00324_AMD1_ExhibitB-Spec_rev11122024.docx

DOCX document 450 KB Posted

Attached to
Signal Flares And Highway Signal Devices (Fusee)
Solicitation number
00324
Issued by
Adams County, Asotin County, Benton County, Chelan County, Clallam County, Clark County, Columbia County, Cowlitz County, Douglas County, Ferry County, Franklin County, Garfield County, Grant County, Grays Harbor County, Island County, Jefferson County, King County, Kitsap County, Kittitas County, Klickitat County, Lewis County, Lincoln County, Mason County, Okanogan County, Pacific County, Pend Oreille County, Pierce County, San Juan County, Skagit County, Skamania County, Snohomish County, Spokane County, Stevens County, Thurston County, Wahkiakum County, Walla Walla County, Whatcom County, Whitman County, Yakima County, Asotin City, Clarkston City, Clarkston Heights-Vineland CDP, West Clarkston-Highland CDP, Benton City, Chelan City, Chelan Falls CDP, Clallam Bay CDP, Lewisville CDP, Rock Island City, Pacific Beach CDP, Whidbey Island Station CDP, Mercer Island City, Pacific City, Bainbridge Island City, Kingston CDP, Kitsap Lake CDP, Kittitas City, Klickitat CDP, Okanogan City, Anderson Island CDP, Fort Lewis CDP, Fox Island CDP, Herron Island CDP, Ketron Island CDP, North Fort Lewis CDP, Raft Island CDP, Stevenson City, Hat Island CDP, Lake Stevens City, Snohomish City, Spokane City, Spokane Valley City, Puget Island CDP, Garfield Town, Yakima City, Washington

About this file

This document is a detailed specification for Signal Igniter Flares and Highway Signal Devices (Fusee) for a competitive solicitation issued by the State of Washington. The specification outlines the mandatory requirements for the resulting contract, including product standards, configuration, materials, workmanship, and packaging. It notes that the supplier is only responsible for the quality of the products, while the State of Washington and any utilizing agencies, such as the Department of Transportation, are responsible for developing and enforcing safe use and deployment requirements. The specification covers a 5, 10, 15, 20, and 30 minute automatic ignition fusee/flare product as well as a manual automatic ignition chamber (MICA) used to deploy the flares from a slow-moving vehicle.

The pricing, funding, and contracting terms are not explicitly covered in this document. However, it is indicated that this specification is part of a statewide contract opportunity open to eligible purchasers within the State of Washington, including various counties, cities, and other local jurisdictions listed.

View the file

Other files

File Type Posted
00324_ExhibitA-1-Bidder'sCert.docx DOCX document
00324_ExhibitB-Specifications.docx DOCX document
00324_ExhibitA-2-Bidder'sProfile.docx DOCX document
00324_ExhibitC-Bid Price.xlsx XLSX spreadsheet
00324_ExhibitD-Contract.docx DOCX document
00324 SolAmd1 rev11122024.docx DOCX document
00324 Flares & Highway Signal Devices-PreBid.pptx PPTX presentation
00324_AMD1_ExhibitD-Contract_rev11122024.docx DOCX document
00324_CompetitiveSolicitation.docx DOCX document
00324 QandA1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

#00324 – Signal Igniter Flares and Highway Signal Devices

EXHIBIT B AMD1– SPECIFICATIONS

Note: This exhibit provides an overview of the Specifications for this Competitive Solicitation. This exhibit details mandatory commitments for the resulting contract. If Bidder is awarded a contract, this Exhibit B - Specifications will be incorporated into the resulting contract (as Exhibit A - Included Goods/Services). An awarded Bidder, (i.e., contractor) who is not able to meet such commitments throughout the contract term, will be subject to contract termination for breach of contract and damages. Please see Exhibit D – Contract.

1. SCOPE – Flares (Standard Laydown) All products meet Underwriter Laboratories 912 Specification.

2. SCOPE - Automatic Ignition Fusees (5, 10, 15, 20 & 30 Minute Fusees) And Manual Automatic Ignition Chamber (MICA)

This specification defines the requirement for the procurement by the State of Washington of (i) 5, 10, 15, 20, and 30 minute automatic ignition fusees/flares (SignalIgniter Flares) used as an emergency highway warning device for the purpose of diverting traffic on highways and informing moving vehicle traffic to stay out of hazardous traffic areas; and (ii) the manual automatic ignition chamber (MICA), which is affixed to a deployment tube designed and constructed by the State of Washington, or affiliates of the State of Washington such as Washington Department of Transportation (DOT), to deploy the SignalIgniter Flares. SignalIgniter Flares are primarily used by DOT, and may also be used by other State and Municipal agencies.

3. STANDARDS REFERENCED

Underwriter Laboratories Highway Emergency Signals, UL 912 for Fusees. While SignalIgniter Flares are not specifically referenced in UL 912, all product specifications and testing required by UL 912 shall apply to the SignalIgniter Flares except that the specialized cap used to ignite SignalIgniter Flares and unique deployment of SignalIgniter Flares renders certain sections of UL 912 non-applicable, including the following:

· Section 24.1. There is no “ignition by friction”.

· Section 25.1. The cap used on SignalIgniter Flares has different dimensions and functionality than the one on a regular flare/fusee.

· Section 25.2. The cap on SignalIgniter Flares is not intended to be removed nor does it form “a device for lighting the ignition composition by friction”. There is no “scratch surface” on a cap for SignalIgniter Flares.

· Section 25.3. The wire protruding through the cap on a SignalIgniter Flare directly contacts the ignition composition.

· Section 28.1. There is no “effort necessary to effect ignition” with a SignalIgniter Flare since ignition is achieved by electrical current heating the ignition wire protruding through the cap.

· Section 28.2. UL does not test the efficacy of the cap nor the MICA. There is no “striking” of the SignalIgniter Flare.

· Section 35.1. SignalIgniter Flares are not ignited in the same manner as manually ignited flares. As such, there is no need to state: “ALWAYS POINT FUSEE AWAY FROM FACE AND BODY WHILE IGNITING AND AFTERWARDS”. However, this language is not disqualifying and may be found on some SignalIgniter Flares due to requirements in other states.

4. REQUIREMENTS

SignalIgniter Flares are dropped from a slow moving DOT vehicle (DOT deployment guidelines shall specify the rate of speed of the deployment vehicle) onto pavement to mark hazardous traffic areas along the highway for the purpose of controlling and informing traffic to stay out of hazardous traffic areas. After the SignalIgniter Flare is manually pushed through the MICA, the SignalIgniter Flare must fall freely through the vertical drop tube and remain burning as it hits the deflector and rolls underneath the slow moving DOT vehicle. The ignited SignalIgniter Flare should roll toward the center of the traveled way and away from the vehicle’s tires. This creates a trail of burning SignalIgniter Flares marking the boundaries for hazardous traffic areas. The SignalIgniter Flare must be capable of burning on dry and wet road surfaces and burn for the minimum time set forth in Table 32.2 of UL 912. It is expressly understood that it is the sole responsibility of DOT and any other State or Municipal agencies that utilize SignalIgniter Flares or the MICA to ensure that the SignalIgniter Flares drop freely through the MICA and the vertical drop tube and then onto the road surface in the manner dictated by the deployment requirements created and enforced by the State of Washington, DOT, and any State or Municipal agencies.

The MICA is manufactured to the design specification attached hereto as Exhibit 3.0. DOT is solely responsible for the design and construction of the apparatus that incorporates the MICA and deploys the SignalIgniter Flares. This apparatus typically involves a drop tube, a deflector to guide the placement of the SignalIgniter Flare on the road surface, and the supports to hold the apparatus in place. Specifically, the MICA is connected to a vertically mounted drop tube securely mounted to a DOT vehicle. The SignalIgniter Flare shall ignite when it is pushed through the MICA that is connected to the vehicle’s 12-volt battery. This connection provides electrical current to a pair of conductive bars mounted within the inner wall of the MICA.

The flexible plastic wings attached to the SignalIgniter Flare cap are designed to cushion the impact of the SignalIgniter Flare with the road surface and to help bring the SignalIgniter Flare to rest on the roadway. The plastic wings burn away within approximately 45 seconds of ignition and are not a long-term anti-roll feature. Excessive speed by the vehicle deploying the SignalIgniter Flares will prevent the plastic wings from functioning as intended and the State of Washington and any State or Municipal agencies that utilize the MICA and SignalIgniter Flares, such as DOT, are solely responsible for developing deployment requirements that include speed and safe use limitations for SignalIgniter Flare deployment as well as the restrictions for use referenced in Section 5.0 of this Specification.

4.1Configuration: The SignalIgniter Flares shall conform to all requirements specified below.
(a)The base of the SignalIgniter Flare shall be closed by means of a disc or plug. Any additional outer plastic wrapping for waterproofing, which must be removed before the SignalIgniter Flare can be ignited, is not acceptable.
(b)The head of the SignalIgniter Flare shall be fully covered and protected with a tightly fitting cap with flexible wings and a secured wire extending symmetrical through the cap for ignition. The diameter of the cap shall be less than 1¼ inches. The entire rim of the SignalIgniter Flare head shall be free from ignition compound. The SignalIgniter Flare cap shall be configured to direct the hot ignition gases and flames downwards while minimizing any back-flame, which could pose a hazard to the user. The SignalIgniter Flare and cap shall be designed so that when the SignalIgniter Flare is ignited and dropped from a stationary height of 7 feet, it shall burn for the specified time as marked.
4.2Materials: All materials used in the manufacture of the SignalIgniter Flare shall be new and suitable for the use intended. SignalIgniter Flares shall not contain any Potassium Perchlorate.
4.3Workmanship: The workmanship shall be the highest grade throughout in accordance with the best standard practice for the type of product. The SignalIgniter Flare shall be free from defects that will affect safety, appearance, or serviceability.
4.4Special Markings / Requirements: In addition to markings required by UL 912, if applicable, each SignalIgniter Flare shall be marked with the date (month and year) of manufacture and, at a minimum, the following language:
CAUTION: PRODUCES HOT FLAME
Keep out of reach of children
For outdoor use only
Drop Fusee with igniter cap downward into MICA tube.
Make sure igniter cap wire contacts copper contacts of the MICA tube.
Insure lighted Fusee falls free and clear of the tube and vehicle.
5.PREPARATION FOR DELIVERY
5.1Packaging:

SignalIgniter Flares shall be prepared for shipment by common carrier in accordance with Federal Department of Transportation (Federal DOT) Regulations and shall be packaged in water resistant cartons of sufficient strength to permit reshipment without further reinforcement using industry packaging. The shipping carton shall meet Federal DOT Regulations and shall be stamped with the “Certificate of Box Maker”.

The cartons shall be stacked on pallets such that the Federal DOT hazardous material classification label can be viewed from all four (4) sides. All cartons on a single pallet must contain the same product, i.e. same item code number.

5.2 Marking

Each carton shall be marked with the date the lot was manufactured, commodity, quantity, size (duration, minutes), and the manufacturer’s name or brand name and shall be easily visible from all four (4) sides.

5.3 Storage

SignalIgniter Flares shall be stored in sealed bags away from flame and heat. Failure to store in a sealed bag will diminish performance. For maximum protection and performance, replace SignalIgniter Flares every three (3) years from date of purchase.

6 ACKNOWLEDGEMENTS AND AGREEMENTS

The State of Washington, and any State or Municipal agencies such as DOT that purchase SignalIgniter Flares or MICAs under the State contract, acknowledge the following and agree to develop, document, and enforce safe use requirements for deploying and utilizing SignalIgniter Flares. Such safe use requirements shall incorporate the following acknowledgements:

· The supplier of the SignalIgniter Flares and MICAs is only responsible for the quality of these products as set forth in this Specification. The State of Washington, including any State or Municipal agencies such as DOT that purchase SignalIgniter Flares or MICAs under the State contract, are responsible for safe use, deployment, and adherence to deployment requirements promulgated by such party. The supplier has no involvement, responsibility, or liability related to the development or enforcement of such requirements.

· SignalIgniter Flares produce an extremely hot flame and should only be deployed outdoors on pavement or other hard surfaces with curbs or other separation from combustible materials.

· Use of SignalIgniter Flares is prohibited near spilled fuel, fumes or combustible materials (e.g., leaves, grass, wood, refuse).

· Special care must be used if deploying SignalIgniter Flares in dry and/or high wind environments, and, in certain circumstances to be prescribed by DOT, SignalIgniter Flares should not be used if there is risk of wildfire.

· SignalIgniter Flares may emit sparks or molten ash that can start a fire if such sparks or ash contact combustible materials.

· SignalIgnite Flares that have been deployed require supervision until the burn process is complete to assure safety of roadway and the environment.

· SignalIgniter Flares, if contacted by moving vehicles such as following traffic, can travel significant distances and will ignite combustible materials if they contact combustible materials. Careful deployment and supervision is required.

· SignalIgniter Flares should be deployed at a slow rate of speed to assure that the SignalIgniter Flares are properly placed on the roadway and to assure that such flares come to rest where intended by the DOT crew deploying such flares.

· SignalIgniter Flares shall never be deployed manually and may only be deployed using the MICA and the deployment apparatus designed, installed, and approved by DOT.

Exhibit B AMD1– Specifications-#00324 Signal Igniter Flares And Highway Signal Devices Page 1 image1.png image2.png image3.png

File details come from the government source that posted it. Updated .