About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking construction services to repair fire and smoke doors at the VA Medical Center in Fayetteville, North Carolina under Project 565-25-101. The scope involves comprehensive door repairs, replacements, and re-certifications across Buildings 1 and 3, including work on doors with one-hour and two-hour fire ratings that requires specialized door technicians, electricians, wall finishers, and laborers. The project encompasses frame labeling and re-certification, complete door and frame replacements with new hardware including panic bars and card readers, demolition work requiring wall refinishing, and strict infection control measures throughout construction. Work must be performed primarily after normal working hours (1700-0700) to minimize disruption to medical facility operations, with frame labeling permitted during standard business hours. The solicitation deadline has been extended to July 28, 2025 at 11:00 AM EDT, with a mandatory site visit having been conducted on July 9, 2025.
This opportunity is set aside for Service-Disabled Veteran-Owned Small Business concerns under NAICS code 236220 for Commercial and Institutional Building Construction. The contractor must complete all construction within 150 calendar days of receiving the Notice to Proceed, allowing sufficient time for material submittals, procurement lead times, and actual construction work. Work locations span multiple floors in both buildings, from basement levels through the fourth floor, with considerable distances between door locations requiring careful project planning and coordination. The VA will provide temporary badging for contractor personnel and conduct bi-weekly progress meetings initially, transitioning to weekly meetings once material delivery schedules are established. All work must comply with VA specifications, design guides, infection control guidelines, and applicable building codes, with specific ICRA (Infection Control Risk Assessment) requirements varying by location and ranging from Level II to Level III precautions depending on the scope of work at each door location.
Notice text
2 versions
Update #2 · Latest ·
The purpose of this amendment is to provide Government responses to received questions for RFQ 36C24625Q0801, Repair Fire Doors, Project 565-25-101 for Fayetteville VA Medical Center.
Update #1 ·
STATEMENT OF WORK
Repair Fire Doors
Project: 565-25-101
Construction Services
VAMC Fayetteville, NC
SCOPE OF WORK: This project will repair fire and smoke doors located in Building nos. 1 and 3 at the VA Medical Center located at 2300 Ramsey Street, Fayetteville, NC 28301. The work will require door specialists, electricians, wall finishers, and laborers. It is highly recommended that all offerors attend the scheduled site visit walk through to note wall types, existing conditions, required hardware, take rough measurements, etc., necessary for proper offers.
Construction will be done in accordance with VA specifications, Design guides, Infection Control guidelines and all applicable codes. VA Standards shall be retrieved from the Office of Construction and Facilities Management website (https://www.cfm.va.gov/til/index.asp). Construction will also be structured to require minimum interruption of space function during construction.
The door numbers and work to be completed are as follows:
Building no. 1
Basement Floor
Room B39 (Soiled Linen) Two-hour fire rating. Provide frame label/re-certify.
Room B85 (Linen Chute) Two-hour fire rating. Provide frame label/re-certify.
Second Floor
Room 2055 (Anesthesia) One-hour fire rating. Provide door label/re-certify. Note that it is a new door and frame so the door label was likely covered by the continuous hinge.
Third Floor
Room 379 (Stairwell) - Two-hour fire rating. Provide frame label/re-certify. Add door sweep.
Fourth Floor
Room 419 (Soiled Utility) - One-hour fire rating. Provide frame and door labels/re-certify. Note that it is a new door and frame so the labels were likely covered by the continuous hinge.
Building no. 3
Basement Floor
Room B05 (Exterior) Two-hour fire rating. Demolition (see note below). Replace metal doors and frame for correct egress (outward). Install new closers, panic bars, lockset, vision lites (large in each door and above doors). Reconnect to maglock and card readers. The existing maglock is operational and works on a schedule. Replace all hardware. Replace ADO push plate on the exterior. On the interior side, replace ADO push plate with wave to open sensor. Provide new controllers. Reinstall air curtain. Install panic bars with egress out. Eliminate electric strike function. Storage function leverset. Install new threshold, weatherstripping, and sweeps.
Room B07 (Storage) Two-hour fire rating. Demolition (see note below). Replace wood doors and metal frame for correct egress (outward). Install new closers, panic bars, lockset/keypad.
Room B10 (Electrical) - Two-hour fire rating. Demolition (see note below). Replace metal door and frame. Install new closer and lockset.
Room 06L (Office) - Two-hour fire rating. Provide door and frame labels/re-certify.
Room B06P (Corridor) - Two-hour fire rating. Demolition (see note below). Replace metal doors and frame. Install lockset, panic bars, closers. Install wave to open sensors instead of ADO push buttons. Must maintain same level of security and automation.
First Floor
Room 105 (Storage) - Two-hour fire rating. Demolition (see note below). Replace metal door and frame. Install new closer, lockset and cylindrical deadbolt. Reinstall maglock and card reader.
Room 109 (Storage) - Two-hour fire rating. Provide frame label/re-certify.
Second Floor
Room 203B3 (Storage) - Two-hour fire rating. Replace wood door. Reinstall frame mounted door stop, add new closer and lockset. Dispose of door.
Located between Building nos. 1 and 3
Basement Floor
Door BX (exterior door to courtyard ramp) - Replace metal door and hardware located between buildings nos. 1 and 3. Install new metal door, rated sight glass, sweep, kick plates, maglock, card reader, door and wave to open sensor on the interior and ADO push plate on exterior.
Notes:
- Demolition entails removal and disposal. Includes destructive actions of parts of block, plaster and/or gypsum walls. Walls to be refinished to match existing walls. Infection control measures must be taken as directed by VA (assume plastic barriers, air scrubber, sticky mat, and covered carts).
- For the frame and door labels, they shall be metal (i.e., not a sticker).
- Panic bars shall be UL-Listed fire exit devices.
- Contractor to plan on doing one door at a time. The VA may consider allowing more than one door worked on at a time. For it to be considered, the contractor must have a well-developed plan and adequate personnel to complete the work as quickly as possible. Life safety (stairwell door, path of egress) will be scrutinized. There is considerable distance between each door location.
SCHEDULE: Contractor to complete construction within 150 calendar days of the Notice to Proceed. This should allow sufficient time for submittals and material lead times, as well as actual construction. WORKING HOURS: Frame labeling/re-certifying can happen during normal working hours (e.g., 0730-1700). Demolition and construction work shall be performed after normal working hours (e.g,. 1700-0700). COR may allow some exceptions if VA Safety and Infection Control offices allow (e.g., painting, finishing).
SCHEDULED SITE VISIT: This SOW doesn t contain all the necessary information for contractors to prepare proper offers. Therefore, the schedule site visit walk-through is highly recommended. There interested offerors are to record the wall types; take rough measurements; note existing door operators, hardware, etc.; observe surroundings and visualize necessary infection control measures. A VA Locksmith will be part of the site visit to assist in answering questions onsite.
BADGING: The VA will provide contractors temporary badging. All badges shall be returned to the VA.
MEETINGS: Bi-weekly progress meetings will follow the Notice to Proceed. Weekly meetings will commence once a materials delivery date is established.
ATTACHMENTS:
See attached document: Repair Fire Doors Project 565-25-101 Specifications.
See attached document: Repair Fire Doors Project 565-25 101 Photos of Doors.
(End Statement of Work)
Attachments
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--Repair Fire Doors - Construction Project #565-25-101 | Award Notice | |
| Z1DA--Repair Fire Doors - Construction Project #565-25-101 | Solicitation | |
| Z1DA--Repair Fire Doors - Construction Project #565-25-101 | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity