Z2DA-- 589-19-503, Correct Deficiencies in BAS for Legionella Prevention (VA-20-00028966)

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C25520R0078
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Kansas City VA Medical Center 4801 Linwood Blvd. Kansas City MO 64128 USA

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice is seeking a contractor to correct deficiencies in the building automation system for Legionella prevention at the Kansas City VA Medical Center. The Department of Veterans Affairs, Veterans Integrated Service Network 15 will procure installation of approximately 120 new flow meters and 204 temperature sensors connected to an existing Schneider Electric EcoStruxure building automation system. The work will also include upgrading 22 universal network controllers to the newer Schneider Electric EcoStruxure control system through one-for-one replacement and reprogramming existing points and sequences. The solicitation will utilize a best value tradeoff source selection process and be set aside for Service-Disabled Veteran-Owned Small Businesses.

The NAICS code for this procurement is 236220 for commercial and institutional building construction, with a small business size standard of $39.5 million. The estimated cost range for the project is $2 million to $5 million and must be completed within 180 calendar days from the notice to proceed. The solicitation is expected to be available on May 18, 2020 with proposals due on June 26, 2020. An organized site visit will also be scheduled to allow interested offerors to inspect the premises.

Notice text

2 versions

Update #2 · Latest ·

The Department of Veterans Affairs, VISN 15 has a requirement to Correct Deficiencies in BAS for Legionella Prevention, Project Number 589-19-503, located at the Kansas City VA Medical Center, 4801 East Linwood Blvd Kansas City, MO 64128. The general scope of work for the Project: The following Narrative is intended to provide an overview of the scope of work of the proposed project at the Kansas City, MO VA Medical Center: OVERVIEW: The project involves placement of approximately 120 new flow meters and 204 temperature sensors to provide monitoring/alarm capabilities throughout the patient care areas of buildings 1, 26 and 56. The new meters and sensors will be connected to an existing Schneider Electric EcoStruxure BAS. Additionally, the project requires the upgrade of 22 Universal Network Controllers (UNCs) from the legacy controls to the newer Schneider Electric EcoStruxure Control system. The upgrade of the 22 UNCs will be limited to one for one replacement at the existing locations. Systems, points, and sequences programmed on the existing UNCs will be integrated and reprogrammed on the replacement Schneider Electric AS (Automation Servers) devices. The survey of the existing controllers and transfer of existing programming will be the responsibility of the control contractor. The electrical scope of work will consist of providing power needs of the new controls serving the added temperature sensors and associated BAS flow meters with power extended from existing or new electrical panelboards. Minimal patching and abatement to accomplish the project scope is required. The project requires fundamental Commissioning activities associated with the new controls serving the added temperature sensors and flow meters in the BAS. All work will be done under the review of the VA Commissioning Authority The Estimated project cost range to complete this work is between $2,000,000.00 and $5,000,000.00. Pursuant to 38 USC 8127(d) and in accordance with Public Law 109-461, the Veterans Benefits, Health Care and Information Technology Act of 2006, this construction project will be solicited as a Total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The North American Industry Classification Code (NAICS) for this procurement is 236220 (Commercial and Institutional Building Construction), with a small business size standard of $39.5 million. Contract Type: Firm Fixed. The duration of the project is estimated to be 180 calendar days from Notice to Proceed. This completion period includes final inspection and cleanup of the premises. Award will be made utilizing Best Value with Tradeoff Source Selection Process in accordance with Federal Acquisition Regulation Part 15. Proposal submission instructions will be included in the solicitation package. The government plans to award without discussions. The offeror is responsible to monitor and download any amendments from the Contract Opportunities (https://beta.sam.gov/) website, which may be issued to this solicitation. In accordance with FAR 52.204-7, Required SAM and in accordance with Veterans Affairs Acquisition Regulation (VAAR) 802.101, VetBiz Registration, prospective contractors must be registered in SAM and in the VetBiz databases under the applicable NAICS. Firms may obtain SAM information at http://www.sam.gov and VetBiz information at http://vetbiz.gov. The solicitation package with the specifications and drawings should be available for download on or about May 18, 2020 and the proposal due date will be on or about June 26, 2020. An organized site visit will be scheduled and specific date and time will be made available at time of solicitation issuance. Only one site visit will be scheduled and interested offerors are highly encouraged to attend. No hard copies of the solicitation or drawings will be provided; and telephone requests or questions will NOT be accepted. Please email requests or questions to David.Sterrett@va.gov and ensure that the subject line reads " Correct Deficiencies in BAS for Legionella Prevention, Project Number 589-19-503; Solicitation Number: 36C25520R0078.

Update #1 ·

The Department of Veterans Affairs, VISN 15 has a requirement to Correct Deficiencies in BAS for Legionella Prevention, Project Number 589-19-503, located at the Kansas City VA Medical Center, 4801 East Linwood Blvd Kansas City, MO 64128.

The general scope of work for the Project: The following Narrative is intended to provide an overview of the scope of work of the proposed project at the Kansas City, MO VA Medical Center:

OVERVIEW:

The project involves placement of approximately 120 new flow meters and 204 temperature sensors to provide monitoring/alarm capabilities throughout the patient care areas of buildings 1, 26 and 56. The new meters and sensors will be connected to an existing Schneider Electric EcoStruxure BAS. Additionally, the project requires the upgrade of 22 Universal Network Controllers (UNCs) from the legacy controls to the newer Schneider Electric EcoStruxure Control system. The upgrade of the 22 UNCs will be limited to one for one replacement at the existing locations. Systems, points, and sequences programmed on the existing UNCs will be integrated and reprogrammed on the replacement Schneider Electric AS (Automation Servers) devices. The survey of the existing controllers and transfer of existing programming will be the responsibility of the control contractor. The electrical scope of work will consist of providing power needs of the new controls serving the added temperature sensors and associated BAS flow meters with power extended from existing or new electrical panelboards. Minimal patching and abatement to accomplish the project scope is required.

The project requires fundamental Commissioning activities associated with the new controls serving the added temperature sensors and flow meters in the BAS. All work will be done under the review of the VA Commissioning Authority

The Estimated project cost range to complete this work is between $2,000,000.00 and $5,000,000.00.

Pursuant to 38 USC 8127(d) and in accordance with Public Law 109-461, the Veterans Benefits, Health Care and Information Technology Act of 2006, this construction project will be solicited as a Total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The North American Industry Classification Code (NAICS) for this procurement is 236220 (Commercial and Institutional Building Construction), with a small business size standard of $39.5 million. Contract Type: Firm Fixed. The duration of the project is estimated to be 180 calendar days from Notice to Proceed. This completion period includes final inspection and cleanup of the premises. Award will be made utilizing Best Value with Tradeoff Source Selection Process in accordance with Federal Acquisition Regulation Part 15. Proposal submission instructions will be included in the solicitation package. The government plans to award without discussions. The offeror is responsible to monitor and download any amendments from the Contract Opportunities (https://beta.sam.gov/) website, which may be issued to this solicitation. In accordance with FAR 52.204-7, Required SAM and in accordance with Veterans Affairs Acquisition Regulation (VAAR) 802.101, VetBiz Registration, prospective contractors must be registered in SAM and in the VetBiz databases under the applicable NAICS. Firms may obtain SAM information at http://www.sam.gov and VetBiz information at http://vetbiz.gov.

The solicitation package with the specifications and drawings should be available for download on or about May 18, 2020 and the proposal due date will be on or about June 26, 2020. An organized site visit will be scheduled and specific date and time will be made available at time of solicitation issuance. Only one site visit will be scheduled and interested offerors are highly encouraged to attend. No hard copies of the solicitation or drawings will be provided; and telephone requests or questions will NOT be accepted.

Please email requests or questions to David.Sterrett@va.gov and ensure that the subject line reads " Correct Deficiencies in BAS for Legionella Prevention, Project Number 589-19-503; Solicitation Number: 36C25520R0078.

Files

File Type Posted
36C25520R0078-000.docx DOCX document

Notice history

Notice Type Posted
Z2DA-- 589-19-503, Correct Deficiencies in BAS for Legionella Prevention (VA-20-00028966) Award Award Notice
Z2DA-- 589-19-503, Correct Deficiencies in BAS for Legionella Prevention (VA-20-00028966) Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z2DA--657-27-111JB, Install Continuous Water Monitoring System, JB- STL St. Louis MO 63125 · NAICS 236220 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System NAICS 238220 Veterans Integrated Service Network 20 No set-aside
Z2DA--cooling tower 2 and 3 repair Department of Veterans Affairs Vamc Baltimore MD 21201 · NAICS 236220 Veterans Integrated Service Network 5 Total Small Business
Y1DZ--replace chilled water pump at the boiler plant Department of Veterans Affairs Network Contracting Office 2 Bronx, New York 10468, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors