0238-5AS102-L.pdf
PDF 310 KB Posted
- Solicitation number
- 36C25624Q1205
About this file
This document appears to be a set of construction drawings for the Second Parking Level of Building 5 at the Veterans Affairs Medical Center in New Orleans, Louisiana. The drawings include detailed floor plans, section views, and notes providing general information about the project scope and specifications. Key details include:
The project involves the construction of a new parking garage with multiple levels. The drawings focus on the second level, providing a comprehensive layout with details on partition types, rated walls, lighting, pipe guards, and other construction elements. Enlarged plan views are referenced for additional details on medical equipment not shown in the main floor plans. The drawings also include notes on general construction requirements, such as dimensions, pipe guards for vehicular traffic, and lighting specifications. Overall, this appears to be a standard set of construction documents for a parking garage facility, providing the necessary technical details to support the execution of this project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S05 RFI Questions-Answers from COR 09-11-2024.docx | DOCX document | |
| 36C25624Q1205 0001.docx | DOCX document | |
| 0213-4AS104-K.pdf | ||
| 0211-4AS102-K.pdf | ||
| 0216-4AS107-K.pdf | ||
| 0240-5AS104-L.pdf | ||
| 0237-5AS101-L.pdf | ||
| 0243-5AS107-L.pdf | ||
| 0127-4SJ901.pdf | ||
| 0210-4AS101-K.pdf | ||
| 36C25624Q1205.docx | DOCX document | |
| Final SOW Employee Patient Parking Garage_01 02.docx | DOCX document | |
| 0173-5SJ901.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
PARKING
LEVEL 2
ELEV = 112'-8"
STP
STP
STAIR
STL-1
STAIR
STL-2
5AI401
D6
5AI402
C6
C
D
E
F
G
H
J
K
L
M
N
5A I41
5A
S10 2-L
00AI101-A6
6AI101-M3
AI
1-
A 6 5A
I4
00AI101-A6
6AI101-M3
AI
1-
A 6 5A
I4
RAMP
3.6
5" EJ
APPROX. EXTENTS OF TRAFFIC BEARING
WATEPROOFING MEMBRANE, TYP. OF 3
LOCATIONS - SEE SPEC SECTION 07 18 16
FOR MORE INFORMATION
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
5AS102-L
BLDG 5 OVERALL SECOND PARKING LEVEL
DV MAGJUNE 30, 2011
CONSTRUCTION DOCUMENTS 1
629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MAINTENANCE
EWP_04
SCALE: 1/16" = 1'-0"1 BLDG 5 LEVEL 2
1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION
SCHEDULE AND GENERAL PARTITION TYPE NOTES.
2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN
VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.
3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING
HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO
PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002
FOR MORE INFORMATION.
4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH
FACE.
5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT
EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.
6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING
LAYOUT.
7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502
FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504
FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH
WALLS
8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD
MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD
MOUNTING AT SOG
GENERAL FLOOR PLAN NOTES
NOTE: FIRE EXTINGUISHER CABINETS
HAVE BEEN REMOVED FROM EWP-04
2 ADDENDUM #2 JULY 29, 2011
4 ADDENDUM #4 AUGUST 5, 2011
6 ADDENDUM #6 - POST BID JANUARY 27, 2012
10 BULLETIN 011D MAY 31, 2013
File details come from the government source that posted it. Updated .