Z2DA--BLDG 9 SERVER ROOM | 542-26-3-5240-0067 (VA-26-00065869) Split System/Back-Up System
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C24426Q0601
- Agency
-
Veterans Integrated Service Network 4
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Department of Veterans Affairs VA Medical Center Coatesville, PA 19320 U.S.A.
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 4 intends to solicit a split system and back-up air conditioning system installation at Building 9 Server Room, VA Medical Center, Coatesville, Pennsylvania, with quotations due June 18, 2026. This acquisition is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses certified under the SBA VETCERT program.
Work includes furnishing and installing one 5-ton Daikin split system with a 5-ton air handling unit and DC6 condensing unit (cooling range 0°F–115°F), one Daikin one-touch thermostat, required electrical work from panel to outdoor and indoor units, ductwork, one 4-ton Fujitsu mini-split condenser with wall mounts and 35-foot line sets, drain piping, refrigerant recovery from the existing unit, and removal and disposal of old equipment. All equipment will be programmed to maintain proper server room temperature. The estimated project cost is between $25,000 and $100,000. Work must be completed within 14 calendar days after Notice to Proceed. The VA intends to award a Firm Fixed Price contract under FAR Part 13 simplified procedures, contingent on FY26 fund availability.
An organized site visit is scheduled for May 28, 2026 at 10:00 AM EST at Building 70 Conference Room, VA Medical Center, 1400 Blackhorse Hill Road, Coatesville, Pennsylvania 19320; attendance is strongly encouraged. Prospective contractors must be registered in SAM.gov, maintain active VETCERT SDVOSB certification, and comply with VAAR 819.7003, OSHA, and EPA requirements. Written questions must be submitted by June 4, 2026 at 4:30 PM EST to Contracting Officer Elizabeth Wilson at Elizabeth.Wilson6@va.gov.
Notice text
Split System/Back-Up System for Building 9 Server Room
THIS OPPORTUNITY IS AVAILABLE ONLY TO SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES. Service-Disabled Veteran-Owned Businesses (SDVOSB) must be certified by The U.S. Small Business Administration Veteran Small Business Certification (VETCERT). This acquisition is conducted in accordance with FAR Part 13, Simplified Procedures for Noncommercial Acquisitions, Request for Quotation.
SCOPE: Split System/back up system (Mini-Split), the scope of work includes but limited to the following, full details are included in the solicitation:
To Furnish and Install one (1) 5T Daikin Split System (or equal to)
One 5T Air Handling Units.
One (1) 5T DC6 Condensing Unit with cooling operation range of 0F-115F
(unit will cool even in freezing temperatures to ensure the server room stays cool)
(1) Daikin one touch thermostat (or equal to)
Furnish and install required electrical from panel to ODU and AHU.
Furnish and install required ductwork.
Set on pad poured by CVMC (FES)
Set program once installed to proper settings needed to maintain correct temperature.
To Furnish Fujitsu (or equal to) 4T Mini-Split Condenser.
To furnish and install wall mounts.
To furnish and install line set of 35 feet.
To furnish and install communication line with one touch thermostat.
To Furnish wall hangers for the outside condenser unit.
Existing power available from old unit to hook back up.
To furnish drain piping for inside head unit to properly drain condensate out of building.
Set program on mini split to proper temperatures as need
Recover refrigerant from old mini split that is being replaced.
Remove old mini split and line set that being replaced.
Discard of old mini split of campus.
An organized site visit will be held on May 28, 2026, at 10:00 AM (EST). Contractors are to meet in Building 70 Conference Room at The Department of Veterans Affairs, VA Medical Center, 1400 Blackhorse Hill Road, Coatesville, PA 19320.
While the site visit is not mandatory, all bidders, suppliers and subcontractors are strongly encouraged to attend. All requests for information or questions regarding the solicitation must be submitted in writing to the Contracting Officer via electronic mail to the Contracting Officer, Elizabeth.Wilson6@va.gov no later than 4:30 PM EST, June 4, 2026. No telephone or fax requests will be honored
The magnitude of construction project for this procurement is between $25,000 and $100,000 and the North American Industry Classification System (NAICS) code is 238220 with a small business size standard of $19 million. Quotes are due by June 18, 2026, 3:00 PM via electronic mail to Elizabeth.Wilson6@va.gov
The Government contemplates award of a Firm Fixed Price contract resulting from this solicitation. Award of the contract is subject to the availability of FY26 funds. The maximum time for completion of the project is 14 calendar days after receipt of Notice to Proceed. To be considered for award, all prospective contractors MUST be registered in the System for Award Management (SAM) Database at www.sam.gov , MUST be in compliance with VAAR 819.7003 and meet the VETCERT SDVOSB certification requirements per https://veterans.certify.sba.gov/, and MUST meet OSHA/EPA requirements. For SDVOSB VETCERT certification guidelines, you may refer to https://veterans.certify.sba.gov/. To register in SAM, you may go online at https://www.sam.gov. For OSHA information, you may refer to www.osha.gov.
Files
| File | Type | Posted |
|---|---|---|
| 36C24426Q0601_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DA--mini split system for bldg 9 server room | 542-26-3-5240-0067 (VA-26-00065869) | Award Notice | |
| Z2DA--BLDG 9 SERVER ROOM | 542-26-3-5240-0067 (VA-26-00065869) Split System/Back-Up System | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--542-21-113 | Correct FCA Deficiencies – Repair Water Penetration | NCO 4 Construction East (VA-26-00020634) (VA-26-00020634) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity