This is a Reflected Ceiling Plan (RCP) and Roof Plan architectural drawing prepared by V3 Architecture & Engineering for the California Department of Corrections and Rehabilitation's San Quentin Rehabilitation Center Upper Yard Phase 2 project located at 100 Main Street, San Quentin, California. The drawing, dated February 26, 2025, specifies the roof system components and layout for the project, including metal roof panels, polycarbonate roof panels, roof gutters, downspouts, and associated hardware. The plan indicates new structural support requirements referenced in separate structural drawings and shows detailed specifications for materials including 14-gauge stainless steel downspout straps, standing seam metal roofing, 2-inch closure flashing, and polycarbonate drip edge systems. The drawing includes both a roof plan and ground-level reflected ceiling plan at 1/16-inch scale, along with detailed sections at larger scales (3/4-inch and 1-1/2-inch) illustrating downspout transitions and connections to existing storm drain infrastructure.
The architectural drawing serves as a reference document supporting the state and local contract opportunity FPCM-SQRC-I001125-1125-087-A-RS for roof panels and accessories. This product-only solicitation requires bidders to review the complete Invitation for Bid and any addendums for information essential to the bidding process. The drawing was prepared under the supervision of Loyd Rolle, Supervising Architect, and Shan Li, Senior Architect, with approval contingent upon compliance with all applicable regulations and no omission or deviation from specification requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
110-A
26a 26b 26c
09 08
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
A2.2
A3.3
S P
A C
IN
G
P
U R
L
IN
S P
A C
IN
G
P
U R
L
IN
S P
A C
IN
G
P
U R
L
IN
S P
A C
IN
G
P
U R
L
IN
S P
A C
IN
G
P
U R
L
IN
10 10 10
A2.2
41' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 6"
88 84
110-A
26a 26b 26c
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
LEGEND
METAL ROOF PANEL
POLYCARBONATE ROOF PANEL
ADJACENT BUILDING
14 GA ⌀4"
STAINLESS
STEEL
DOWNSPOUT
STRAP
S E
E S
T R
U C
T U
R A
L D
W G
SEE STRCTURAL DWG
3' - 4 1/2"
CONCRETE
SIDEWALK
A3.3
CONNECT TO
STORMDRAIN
PIPE
4-3/4
APPROXIMATE PER
RECORD DWG
DOWNSPOUT
BOOT
TUBE MULLION
BASE CHANNEL
SOLID
POLYCARBONATE
SYSTEM END CAP
(WITH WEEP HOLES
FOR WATER
DRAINAGE)
PLASTIC TUBE CAP
2" TALL
STANDING SEAM
METAL ROOF
(E) PURLIN
NEW STRUCTURAL
SUPPORT, SEE
STRUCTURAL
DWGS
POLYCARBONATE
DRIP EDGE
BONDED TO PANEL
MOUNTING BASE
2"
CLOSURE
FLAHSING
BETWEEN
MULLIONS - POP
RIVET TO EAVE
FLASHING
CONT. EAVE
FLASHING
BETWEEN MULLION
AND TUBE
R E
V
IT
F
IL
E
DATE:
SHEET NUMBER
A
B
C
D
E
F
G
H
J
K
L
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OF SHEETS V3
ARCHITECTURE & ENGINEERING
CALIFORNIA DEPARTMENT OF
CORRECTIONS AND REHABILITATION
CALIFORNIA DEPARTMENT OF
CORRECTIONS AND REHABILITATION
ACCESS COMPLIANCE REVIEW
APPROVAL OF THIS PLAN DOES NOT AUTHORIZE
OR APPROVE ANY OMMISION OR DEVIATION
FROM APPLICABLE REGULATIONS
LOYD ROLLE
SUPERVISING ARCHITECT
SHAN LI
SENIOR ARCHITECT
D L S
\S Q
R C
\2 -0
\0 D
R A
W
IN
G S
\3 A
A c ti v e D ra w in g s \2
-0
S Q
R C
.r v t
/2
/2
:3 :3
P
M
A2.2
R C
P A
N D
R O
O F
P L
A N
02/26/2025
S Q
R C
U P
P E
R Y
A R
D P
H A
S E
24-026
S A
N Q
U E
N T
IN
R
E H
A B
IL
IT
A T
IO
N
C E
N T
E R
M
A
IN
S T
S
A N
Q U
E N
T
IN
C
A
SQRC
1/16" = 1'-0"ROOF PLAN 3
08 (N) ROOF PANEL
09 (N) ROOF GUTTER
10 (N) DOWNSPOUT
83 (E) GUARD WALK W/ (N) PAINT
84 (E) GUARDRAIL W/ (N) PAINT
88 PATCH AND PAINT GUARD WALK AND GUARDRAIL AFTER STATION
REMOVAL
KEYNOTE
1/16" = 1'-0"GROUND LEVEL REFLECTED CEILING PLAN 2
3/4" = 1'-0"DOWNSPOUT 4
1 1/2" = 1'-0"TRANSITION DETAIL 1
REV. DATE: DESCRIPTION
4 09/26/25 CB-04
| Sheets |
| A2.2 - RCP AND ROOF PLAN |
| A3.3 - DETAILS |
| G1.0 - COVER SHEET |
| R1.1 - RECORD DRAWING FOR REFERENCE ONLY |
| R1.2 - RECORD DRAWING FOR REFERENCE ONLY |
| R1.3 - RECORD DRAWING FOR REFERENCE ONLY |
File details come from the government source that posted it. Updated .