Z1DA--650-CSI-3516 Renovate Upgrade Angio OR Suite Construction

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24124R0065
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs (VA) Veterans Health Administration, Veterans Integrated Service Network 1 is seeking proposals for the renovation and upgrade of the Angiography Operating Room (Angio OR) Suite at the Providence VA Medical Center in Providence, Rhode Island. The project involves demolition, construction, and installation work to update the existing Angio OR suite. Key requirements include providing a new uninterruptible power supply system, installing warning lights, and coordinating utility disruptions. Proposals will be evaluated based on specialized experience, technical approach, and past performance, with specialized experience and past performance being the most important factors. Proposals are due by October 7, 2024.

This is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside contract with an estimated construction magnitude between $1,000,000 and $5,000,000. The North American Industry Classification System (NAICS) code is 236220 - Commercial and Institutional Building Construction. The period of performance is 240 calendar days from the notice to proceed. The solicitation number is 36C24124R0065.

Notice text

9 versions

Update #9 · Latest ·

The purpose of this Amendment is to incorporate the following into the solicitation:

To extend the proposal due date to Monday, October 7th, 2024 by 1:00PM EST.

To incorporate verbiage into the Proposal Evaluation Factors section of the solicitation. The verbiage incorporated is as follows:

The evaluation factors consist of Specialized Experience, Technical Approach, and Past Performance. The evaluation factors and subfactors are listed in order of relative importance. Specialized Experienced is the most important factor. Technical Approach is the second most important factor. Past Performance is the third most important factor. Specialized Experience and Past Performance, when combined, may outweigh Specialized Experience, depending on how severe the discrepancies are, or how low the overall score is.

Update #8 ·

See Attachment

Update #7 ·

SEE ATTACHMENT:

Update #6 ·

AMENDMENT A0005 QUESTIONS AND ANSWERS (WITH 3 ATTACHMENTS)

Vertiv/Liebert no longer offers the MMD12E nominal 1 ton system. We are told they do offer a nominal 1.5-ton MMD18E unit. We are also told that this system is not available with EC fans or variable capacity compressors. We are also told that this system would use R407C refrigerant. Please confirm if a revised schedule will be sent. Answer: Model MMD18E with constant speed is acceptable. Revised mechanical and electrical schedules will be provided.

Please provide a lighting / lighting controls spec. One was not provided. Answer: Lighting specification 26 51 00 will be provided. Lighting controls will be manual dimmers. Manual dimmers are specified in 26 27 26 Wiring Devices.

On drawing EL101, there are two symbols titled SLC . What exactly are these? Please provide information. Answer: SLC is a Surgical Lighting Controller. Boom mounted lights typically have (and are supplied with) a specialty controller. The drawings show providing the connection to the Surgical Lighting Controllers for these lights.

Update #5 ·

Amendment A0004, Questions and Answers (1-4).

Will the VA provide a dedicated laydown area for the contractor inside the space? The Contractor will have control of the limits of work as outlined in the construction documents. Additional storage space within the medical center will not be provided.

2. Will the VA provide a laydown area outside for a construction trailer and storage container? There is no guarantee space will be available for construction trailer or storage container. Coordinate with COR to determine if space is available at time of award.

3. Please provide any special instructions for demolition of existing equipment. Demolition shall comply with the contract documents

4. Please confirm Procore can be used on the job. The VA takes no exception to the use of Procore by the construction contractor.

_______End of Questions and Answers______

Update #4 ·

See Amendment A0003 SF30-Attachment S02 EXHIBIT A FACTOR 1 INFORMATION SHEET-R2

Update #3 ·

See Amendment A0002 SF30-Attachment S02 EXHIBIT A FACTOR 1 INFORMATION SHEET

Update #2 ·

See Amendment A0002 SF30

Update #1 ·

See attached RFP

Files

File Type Posted
36C24124R0065 0008.docx DOCX document
36C24124R0065 0007.docx DOCX document
WAGE RATES RI20240001 MOD 14 09202024 SAM.gov.pdf PDF
S04 650-CSI-351 Sign In_1SITE VISIT.pdf PDF
36C24124R0065 0006.docx DOCX document
E501-PreBidRevisions.pdf PDF
M-601-PreBidRevisions.pdf PDF
26 51 00.docx DOCX document
36C24124R0065 0005.docx DOCX document
36C24124R0065 0004.docx DOCX document
36C24124R0065 0003.docx DOCX document
S02 EXHIBIT A FACTOR 1 INFORMATION SHEET-R2.docx DOCX document
S02 EXHIBIT A FACTOR 1 INFORMATION SHEET.pdf PDF
36C24124R0065 0002.docx DOCX document
S02 EXHIBIT G ITEMIZED COST BREAKDOWN SHEET 650-CSI-351.pdf PDF
S02 EXHIBIT F WAGE DETERMINATION R120240001 MOD 12 08232024.pdf PDF
36C24124R0065 0001.docx DOCX document
S02 EXHIBIT I 9766_Providence_Angio_Rev1_UPS-24-07-12.pdf PDF
S02 EXHIBIT E VAAR Clause 852.219-77 Certificate of Compliance.pdf PDF
S02 EXHIBIT D Statement of Proposed Items_Aknowl of Amendments_Calculation Sheet.pdf PDF
Directive 7715_1_D_2023-06-22.pdf PDF
650-CSI-351-BidSpecs-Vol1-Reno UpgradeAngioOR-ProvidenceVAMC-TMM2123.pdf PDF
S02 EXHIBIT A Past Performance Info Sheet for Contractors.docx DOCX document
S02 EXHIBIT C Past Performance Questionnaire.pdf PDF
S02 EXHIBIT B Subcontractor Information and Consent Form.pdf PDF
Full Set Combined Drwgs.pdf PDF
650-CSI-351-BidSpecs-Vol2-Reno UpgradeAngioOR-ProvidenceVAMC-TMM2123.pdf PDF
36C24124R0065.docx DOCX document
S02 EXHIBIT H 263353 SPECS UPS.pdf PDF
S02 EXHIBIT G ITEMIZED COST BREAKDOWN SHEET 650-CSI-351.docx DOCX document
S02 EXHIBIT F WAGE DETERMINATION RI20240001 MOD 11 07122024.pdf PDF
Show all 31

Notice history

Notice Type Posted
Z1DA--650-CSI-351 Renovate Upgrade Angio OR Suite Construction Award Award Notice
This notice Latest solicitation Solicitation
Z1DA--650-CSI-3516 Renovate Upgrade Angio OR Suite Construction Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z2DA--523A4-CSI-288 3. 0T MRI Site Prep - Design Build West Roxbury VA Medical Center (VAMC_ West Roxbury, MA West Roxbury Vamc West Roxbury, MA 02132, United States · NAICS 236220 VA Technology Acquisition Center Service-Disabled Veteran-Owned Small Business
Expand 111 OR Department 2AS Phase 1 - Construction - Milwaukee, WI - Project:695-501 Milwaukee, Wisconsin 53295, United States · NAICS 236220 VA Technology Acquisition Center Service-Disabled Veteran-Owned Small Business
Z2DA--561-26-104 Repair Operating Room (OR) & Bathroom Leaks Department of Veterans Affairs East Orange NJ 07018 · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Z2DA--Project: 459-27-004 ACC MOD 2 Renovation VA Pacific Islands Health Care System Spark M. Matsunaga Department of Veterans Affairs Honolulu Hawaii 96819 · NAICS 236220 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
Z2DA--692-26-201 Refresh Halls and Walls throughout Campus White City Oregon 97503 · NAICS 236220 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors