall be master keyed.

E. Keys: Provide Schlage nickel-silver keys complying with the following:

1. Stamping: Permanently inscribe each key with a visual key control number and include the following notation:

a. Notation: "DO NOT DUPLICATE."

2. Quantity: In addition to one extra blank key for each lock, provide the following:

a. Cylinder Change Keys: Three.

b. Master Keys: Five.

c. Grand Master Keys: Five.

d. Great-Grand Master Keys: Five

2.4 LOCKS, LATCHES, AND BOLTS

A. Bored Type Locksets And Latchsets

1. Provide lever hardware that will prevent sagging or unlatching of door in normal use or in fire conditions.

2. Provide curved lip strikes unless otherwise specified.

3. Schlage Heavy Duty Hurricane Rated Series

4. Lock strike-ASA with curved lip and protective box.

5. Trim design basis: Schlage Tubular ND-Series lever handle with a wrought rose.

6. Provide two piece mechanical anti-friction latch bolt.

B. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Corbin & Russwin

2. Sargent

3. Schlage (design basis)

4. Best

5. Any required to meet Florida Product Approval of system that is not listed above.

C. Mortise Locks and Latches: Schlage (basis of design) Best Access Systems, Corbin Russ-win, or Sargent.

1. Levers shall be cast or solid metal. All internal working parts shall be brass, bronze, steel or stainless steel. Furnish wrought steel mortar guards with all strikes.

2. Locks and latches shall be equal to Schlage L9000 Series with 06A trim.

a. Furnish knurling or abrasive coating to lever on corridor side of door to all doors leading to hazardous areas (e.g. Mechanical Rooms, Electrical Rooms, Elevator Ma-chine Rooms, etc.).

3. Electrical Modifications:

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 7

a. Locks indicated to be electrified shall be factory modified to electrically lock or elec-trically unlock, as indicated, upon receipt of a 24V signal and will remain in this mode until signal is interrupted.

b. Locks indicated to have REX (request-to-exit) switches shall incorporate internal SPDT contacts for remote signaling of operation of the inside lever handle. Switches shall be used in conjunction with the specified monitor switches and the security con-trol system to accommodate "authorized egress".

c. Field-connect all electrified locks to associated power transfer units.

d. Coordinate electrical connection and installation with Division 17.

C. Flush Bolts

1. Provide one pair manual flush bolts on inactive leaf of each pair of unlabeled doors ex-cept on pairs of doors with vertical rod exit devices.

2. Provide one pair manual flush bolts on inactive leaf of each pair of labeled doors that ser-vice normally unoccupied spaces (storage, mechanical).

3. Provide automatic flush bolts on inactive leaf of each pair of labeled doors except on pairs of doors with vertical rod exit devices.

4. Provide dustproof strike for flush bolts except where threshold is provided.

D. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Glynn-Johnson

2. Ives

3. Baldwin

4. Cipco

5. Rockwood

6. Hager

7. Any required to meet Florida Product Approval of system that is not listed above.

2.5 EXIT DEVICES

A. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Precision Hardware Inc. (PHI)

2. Sargent

3. Von Duprin Series 98

4. Falcon Series 1491 (design basis, Required on Exterior Doors to meet NOA)

5. Any required to meet Florida Product Approval of system that is not listed above.

B. Standard: BHMA A156.3, Grade 1. Note some doors are wider than the standard 36” door. New exit devices shall match the width of the door.

C. Certified Products: Provide exit devices listed in BHMA's "Directory of Certified Exit De-vices."

D. Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to au-thorities having jurisdiction, for panic protection, based on testing according to UL 305. Meet all pressures required and listed in the Florida Product Approval.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 8

E. Fire Exit Devices: Complying with NFPA 80 that are listed and labeled by a testing and in-specting agency acceptable to authorities having jurisdiction, for fire and panic protection, based on testing according to UL 305 and NFPA 252.

F. Outside Trim: Lever with cylinder; material and finish to match locksets, unless otherwise indicated.

1. Match design for locksets and latchsets, unless otherwise indicated.

H. Through Bolts: For exit devices and trim on non-fire-rated wood doors.

L. Concealed Vertical Rod Exit Devices: Comply with the following:

1. Actuating Bar: Push pad.

2. Material: Stainless steel.

3. Meet all pressures required and listed in the Florida Product Approval.

N Remote Door Release Button: Comply with the following:

1. Mini Station Control: Schlage Series 660

2. Meet all pressures required and listed in the Florida Product Approval.

2.6 PUSH/PULL UNITS

A. Push & Pull Plates

1. Anodized Black to match Door and Curtainwall system.

2. 4" x 16" size

3. Bevel edges

4. Hidden fasteners

B. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Cipco

2. Brookline

3. Baldwin

4. Hiawatha

5. Rockwood

6. Hager

7. Any required to meet Florida Product Approval of system that is not listed above.

C. Push/Pulls for Aluminum Storefront Entrance (FALCON 9970).

a. Any required to meet Florida Product Approval of system that is not listed above.

2.7 CLOSERS AND DOOR CONTROL UNITS

A. Standard: ANSI A156.4, Grade 1. Provide Manufacturer’s 10 year warranty.

B. Provide standard and parallel arms as required to prevent use of brackets wherever possible.

Provide heavy duty arms for exterior doors with hydraulic backcheck closers to eliminate spindle stress.

1. Provide one closer on pair of non-rated doors with manual flush bolts. All closers to be timed with coordinator.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 9

C. Method of mounting as determined by opening conditions. Coordinate with wood door manufacturer to provide wood screw closer mounting into solid wood head rail of non fire label doors in lieu of through bolting. Through bolting is required for fire labeled doors.

Where through bolts are required, provide bolt heads to match finish of closer cover.

1. Provide parallel arm mount for outswing exterior doors and for other interior doors as required to suit project conditions. In general, provide parallel arm mounting to avoid having closers mounted along the public side of corridors or spaces.

D. Size as determined by frequency of usage, exterior or interior, door size and weight.

E. Include brackets for mounting in opening where required.

F. Provide closer model numbers as required to conform to handicap accessibility standards and to provide a maximum opening force of 8.5 lbf for exterior doors and 5.0 lbf for interior doors.

1. Exception: Provide a minimum opening force of 15 lbf for labeled doors as required by

NFPA.

G Provide special rust inhibitive coating on closers subjected to high moisture or humidity areas of exposure, including without limitation, exterior locations, air plenums and penthouse.

H. Provide brushed aluminum covers throughout. Color match to door.

I. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. LCN (design basis)

2. Sargent

3. Yale

4. Norton

5. Corbin & Russwin

6. Dorma

7. Any required to meet Florida Product Approval of system that is not listed above.

J. Door Stops

1. Provide one wall stop or floor stop for each door leaf except as otherwise scheduled to have overhead stop or cushion stop closer.

2. Anodized Black to match Door and Curtainwall system.

3. Floor stop: Ives-436 - (include risers for carpeted areas)

4. Floor stop (Non-carpeted areas): Ives-438

5. Wall Bumper: Ives-401, 402 and 403 as appropriate

6. Overhead stops: GJ100A series by Glynn Johnson.

7. Any required to meet Florida Product Approval of system that is not listed above.

K. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Glynn-Johnson

2. Ives (design basis)

3. Cipco

4. Corbin

5. Rockwood

6. Hager

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 10

7. Any required to meet Florida Product Approval of system that is not listed above.

L. Coordinators: Glynn-Johnson COR Series; lever and trigger mechanism with 1-5/8 inch wide by 5/8 inch high aluminum channel; UL Listed; ANSI 156.3 - Or any required to meet Florida Product Approval of system that is not listed above.

M. Drop Down Door Holders: Commercial grade 5” minimum drop down door holder. Color match. Do not install drop downs on rated doors.

N. Automatic Door Bottoms: Provide integrated mortised automatic door bottoms at all doors, regardless of their material. ADB must be part of tested system. If ADP is not in tested sys-tem. Provide surface mounted ADB, color matched, heavy duty, with double bulbs, manufac-turer to match the submitted door hardware supplier.

2.10 THRESHOLDS, WEATHERSTRIPPING AND SEALS

A. Thresholds, Rain Drips and Weatherstripping

1. Provide threshold at each exterior door.

2. Thresholds shall be handicap accessible and listed as such.

3. Extruded aluminum thresholds.

4. Jamb and head seals: Extruded aluminum retainer, neoprene sponge gaskets, finish to match door and frames.

5. Sill weatherstripping: Surface mounted extruded aluminum retainer, neoprene sponge gaskets, finish to match door.

6. At UL labeled doors provide UL rated gaskets.

7. Rain Drips: Zero 142.

8. Thresholds must be part of the tested system and provide all trims and extensions to cover adjacent flooring for flush and true finish.

B. Manufacturers: Subject to compliance with requirements provide products from one of the following:

1. Zero

2. Pemco

3. Reese

4. National Guard.

5. Hager

6. Any required to meet Florida Product Approval of system that is not listed above.

C. Door Gasketing, General: Provide continuous mechanically fastened weather-strip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indi-cated or scheduled. Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.

1. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.

2. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.

3. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.

1. Automatic Surface Mounted Door Bottom Requirements:

a. Heavyduty double bulb seal – Color match door.

b. Florida Product Approved System.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 11

2. Automatic Surface Mounted Door Bottom Manufacturers: Subject to compliance with requirements provide products from one of the following:

a. Zero International 361AA-36 (BOD)

b. Pemco

c. Reese

d. National Guard.

e. Hager

D. Air Leakage: Not to exceed 0.50 cfm per foot (0.000774 cu. m/s per m) of crack length for gasketing other than for smoke control, as tested according to ASTM E 283.

E. Smoke-Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and la-beled by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke-control ratings indicated, based on testing according to UL 1784.

1. Provide smoke-labeled gasketing on 20-minute-rated doors and on smoke-labeled doors.

F. Fire-Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to UL 10B or NFPA 252.

G. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting agency, for sound ratings indicated, based on testing according to ASTM E 1408.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verify that doors and frames are ready to receive work and dimensions are as indicated on shop drawings. Verify that power supply is available to power operated devices.

Beginning of installation means acceptance of existing conditions.

3.2 INSTALLATION

A. Coordinate work of this Section with other directly affected Sections involving manufacture of internal reinforcement for door hardware.

B. Install finish hardware in accordance with final hardware schedule and in accordance with manufacturer's specifications and instructions.

C. Wherever cutting and fitting is required to install hardware onto or into surfaces which are later to be painted or finished in another way, install each item completely and then remove and store in secure place during finish application. After completion of finishes, reinstall each item. Do not install surface mounted items until finishes have been completed on sub-strate.

D. Install locks during normal period of construction without permanent cylinders.

E. Temporary cylinders shall be used as required to prevent unauthorized access to building dur-ing construction.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 12

F. When directed, and in presence of Owner or authorized representative, install permanent cyl-inders.

G. Owner's Representative will verify function of locksets and cylinders.

H. Set thresholds in bed of sealant on inner and outer edges.

I. Shim thresholds as required to properly fit under door.

J. Locate finish hardware as follows:

1. Top butt hinge: 9" from top of door

2. Intermediate butt hinge(s): Equidistant spacing from top and bottom hinges

3. Bottom butt hinge: 10" above finish floor

4. Conform to ANSI A117.1 for positioning requirements for handicapped.

5. Conform to NFPA requirements for hardware in fire rated doors.

K. Flushbolts: Provide pair of automatic flushbolts for inactive leaf of pair of doors except as otherwise scheduled to be manual flushbolts.

1. Provide dustproof strike at sill except where threshold is provided.

3.3 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

1. Spring Hinges: Adjust to achieve positive latching when door is allowed to close freely from an open position of 30 degrees.

2. Electric Strikes: Adjust horizontal and vertical alignment of keeper to properly engage lock bolt.

3. Door Closers: Unless otherwise required by authorities having jurisdiction, adjust sweep period so that, from an open position of 70 degrees, the door will take at least

3 seconds to move to a point 3 inches (75 mm) from the latch, measured to the leading edge of the door.

3.4 CLEANING AND PROTECTION

A. Clean adjacent surfaces soiled by door hardware installation.

B. Clean operating items as necessary to restore proper function and finish.

C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion.

ORANGE COUNTY 2023.10.06

DOOR HARDWARE 08710 - 13

3.5 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes. Refer to

Division 01 Section "Demonstration and Training."

3.6 DOOR HARDWARE SETS

A. See Drawings for Hardware sets, coordinate with mandatory parts that apply to all sets.

END OF SECTION 087100