Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24822R0102
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks design-build services to replace the facility main feeders at the San Juan VA Medical Center in Puerto Rico. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 is procuring these services to improve reliability and address condition issues of the existing electrical distribution system serving the medical center campus. The selected contractor will design and construct the replacement of all normal and standby power feeders from the main substation to existing substations. The period of performance is 730 calendar days from notice to proceed. Proposals are due by specified dates for the schematic design, design development, and construction document phases. Evaluation will consider technical qualifications, past performance, and price.

The solicitation is set aside 100% for service-disabled veteran-owned small businesses. The projected NAICS code is 237990 and PSC code R499. The opportunity is not identified as a recompete. The possible award value is unspecified but the scope includes replacing the facility's main feeders. Work will be performed at the San Juan VA Medical Center located in San Juan, Puerto Rico. A pre-proposal site visit was held and an amendment provided responses to offeror questions to clarify contract requirements.

Notice text

2 versions

Update #2 · Latest ·

Request for Information and Government Responses for Solicitation Number: 36C24822R0102

FY22 NRM TIER 2 (PROJ 672-22-604) DB Replace Facility Main Feeders at VACHS, San Juan,

PR 00921-3201:

Does the feeder s replacement include the grounding conductor also?

Government Responses:

Yes, the feeders consist of 3 live cables, including a ground conductor. The ground conductors need to be replaced also. The grounding conductor is essential part of the electrical system of the feeders, in accordance with Specification 26 05 13 Medium-Voltage Cables paragraph 1.2. located in page 1 of 11 pages as shown in referenced subparagraph A. Section 26 05 11 A and Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS: Requirements that apply to all sections of Division 26. Subparagraph B. Section 26 05 26, GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS: Requirements for personnel safety and to provide a low impedance path for possible ground fault currents. Also, this requirement is in provided Scope of Work (SOW), paragraph 2.f. located in page 10 of 90 pages: All electrical equipment and components associated with the feeder s replacement shall be furnished by D-B Team including new splices and miscellaneous electrical equipment if necessary.

The project will include the following, in accordance with the SOW, Section 2, paragraph a located in page 10 of 90 pages: Replacement of all normal power feeders form the main substation to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of each feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility.

Also, with the SOW, Section 2, paragraph d. Replacement of all standby power feeders from paralleling switch gear to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of the feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility and stand by power capability.

Update #1 ·

Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.

Files

Show all 17

Notice history

Notice Type Posted
Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. Award Award Notice
This notice Latest solicitation Solicitation
Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. NAICS 238210 Veterans Integrated Service Network 10 No set-aside
C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE Marion VA Medical Center Marion, Illinois 62959, United States · NAICS 541330 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
San Juan VAMC Construction Management Services San Juan, Puerto Rico 00921, United States · NAICS 541330 Department of Veterans Affairs Service-Disabled Veteran-Owned Small Business Sole Source
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC Pennsylvania 19104, United States · NAICS 236220 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
Z1DA--Design Build | NRM 654-27-130 | Eliminate Trip Hazards Facility Wide VASNHCS Department of Veterans Affairs VA Sierra Nevada Health Care System Reno, Nevada 89502, United States · NAICS 236220 Veterans Integrated Service Network 21 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors