Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24822R0102
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks design-build services to replace the facility main feeders at the San Juan VA Medical Center in Puerto Rico. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 is procuring these services to improve reliability and address condition issues of the existing electrical distribution system serving the medical center campus. The selected contractor will design and construct the replacement of all normal and standby power feeders from the main substation to existing substations. The period of performance is 730 calendar days from notice to proceed. Proposals are due by specified dates for the schematic design, design development, and construction document phases. Evaluation will consider technical qualifications, past performance, and price.
The solicitation is set aside 100% for service-disabled veteran-owned small businesses. The projected NAICS code is 237990 and PSC code R499. The opportunity is not identified as a recompete. The possible award value is unspecified but the scope includes replacing the facility's main feeders. Work will be performed at the San Juan VA Medical Center located in San Juan, Puerto Rico. A pre-proposal site visit was held and an amendment provided responses to offeror questions to clarify contract requirements.
Notice text
2 versions
Update #2 · Latest ·
Request for Information and Government Responses for Solicitation Number: 36C24822R0102
FY22 NRM TIER 2 (PROJ 672-22-604) DB Replace Facility Main Feeders at VACHS, San Juan,
PR 00921-3201:
Does the feeder s replacement include the grounding conductor also?
Government Responses:
Yes, the feeders consist of 3 live cables, including a ground conductor. The ground conductors need to be replaced also. The grounding conductor is essential part of the electrical system of the feeders, in accordance with Specification 26 05 13 Medium-Voltage Cables paragraph 1.2. located in page 1 of 11 pages as shown in referenced subparagraph A. Section 26 05 11 A and Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS: Requirements that apply to all sections of Division 26. Subparagraph B. Section 26 05 26, GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS: Requirements for personnel safety and to provide a low impedance path for possible ground fault currents. Also, this requirement is in provided Scope of Work (SOW), paragraph 2.f. located in page 10 of 90 pages: All electrical equipment and components associated with the feeder s replacement shall be furnished by D-B Team including new splices and miscellaneous electrical equipment if necessary.
The project will include the following, in accordance with the SOW, Section 2, paragraph a located in page 10 of 90 pages: Replacement of all normal power feeders form the main substation to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of each feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility.
Also, with the SOW, Section 2, paragraph d. Replacement of all standby power feeders from paralleling switch gear to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of the feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility and stand by power capability.
Update #1 ·
Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.
Files
Show all 17
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. | Award Notice | |
| This notice | Solicitation | |
| Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. | Veterans Integrated Service Network 10 | No set-aside | |
| C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| San Juan VAMC Construction Management Services | Department of Veterans Affairs | Service-Disabled Veteran-Owned Small Business Sole Source | |
| Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Design Build | NRM 654-27-130 | Eliminate Trip Hazards Facility Wide VASNHCS | Veterans Integrated Service Network 21 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity