Eastern Oregon Correctional Institution Attic HVAC and Controls Upgrade
Open State & local contract opportunity Posted
- Solicitation number
- S-29100-00017086
- State
- Oregon
- Responses due
Opportunity facts
- UNSPSC codes
- 72121105 Shopping center and mall construction service
- 72141401 Detention facility construction service
- 95121604 Bus garage
- 95121607 Railway depot
- 95121605 Automotive repair or servicing building
- 95121711 Civic center
- 95121500 Commercial and entertainment buildings and structures
- 95121704 Prison building
- 95121503 Cafeteria
- 95121703 Court building
Show all 34
- 95121606 Railway station
- 95121701 Post office
- 72141400 Detention facility construction and repair services
- 72121104 Restaurant construction service
- 95121712 Art gallery
- 95121608 Underground railway station
- 95121501 Shopping mall
- 95121715 Public toilet facility
- 95121506 Theater
- 95121705 Fire station
- 72121100 Commercial and office building construction services
- 95121700 Public buildings and structures
- 72111104 New dormitory construction service
- 72111105 New hotel or motel construction service
- 72121101 Commercial and office building new construction service
- 72141128 Public square construction and or remodelling service
- 95121702 Police station
- 95121603 Bus station
- 95122106 Hostel
- 95121505 Shopping center
- 95121504 Shop building
- 95121714 Public changing room and shower facility
- 95121507 Market
- 95121706 Ambulance station
- Points of contact
Opportunity details come from oregonbuys.gov. Updated .
About this opportunity
The State of Oregon is soliciting sealed bids through Invitation to Bid 17086 for the attic HVAC and controls upgrade at Eastern Oregon Correctional Institution in Pendleton, Oregon, with bids due December 16, 2026. The ITB contains no disadvantaged business enterprise or other small business set-asides.
The scope covers upgrading 19 air handling units throughout the attic of the institution's main buildings. Work includes replacing the existing Delta Controls with BACnet controls, adding variable frequency drive fan motors, replacing the primary chilled water pump and distributed coil pumps, replacing pneumatic fail-safe damper actuators with electric actuators, retro-commissioning existing direct digital controls, adding new DDC points, and installing UV lighting in the duct system. Work must follow responsibility charts on the drawings and comply with the International Building Code, International Mechanical Code, ASHRAE standards, and the Oregon Energy Efficiency Specialty Code. Deliverables include as-built drawings, operation and maintenance manuals, and systems manuals with fold-out drawings in electronic formats.
Testing and balancing must be performed by a NEBB or AABC certified firm with a minimum of 10 years of experience. The Building Automation System contractor must be factory-authorized and factory-trained, with documented system compatibility for a minimum of 15 years and ongoing compatibility support for no less than 10 years. UV-C systems require four full days of onsite commissioning by a full-time certified manufacturer representative. Plans and specifications are posted as separate attachments.