Lift Station Pump - Mohican State Park
Closed State & local contract opportunity Posted
- Solicitation number
- SRC0000030703
- State
- Ohio
- Responses due
Opportunity facts
- Jurisdiction
Opportunity details come from ohiobuys.ohio.gov. Updated .
About this opportunity
The Ohio Department of Natural Resources (ODNR), specifically Mohican State Park located in Ashland County, is soliciting bids for a specialized Hydromatic HPS4SCP023243 submersible solids handling pump. The procurement opportunity requires a precise lift station pump with specific technical specifications, including a 23HP 460V 60HZ 3-phase motor, 4" ANSI flange discharge, 6.13" impeller, and a 35-foot epoxy potted power cord. Delivery is mandated for June 24, 2025, directly to Mohican State Park at 3116 State Route 3, Loudonville, OH 44842. The evaluation criteria stipulate that the contract will be awarded to the lowest responsive and responsible bidder, determined by calculating the low lot total through multiplying unit costs by estimated usage. Potential bidders are strongly encouraged to conduct a site visit prior to submission, with Park Manager Jenny Roar (419-296-6528) available to coordinate site access and answer questions. The bid response is due by May 22, 2025, and substitutions to the specified pump model are not permitted.
No specific set-aside designations or restrictions for disadvantaged enterprises were explicitly mentioned in the procurement documents. The solicitation appears open to qualified vendors capable of meeting the highly technical pump specifications. While no incumbent vendor was identified, the procurement requires strict adherence to detailed technical requirements including specific material compositions like ASTM A48 Class 30 Cast Iron for castings, 416 Stainless Steel for shafts, and 440 Stainless Steel for impellers. Although a precise award value was not specified, the procurement is for a single pump with comprehensive technical requirements. The contract includes provisions that the park manager will coordinate delivery, approve craftsmanship and project quality before payment, and the pump must meet extensive electrical, mechanical, and operational standards including UL/FM approvals, premium efficiency motor specifications, and performance verification at 0270 GPM at 98 TDH.
Opportunity text
Needed Supply: Lift Station Pump Ordering Location and Address: Mohican State Park, 3116 State Route 3, Loudonville, OH 44842 Specifications Pump: Hydromatic HPS4SCP023243 with a 35 foot cord, spec sheet included Pump will need to be delivered by June 24, 2025. Substitutions not permitted. The park manager will coordinate the day and time of delivery. Park manager will approve craftsmanship and project quality prior to payment. A site visit is strongly encouraged. Product specifications include items such as: Submersible Solids Handling Pump - HPS Series
- Pump: Hydromatic HPS4SCP023243
- Impeller: 6.13"
- Discharge: Shall be 4" ANSI flange
- Motor: Shall be 23HP 460V 60HZ 3phase, oil filler design.
- Power Cord: Shall be epoxy potted and equipped with a minimum of 35' of power cord.
- Pump Operating Characteristics: Each pump shall be verified for performance. Pump shall operate at following conditions: 0270GPM at 98TDH
- Hydromatic® HPS series solids handling submersible sewage pump(s) as specified herein.
- Pump to be equipped with stainless steel nameplate, stating the unit is accepted for use in Standard Location or NEC® class 1, division 1, groups C, D hazardous locations with third party, Factory Mutual, approval.
- The pump shall be non-overloading throughout operation without employing service factor. The performance curve submitted for approval shall state in addition to head and capacity performance, the pump efficiency, and reflect motor service factor.
Construction:
- Castings - Cord Cap / Motor Housing / Bearing Housing / Seal Plate shall be ASTM A48 Class 30 Cast Iron.
- Shaft shall be 416 Stainless Steel.
- Impeller - ASTM B-584-836 440SST.
- Chopper Liner - ASTM B-584-836 440SST
- Fasteners / Hardware shall be 300 series Stainless Steel.
- Elastomers - O-Rings / Mechanical Seals / Cord Grip Grommets shall be Nitrile with optional Fluoropolymer Elastomer.
- Cartridge Seal shall be Carbon / Silicon Carbide.
- Power Cable shall be type SOOW or W while Control Cable shall be SOOW.
- Lifting Bail shall be welded or forged 300 Series Stainless.
Electrical Power Cord: The power cord will be SOOW or W, oil and water resistant 600v, 90C, UL® and CSA® approved and applied per NEC ampacities ratings at the cables rated temperature for intermittent / continuous duty. The pump shall be double protected with a compression fitting and an epoxy potted area that seals each conductor at the power cord entry to the pump. The power cable entry into the cord cap assembly shall first be made with a compression fitting. The leads shall be terminated within the epoxy and mechanically crimped to Teflon leads. This area of the cord cap shall then be filled with an epoxy compound potting. This assembly will prevent water contamination from gaining entry even in the event of wicking or capillary action. The power cord leads shall be connected to the motor leads with a terminal block or extra heavy connectors. The cord cap assembly where bolted to the motor housing shall be sealed with a Nitrile O-ring on a beveled edge to assure proper sealing. Wiring connection shall be done through a terminal block eliminating wire nuts or use of heavy duty crimp connectors. MOTOR: With exception of 208V models, motors shall meet premium efficiency in accordance with IEC 60034-30, level IE3, and NEMA MG1 [NEMA 12.60 Enclosed motor]. The motors are submerged in non-toxic, oil filled, cool running design providing significantly reduced operating temperatures. Pump designs requiring a secondary cooling apparatus shall be deemed unapproved and not equal. Air filled pump designs shall not be considered equal or approved.
- Motor will be of the squirrel-cage induction design, NEMA type A or B for 3 Phase [Per NEMA MG1 1.19] .
- The copper stator windings shall be insulated with moisture resistant Class H insulation materials, rated for 180˚C (356˚F) [Per NEMA MG1 1.66].
- The service factor shall be 1.15 for all models excluding the highest HP per frame size, which will be at 1.0. The motor shall have a voltage tolerance of +/- 10% from nominal, and a phase to phase voltage imbalance tolerance of 1%.
- The rotor bars and short circuit rings shall be made of cast aluminum.
- The maximum continuous temperature of the pumped liquid shall be 40˚C (104˚F). Each of the three phases will have a UL/FM approved thermostat or thermistor. The winding operating temperature at rated horsepower and service factor will be a maximum of 130˚C @ 40˚C ambient.
- The motor shall be capable of handling up to 15 evenly spaced starts per hour without overheating [Per NEMA].
- The rotors will have high efficiency laminated steel with die cast bars and shorting rings. The stators will have high efficiency laminated steel (if required to meet premium efficiency), with inverter duty rated, Class H magnet wire & insulation materials. Each of the three phases will have a UL/FM approved thermostat or thermistor set for 130˚C +/-5.
BEARINGS: The upper bearing shall be a heavy-duty radial single row ball bearing while the lower bearing shall be a double row heavy-duty angular contact ball bearing of the thrust limiting design. Minimum of 50,000 hours per ISO 281 bearing life for radial and thrust bearings at BEP. Bearing shall be lubricated for life from the factory and will be accomplished through the non-toxic, low viscous, dielectric oil in the frame. Pump designs requiring periodic scheduled bearing service shall not be considered equal or approved. Single row or sleeve lower bearings shall not be acceptable. Delivery: Mohican State Park, 3116 State Route 3, Loudonville, OH 44842. Contact Jenny Roar, Park Manager, 419-296-6528, jennifer.roar@dnr.ohio.gov Completion/Delivery Date: deadline of June 24, 2025. Evaluation. The contract will be awarded to the lowest responsive and responsible bidder as determined by the State. Contract Award. The contract will be awarded to the lowest responsive and responsible bidder by low lot total. Low lot total will be determined by multiplying the unit cost by the estimated usage listed in the bid and then adding each of the totals together to arrive at a total for all items. Failure to bid all items may result in the bidder being deemed not responsive. Site Visit & Point of Contact Prior to submitting a bid response, offerors are encouraged to visit the park. Please contact Jenny Roar, Park Manager, at 419-296-6528 or jennifer.roar@dnr.ohio.gov. Once a contract is awarded, failure of the bidder to have requested a site visit to become familiar with the facility and requirements of the bid will be insufficient reason to support any request to be released from the contract.