This document appears to be a plan or drawing for the first parking level of Building 5 of a medical center construction project. The drawing provides a detailed floor plan showing the layout of the parking areas, access points, and various support spaces such as an attendant office, security rooms, and an oil water interceptor. The drawing includes general notes about partition types, lighting, bollards, and other construction details. It also indicates that there are additional enlarged floor plan views in the AI400 series drawings. This appears to be a technical design document rather than a solicitation or contract document.

View the file

Other files

File Type Posted
S05 RFI Questions-Answers from COR 09-11-2024.docx DOCX document
36C25624Q1205 0001.docx DOCX document
0238-5AS102-L.pdf PDF
0213-4AS104-K.pdf PDF
0211-4AS102-K.pdf PDF
0216-4AS107-K.pdf PDF
0240-5AS104-L.pdf PDF
0243-5AS107-L.pdf PDF
0127-4SJ901.pdf PDF
0210-4AS101-K.pdf PDF
36C25624Q1205.docx DOCX document
Final SOW Employee Patient Parking Garage_01 02.docx DOCX document
0173-5SJ901.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

5AS2031

CONCOURSE

LEVEL 1

ELEV = 100'-0"

PARKING

LEVEL 1

ELEV = 100'-0"

5A I41

5A

S10 1-L

STP

STP

STAIR

STL-1

STAIR

STL-2

ATTENDANT

OFFICE

1L106

VALET GOLF CART

PARKING (2)

OVERHEAD ROLLING

METAL DOOR

OVERHEAD ROLLING

METAL DOOR

5AI401

B6

5AI401

B3

5AI401

B5

5AI402

C5

C

D

E

F

G

H

J

K

L

M

N

5" EJ

SECURITY

1L108

TEL-DATA

1L110

SECURITY

1L105

TEL-DATA

1L107

5AI401

B2

5AS201

5AS202

5AS205

5AS206

E5

1 F3

5AI402

PROCESS WATER TANKS -

SEE STRUCT

00AI101-A6

6AI101-M3

AI

1-

A 6 5A

I4

RAMP

3.6

ACCESS LADDER

ACCESS LADDER

0AF601

C2

0IF401

D4

0AF601

F2

0AF601

D2

SEE DET D3/0AS201 FOR LOCATION

OFLIGHTING ABOVE DOOR; TYPICAL

OF ALL GRADE LEVEL EXTERIOR

EXIT DOORS

0AS507

E2

SEE STRUCTURAL DRAWINGS FOR

LOCATION & QUANTITY OF

BOLLARDS, ALL LEVELS THIS LOCATION

SEE STRUCTURAL DRAWINGS FOR

LOCATION & QUANTITY OF BOLLARDS

1L111

OIL

WATER

INTERCEPTOR

1L111

'-0

10 10

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

5AS101-L

BLDG 5 OVERALL FIRST PARKING LEVEL

DV MAGJUNE 30, 2011

CONSTRUCTION DOCUMENTS 1

629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MAINTENANCE

EWP_04

SCALE: 1/16" = 1'-0"1 BLDG 5 LEVEL 1

1. GENERAL PARTITION TYPES: REFER TO SHEET 0AS002 FOR PARTITION

SCHEDULE AND GENERAL PARTITION TYPE NOTES.

2. ENLARGED PLANS: REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN

VIEWS INCLUDING MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH POCHE DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARITION SCHEDULE SHEET 0AS002

FOR MORE INFORMATION.

4. DIMENSIONS: UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISH

FACE.

5. PIPE GUARDS: PROVIDE PIPE GUARDS AT ALL PIPE AND CONDUIT

EXPOSED TVEHICULAR TRAFFIC. SEE E5/0AS510 FOR DETAILS.

6. LIGHTING: REFER TO ELECTRICAL DRAWINGS FOR GARAGE LIGHTING

LAYOUT.

7. POLE LIGHTING: LEVEL 7 POLE MOUNTED LIGHTS - REFER TO 4D/4SJ502

FOR POLE MOUNTING DETAIL AT COLUMN AND DETAILS 2D, 2E, & 3C/4SJ504

FOR PCC POLE SUPPORT FOR LIGHTS LOCATED IN GAPS BETWEEN STITCH

WALLS

8. BOLLARDS: REFER TO DETAILS 2F, 4F, & 5F/4SJ502 FOR BOLLARD

MOUNTING AT ELEVATED SLABS AND DETAILS 7&8/4SJ013 FOR BOLLARD

MOUNTING AT SOG

GENERAL FLOOR PLAN NOTES

NOTE: FIRE EXTINGUISHER CABINETS

HAVE BEEN REMOVED FROM EWP-04

2 ADDENDUM #2 JULY 29, 2011

4 ADDENDUM #4 AUGUST 5, 2011

6 ADDENDUM #6 - POST BID JANUARY 27, 2012

7 BULLETIN 005 APRIL 24, 2012

10 BULLETIN 011D MAY 31, 2013

RFI-02548: Overhead rolling metal doors deleted in Bulletin 11D

RFI-02548: Finish Layout to match C2/0AF601

RFI-02548: Should refer to C3/0IF401