The provided document is a set of engineering drawings for the Former Salzburg Cleaners Remediation project located at 1906 South Erie Street in Bay City, Michigan. The project involves environmental site remediation and is being managed by SME (an engineering firm), with drawings dated May 8, 2019. The drawings include a comprehensive set of technical plans covering property location, demolition, soil boring analytical results, stratigraphic cross-sections, excavation plans, and site restoration details.
The drawings reveal significant environmental contamination at the site, with multiple soil borings showing high concentrations of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) above the Part 201 Generic Residential Cleanup Criteria. The remediation plan includes complete demolition of an existing building, excavation to depths ranging from 5' to 15', removal of site pavements, utility decommissioning, and careful soil removal. The restoration plan involves backfilling with MDOT Class II sand, 21AA dense graded aggregate, and topsoil, with specific compaction requirements. The project appears to be addressing historical contamination from what was likely a dry cleaning facility, with precise environmental cleanup and site restoration objectives.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bidding and Contract Document (R 2/19) Project Name: Former Salzburg Cleaners File No. 761/18283.SAR
DRAWINGS
FORMER SALZBURG CLEANERS REMEDIATION
BAY CITY, MICHIGAN
BAY
LOCATION MAP
SCALE: 1" = 80'
NOT TO SCALE
COUNTY MAP
LIST OF DRAWINGS
FIGURE No. SHEET TITLE
Property Location Cover Sheet
Demolition Plan
Soil Boring Analytical Results
Stratigraphic Cross Section A - A'
Stratigraphic Cross Section B - B'
Excavation Plan
Site Restoration Plan
COUNTY
AREA OF
WORK
CADD
Scale
Project
No.
Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
S
H E
E T
C
O V
R
S
H E
E T d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
Project
Project Location
Sheet Name www.sme-usa.com
BAY CITY, MI ph: 989.684.6050
P L
O
D
A T
E
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
PROPERTY LOCATION
COVER SHEET
5/8/19
CRP
CRP
AS NOTED
079308.00
NOTE: SATELLITE IMAGE TAKEN FROM GOOGLE EARTH PRO IMAGERY DATED JUNE 23, 2016
AutoCAD SHX Text
NORTH
GASGASGAS
D
O H
O H
OH
O H
O H
O H
O H
O H
O
H
X
X
X
X
X
X
X
X
O
H
O
H
X
N O
R T
H
LEGEND
APPROXIMATE PROPERTY
BOUNDARY
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
P
F F I G r e c o v e r d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I L
C A
T I O
N
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
DEMOLITION
PLAN
5/8/19
JR/CRP
CRP
1" = 25'
079308.00
0'
GRAPHIC SCALE: 1" = 25'
25' 50'
ABOVE GROUND
STORAGE TANK
NOTES:
1. INSTALL 6 FT. HIGH SECURITY FENCE AROUND THE WORK PERIMETER
PRIOR TO COMMENCEMENT OF ANY WORK.
2. CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO PROTECT ABOVE
AND BELOW GROUND UTILITIES, EXISTING SIDEWALKS, EXISTING SITE
FEATURES, AND ADJACENT PROPERTY AND STRUCTURES. ALL UTILITY
LOCATIONS ARE APPROXIMATE. THE CONTRACTOR SHALL UTILIZE THE
MISS DIG SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO
COMMENCEMENT OF ANY WORK.
3. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS TO COMPLETE
THE PROJECT SCOPE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND
LOCAL REGULATIONS.
4. CONTRACTOR SHALL DECOMMISSION, CUT, AND CAP ALL UTILITIES
ASSOCIATED WITH THE EXISTING BUILDING AT THE EXCAVATION LIMITS
SHOWN ON FIGURE 6 PRIOR TO BUILDING DEMOLITION.
5. CONTRACTOR SHALL PROPERLY ABATE, DEMOLISH, AND COMPLETELY
REMOVE THE EXISTING BUILDING, FOUNDATIONS, AND SITE
PAVEMENTS.
6. ALL HAZARDOUS MATERIALS SHALL BE ABATED IN ACCORDANCE WITH
PROJECT SPECIFICATIONS.
7. CONCRETE AND HMA MATERIALS SHALL BE DISPOSED OF AT A
LICENSED DISPOSAL OR RECYCLING FACILITY.
8. FOUNDATIONS OUTSIDE OF THE EXCAVATION AREA SHALL BE
COMPLETELY REMOVED.
9. CONTRACTOR SHALL DISPOSE OF THE AST AT A LICENSED DISPOSAL
OR RECYCLING FACILITY.
10. DRAWING INFORMATION TAKEN FROM THE MDEQ RRD GPR ANOMALY
MAP DATED MAY 2016, GOOGLE EARTH PRO IMAGERY DATED JUNE 23,
2016, AND SITE RECONNAISSANCE.
EXISTING BUILDING
(TO BE DEMOLISHED)
EXISTING
RESIDENTIAL
BUILDING
HMA PARKING LOT
WATER MAIN
STORM SEWER
PORTLAND CEMENT CONCRETE
STORM DRAIN
SEWER MANHOLE
D
BURIED CABLE
OVERHEAD UTILITY
OH
GAS
VALVE
UNKNOWN
VERTICAL PIPES
S O
U T
H
E
R I
R
E E
T
GRASS
HMA PARKING LOT
CABLE BOX
WATER
VALVE
X
UNKNOWN UNDERGROUND
UTILITIES
UTILITY POLE
BENCHMARK
EL: 100'
SANITARY SEWER
CONTRACTOR SUPPLIED 6
FEET TALL SECURITY FENCE
CABLE BOX
HURON &
EASTERN
RAILROAD
PROPERTY
GAS
GAS
ADJACENT PROPERTY
BOUNDARY
RESIDENTIAL
PROPERTY
CITY OF BAY
CITY PROPERTY
AJ BAILEYS BAR
PROPERTY
MODEL IMAGE
SALON PROPERTY
STORM DRAIN AND
ASSOCIATED PIPE TO BE
REMOVED AND CAPPED
AT EXCAVATION LIMITS.
GASGAS
EXISTING BUILDING
(TO BE DEMOLISHED)
EXISTING
RESIDENTIAL
BUILDING
HMA PARKING LOT
GAS
VALVE
O H
O H
O H
O H
O H
O
H
O
H
O
H
O
H
O
H
SB9
GRASS
HMA PARKING LOT
SB8
SB3
CABLE BOX
CABLE BOX
WATER
VALVE
SB11
BENCHMARK
EL: 100'
D
X
X
X
X
X
X
X
CITY OF BAY
CITY PROPERTY
HURON &
EASTERN
RAILROAD
PROPERTY
AJ BAILEYS BAR
PROPERTY
MODEL IMAGE
SALON PROPERTY
RESIDENTIAL
PROPERTY
SB13
SB15
SB16
SB17
SB18
SB19
ABOVE GROUND
STORAGE TANK
UNKNOWN
VERTICAL PIPES
SB5
SB7
SB6
SB2
SB12
SB10
SB1
SB4
SB14
N O
R T
H
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
A
N
S
O I L
S
H E d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I
C A
T I O
N
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
SOIL SAMPLE
ANALYTICAL
RESULTS
5/8/19
CRP/JAB
CRP/ART
1" = 30'
079308.00
0'
GRAPHIC SCALE: 1" = 30'
30' 60'
NOTES:
1. CONCENTRATIONS REPORTED IN MICROGRAMS PER KILOGRAM ( g/kg).
2. <RLs = LESS THAN LABORATORY REPORTING LIMITS.
3. VOCs = VOLATILE ORGANIC COMPOUNDS
4. SVOCs = SEMIVOLATILE ORGANIC COMPOUNDS
5. PID = PHOTO IONIZATION DETECTOR. RESULTS REPORTED IN PARTS PER
MILLION (PPM).
6. DRAWING INFORMATION TAKEN FROM THE MDEQ RRD GPR ANOMALY
MAP DATED MAY 2016, GOOGLE EARTH PRO IMAGERY DATED JUNE 23,
2016, AND SITE RECONNAISSANCE.
A
S O
U T
H
E
R
R
E E
T
SB1
10-10-2018 ( 2'-3')
VOCs n-Butylbenzene 29,000 sec-Butylbenzene 7,800
Cyclohexane 34,000
Ethylbenzene 200,000
Isopropyl benzene 26,000 n-Propylbenzene 100,000
1,2,3-Trimethylbenzene 6,700
1,3,5-Trimethylbenzene 10,000
2,2,4-Trimethylpentane 43,000
Xylenes 18,000
SVOCs
2-Methylnaphthalene 160,000
Napthalene 150,000
10-10-2018 ( 3.5-4')
VOCs
Benzene 1,200 n-Butylbenzene 18,000 sec-Butylbenzene 5,600
Cyclohexane 34,000
Ethylbenzene 19,000
Hexane 56,000
Isopropyl benzene 11,000 n-Propylbenzene 47,000
1,2,3-Trimethylbenzene 2,200
1,2,4-Trimethylbenzene 4,900
1,3,5-Trimethylbenzene 1,400
2,2,4-Trimethylpentane 92,000
Xylenes 3,800
SVOCs
2-Methylnaphthalene 38,000
Napthalene 31,000
10-10-2018 (15.5'-16')
VOCs & SVOCs <RLs
SB5
10-10-2018 (0.5'-1')
VOCs n-Butylbenzene 31,000 sec-Butylbenzene 31,000
Isopropyl benzene 13,000 n-Propylbenzene 41,000
1,2,4-Trimethylbenzene 230,000
SVOCs
Napthalene 910
10-10-2018 (9'-9.5')
VOCs & SVOCs <GRCC
10-10-2018 (14.5'-15')
VOCs & SVOCs <GRCC
SB6
10-10-2018 (2'-2.5')
VOCs sec-Butylbenzene 68,000
Ethylbenzene 6,400
Isopropyl benzene 47,000 n-Propylbenzene 130,000
1,2,3-Trimethylbenzene 220,000
1,2,4-Trimethylbenzene 720,000
1,3,5-Trimethylbenzene 280,000
Xylenes 40,000
SVOCs
Napthalene 2,600
10-10-2018 (11'-11.5')
VOCs & SVOCs <RLs
10-10-2018 (14'-14.5')
VOCs & SVOCs <GRCC
SOIL BORING LOCATION
CHEMICAL CONSTITUENTS ABOVE
PART 201GENERIC RESIDENTIAL
CLEANUP CRITERIA (GRCC)
SOIL BORING LOCATION
CHEMICAL CONSTITUENTS BELOW
GRCC
LEGEND
ADJACENT PROPERTY
BOUNDARY
WATER MAIN
STORM SEWER
PORTLAND CEMENT CONCRETE
STORM DRAIN
SEWER MANHOLE
GAS
D
BURIED CABLE
OVERHEAD UTILITY
OH
GAS
X
UNKNOWN UNDERGROUND
UTILITIES
UTILITY POLE
SANITARY SEWER
A'
B
B'
APPROXIMATE EXTENT OF
CONTAMINATION
SB15
2-19-2019 (3'-3.5')
VOCs
1,2,4-Trimethylbenzene 1100
SVOCs <GRCC
ODORS NOTED AND PID
RESULTS OF 4.5-140 PPM FROM
4.5' TO 6'.
SB9
10-10-2018 (1'-1.5')
VOCs
1,2,4-Trimethylbenzene 640
SVOCs
Napthalene 2,100
10-10-2018 ( 2'-3')
VOCs sec-Butylbenzene 14,000
Ethylbenzene 5,500
Isopropyl benzene 8,000 n-Propylbenzene 18,000
1,2,3-Trimethylbenzene 61,000
1,2,4-Trimethylbenzene 110,000
1,3,5-Trimethylbenzene 34,000
Xylenes 34,000
SVOCs
2-Methylnaphthalene 5,900
Napthalene 9,700
10-10-2018 (14'-14.5')
VOCs & SVOCs <GRCC
APPROXIMATE PROPERTY
BOUNDARY
AutoCAD SHX Text µg/kg).
SB12-EL. 102.5
SB10-EL. 102.4
SB1-EL. 101.7
A
A'
EOB: EL. 87.5
SB7-EL. 101.9
<1
<1
EOB: EL. 87.4
EOB: EL. 85.7
<1
EOB: EL. 86.9
SB4-EL. 102.7
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
1.2
<1
1.6
<1
<1
<1
<1
NORTH
BUILDING
EDGE
EOB: EL. 87.7'
<1
1.3
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
SOUTH
BUILDING
EDGE
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
X
S E
C F I G r e c o v e r d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I
C A
T I O
N
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
STRATIGRAPHIC
CROSS SECTION
A - A'
5/8/19
JGR/CRP
CRP
AS NOTED
079308.00
HOT MIX ASPHALT (HMA) PAVEMENT
CROSS SECTION A - A'
SCALE: VERTICAL 1" = 4'
HORIZONTAL 1" = 12'
LEGEND
SAND OR CLAY FILL
LEAN, NATURAL CLAY
PORTLAND CEMENT CONCRETE
SOIL SAMPLE WITH CHEMICAL
CONSTITUENTS ABOVE GRCC
APPROXIMATE EXTENT OF
CONTAMINATION
SOIL SAMPLE WITH CHEMICAL
CONSTITUENTS BELOW GRCC
PHOTOIONIZATION DETECTOR
READING REPORTED IN PPM.
NOTES:
1. GRCC = PART 201 GENERIC RESIDENTIAL CLEANUP CRITERIA.
2. <RLs = LESS THAN REPORTING LIMITS.
3. PPM = PARTS PER MILLION
4. SOIL DESCRIPTIONS ARE INFERRED BETWEEN SOIL BORING LOCATIONS.
SAND
EOB: EL. 85.9
SB5-EL. 102.2
B'
SB2-EL. 100.9
B
SB7-EL. 101.9
EOB: EL. 87.2
EOB: EL. 86.9
EOB: EL. 86.9
SB6-EL. 101.9
WEST
BUILDING
EDGE
EAST
BUILDING
EDGE
<1
1.5
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
<1
4.8
<1
<1
<1
<1
<1
<1
SB14-EL. 103.4
<1
<1
<1
<1
<1
<1
<1
<1
<1
EOB: EL. 87.4
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
X
S E
C F I G r e c o v e r d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I
C A
T I O
N
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
STRATIGRAPHIC
CROSS SECTION
B - B'
5/8/19
JGR/CRP
CRP
AS NOTED
079308.00
CROSS SECTION B - B'
SCALE: VERTICAL 1" = 4'
HORIZONTAL 1" = 12'
NOTES:
1. GRCC = PART 201 GENERIC RESIDENTIAL CLEANUP CRITERIA.
2. <RLs = LESS THAN REPORTING LIMITS.
3. PPM = PARTS PER MILLION
4. SOIL DESCRIPTIONS ARE INFERRED BETWEEN SOIL BORING LOCATIONS.
LEGEND
SAND OR CLAY FILL
LEAN, NATURAL CLAY
PORTLAND CEMENT CONCRETE
SOIL SAMPLE WITH CHEMICAL
CONSTITUENTS ABOVE GRCC
APPROXIMATE EXTENT OF
CONTAMINATION
SOIL SAMPLE WITH CHEMICAL
CONSTITUENTS BELOW GRCC
TOPSOIL
PHOTOIONIZATION DETECTOR
READING REPORTED IN PPM.
H
O H
O H
OH
O H
O H
O H
O H
O H
O
H
X
X
X
X
X
X
O
H
O
H
X
D
X
X
SB8
SB3
SB11
SB14
SB17
SB18
SB19
SB4
SB5
SB7
SB6
SB2
SB12
SB9
SB15
SB16
SB10
SB1
N O
R T
H
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
S
H E
X C d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I
C A
T I O
N
M a y p m p l a c e
FORMER SALZBERG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
EXCAVATION
PLAN
5/8/19
CRP
CRP
1" = 20'
079308.00
0'
GRAPHIC SCALE: 1" = 20'
20' 40'
NOTES:
1. SLOPE EXCAVATION 1H : 1V
2. CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO PROTECT ABOVE
AND BELOW GROUND UTILITIES , EXISTING SIDEWALKS, EXISTING SITE
FEATURES, AND ADJACENT PROPERTY AND STRUCTURES. ALL UTILITY
LOCATIONS ARE APPROXIMATE.
3. THE CONTRACTOR SHALL UTILIZE THE MISS DIG SYSTEM TO LOCATE
ALL UNDERGROUND UTILITIES PRIOR TO THE COMMENCEMENT OF
ANY WORK.
4. UTILITIES ENCOUNTERED DURING EXCAVATION SHALL BE CUT AND
CAPPED AT THE EXCAVATION LIMITS.
5. ALL UTILITIES NOT TO BE CUT AND CAPPED SHALL BE PROTECTED
DURING EXCAVATION.
6. SAWCUT AND REMOVE HMA PAVEMENT 5 FEET NORTH OF THE NORTH
EXCAVATION LIMIT PRIOR TO EXCAVATION OPERATIONS. CONTRACTOR
SHALL TAKE PROPER PRECAUTIONS TO PROTECT THE REMAINING HMA
PAVEMENTS.
7. THE PROFESSIONAL SHALL PERFORM PERIMETER AIR MONITORING
UTILIZING A PHOTOIONIZATION DETECTOR (PID) TO SCREEN AMBIENT
AIR FOR VOLATILE ORGANIC COMPOUNDS (VOCs). THE CONTRACTOR
SHALL SUPPRESS SITE ODORS USING ODOR SUPPRESSING FOAM AS
DEEMED NECESSARY BY THE PROFESSIONAL.
8. DRAWING INFORMATION TAKEN FROM THE MDEQ RRD GPR ANOMALY
MAP DATED MAY 2016, GOOGLE EARTH PRO IMAGERY DATED JUNE 23,
2016, AND SITE RECONNAISSANCE.
BOTTOM OF EXCAVATION
ELEVATION: 97'
(DEPTH: 5')
EXISTING
RESIDENTIAL
BUILDING
GAS
VALVE
S O
U T
H
E
R
R
E E
T
HMA PARKING LOT
CABLE BOX
CABLE BOX
WATER
VALVE
BENCHMARK
EL: 100'
BOTTOM OF EXCAVATION
ELEVATION: 86.5'
(DEPTH: 15')
LEGEND
APPROXIMATE PROPERTY
BOUNDARY
WATER MAIN
STORM SEWER
STORM DRAIN
SEWER MANHOLE
GAS
D
BURIED CABLE
OVERHEAD UTILITY
OH
GAS
X
UNKNOWN UNDERGROUND
UTILITIES
UTILITY POLE
SANITARY SEWER
CONTRACTOR SUPPLIED 6
FEET TALL SECURITY FENCE
SOIL BORING LOCATION
CHEMICAL CONSTITUENTS ABOVE
PART 201GENERIC RESIDENTIAL
CLEANUP CRITERIA (GRCC)
SOIL BORING LOCATION
CHEMICAL CONSTITUENTS BELOW
GRCC
ADJACENT PROPERTY
BOUNDARY
CITY OF BAY CITY
PROPERTY
HURON & EASTERN
RAILROAD
PROPERTY
RESIDENTIAL
PROPERTY
HMA PARKING LOT
SAW CUT HMA (SEE NOTE 6)
H
O H
O H
OH
O H
O H
O H
O H
O H
O H
O
H
X
X
X
X
X
X
O
H
O
H
X
D
X
X
N O
R T
H
Project
Project Location
Sheet Name www.sme-usa.com
CADD
Scale
Project
No. Revision Date
Designer
Date
S m e i n c p z W
I P
C
A D
D
W G
S E n v r e v
S
H E
R
E S
T d w g
NO REPRODUCTION SHALL BE MADE WITHOUT THE PRIOR
CONSENT OF SME
c
DRAWING NOTE: SCALE DEPICTED IS MEANT FOR 11" X 17"
AND WILL SCALE INCORRECTLY IF PRINTED ON ANY
OTHER SIZE MEDIA
Figure No.
P L O
T
D
A T
E
F I
C A
T I O
N
M a y p m p l a c e
FORMER SALZBURG
CLEANERS
REMEDIATION
1906 SOUTH ERIE STREET
BAY CITY, MICHIGAN
RESTORATION
PLAN
5/8/19
CRP
CRP
1" = 20'
079308.00
0'
GRAPHIC SCALE: 1" = 20'
20' 40'
NOTES:
1. ANY DAMAGE OR DISTURBANCE TO PUBLIC AND/OR ADJACENT
PARCELS SHALL BE REPAIRED TO PRE CONSTRUCTION CONDITIONS AT
THE SOLE EXPENSE OF THE CONTRACTOR.
2. DRAWING INFORMATION TAKEN FROM THE MDEQ RRD GPR ANOMALY
MAP DATED MAY 2016, GOOGLE EARTH PRO IMAGERY DATED JUNE 23,
2016, AND SITE RECONNAISSANCE.
EXISTING BUILDING
GAS
VALVE
S O
U T
H
E
R
R
E E
T
HMA PARKING LOT
CABLE BOX
CABLE BOX
WATER
VALVE
BENCHMARK
EL: 100'
LEGEND
APPROXIMATE PROPERTY
BOUNDARY
WATER MAIN
STORM SEWER
STORM DRAIN
SEWER MANHOLE
GAS
D
BURIED CABLE
OVERHEAD UTILITY
OH
GAS
X
UNKNOWN UNDERGROUND
UTILITIES
UTILITY POLE
SANITARY SEWER
PORTLAND CEMENT
CONCRETE
GRASS
GRASS
HMA PARKING LOT
TYPICAL BACKFILL CROSS SECTION
6 INCHES OF MDOT 21AA
GRADED AGGREGATE
COMPACTED TO 95 % OF
THE MAXIMUM DRY DENSITY
AS DETERMINED BY THE
MODIFIED PROCTOR TEST
(ASTM D1557) OR 6 INCHES
OF TOPSOIL, SEEDED, AND
MULCHED.
MDOT CLASS II SAND OF
VARYING THICKNESS
COMPACTED TO
95 % OF THE MAXIMUM DRY
DENSITY AS DETERMINED BY
THE MODIFIED PROCTOR
TEST (ASTM D1557).
NATURAL CLAY
6 INCHES OF MDOT 21AA DENSE
GRADED AGGREGATE
EXISTING
RESIDENTIAL
BUILDING
CITY OF BAY CITY
PROPERTY
HURON & EASTERN
RAILROAD
PROPERTY
RESIDENTIAL
PROPERTY
ADJACENT PROPERTY
BOUNDARY
6 INCHES OF
TOPSOIL,
SEEDED, AND
MULCHED
NOT TO SCALE
| 79308.00 - Planset 582019.pdf |
| Sheets and Views |
| 1 |
| Insert from: "079308.00 - Fig 2 Demo.pdf" |
| Sheets and Views |
| 11x17 |
| Insert from: "079308.00 - Fig 3 Soil An.pdf" |
| Sheets and Views |
| FIG3 |
| Insert from: "079308.00 - Fig 4 A - A'.pdf" |
| Sheets and Views |
| 4 |
| Insert from: "079308.00 - Fig 5 B - B'.pdf" |
| Sheets and Views |
| 4.1 |
| Insert from: "079308.00 - Fig 6 Exc.pdf" |
| Sheets and Views |
| 11x17 |
| Insert from: "079308.00 - Fig 7 Rest.pdf" |
| Sheets and Views |
| 11x17 |
| Insert from: "079308.00 - Fig 2 Demo.pdf" |
| Sheets and Views |
| 11x17 |
| Insert from: "079308.00 - Fig 7 Rest.pdf" |
| Sheets and Views |
| 11x17 |
File details come from the government source that posted it. Updated .