01 R100 052626.pdf
PDF 247 KB Posted
- Solicitation number
- 57-10005-27-FA-RLP
About this file
This is a Request for Lease Proposals (RLP) issued by the USDA for office space in Georgetown, Sussex County, Delaware.
The Government seeks to procure 10,384 to 10,903 ABOA square feet (not to exceed 11,941 rentable square feet) of contiguous space on a single floor, consisting of two components: (1) a direct lease for the USDA Service Center (FSA and NRCS) requiring 7,206 to 7,566 ABOA SF (not exceeding 8,286 RSF), and (2) NRCS Partner Fit-Out Space requiring 3,178 to 3,337 ABOA SF (not exceeding 3,655 RSF) to be leased separately by the lessor to the NRCS Partner. The lease term is thirteen (13) years with a firm term of ten (10) years for the USDA Service Center; the Government may terminate after the firm term with 120 calendar days' notice. Renewal options are not available. The space must be located in a modern quality building with proper facade materials and, if not new, must undergo modernization or adaptive reuse by occupancy. Offerors must provide seventy-four (74) parking spaces: six (6) reserved government spaces in a secured wareyard, twenty-six (26) reserved producer/visitor spaces (including two oversized spaces), and forty-two (42) non-reserved employee spaces either onsite or within 1,320 feet walkable distance.
Eligibility requirements include ENERGY STAR® certification (or statutory exceptions with cost-effective energy improvements), no asbestos-containing materials or only undamaged nonfriable ACM, compliance with fire protection and life safety standards, accessibility requirements, and environmental due diligence including Phase I Environmental Site Assessment. Proposals are due by 4:30 PM Eastern on July 16, 2026, submitted via email to Shannon.Schoening@USDA.GOV. Offerors must provide GSA Forms 1217 and 1364 with fully serviced turnkey lease rates (gross rates) per ABOA and RSF, clearly itemizing building shell rental, tenant improvement amortization, operating costs, and parking. Design Intent Drawings must be completed prior to award following a DID workshop. The award will be made to the responsible offeror whose offer is lowest priced and technically acceptable, evaluated on annual price per ABOA SF using present value analysis. Offerors must demonstrate active SAM registration, submit proof of signing authority, evidence of financing or financial resources, local zoning compliance, and property ownership documentation.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GSA TEMPLATE R100 (5/26)
USDA REQUEST FOR
LEASE PROPOSALS
NO. 57-10005-27-FA,
GEORGETOWN,
SUSSEX COUNTY,
DELAWARE
Offers due by 07/16/2026
In order to be considered for award, offers conforming to the requirements of the RLP must be received no later than 4:30 PM EASTERN on the date above. See “Receipt Of Lease Proposals” herein for additional information.
This Request for Lease Proposals ("RLP") sets forth instructions and requirements for proposals for a Lease described in the RLP documents. Proposals conforming to the RLP requirements will be evaluated in accordance with the Method of Award set forth herein to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions herein.
The information collection requirements contained in this Solicitation/Contract, that are not required by regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No. 3090-0086.
GLOBAL RLP
TABLE OF CONTENTS
SECTION 1 STATEMENT OF REQUIREMENTS
1.01 GENERAL INFORMATION (FEB 2026)
1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (FEB 2026)
1.03 AREA OF CONSIDERATION (OCT 2021)
1.04 UNIQUE REQUIREMENTS (OCT 2021)
1.05 NEIGHBORHOOD, PARKING, LOCATION AMENITIES, AND PUBLIC TRANSPORTATION (FEB 2026)
1.06 LIST OF RLP DOCUMENTS (MAY 2026)
1.07 AMENDMENTS TO THE RLP (JUN 2012)
1.08 LEASE DESCRIPTION (FEB 2026)
1.09 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)
1.10 PRICING OF SECURITY REQUIREMENTS (FEB 2026)
1.11 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)
1.12 AUTHORIZED REPRESENTATIVES (FEB 2026)
1.13 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT
2023)
SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD
2.01 EFFICIENCY OF LAYOUT (AUG 2011)
2.02 FLOODPLAINS (FEB 2026)
2.03 INTENTIONALLY DELETED
2.04 INTENTIONALLY DELETED
2.05 ASBESTOS (FEB 2026)
2.06 ACCESSIBILITY (SEP 2013)
2.07 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)
2.08 ENERGY INDEPENDENCE AND SECURITY ACT (FEB 2026)
2.09 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)
2.10 DUE DILIGENCE AND NATIONAL ENVIRONMENTAL POLICY ACT REQUIREMENTS - RLP (OCT 2023)
2.11 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS - RLP (FEB 2026)
SECTION 3 HOW TO OFFER
3.01 INSTRUCTIONS FOR OFFEROR AND SUBMITTALS (FEB 2026)
3.02 RECEIPT OF LEASE PROPOSALS (FEB 2026)
3.03 PRICING TERMS (FEB 2026)
3.04 BUDGET SCOREKEEPING; OPERATING LEASE TREATMENT (APR 2011)
3.05 TENANT IMPROVEMENTS INCLUDED IN OFFER (FEB 2026)
3.06 TURNKEY PRICING WITH DESIGN INTENT DRAWINGS PRIOR TO AWARD (FEB 2026)
3.07 SECURITY IMPROVEMENTS INCLUDED IN OFFER (FEB 2026)
3.08 OPERATING COSTS REQUIREMENTS INCLUDED IN OFFER (FEB 2026)
SECTION 4 METHOD OF AWARD
4.01 NEGOTIATIONS (FEB 2026)
4.02 HUBZONE SMALL BUSINESS CONCERN PRICE PREFERENCE WAIVER (FEB 2026)
4.03 AWARD BASIS (FEB 2026)
4.04 PRESENT VALUE PRICE EVALUATION (FEB 2026)
4.05 AWARD (MAY 2026)
SECTION 5 ADDITIONAL TERMS AND CONDITIONS
5.01 MODIFIED RLP PARAGRAPHS (OCT 2016)
RLP NO. 57-10005-27-FA, PAGE 1 GSA TEMPLATE R100 (5/26)
REQUEST FOR LEASE PROPOSALS
NO. 57-10005-27-FA 05/26/2026
GLOBAL RLP GSA TEMPLATE R100 (MAY 2026)
SECTION 1 STATEMENT OF REQUIREMENTS
1.01 GENERAL INFORMATION (FEB 2026)
A. This Request for Lease Proposals (RLP) sets forth instructions and requirements for proposals for a Lease described in the RLP documents.
The Government will evaluate proposals conforming to the RLP requirements in accordance with the Method of Award set forth below to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions below.
B. Included in the RLP documents is a lease template setting forth the lease term and other terms and conditions of the Lease contemplated by this RLP and a GSA Proposal to Lease Space (GSA Form 1364) on which Offeror must submit its offered rent and other price data, together with required information and submissions. The Lease paragraph titled “Definitions and General Terms” must apply to the terms of this RLP.
C. Do not attempt to complete the lease template. Upon selection for award, USDA will transcribe the successful Offeror’s final offered rent and other price data included on the GSA Form 1364 into the lease and transmit the completed Lease, including any appropriate attachments, to the successful Offeror for execution. Neither the RLP nor any other part of an Offeror’s proposal must be part of the Lease except to the extent expressly incorporated therein. The Offeror should review the completed Lease for accuracy and consistency with his or her proposal, sign and date the first page, initial each subsequent page of the Lease, and return it to the Lease Contracting Officer
(LCO).
D. The Offeror's executed Lease must constitute a firm offer. No Lease must be formed until the LCO executes the Lease and delivers a signed copy to the Offeror.
E. Offeror may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA or Department of Agriculture
(USDA), in the entity name that owns and/or leases the Space to USDA.
1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (FEB 2026)
A. The Government is seeking to procure the following square feet of American National Standards Institute/Building Owners and Managers
Association (ANSI/BOMA) Occupant Area (ABOA) square feet (SF) of contiguous space within the Area of Consideration set forth below.
See Section 2 of the Lease for applicable ANSI/BOMA standards.
The USDA intends to procure a minimum of 10,384 to a maximum of 10,903 ABOA square feet, not to exceed 11,941 rentable square feet, demised and conditioned as follows:
1. USDA Direct Lease Space:
A direct lease for the USDA Service Center (FSA and NRCS) to house agency personnel, equipment, and property. The required space is a minimum of 7,206 to a maximum of 7,566 ABOA square feet, not to exceed 8,286 rentable square feet.
2. NRCS Partner Fit-Out Space:
The USDA will secure the NRCS Fit Out Space needed for NRCS/Partner personnel and operations and will provide space for the NRCS Partner to negotiate a separate lease for a minimum of 3,178 to a maximum of 3,337 ABOA square feet, not to exceed 3,655 rentable square feet. The USDA will not participate in these negotiations. See Section 1.04 of the RLP for additional information.
B. The Space shall be located in a modern quality Building of sound and substantial construction with a facade of stone, marble, brick, stainless steel, aluminum or other permanent materials in good condition and acceptable to the LCO. If not a new Building, the Space offered shall be in a Building that has undergone, or will complete by occupancy, modernization or adaptive reuse for the Space with modern conveniences.
C. The Government requires SEVENTY-FOUR (74) parking spaces, as follows:
1. Government Surface/ Outside Reserved Parking Spaces:
SIX (6) reserved, onsite surface parking spaces for official government vehicles owned or leased on behalf of the Government or privately owned vehicles designated for official use in performance of the Government’s mission. These spaces shall be located within the secured/fenced wareyard. See EXHIBIT B for secured/fenced parking/wareyard requirements.
2. Producer/ Visitor Surface/Outside Reserved Parking Spaces:
TWENTY-SIX (26) reserved, onsite surface parking spaces for privately owned producer/visitor parking:
a. The parking lot shall have pull-through capabilities and shall not be obstructed by adjacent buildings, structures, and/or other tenant usage.
b. Parking shall be within a maximum of 300 feet of the public entrance of the building.
RLP NO. 57-10005-27-FA, PAGE 2 GSA TEMPLATE R100 (5/26)
c. TWO(2) of the producer/visitor parking spaces shall be large enough to accommodate large, oversized, farm-type vehicles with trailers. These spaces shall be included in the pull-through requirement.
3. Employee Surface/ Outside Non-Reserved Parking Spaces:
FORTY-TWO (42) non-reserved parking spaces for privately owned lease employee use. These parking spaces shall either be on-site or off-site not exceeding ¼ walkable mile (1,320 feet) of the employee entrance of the building.
4. These spaces must be secured and lit in accordance with the Security Requirements set forth in the Lease. Offeror must include the cost of this parking as part of the rental consideration.
D. As part of the rental consideration, the Government may require use of part of the Building roof for the installation of antenna(s). If antenna space is required, specifications regarding the type of antenna(s) and mounting requirements are included in the agency requirements information provided with this RLP.
E. The Government may provide vending machines within the Government's leased area under the provisions of the Randolph-Sheppard Act
(20 UC 107 et. seq.). If the Government chooses to provide vending facilities, the Government will control the number, kind, and locations of vending facilities and will control and receive income from all automatic vending machines. Offeror must provide necessary utilities and make related alterations. The cost of the improvements is part of Tenant Improvement (TI) costs. The Government will not compete with other facilities having exclusive rights in the Building. The Offeror must advise the Government if such rights exist.
F. The lease term for both the USDA Service Center and the NRCS Fit-Out Space shall be THIRTEEN (13) Years (156 Months) full. The firm term shall be:
1. USDA Service Center: TEN (10) Years (120 Months)
2. NRCS Fit-Out Space: The USDA lease will not include a firm term for the NRCS Fit-Out Space. Any firm term will be negotiated in the separate lease between the Lessor and the NRCS Partner, as required by paragraph 1.04.A of this RLP. Any firm term negotiated for the NRCS Partner lease shall not exceed the USDA firm term described in paragraph 1.02.F.1.
Government Termination Rights (in whole or in part)
3. USDA Service Center: The Government may terminate after the firm term with 120 calendar days’ notice.
4. NRCS Fit-Out Space: See paragraph 1.04.A of this RLP.
5. Renewal Options: There are no renewal options terms.
The Government reserves the right to reduce the firm or full lease terms if the inclusion of the term would cause the Lease to score as a capital lease, in accordance with the Budget Scorekeeping: Operating Lease Treatment paragraph of this RLP. Should the Government make the determination to modify the term or option(s), an amendment to the RLP will be issued by the USDA contracting officer or designee.
1.03 AREA OF CONSIDERATION (OCT 2021)
The Government requests Space in an area bounded as follows:
North: Beginning at the intersection of US-13 (Sussex Highway) and DE-36/ DE-16 (Beach Highway/ Main Street/ Milton-Ellendale Highway) ending at DE-5 (Union Street);
East: Beginning at the intersection of DE-16 (Milton-Ellendale Highway) and DE-5 (Union Street/ Federal Street/ Harberson Road/ Indian
Mission Boulevard) and DE-24 (John J. Williams Highway);
South: Beginning at the intersection of DE-5 (Indian Mission Boulevard) and DE-24 (John J. Williams Highway) to DE-5/ DE-24 (Main Street/
Washington Street/ Laurel Road) to DE-30/ DE-24 (Millsboro Highway) to DE-24 (Laurel Road) ending at the intersection of DE-24 (Laurel Road) and US- 13 (Sussex Highway);
West: Beginning at the intersection of DE-24 (Laurel Road)/ US-13 (Sussex Highway) ending at the intersection of US-13 (Sussex Highway) and DE- 16 (Beach Highway). Buildings with Property boundary(ies) on the boundary streets are deemed to be within the delineated Area of Consideration.
1.04 UNIQUE REQUIREMENTS (OCT 2021)
A. Within 120 calendar days following award of the direct lease with the USDA, the successful Lessor shall negotiate and award a separate lease with the NRCS Partner for the NRCS Fit Out Space.
1. Any lease agreement made between the Lessor and the NRCS Partner shall:
a. not provide less than nor exceed the NRCS Fit Out Space minimum and maximum ABOA SF and not to exceed RSF described in paragraph 1.02.A.2 of this RLP,
b. not provide less than the parking quantities described in paragraph 1.02.C of this RLP,
c. not exceed the Lease Term requested in paragraph 1.02.F of this RLP,
d. not to exceed the termination rights requested in paragraph 1.02.F of this RLP, and
e. shall be commenced in accordance with paragraph 1.08.F of this RLP.
RLP NO. 57-10005-27-FA, PAGE 3 GSA TEMPLATE R100 (5/26)
2. The terms of any lease agreement between the successful Lessor and the NRCS Partner shall reflect the NRCS Partner’s rent/direct lease costs and its share of operating expenses, based on its pro‑rata share of the space it occupies.
3. The USDA, its contracting official(s), or designees shall not intercede, participate in, or interfere with negotiations between the successful Lessor and the NRCS Partner.
4. The USDA, its contracting official(s), or designees shall not be responsible for any omissions or errors by either the successful Lessor or the NRCS Partner in the negotiation or award of the separate lease agreement.
5. Upon successful negotiations and award of a separate lease agreement between the successful Lessor and the NRCS Partner, and notification of the same by the Lessor to the USDA contracting official(s) or designee, the USDA shall execute a bilateral lease amendment to remove the NRCS space and its space requirements from the USDA lease.
6. If a separate lease agreement is not reached between the successful Lessor and the NRCS Partner within 120 calendar days after award of the USDA lease, the USDA contracting official(s) or designee shall execute a bilateral lease amendment to remove the NRCS Fit Out Space and its space requirements in their entirety from the USDA lease.
7. The timeframes and actions described in Clauses 5 and 6 are firm. No extensions of time or waivers of these requirements will be granted by the USDA contracting official(s) or designees.
B. The offered Building and/or Property must have the following features as a minimum requirement:
1. The space offered, its location and its surrounding areas must be compatible with the Government’s intended usage.
2. The space offered shall not be located within 300-feet of residential areas.
3. The space offered will not be considered where living quarters are located within the building.
4. The space offered shall not be adjacent to a tenant or business whose primary operation is the sale of alcoholic beverages, where firearms are sold and/or discharged, or where tenants related to drug treatment or detention facilities are located.
5. Subleases are not acceptable.
6. First floor space is preferred Space must be contiguous, on one floor. If space is offered above the ground level, then at least one (1) accessible elevator will be required.
1.05 NEIGHBORHOOD, PARKING, LOCATION AMENITIES, AND PUBLIC TRANSPORTATION (FEB 2026)
A. INTENTIONALLY DELETED
B. Neighborhood and Parking. Outside City Center: Space must be located 1) in an office, research, technology, or business park that is modern in design with a campus-like atmosphere; or, 2) on an attractively landscaped site containing one or more modern office Buildings that are professional and prestigious in appearance with the surrounding development well maintained and in consonance with a professional image. The parking-to-square-foot ratio available onsite must at least meet current local code requirements, or, in the absence of a local code requirement, on-site parking must be available at a ratio of one (1) space for every 200 RSF of Space.
C. Walkability and Amenities.
1. Employee and visitor entrances of the Building must be connected to public sidewalks by continuous, accessible sidewalks.
2. INTENTIONALLY DELETED
D. INTENTIONALLY DELETED
1.06 LIST OF RLP DOCUMENTS (MAY 2026)
A. The following documents are attached to and included as part of this RLP package:
DOCUMENT NAME
NO. OF
PAGES
RLP
EXHIBIT
LEASE
EXHIBIT
GSA Form 3516, Solicitation Provisions (REV 3/26) 7 A ---------- Procurement Summary 3 B ---------- Offer Submittal Checklist – For Use with Global RLP Packages 1 C ---------- RLP No. 57-10005-27-FA (Template R100) (05/26) 19 D ---------- Lease No. 57-10005-27-FA (Template L100) 35 ---------- A Agency Special/Specific Requirements – Georgetown, Sussex County, Delaware 21 ---------- B Addendum 1 to EXHIBIT B 1 Addendum 1 ---------- USDA Infrastructure Operations Division ADP and Wiring Guidelines Version 3.0 11 ---------- C USDA Facility Signage Guide (April 2014) 11 ---------- D Security Requirements – Facility Security Level I 4 ---------- E DOL Wage Determination (Davis-Bacon Act WD #: DE20260009) (Jan 2, 2026) 7 ---------- F Tenant Improvement Cost Summary (TICS) Workbook 30 ---------- G GSA 3517B, General Clauses 33 ---------- H
RLP NO. 57-10005-27-FA, PAGE 4 GSA TEMPLATE R100 (5/26)
GSA Form 1217, Lessor's Annual Cost Statement 2 E ---------- GSA Form 1364, Proposal to Lease Space 4 F ---------- GSA Form 12000 for Prelease Fire Protection and Life Safety Evaluation for an Office Building (Part A or Part B) (See Section 3 for applicable requirements)
2 G ----------
New Construction RLP Exhibit 1 H ---------- Swing Space RLP Exhibit 2 I ---------- New Construction RLP Exhibit 3 ---------- I Swing Space RLP Exhibit 1 ---------- J
B. In addition to the documents identified above, this RLP package includes additional agency requirements containing sensitive information that is only available to Offerors upon request to the LCO or Alternate Government Contact as listed under Section 1 of this RLP.
1.07 AMENDMENTS TO THE RLP (JUN 2012)
This RLP may be amended by notice from the LCO. Amendments may modify the terms of this RLP, or the terms, conditions, and requirements of the Lease contemplated by the RLP.
1.08 LEASE DESCRIPTION (FEB 2026)
A. Offeror must examine the Lease template included in the RLP documents to understand the Government's and the Lessor's respective rights and responsibilities under the contemplated Lease.
B. The Lease contemplated by this RLP includes:
1. The term of the Lease, and renewal option, if any.
2. Terms and Conditions of the Lease, including Definitions, Standards, and Formulas applicable to the Lease and this RLP.
3. Building Shell standards and requirements.
4. Information concerning the tenant agency's buildout requirements, to be supplemented after award.
5. Security Requirements.
6. A description of all services to be provided by the Lessor.
C. Should the Offeror be awarded the Lease, the terms of the Lease must be binding upon the Lessor without regard to any statements contained in this RLP.
D. The Lease contemplated by this RLP is a fully serviced, turnkey Lease with rent that covers all Lessor costs including all shell upgrades, TIs, operating costs, real estate taxes, and security upgrades. Rent will be based upon a proposed rental rate per rentable square foot (RSF), limited by the offered rate and the maximum ABOA SF solicited under this RLP. The Tenant Improvements to be delivered by the Lessor must be based upon information provided with this RLP and Lease, including Agency Specific Requirements (ASR). The Lessor must design and build the TIs and will be compensated for the TI costs based upon turnkey pricing established under the Lease.
Offerors are required to prepare Design Intent Drawings (DIDs) prior to Lease Award. See Paragraph TURNKEY PRICING WITH DESIGN INTENT DRAWINGS PRIOR TO AWARD for further details.
E. The security pricing process is described in a separate paragraph.
F. Upon completion and acceptance of the leased Space, the lease term must commence. In instances involving an incumbent Lessor where the Government commences the lease term pending completion of TI alterations, the Government must withhold TI rent pursuant to Section 1 of the Lease until such time as the TI is completed and accepted by the Government.
G. Offerors are advised that doing business with the Government carries special responsibilities with respect to fire protection and life safety, and security, as well as other requirements not typically found in private commercial leases. These are set forth both in the lease template and in the GSA 3517B, General Clauses, and will be made part of the Lease.
1.09 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)
The Lease establishes various requirements relating to the Building shell. Such requirements are not deemed TIs. There are certain Building requirements that are established as minimum requirements in this RLP. If the Lessor's Building does not meet the requirements at the time of award, the Lessor may still be awarded the Lease. However, as a condition of award, the Government will require Lessor to identify those Building improvements that will bring the Building into compliance with RLP requirements. Upon award of the Lease, completion of those Building improvements will become Lease obligations.
1.10 PRICING OF SECURITY REQUIREMENTS (FEB 2026)
A. The proposed Lease contains an attachment with the security requirements and obligations for the Building, which are based on the facility security level (FSL). The Federal Government determines the facility’s FSL rating, which ranges from FSL I to FSL IV. The FSL is based on client agency mix, required size of space, number of employees, use of the space, location, configuration of the site and lot, and public access into and around the facility.
B. The security requirements attached to this Lease includes a list of security countermeasures that must be installed in the leased Space.
The Offeror must provide the Government with these security countermeasures, and he or she must amortize the cost into the rent.
C. There must be no charge to the Government for any items that already exist in the offered Building or facility.
RLP NO. 57-10005-27-FA, PAGE 5 GSA TEMPLATE R100 (5/26)
1.11 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)
If an Offeror is offering Space in a facility currently housing a Federal agency, the security requirements of the facility may be increased and the Offeror may be required to adhere to a higher security standard than other Offerors competing for the same space requirement. If two or more Federal space requirements are being competed at the same time, an Offeror submitting on both or more space requirements may be subject to a higher security standard if the Offeror is determined to be the successful Offeror on more than one space requirement. It is incumbent upon the Offeror to prepare the Offeror’s proposal accordingly.
1.12 AUTHORIZED REPRESENTATIVES (FEB 2026)
With respect to all matters relating to this RLP, only the Government's LCO designated below must have the authority to amend the RLP and award a Lease. The Government must have the right to substitute its LCO by notice, without an express delegation by the prior LCO.
Lease LCO:
Shannon Schoening
SHANNON.SCHOENING@USDA.GOV
1.13 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT
2023)
A. The North American Industry Classification System (NAICS) code for this acquisition is 531120 (Exception).
B. The small business size standard for the applicable NAICS code is found HTTPS://WWW.SBA.GOV/SIZE-STANDARDS/.
RLP NO. 57-10005-27-FA, PAGE 6 GSA TEMPLATE R100 (5/26)
SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD
2.01 EFFICIENCY OF LAYOUT (AUG 2011)
A. In order to be acceptable for award, the offered Space must provide for an efficient layout as determined by the LCO.
B. To demonstrate potential for efficient layout, USDA requests the Offeror to provide a test fit layout at the Offeror’s expense. The
Government will advise the Offeror if the test fit layout demonstrates that the Government's requirement cannot be accommodated within the Space offered. The Offeror will have the option of increasing the ABOA square footage offered, if it does not exceed the maximum ABOA square footage in this RLP offer package. If the Offeror is already providing the maximum ABOA square footage and cannot house the Government's space requirements efficiently, then the Government will advise the Offeror that the offer is unacceptable.
2.02 FLOODPLAINS (FEB 2026)
A Lease will not be awarded for any offered Property located within a .2-percent-annual-chance floodplain (formerly referred to as 500-year floodplain) unless the Government has determined that there is no practicable alternative. An Offeror may offer less than its entire site in order to exclude a portion of the site that falls within a floodplain, so long as the portion offered meets all the requirements of this RLP and does not impact the Government’s full use and enjoyment of the Premises. If an Offeror intends that the offered Property that will become the Premises for purposes of this Lease will be something other than the entire site as recorded in tax or other property records the Offeror must clearly demarcate the offered Property on its site plan/map submissions and must propose an adjustment to property taxes on an appropriate pro rata basis. For such an offer, the Government may determine that the offered Property does not adequately avoid development in a 1-percent-annual-chance floodplain.
In addition, a Lease will not be awarded for any offered Property adjacent to a 1-percent-annual-chance floodplain, where such an adjacency would, as determined by the Government, restrict ingress or egress to the Premises in the event of a flood, unless there is no practicable alternative.
2.03 INTENTIONALLY DELETED
2.04 INTENTIONALLY DELETED
2.05 ASBESTOS (FEB 2026)
A. The Government requires space with no asbestos-containing materials (ACM), or with undamaged, nonfriable ACM. For purposes of this paragraph, “space” includes the 1) space offered for lease; 2) common building area; 3) ventilation systems and zones serving the space offered; and 4) the area above suspended ceilings and engineering space in the same ventilation zone as the space offered.
Notwithstanding the preceding, if no offers are received for such space, the Government may consider space with thermal system insulation ACM (e.g., wrapped pipe or boiler lagging), which is not damaged or subject to damage by routine operations.
B. ACM is defined as any material with a trace or more of asbestos quantity present.
C. Space with ACM of any type or condition may be upgraded by the Offeror to meet conditions described in sub-paragraph A by abatement
(removal, enclosure, encapsulation, or repair) of ACM not meeting those conditions. If any offer involving abatement of ACM is accepted by the Government, the successful Offeror will be required to successfully complete the abatement in accordance with OSHA (29 CFR § 1910.1001, 29 CFR § 1926.1101), EPA (40 CFR Part 61 - National Emission Standards for Hazardous Air Pollutants and Part 763), state, and local regulations and guidance prior to occupancy.
D. Management Plan and Reinspection Report Submittals. If space is offered which contains ACM, the Offeror must submit a current asbestos management plan or operations and maintenance plan, along with a current asbestos re-inspection report (performed within the past 5 years) that includes a list of all ACM and their condition for acceptance by the Government prior to lease award. The management plan or operations and maintenance plan, and re-inspection report must conform to generally accepted industry practice in accordance with OSHA (29 CFR § 1910.1001, 29 CFR § 1926.1101), EPA (40 CFR Part 61 - National Emission Standards for Hazardous Air Pollutants and Part 763).
E. The Government reserves the right to review Offeror’s existing records for compliance.
2.06 ACCESSIBILITY (SEP 2013)
The Lease contemplated by this RLP contains requirements for Accessibility. In order to be eligible for award, Offeror must either:
A. Verify in the Lease proposal that the Building, offered Space, and areas serving the offered Space meet the Lease accessibility requirements, or
B. Include as a specific obligation in its Lease proposal that improvements to bring the Building, offered Space, and areas serving the offered
Space into compliance with Lease accessibility requirements will be completed prior to acceptance of the Space.
2.07 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)
The Lease contemplated by this RLP contains Building requirements for Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System. In order to be eligible for award, Offeror must either:
RLP NO. 57-10005-27-FA, PAGE 7 GSA TEMPLATE R100 (5/26)
A. Verify in the Lease proposal that the Building in which Space is offered meets the Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System requirements of the Lease; or
B. Include as a specific obligation in its Lease proposal that improvements to bring the Building into compliance with Lease requirements will be completed prior to acceptance of the Space.
2.08 ENERGY INDEPENDENCE AND SECURITY ACT (FEB 2026)
A. The Energy Independence and Security Act (EISA) establishes requirements for Government leases relating to energy efficiency standards and potential cost-effective energy efficiency and conservation improvements.
B. Subject to the exceptions below, unless one of the statutory exceptions listed in sub-paragraph C below applies, USDA may award a lease for a Building only if the Building has earned the ENERGY STAR® label conferred by the U.S. Environmental Protection Agency (EPA) within the most recent year prior to the due date for final proposal revisions. The term “most recent year” means that the date of award of the ENERGY STAR® label by EPA must not be more than 1 year prior to the due date of final proposal revisions. For example, an ENERGY STAR® label awarded by EPA on October 1, 2023, is valid for all lease procurements where final proposal revisions are due on or before September 30, 2024. Notwithstanding the above, buildings that meet any of the following are considered as equivalent to having an Energy Star label in the most recent year, provided they achieve an ENERGY STAR® label within 18 months after occupancy by the Government:
1. All new Buildings being specifically constructed for the Government, provided they achieve an ENERGY STAR® label within 18 months after occupancy by the Government, and received the “Designed to Earn the Energy Star®” certification prior to construction;
2. All existing Buildings that have had an Energy Star® label but are unable to obtain a label in the most recent year (i.e., within 12 months prior to the due date for final proposal revisions) because of insufficient occupancy;
3. Newly built Buildings that have used Energy® Star’s Target Finder tool and either achieved a “Designed to Earn the Energy Star®” certification or received an unofficial score (in strict adherence to Target Finder’s usage instructions, including the use of required energy modeling) of 75 or higher prior to the due date for final proposal revisions and who are unable to obtain a label in the most recent year because of insufficient occupancy; or
4. An existing Building that is unable to obtain a label because of insufficient occupancy but that can produce an indication, through the use of energy modeling or past utility and occupancy data input into Energy Star’s® Portfolio Manager tool or Target Finder, that it can receive an unofficial score of 75 or higher using all other requirements of Target Finder or Portfolio Manager, except for actual data from the most recent year.
C. Subject to subparagraph D below, EISA allows a Federal agency to lease Space in a Building that does not have an ENERGY STAR®
Label if:
1. No Space is offered in a Building with an ENERGY STAR® Label that meets RLP requirements, including locational needs;
2. The agency will remain in a Building it currently occupies;
3. The Lease will be in a Building of historical, architectural, or cultural significance listed or eligible to be listed on the National Register of Historic Places; or
4. The Lease is for 10,000 RSF or less.
D. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, Offerors are required to include in their lease proposal an agreement to renovate the Building for all energy efficiency and conservation improvements that it has determined would be cost effective over the Firm Term of the Lease, if any, prior to acceptance of the Space (or not later than one year after the Lease Award Date of a succeeding or superseding lease). Such improvements may consist of, but are not limited to, the following:
1. Heating, Ventilating, and Air Conditioning (HVAC) upgrades, including boilers, chillers, and Building Automation System
(BAS)/Monitoring/Control System (EMCS).
2. Lighting Improvements.
3. Building Envelope Modifications.
E. The term "cost effective" means an improvement that will result in substantial operational cost savings to the landlord by reducing electricity or fossil fuel consumption, water, or other utility costs. The term "operational cost savings" means a reduction in operational costs to the landlord through the application of Building improvements that achieve cost savings over the Firm Term of the Lease sufficient to pay the incremental additional costs of making the Building improvements.
F. Instructions for obtaining an ENERGY STAR® Label are provided at HTTP://WWW.ENERGYSTAR.GOV/BUILDINGS/FACILITY-
OWNERS-AND-MANAGERS/EXISTING-BUILDINGS/EARN-RECOGNITION/ (use “Portfolio Manager” to apply). The ENERGY STAR® Building Upgrade Manual (HTTP://WWW.ENERGYSTAR.GOV/BUILDINGS/FACILITY-OWNERS-AND-MANAGERS/EXISTING- BUILDINGS/SAVE-ENERGY/) and Building Upgrade Value Calculator (HTTP://WWW.ENERGYSTAR.GOV/BUILDINGS/TOOLS-AND- RESOURCES/BUILDING-UPGRADE-VALUE-CALCULATOR) are tools which can be useful in considering energy efficiency and conservation improvements to Buildings.
G. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, the successful Offeror will be excused from performing any agreed-to
RLP NO. 57-10005-27-FA, PAGE 8 GSA TEMPLATE R100 (5/26)
energy efficiency and conservation renovations, and benchmarking with public disclosure (as provided in (I) below, if it obtains the ENERGY STAR® Label prior to the Government’s acceptance of the Space (or not later than one year after the Lease Award Date for succeeding and superseding leases).
H. If no improvements are proposed, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. If such explanation is unreasonable, the offer may be rejected.
I. As described in Section 3 of the Lease, successful Offerors meeting one of the statutory exceptions above must agree to benchmark and publicly disclose the Building’s current ENERGY STAR® score, using EPA’s Portfolio Manager online software application. See the Lease for additional details.
J. All new Buildings being specifically constructed for the Government must achieve the ENERGY STAR® Label within 18 months after occupancy by the Government.
2.09 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)
A. The Government requests space with no known hazardous conditions or recognized environmental conditions that would pose a health and safety risk or environmental liability to the Government.
B. Upon request by the Government, Offeror must provide all known previous use of the Building.
C. Offeror must indicate in its written offer any known hazardous conditions or environmental releases with/from the offered Space, Building or Property.
2.10 DUE DILIGENCE AND NATIONAL ENVIRONMENTAL POLICY ACT REQUIREMENTS - RLP (OCT 2023)
A. Environmental Due Diligence.
1. At the direction of the LCO, the Offeror must provide, at the Offeror’s sole cost and expense, a current Phase I Environmental Site Assessment (ESA), using the American Society for Testing and Materials (ASTM) Standard E1527-21 and timeline, as such standard may be revised from time to time. In accordance with ASTM standards, the study must be performed by an environmental professional with qualifications that meet ASTM standards. This Phase I ESA must be prepared with a focus on the Government being the “user” of the Phase I, as the term “user” is defined in E1527-21. Failure to submit the required study may result in dismissal from consideration.
2. If the Phase I ESA identifies any recognized environmental conditions (RECs), the Offeror will be responsible for addressing such
RECs, at its sole cost and expense, including performing any necessary Phase II ESA (using ASTM Standard E1903-11), performing any necessary cleanup actions in accordance with federal and state standards and requirements and submitting a proposed schedule for complying with these obligations. The Government will evaluate whether the nature of any of the RECs, the results of the Phase II, any completed cleanup, and the proposed schedule meet the Government’s needs.
B. National Environmental Policy Act.
1. While the Offeror is responsible for performing all environmental due diligence studies of the offered Property, the Government is responsible for compliance with NEPA, whether in whole or in part, on its own or with the assistance of the Offerors. NEPA requires federal agencies to consider the effects of their actions on the quality of the human environment as part of the federal decision-making process and, to that end, the Government’s obligations may, and in some cases will, be augmented by the Offerors as described in greater detail in the RLP.
2. The Government may either request information from the Offerors to help it meet its obligations under NEPA or share information provided in response to this provision with federal, state and local regulatory agencies as part of its compliance responsibilities under NEPA and other applicable federal, state and local environmental laws and regulations. Further consultation with these regulatory agencies may be necessary as part of the NEPA process.
3. The Offerors are advised that the Government may be required to release the location of each offered site and other building specific information in public hearings or in public NEPA documents. By submitting an offer in response to this RLP and without the need for any further documentation, the Offeror acknowledges and consents to such release.
4. The Government reserves the right to reject any offer where (i) the NEPA-related documentation provided by the Offeror for the offered
Property is inadequate, (ii) the offer entails unacceptably adverse impacts on the human environment, (iii) the identified adverse impacts cannot be readily mitigated, or (iv) the level of NEPA analysis is more extensive than is acceptable to the Government.
5. An Offeror must allow the Government access to the offered Property to conduct studies in furtherance of NEPA compliance. This requires research and field surveys to assess the potential impacts to the natural, social and cultural environments. Any recent studies previously conducted by the Offeror may be submitted to be included in the NEPA process.
6. The Government will not proceed with Lease award until the NEPA process is complete as evidenced by the Government’s issuance of a completed CATEX, EA or Environmental Impact Statement (EIS). Upon Lease award, any mitigation measures, whether optional or mandatory, identified and adopted by the Government will become Lease obligations. All costs and expenses for development of design alternatives, mitigation measures and review submittals for work to be performed under the Lease will be the sole responsibility of Lessor.
RLP NO. 57-10005-27-FA, PAGE 9 GSA TEMPLATE R100 (5/26)
2.11 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS - RLP (FEB 2026)
A. The Government is responsible for complying with section 106 of the National Historic Preservation Act (NHPA) of 1966, as amended, 54
U.S.C. § 306108 (Section 106). Section 106 requires federal agencies to consider the effects of their actions on historic properties prior to expending any federal funds on the undertaking. The Government is responsible for identifying whether any historic properties exist in, on, under, or near the offered Property that could be affected by the leasing action. Historic properties include both above-grade (i.e., buildings and historic districts) and below-grade (i.e., archeological sites) resources. The Government is responsible for assessing effects to identified historic properties and for consulting with the State Historic Preservation Officer (SHPO), the Tribal Historic Preservation Officer (THPO), if applicable, any local Historic Preservation or Landmarks Commission, and other interested parties, if applicable, in accordance with the implementing regulations set forth at 36 C.F.R. part 800 (Protection of Historic Properties).
B. An Offeror must allow the Government access to the offered Property to conduct studies in furtherance of the Section 106 compliance.
This requires research and field surveys to assess the potential presence of historic properties that may be affected by construction activity, both above- and below-grade. Compliance also may require below-grade testing to determine the presence of archeological resources and possible artifact recovery, recordation and interpretation mitigation measures.
C. Demolition or destruction of a historic property by an Offeror in anticipation of an award of a Government lease may disqualify the Offeror from further consideration.
D. The Government reserves the right to reject any offer where documentation for the offered Property is inadequate or otherwise indicates preservation concerns or adverse effects to historic properties that cannot be minimized or reasonably mitigated, or where the level of NHPA analysis is more extensive than is acceptable to the Government.
E. If the Government determines that the leasing action could affect historic property, the Offeror of any Property that the Government determines could affect historic property will be required to retain, at its sole cost and expense, the services of a preservation architect who meets or exceeds the Secretary of the Interior’s Professional Qualifications Standards for Historic Architecture, as amended and annotated and previously published in the Code of Federal Regulations, 36 C.F.R. part 61, and the GSA’s Qualification Requirements for Preservation Architects and Other Specialists. These standards are available at: HTTPS://WWW.GSA.GOV/REAL-ESTATE/HISTORIC- PRESERVATION/HISTORIC-PRESERVATION-POLICY-TOOLS/. The preservation architect will be responsible for developing preservation design solutions and project documentation required for review by the Government, the SHPO, the THPO, if applicable, and other consulting parties in accordance with Section 106. For Tenant Improvements and other tenant-driven alterations within an existing historic building, the preservation architect must develop context-sensitive design options consistent with the Secretary of the Interior’s Standards for the Treatment of Historic Properties. Where new construction or exterior alterations, or both, are located within a historic district, may be visible from historic properties or may affect archeological resources, compliance may require tailoring the design of the improvements to be compatible with the surrounding area. Design review may require multiple revised submissions, depending on the complexity of the project and potential for adverse effects to historic properties, to respond to comments from the Government and the other consulting parties. Within GSA, the Historic Preservation Officer is solely responsible for corresponding with the SHPO, the THPO, if applicable, and any other consulting party. All design costs and expenses relating to satisfying the requirements of this paragraph will be borne solely by the Offeror.
RLP NO. 57-10005-27-FA, PAGE 10 GSA TEMPLATE R100 (5/26)
SECTION 3 HOW TO OFFER
3.01 INSTRUCTIONS FOR OFFEROR AND SUBMITTALS (FEB 2026)
A. Offeror shall prepare a complete offer, using the forms provided with this RLP, and submit the completed lease proposal package to the
Government as indicated below. The Government will evaluate the offers received as outlined below and further described in this section.
B. Offeror shall also submit with its offer the following: See attached RLP ATTACHMENT C – 57-10005-27-FA, OFFEROR SUBMITTAL
CHECKLIST – FOR USE WITH GLOBAL RLP PACKAGES
C. Authorization to Represent Ownership. If the offeror is not the owner of the Property, authorization from the ownership entity to submit an offer on the ownership entity’s behalf.
D. Conditional Commitment of Funds. Satisfactory evidence of at least a conditional commitment of funds in an amount necessary to prepare the Space, including Shell, and TI improvements. Such commitments shall be signed by an authorized bank officer, or other legally authorized financing official, and at a minimum shall state: amount of loan, term in years, annual percentage rate, and length of loan commitment. Alternatively, if the Offeror is self-financing, Offeror must demonstrate, to the satisfaction of the LCO, that it has adequate financial resources to self-finance the necessary improvements, e.g., income statements, cash flow statements, balance sheets, three (3) months of bank statements showing sufficient on hand stable cash reserves to fund the improvements, letter from the entity’s financial officer.
E. Local Zoning Compliance. Evidence that the Property is zoned in compliance with local zoning laws, including evidence of variances, if any, approved by the proper local authority. If the current zoning is not in compliance, the Offeror must submit a plan and time schedule outlining how they will obtain all necessary zoning approvals prior to construction and how long the necessary zoning approvals will take.
F. Ownership Evidence. Evidence of ownership or control of Building or site. If the Offeror owns the Property being offered or has a long-term leasehold interest, the deed or lease must be submitted to the LCO evidencing the Offeror's stated interest in the Property and any encumbrances on the Property.
G. Agreement to Acquire an Interest in Property. If the Offeror does not yet have a vested interest in the Property, but rather has a written agreement to acquire an interest, then the Offeror shall submit a fully executed copy of the written agreement with its offer, together with a statement from the current owner that the agreement is in full force and effect and that the Offeror has performed all conditions precedent to closing, or other form of documentation satisfactory to the LCO prior to award. These submittals must remain current. The Offeror is required to submit updated documents as required.
H. Signing Authority Proof. As a condition of lease award, the Government will require one of the following forms of proof of signing authority before the Government executes the Lease:
1. Corporation. Copy of Articles of Incorporation and bylaws. In addition, a copy of the resolution, signed by the necessary directors of the corporation authorizing the corporate officer who will sign the lease to bind the corporation to the Lease.
2. Partnership. Copy of Partnership Agreement, Statement of Partnership, or Statement of Limited Partnership and evidence of authority of signatory to bind the partnership if not expressly authorized by the Partnership Agreement.
3. Limited Liability Company. Copy of the Articles of Organization and Operating Agreement. Also, evidence of the authority of the signing manager (if company is manager owned) or member (if the company is member managed) to sign, if not expressly authorized by the Articles of Organization and/or Operating Agreement.
4. Joint Venture. Copy of Joint Venture Agreement and evidence of authority of signatory to bind the Joint Venture to the Lease.
I. Conflict of Interest. If there is a potential for conflict of interest because of a single agent representing multiple owners, present evidence that the agent disclosed the multiple representations to each entity and has authorization from each ownership entity offering in response to this RLP package. Owners and agents in conflicting interest situations are advised to exercise due diligence with regard to ethics, independent pricing, and Government procurement integrity requirements. In such cases, the Government reserves the right to negotiate with the owner directly.
J. SAM Registration. The Offeror must have an active registration in the System for Award Management (SAM), via the Internet at
HTTPS://WWW.SAM.GOV/SAM/ prior to the Lease Award Date. Offerors must be registered for purposes of “All Awards,” including completion of all required representations and certifications within SAM. This registration service is free of charge.
K. Fire Protection and Life Safety (FPLS). The Offeror must submit the FPLS Information in subparagraph 1, unless the Building meets either exemption in subparagraphs 2 or 3 below.
1. FPLS Submittal Information.
a. Completed GSA Form 12000, Prelease Fire Protection and Life Safety Evaluation for an Office Building (Part A or Part B, as applicable).
b. A copy of the previous year’s fire alarm system maintenance record showing compliance with the requirements in NFPA 72 (if a system is installed in the Building).
RLP NO. 57-10005-27-FA, PAGE 11 GSA TEMPLATE R100 (5/26)
c. A copy of the previous year’s automatic fire sprinkler system maintenance record showing compliance with the requirements in NFPA 25 (if a system is installed in the Building).
d. A valid Building Certificate of Occupancy (C of O) issued by the local jurisdiction. If the Building C of O is not available or the local jurisdiction does not issue a Building C of O,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .