The Department of Veterans Affairs (VA) Veterans Health Administration is seeking a Service-Disabled Veteran-Owned Small Business (SDVOSB) to install a comprehensive fire suppression system at Building 16 of the American Lake VA Medical Center in Lakewood, Washington. The project requires implementing both wet and dry fire suppression systems across approximately 6,000 gross square feet, including back-flow prevention devices, position indicator valves, a two-inch isolation valve on the main potable water service line, and a Fire Department Connection (FDC) point. Additional work will involve asbestos and lead paint abatement. The solicitation will be evaluated using the best value continuum method described in FAR Part 15.101, with an anticipated Request for Proposals (RFP) to be posted no later than April 28, 2025. Interested contractors must be registered in the System for Award Management (SAM) and submit a bid bond of at least 20% of the bid price, not exceeding $3 million.

The contract is 100% set-aside exclusively for Service-Disabled Veteran-Owned Small Businesses, with the project classified under NAICS code 237110 and a size standard of $45 million. The total project magnitude is estimated between $1,000,000 and $5,000,000, with a planned period of performance of 249 calendar days from the Notice to Proceed. Potential contractors will need to comply with VA safety and infection control policies, complete OSHA safety training, and ensure proper handling of hazardous materials. The solicitation requires compatibility with existing building automation systems and adherence to NFPA 13 (2022 edition) standards for sprinkler system installation. All solicitation documents, including specifications and drawings, can be accessed by searching Solicitation 36C26025R0053 on SAM.gov, with the response deadline set for April 27, 2025.

Notice text

2 versions

Update #2 · Latest ·

663A4-22-202 INSTALL SPRINKLER AND WATER MAIN CONNECTION BLDG.16 AMERICAN LAKE VA MEDICAL CENTER 9600 Veterans Dr SW, Joint Base Lewis-McChord, WA 98493 Procurement Number: 36C26024R0044 This is a pre-solicitation notice synopsizing an upcoming competitive solicitation satisfying the requirements of FAR 5.201 and FAR 5.203. An invitation for Request for Proposals (RFP) is anticipated to be posted no later than April 28, 2025. The VA Medical Center American Lake Campus located in Lakewood, WA, has a requirement for a Firmed Fixed Price construction project that requires a general contractor to provide a wet fire suppression system for the occupied floors of the structure (Covered Patio, 1st and 2nd) and a dry fire suppression system for the unoccupied areas of the facility excluding crawl space. The new system shall provide an adequate back-flow prevention devices, position indicator valve, associated fittings, the addition of a two-inch isolation valve to the buildings main potable water service line, Fire Department Connection (FDC) point, and associated support as details are provided in the attached Drawings and Specs. Work will include asbestos and lead paint abatement. The new fire suppression system will be servicing approximately 6,000GSF spaces in Building 16. The magnitude of this project is between $500,000 and $1,000,000. The NAICS code for this procurement is 237110 and the size standard is $45 million. The solicitation is being issued in the best value continuum described in FAR Part 15.101. A bid bond is required, and the bid guarantee amount shall be at least 20 percent of the bid price but shall not exceed $3 million. This project is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. All relevant solicitation documents, including specifications and drawings, may be accessed for download on the date of issue by conducting a search of Solicitation 36C26025R0053 on https://sam.gov/content/opportunities under Contract Opportunities. Any amendments to the solicitation will be posted solely to this website. It is the responsibility of the offeror to verify the number of amendments issued. All offerors must be registered in the System for Award Management (SAM) and listed there as an SDVOSB: https://www.sam.gov/SAM/ See attached document: SOW Construction 663A4-22-202 rev1.doc See attached document: 663A4-22-202 Drawings.pdf See attached document: 663A4-22-202 Specifications.pdf

Update #1 ·

663A4-22-202 INSTALL SPRINKLER AND WATER MAIN CONNECTION BLDG.16

AMERICAN LAKE VA MEDICAL CENTER

9600 Veterans Dr SW, Joint Base Lewis-McChord, WA 98493

Procurement Number: 36C26024R0044

This is a pre-solicitation notice synopsizing an upcoming competitive solicitation satisfying the requirements of FAR 5.201 and FAR 5.203. An invitation for Request for Proposals (RFP) is anticipated to be posted no later than April 28, 2025. The VA Medical Center American Lake Campus located in Lakewood, WA, has a requirement for a Firmed Fixed Price construction project that requires a general contractor to provide a wet fire suppression system for the occupied floors of the structure (Covered Patio, 1st and 2nd) and a dry fire suppression system for the unoccupied areas of the facility excluding crawl space. The new system shall provide an adequate back-flow prevention devices, position indicator valve, associated fittings, the addition of a two-inch isolation valve to the buildings main potable water service line, Fire Department Connection (FDC) point, and associated support as details are provided in the attached Drawings and Specs. Work will include asbestos and lead paint abatement.

The new fire suppression system will be servicing approximately 6,000GSF spaces in Building 16.

The magnitude of this project is between $1,000,000 and $5,000,000. The NAICS code for this procurement is 237110 and the size standard is $45 million. The solicitation is being issued in the best value continuum described in FAR Part 15.101. A bid bond is required, and the bid guarantee amount shall be at least 20 percent of the bid price but shall not exceed $3 million. This project is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses.

All relevant solicitation documents, including specifications and drawings, may be accessed for download on the date of issue by conducting a search of Solicitation 36C26025R0053 on https://sam.gov/content/opportunities under Contract Opportunities. Any amendments to the solicitation will be posted solely to this website. It is the responsibility of the offeror to verify the number of amendments issued.

All offerors must be registered in the System for Award Management (SAM) and listed there as an SDVOSB: https://www.sam.gov/SAM/

See attached document: SOW Construction 663A4-22-202 rev1.doc

See attached document: 663A4-22-202 Drawings.pdf

See attached document: 663A4-22-202 Specifications.pdf

Files

File Type Posted
36C26025R0053 Presolicitation.docx DOCX document
36C26025R0053 Presolicitation.docx DOCX document
663A4-22-202 Specifications.pdf PDF
SOW Construction 663A4-22-202 rev1.docx DOCX document
663A4-22-202 Drawings.pdf PDF

Notice history

Notice Type Posted
Y1DA--663A4-22-202 | AMLK Install Sprinkler and Water Main Connection to Building 16 Award Award Notice
Y1DA--663A4-22-202 AMLK Install Sprinkler and Water Main Connection to Building 16 Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC Department of Veterans Affairs Franklin D. Roosevelt VA Medical Center Montrose, New York 10548, United States · NAICS 238210 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System NAICS 238220 Veterans Integrated Service Network 20 No set-aside
Z1DA--Upgrade Fire Alarm System Construction 676-22-110 Tomah, Wisconsin 54660, United States · NAICS 238210 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Y1DZ--598-22-115 Site Utility Infrastructure-NLR Eugene J. Towbin VA Healthcare Center North Little Rock AR 72114, United States · NAICS 237110 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors