About this file

This document appears to be a set of construction drawings for parking levels 3 through 6 of a medical center building. The drawings provide detailed elevations, floor plans, and general notes for the design of the parking garage, including features such as stairs, elevators, ramps, and lighting. While this file does not directly address a federal contract opportunity, it is related to the solicitation "R425--AE STUDY Parking Garage Assessment Patient and Staff/Visitor(VA-24-00063255)" issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 16. The solicitation appears to be for an architectural and engineering study to assess the parking garage for the medical center. The document summarizes key details about the existing parking facility that would be relevant to the scope of work for the solicitation.

View the file

Other files

File Type Posted
S05 RFI Questions-Answers from COR 09-11-2024.docx DOCX document
36C25624Q1205 0001.docx DOCX document
0238-5AS102-L.pdf PDF
0211-4AS102-K.pdf PDF
0216-4AS107-K.pdf PDF
0240-5AS104-L.pdf PDF
0237-5AS101-L.pdf PDF
0243-5AS107-L.pdf PDF
0127-4SJ901.pdf PDF
0210-4AS101-K.pdf PDF
36C25624Q1205.docx DOCX document
Final SOW Employee Patient Parking Garage_01 02.docx DOCX document
0173-5SJ901.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP DN

PARKING LEVEL 3 ELEV = 127'-4" - NO DIRECT CONNECTION TO CONCOURSE

PARKING LEVEL 4 ELEV = 138'-0" - CONNECTION TO CONCOURSE LEVEL 3 @ 138'-0"

PARKING LEVEL 5 ELEV = 148'-8" - NO DIRECT CONNECTION TO CONCOURSE

PARKING LEVEL 6 ELEV = 159'-4" - CONNECTION TO CONCOURSE LEVEL 4 @ 157'-0"

STP

STP

STAIR

STK-2

STAIR

STK-1

5" EJ

N

M

L

K

J

H

G

F

E

D

C

4AS104K

4AI411

00AI102-A5

00AI102-A6

4AS400

F3

RAMP

1.4

3.6

OPP

OPP

4AI402

F5

4AI403

F5

LEVELS 4, 5 & 6

LEVEL 3 4AI403

C2

LEVELS 4, 5 & 6

LEVEL 34AI402

C2

GARAGE CONNECTOR ELEVATIONS & CONCOURSE CONNECTIONS

4AI401

B6

AT LEVELS 3, 4 & 5

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

4AS104-K

BLDG 4 TYPICAL PARKING LEVEL

(LEVELS 3 - 6)

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 4 LEVEL 4

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

10 BULLETIN 011D MAY 31, 2013

CR

RFI 07592

RFI 07821

at Levels

4 and 6 only

File details come from the government source that posted it. Updated .