About this file

The document appears to be a set of construction drawings for a parking garage at a Department of Veterans Affairs (VA) facility in New Orleans, Louisiana. The drawings show the typical layout for levels 3 through 6 of the garage, including details on partition types, rated walls, lighting, pipe guards, and other structural elements. This document is likely part of the technical specifications for a federal contract opportunity related to the construction or renovation of this parking garage facility. The associated federal contract opportunity has a Solicitation Number of 36C25624Q1205 and is seeking Architectural and Engineering (AE) services for a Parking Garage Assessment at the VA facility.

View the file

Other files

File Type Posted
S05 RFI Questions-Answers from COR 09-11-2024.docx DOCX document
36C25624Q1205 0001.docx DOCX document
0238-5AS102-L.pdf PDF
0213-4AS104-K.pdf PDF
0211-4AS102-K.pdf PDF
0216-4AS107-K.pdf PDF
0237-5AS101-L.pdf PDF
0243-5AS107-L.pdf PDF
0127-4SJ901.pdf PDF
0210-4AS101-K.pdf PDF
36C25624Q1205.docx DOCX document
Final SOW Employee Patient Parking Garage_01 02.docx DOCX document
0173-5SJ901.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

DN

UP

STP

STP

C

D

E

F

G

H

J

K

L

M

N

5A I41

5A

S10 4-L

00AI102-A6

6AI102-M3

AI

2-

A 6 5A

I4

RAMP

3.6

5" EJ

5AI401

E6

5AI402

F5

PARKING LEVEL 3 ELEV = 123'-4"

PARKING LEVEL 4 ELEV = 134'-0"

PARKING LEVEL 5 ELEV = 144'-8"

PARKING LEVEL 6 ELEV = 155'-4"

GARAGE CONNECTOR ELEVATIONS

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

5AS104-L

BLDG 5 TYPICAL PARKING LEVEL

(LEVELS 3 - 6)

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 5 LEVEL 4

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

6 ADDENDUM #6 - POST BID JANUARY 27, 2012

10 BULLETIN 011D MAY 31, 2013

File details come from the government source that posted it. Updated .