About this file

This document appears to be a set of construction drawings for parking level 2 of building 4 of a Department of Veterans Affairs medical center project in New Orleans, Louisiana. The drawings provide detailed floor plans, section views, and notes regarding the facility layout, construction materials, and building systems. Key details include:

The drawings show the overall layout of parking level 2, including the ramps, stairwells, columns, and sanitary systems. General notes cover partition types, rated walls, dimensions, pipe guards, lighting, and bollard details. The drawings reference related documents such as enlarged floor plans, electrical drawings, and structural details. There are indications of multiple addendums and bulletins that have been issued for this project.

This appears to be design documentation rather than a solicitation or contract document. There are no details provided regarding products/services required, response dates, pricing, set-asides, or other contracting information.

View the file

Other files

File Type Posted
S05 RFI Questions-Answers from COR 09-11-2024.docx DOCX document
36C25624Q1205 0001.docx DOCX document
0238-5AS102-L.pdf PDF
0213-4AS104-K.pdf PDF
0216-4AS107-K.pdf PDF
0240-5AS104-L.pdf PDF
0237-5AS101-L.pdf PDF
0243-5AS107-L.pdf PDF
0127-4SJ901.pdf PDF
0210-4AS101-K.pdf PDF
36C25624Q1205.docx DOCX document
Final SOW Employee Patient Parking Garage_01 02.docx DOCX document
0173-5SJ901.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U

DN

UP

PARKING

LEVEL 2 AT

EL 114'-8"

OPEN TO

CONCOURSE

LEVEL 1 AT

EL 100'-0"

STAIR

STK-1

STAIR

STK-2

STP

STP

5" EJ

4AI403

C3

4AI402

C3

N

M

L

K

J

H

G

F

E

D

C

SANITARY TANK -

SEE STRUC

4AS108-K

E3

4AS102K

4AI410

00AI101-A5

00AI101-A6

RAMP

1.4

3.6

W_1W_1W_1

OPP

OPP

APPROX. EXTENTS OF TRAFFIC BEARING

WATEPROOFING MEMBRANE; TYP. OF 2

LOCATIONS - SEE SPEC SECTION

07 18 16 FOR MORE INFORMATION

0AS507

C3

STANDING SEAM

MTL ROOF CANOPY

L540K F3

L540K F2

4AS108-K

B6

4AI401

B6

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4AS102-K

BLDG 4 OVERALL SECOND PARKING LEVEL

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 2

NO DIRECT CONNECTION FROM

PARKING LEVEL 2 TO CONCOURSE

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

10 BULLETIN 011D MAY 31, 2013

RFI-03259: Canopy Steel connection clarification.

File details come from the government source that posted it. Updated .