Z1DA--36C261-24-AP-0122 | 654-24-1-6035-0001 | project 654-24-006 Circuit Breaker and Feeder Testing | 654

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C26124Q0160
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks testing services for 654 circuit breakers and feeders located at a Veterans Affairs medical center facility in Reno, Nevada. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 is soliciting these services under solicitation number 36C26124Q0160. The contractor must test electrical distribution system components, provide standard and infrared photographs, perform functional tests and exercise circuit breakers, affix labels, torque connections, and clean electrical connections. The contractor is also required to perform an overcurrent protective device coordination study and arc flash hazard analysis with new labels. Responses are due by January 10, 2024.

This procurement has been set aside 100% for small business. The place of performance is the VA medical center facility in Reno, Nevada. The period of performance is 30 days with testing to occur off-hours and photography on-hours. The contractor must have experience, licenses, safety training and certifications required to perform this type of electrical testing.

Notice text

3 versions

Update #3 · Latest ·

Request For Information (RFI) Responses

Project: VASNHCS Circuit Breaker & Feeder Testing

Project ID: 654-24-006

Solicitation ID: 36C26124Q0160

RFI # 1

Question: Has any of these underrated components outlined in the 2021 report been replaced with adequate ratings?

Answer: Issues from 2021 testing are known and have been repaired.

RFI # 2

Question: If VA Sierra Nevada Health Care Center is aware of the above-highlighted concerns and has developed the plans for isolation, we request you share them with us. If you don t have isolation plans, we suggest including in this bid to develop the equipment isolation plans in consultation with you.

Answer: Upon an instance in which a breaker fails testing, the VA representative shall be notified immediately, and VA will be responsible for the repairs. If the repairs can not be made immediately, the VA will be responsible for isolation of the branch circuit.

RFI # 3

Question: If the underrated components outlined in the 2021 report have not been upgraded, we suggest VA Sierra Nevada Health Care include in this scope to study & recommend alternate mitigation plans to overcome the rating bottlenecks. Generally, these measures involve tripping upstream or high-voltage circuit breakers that take out of service large load areas in addition to the faulted circuit.

Answer: Prior to testing work, a schedule for shutdowns will be established with the VA and contractor.

Update #2 ·

Request For Information (RFI) Responses

Project: VASNHCS Circuit Breaker & Feeder Testing

Project ID: 654-24-006

Solicitation ID: 36C26124Q0160

RFI # 1

Question: Will the testing under this contract be performed one time per the POP in CLIN 0001 or will it be performed more? Please clarify how often the testing will be performed under the contract.

Answer: For this contract breaker testing will be performed one time.

RFI # 2

Question: I see that Neta certifications are required. Am I able to secure this contract using my techs that have their Neta 2 certification, as well as my Electrical Engineering Degree?

Answer: The NETA 2 certification is for the testing of equipment. It only needs to be held by the Technicians that will be performing the testing. Supervisors, Project managers, etc. that are not performing the testing do not need the NETA certification.

RFI # 3

Question: Could you please provide a table of existing system model statistics?

Answer: Please see two PDF attachments to this amendment: See 9/17/2021 reports from ERS ref. #1072260. See 9/27/2021 report from ERS ref #1072260.

Update #1 ·

End of Solicitation.

Files

Show all 11

Notice history

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--Triennial Circuit Breaker and Feeder Testing Reno, Nevada 89502, United States · NAICS 238210 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
36-Month Electrical Distribution Testing Georgia 30033, United States · NAICS 221122 Veterans Integrated Service Network 7 Service-Disabled Veteran-Owned Small Business
J061--electrical testing (pre-solicitation) Department of Veterans Affairs Hampton VA Medical Center Hampton, Virginia 23667, United States · NAICS 238210 Veterans Integrated Service Network 6 Total Small Business
J059--FY27 Electrical Test and Calibrations Department of Veterans Affairs Syracuse VA Medical Center Syracuse NY 13210 · NAICS 238210 Veterans Integrated Service Network 2 No set-aside
657A5-26-111, Triennial Electrical Testing Marion, Illinois 62959, United States · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business Sole Source

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors