This is a Request for Quotes (RFQ) issued by the Ohio Department of Natural Resources (DNR) for Mohican State Park, seeking a specific Hydromatic lift station pump for delivery. The document requests bids for a Hydromatic HPS4SCP023243 submersible solids handling pump with a 35-foot cord, to be delivered to Mohican State Park located at 3116 State Route 3, Loudonville, OH by June 24, 2025. The Park Manager, Jenny Roar, encourages potential bidders to conduct a site visit prior to submitting a bid and will coordinate the specific delivery date and time. The contract will be awarded to the lowest responsive and responsible bidder, with the evaluation based on the low lot total determined by multiplying unit costs by estimated usage.
The RFQ provides detailed technical specifications for the pump, including requirements for construction materials, electrical power cord, motor characteristics, and bearings. Invoicing must be submitted directly to Ohio Shared Services (OSS) with specific documentation requirements, including the Purchase Order number, unique invoice number, and itemized charges. The document emphasizes that no State of Ohio sales tax should be applied, and the Purchase Order is valid only through June 30 of the contract year. Bidders are warned that failure to request a site visit will not be sufficient grounds to be released from the contract if awarded.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DAS Standard_T_C_3-31-25.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Needed Supply: Lift Station Pump
Ordering Location and Address: Mohican State Park, 3116 State Route 3, Loudonville, OH 44842
Project Background:
We are requesting bids for a new lift station pump at Mohican State Park, delivery only.
Specifications Pump: Hydromatic HPS4SCP023243 with a 35 foot cord, spec sheet included Pump will need to be delivered by June 24, 2025. Substitutions not permitted. The park manager will coordinate the day and time of delivery. Park manager will approve craftsmanship and project quality prior to payment. A site visit is strongly encouraged.
Product specifications include items such as:
Submersible Solids Handling Pump - HPS Series
• Pump: Hydromatic HPS4SCP023243
• Impeller: 6.13”
• Discharge: Shall be 4” ANSI flange
• Motor: Shall be 23HP 460V 60HZ 3phase, oil filler design.
• Power Cord: Shall be epoxy potted and equipped with a minimum of 35’ of power cord.
• Pump Operating Characteristics: Each pump shall be verified for performance.
Pump shall operate at following conditions: 0270GPM at 98TDH
• Hydromatic® HPS series solids handling submersible sewage pump(s) as specified herein.
• Pump to be equipped with stainless steel nameplate, stating the unit is accepted for use in Standard Location or NEC® class 1, division 1, groups C, D hazardous locations with third party, Factory Mutual, approval.
• The pump shall be non-overloading throughout operation without employing service factor. The performance curve submitted for approval shall state in addition to head and capacity performance, the pump efficiency, and reflect motor service factor.
Construction:
o Castings – Cord Cap / Motor Housing / Bearing Housing / Seal Plate shall be ASTM
A48 Class 30 Cast Iron.
o Shaft shall be 416 Stainless Steel.
o Impeller - ASTM B-584-836 440SST.
o Chopper Liner - ASTM B-584-836 440SST o Fasteners / Hardware shall be 300 series Stainless Steel.
o Elastomers – O-Rings / Mechanical Seals / Cord Grip Grommets shall be Nitrile with optional Fluoropolymer Elastomer.
o Cartridge Seal shall be Carbon / Silicon Carbide.
o Power Cable shall be type SOOW or W while Control Cable shall be SOOW.
o Lifting Bail shall be welded or forged 300 Series Stainless.
Electrical Power Cord:
The power cord will be SOOW or W, oil and water resistant 600v, 90C, UL® and CSA® approved and applied per NEC ampacities ratings at the cables rated temperature for intermittent / continuous duty. The pump shall be double protected with a compression fitting and an epoxy potted area that seals each conductor at the power cord entry to the pump. The power cable entry into the cord cap assembly shall first be made with a compression fitting. The leads shall be terminated within the epoxy and mechanically crimped to Teflon leads. This area of the cord cap shall then be filled with an epoxy compound potting. This assembly will prevent water contamination from gaining entry even in the event of wicking or capillary action. The power cord leads shall be connected to the motor leads with a terminal block or extra heavy connectors. The cord cap assembly where bolted to the motor housing shall be sealed with a Nitrile O-ring on a beveled edge to assure proper sealing. Wiring connection shall be done through a terminal block eliminating wire nuts or use of heavy duty crimp connectors.
MOTOR:
With exception of 208V models, motors shall meet premium efficiency in accordance with IEC 60034-30, level IE3, and NEMA MG1 [NEMA 12.60 Enclosed motor]. The motors are submerged in non-toxic, oil filled, cool running design providing significantly reduced operating temperatures. Pump designs requiring a secondary cooling apparatus shall be deemed unapproved and not equal. Air filled pump designs shall not be considered equal or approved.
• Motor will be of the squirrel-cage induction design, NEMA type A or B for 3 Phase [Per NEMA MG1 1.19] .
• The copper stator windings shall be insulated with moisture resistant Class H insulation materials, rated for 180˚C (356˚F) [Per NEMA MG1 1.66].
• The service factor shall be 1.15 for all models excluding the highest HP per frame size, which will be at 1.0. The motor shall have a voltage tolerance of +/- 10% from nominal, and a phase to phase voltage imbalance tolerance of 1%.
• The rotor bars and short circuit rings shall be made of cast aluminum.
• The maximum continuous temperature of the pumped liquid shall be 40˚C (104˚F).
Each of the three phases will have a UL/FM approved thermostat or thermistor. The winding operating temperature at rated horsepower and service factor will be a maximum of 130˚C @ 40˚C ambient.
• The motor shall be capable of handling up to 15 evenly spaced starts per hour without overheating [Per NEMA].
• The rotors will have high efficiency laminated steel with die cast bars and shorting rings. The stators will have high efficiency laminated steel (if required to meet premium efficiency), with inverter duty rated, Class H magnet wire & insulation materials. Each of the three phases will have a UL/FM approved thermostat or thermistor set for 130˚C +/-5.
BEARINGS:
The upper bearing shall be a heavy-duty radial single row ball bearing while the lower bearing shall be a double row heavy-duty angular contact ball bearing of the thrust limiting design. Minimum of 50,000 hours per ISO 281 bearing life for radial and thrust bearings at BEP. Bearing shall be lubricated for life from the factory and will be accomplished through the non-toxic, low viscous, dielectric oil in the frame. Pump designs requiring periodic scheduled bearing service shall not be considered equal or approved. Single row or sleeve lower bearings shall not be acceptable.
Delivery: Mohican State Park, 3116 State Route 3, Loudonville, OH 44842. Contact Jenny Roar, Park Manager, 419-296-6528, jennifer.roar@dnr.ohio.gov
Completion/Delivery Date: deadline of June 24, 2025.
Evaluation. The contract will be awarded to the lowest responsive and responsible bidder as determined by the State.
Contract Award. The contract will be awarded to the lowest responsive and responsible bidder by low lot total. Low lot total will be determined by multiplying the unit cost by the estimated usage listed in the bid and then adding each of the totals together to arrive at a total for all items. Failure to bid all items may result in the bidder being deemed not responsive.
mailto:jennifer.roar@dnr.ohio.gov
Site Visit & Point of Contact
Prior to submitting a bid response, offerors are encouraged to visit the park. Please contact Jenny Roar, Park Manager, at 419-296-6528 or jennifer.roar@dnr.ohio.gov.
Once a contract is awarded, failure of the bidder to have requested a site visit to become familiar with the facility and requirements of the bid will be insufficient reason to support any request to be released from the contract.
Bill to information: (OSS requirement)
Origin-DNR-418
All invoices must be submitted DIRECTLY to Ohio Shared Services (OSS).
-EMAIL the invoice to: invoices@ohio.gov -FAX the invoice to: 1-614-485-1039 -MAIL the invoice to: Ohio Shared Services, PO Box 182880, Columbus, Ohio 43218-
In order to process your invoice, please make sure all the required information listed below is on your invoice before submitting it to OSS or they will be returned for not being a proper invoice.
1. Must include the Purchase Order (PO) number assigned and Origin Number listed above
2. Supplier full name as it appears on your PO
3. The Ship to and/or service facility name and full address
4. Unique invoice number
5. Date of service or date work was completed.
6. Complete itemization of services performed, materials or goods supplied and/or labor furnished
7. Line charge(s). If parts are included, please break out lines with product and charges separately.
8. No State of Ohio sales tax
9. Remit to address must match our records for payment
10. This PO is only valid for the goods and/or services received through June 30, 20XX.
11. Any goods/services received after June 30, 20XX will require a new PO.
For the purchase of services use the following statement:
mailto:jennifer.roar@dnr.ohio.gov mailto:invoices@ohio.gov
The awarded supplier will be required to sign an Addendum to Bid Quote or Personal Services Agreement. Example attached. (remove this section if purchasing goods only)
File details come from the government source that posted it. Updated .