Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC.

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C24822R0102
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs VA Caribbean Healthcare System San Juan, Puerto Rico 00931, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs intends to solicit proposals to replace all normal and standby power feeders at the San Juan VA Medical Center in Puerto Rico. Feeders will be replaced from the main substation to existing substations across the facility and rated at 15kV. Proposals are due by July 21, 2022 with work expected to be completed without disrupting facility operations. Evaluation will consider experience replacing similar electrical infrastructure for healthcare facilities. The solicitation number will be 36C24822R0102.

This opportunity is set aside exclusively for verified Service-Disabled Veteran-Owned Small Businesses. The construction value is estimated between $2-5 million. The contract is designated under NAICS 238210 - Electrical Contractors and Specialty Trade Contractors, with an anticipated period of performance between 12-18 months. Firms must be registered in SAM.gov and VIP vendor database by the response date.

Notice text

2 versions

Update #2 · Latest ·

DESCRIPTION

Date: 06/23/2022

Fiscal Year: 2022

Contracting Office Zip Code: 00921-3201

Service Code: Y2DZ

Contracting Office Address:

Department of Veterans Affairs

Network Contracting Office (NCO) 8

Construction Team 1

VA Adm. Bldg. Suite 4M440

10 Calle Casia

San Juan, PR 00921-3201

Subject: FY22 NRM TIER 2 (PROJ 672-22-604) DB Replace Facility Main Feeders at VACHS.

Proposed Solicitation Number: 36C24822R0102

DB Phase One Closing Response Date: 07/08/2022 at 04:30 PM AST

NCO-8 Contracting Officer is Rey F. Clemente, email: rey.clemente@va.gov

This requirement is set-aside for 100% Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

General Description:

The Department of Veteran Affairs (VA), Veterans Integrated Service Network (VISN) 8, at VA Caribbean Healthcare System, San Juan, Puerto Rico, and NCO-8 intends to issue a Design-Build project. The purpose of this project is for design and construction services for the replacement of all normal power feeders form the main substation to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of each feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility. Provide new feeder rated at 15KV from main substation to Admin Building substation on existing conduits. Feeder capacity will be same as the existing feeder that is currently in service. Provide new feeder rated at 15KV from main substation to Outpatient Addition (OPA) 2nd Floor substation. Feeder capacity will be same as the existing feeder that is currently in service. Replacement of all standby power feeders from paralleling switch gear to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of the feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility and stand by power capability.

Provide temporary power connection in case no spare conduits are available and there is no redundant feeder available. All electrical equipment and components associated with the feeder s replacement shall be furnished by D-B Team including new splices and miscellaneous electrical equipment if necessary. Perform an assessment of existing manholes to verify existing conditions. Provide necessary wire racks on manholes as required. Provide pest control for termites, roaches and other insects on manholes were required. The design-build contractor shall provide project management including the completion and delivery of all pertinent permits and applications. The design-build contractor shall provide Electrical design in accordance with applicable VA codes, standards, and specifications. All installation of electrical and civil components shall comply with VA, NFPA, and NEC 2020 requirements. The design-build contractor shall provide all testing required for wiring and electrical equipment installation including. Project location is at VA Caribbean Healthcare System, San Juan, PR.

The magnitude of construction is: Between $2,000,000.00 to $5,000,000.00, in accordance with VAAR 836.204 (f) (2).

The SOLICITATION will be issued on or about June 23, 2022.

SITE VISIT: Site Visit has been scheduled for Wednesday, 06/29/2022 at 10:00 AM AST. All Interested Offerors must meet VA Caribbean Healthcare System, Main Hospital Basement Room No. B-13, Engineering and Planning Sections (138) #10 Calle Casia, San Juan, PR 00921-3201. Only one (1) site visit has been scheduled for this project.

All information for this solicitation will be posted at GPE at SAM.gov.

All interested firms must be registered in the System for Award Management SAM.GOV and must be certified SDVOSB and verified in VIP at https://vetbiz.va.gov before the solicitation due date.

Update #1 ·

DESCRIPTION

Date: 06/08/2022

Fiscal Year: 2022

Contracting Office Zip Code: 00921-3201

Service Code: Y2DZ

Contracting Office Address:

Department of Veterans Affairs

Network Contracting Office (NCO) 8

Construction Team 1

VA Adm. Bldg. Suite 4M440

10 Calle Casia

San Juan, PR 00921-3201

Subject: FY22 NRM TIER 2 (PROJ 672-22-604) DB Replace Facility Main Feeders at VACHS.

Proposed Solicitation Number: 36C24822R0102

Closing Response Date: 07/21/2022 at 04:30 PM AST

NCO-8 POC is Rey F. Clemente, Contracting Officer email: rey.clemente@va.gov

This requirement is set-aside for 100% Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

General Description:

The Department of Veteran Affairs (VA), Veterans Integrated Service Network (VISN) 8, at VA Caribbean Healthcare System, San Juan, Puerto Rico, and NCO-8 intends to issue a Design-Build project. The purpose of this project is for design and construction services for the replacement of all normal power feeders form the main substation to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of each feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility. Provide new feeder rated at 15KV from main substation to Admin Building substation on existing conduits. Feeder capacity will be same as the existing feeder that is currently in service. Provide new feeder rated at 15KV from main substation to Outpatient Addition (OPA) 2nd Floor substation. Feeder capacity will be same as the existing feeder that is currently in service. Replacement of all standby power feeders from paralleling switch gear to all existing substations on the facility. New feeders shall be rated at 15 KV. Drawings are available for D/B Firm to verify route, length, and capacity of the feeder, but it is the responsibility of the D/B Firm to validate the information on them. Work shall be performed without interrupting normal operations of the facility and stand by power capability.

Provide temporary power connection in case no spare conduits are available and there is no redundant feeder available. All electrical equipment and components associated with the feeder s replacement shall be furnished by D-B Team including new splices and miscellaneous electrical equipment if necessary. Perform an assessment of existing manholes to verify existing conditions. Provide necessary wire racks on manholes as required. Provide pest control for termites, roaches and other insects on manholes were required. The design-build contractor shall provide project management including the completion and delivery of all pertinent permits and applications. The design-build contractor shall provide Electrical design in accordance with applicable VA codes, standards, and specifications. All installation of electrical and civil components shall comply with VA, NFPA, and NEC 2020 requirements. The design-build contractor shall provide all testing required for wiring and electrical equipment installation including. Project location is at VA Caribbean Healthcare System, San Juan, PR.

The magnitude of construction is: Between $2,000,000.00 to $5,000,000.00, in accordance with VAAR 836.204 (f) (2).

The SOLICITATION will be issued on or about JUNE 21, 2022.

All information for this solicitation will be posted at GPE at SAM.gov.

All interested firms must be registered in the System for Award Management SAM.GOV and must be certified SDVOSB and verified in VIP at https://vetbiz.va.gov before the solicitation due date.

Files

File Type Posted
36C24822R0102_2.docx DOCX document
36C24822R0102_1.docx DOCX document

Notice history

Notice Type Posted
Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. Award Award Notice
Z2DZ--FY22: NRM Tier 2 (PROJ: 672-22-604) DB - Replace Facility Main Feeders at San Juan VAMC. Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. NAICS 238210 Veterans Integrated Service Network 10 No set-aside
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC Pennsylvania 19104, United States · NAICS 236220 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE Marion VA Medical Center Marion, Illinois 62959, United States · NAICS 541330 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
San Juan VAMC Construction Management Services San Juan, Puerto Rico 00921, United States · NAICS 541330 Department of Veterans Affairs Service-Disabled Veteran-Owned Small Business Sole Source
Increase Emergency Power Rhode Island 02908, United States · NAICS 236220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors