Y1DZ--Boiler Plant west Los Angeles

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C10F24R0018
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
11301 Wilshire Blvd Los Angeles ca 90073

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks information from small businesses for a potential construction project at the West Los Angeles VA Medical Center. The Department of Veterans Affairs plans to replace an aging boiler plant facility with a new two-story structure of approximately 11,957 square feet. Responses are requested by February 6, 2024 and must include company information, small business status and certifications, as well as experience with similar sized and complex construction projects valued between $20-50 million. Responses will be evaluated based on a capability statement not exceeding five pages demonstrating the ability to complete the required work.

There is no set-aside designated for this procurement. The NAICS code is 236220 for small construction businesses with a size standard of $45 million or less. Responses should indicate experience with single contract bonding up to the project's estimated value of $20-50 million. No incumbent or current contractors were named. Key details include replacing an existing boiler plant with a new two-story facility encompassing 11,957 square feet to service the medical center's south and north campuses.

Notice text

Description: The Department of Veterans Affairs is looking for small business firm and firms that are classified under one or more of the following:

SBA programs:

SDVOSB, and/or VOSB,

8(a),

HUBZone,

SDB,

WOSB, and small business.

The firm must be a Construction Contractor with an approved NAICS Code 236220, Small Business Size Standard of $45 million.

This project is an upgrade by replacement (Seismic and Physical Security Compliance) of a Boiler plant on the South Campus of the West Los Angele VA Medical Center. This project consists of approximately 11,957 BGSF two story facility, including boilers, supporting mechanical equipment, plant operations room, storage, and administrative office serving the boiler demands for the south and administration office north campuses. To the west of the structure is an adjoining service yard with low CMU enclosure and ornamental metal fence. This provides a protected access to four (4) fuel oil tanks enclosed in concrete vaults located below the yard and incidental parking for service vehicles. Underground services include a utility tunnel stub-out, to allow a future connection to the future Critical Care Center (CCC) and Central Utility Plant (CUP), utility connections linking the facility to the existing CUP (B501), underground steam and condensate piping to B500, replacement and re-sloping of high pressure steam (HPS) piping within B500 pipe basement through the steam tunnels up to the existing Boiler (B295) on the north campus, and new condensate pump equipment within B295. The site utility scope also includes Boiler Plant s temporary transformer in a CMU enclosure located northeast of Fisher House with associated electrical duct banks/ feeds, telecommunications, and plumbing connection to the new boiler plant as well as a gas meter enclosure and associated underground piping and trenching. Other site scope associated with this project includes cast-in-place industrial water storage tank, fire water storage tank, and fuel oil storage tanks in a cast-in place concrete vault.

The estimated magnitude for this project is between $20M-$50M. ($20,000,000-$50,000,000). At this time, no solicitation exists; therefore, do not request a solicitation. Small Business Contractors and vendors having the skills and capabilities necessary to perform the stated requirements are invited to provide information to contribute to this market survey/sources sought.

Responses should include the following information:

1. Company Name,

2. Address,

3. Point of Contact,

4. Phone number and e-mail address,

5. Business size determination and qualifying Small Business status,

6. Certification of Small Business Status,

7. Construction Build experience of similar projects in size, complexity, and dollar amount plus single contract bonding maximum.

Respondents are requested to submit a Capability Statement that exhibits clear and convincing evidence of your firm's capabilities and experience to perform the listed tasks. The capability statement is not to exceed 5 pages. Please provide your responses by email (ONLY) by 2February 6, 2024 to Noella Bond, Contracting Officer, email address, noella.bond@va.gov. This sources sought notice is for market research purposes in accordance with Federal Acquisition Regulation (FAR) Part 10. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought. Small business concerns failing to respond to this ad will not be precluded from responding to the solicitation.

Note that this is not a Request for Proposal, and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents.

Telephone inquiries will not be returned. Point of Contact is Noella Bond, Contracting Officer, email noella.bond@va.gov.

Files

File Type Posted
36C10F24R0018.docx DOCX document

Notice history

Notice Type Posted
Y1DZ--Boiler Plant west Los Angeles Award Award Notice
Y1DZ--Boiler Plant West Los Angeles VA Medical Center Latest solicitation Solicitation
Y1DZ--Boiler Plant West Los Angeles VA Medical Center Pre-Solicitation
Y1DZ--Boiler Plant west Los Angeles Special Notice
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--FY27 NRM - Replace B98 and B88 Boiler and Sump Pumps Department of Veterans Affairs Va Northern California Health Care System McClellan Park CA 95652, United States · NAICS 236220 Veterans Integrated Service Network 21 No set-aside
Y1DZ--replace chilled water pump at the boiler plant Department of Veterans Affairs Network Contracting Office 2 Bronx, New York 10468, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) Veterans Affairs Illiana Healthcare System -Vaihcs Danville, Illinois 61832, United States · NAICS 236220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) Veterans Affiars Medical Center Durham NC 27705 · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity