36C26025R0053 Presolicitation.docx

DOCX document 24 KB Posted

Attached to
Y1DA--663A4-22-202 AMLK Install Sprinkler and Water Main Connection to Building 16
Solicitation number
36C26025R0053
Issued by

About this file

This is a Department of Veterans Affairs (VA) Pre-Solicitation Notice for a construction project at the American Lake VA Medical Center in Lakewood, Washington. The solicitation (36C26025R0053) seeks a Service-Disabled Veteran-Owned Small Business (SDVOSB) to install a comprehensive fire suppression system in Building 16, which involves implementing both wet and dry fire suppression systems across approximately 6,000 gross square feet. The project requires installing back-flow prevention devices, position indicator valves, a two-inch isolation valve on the main potable water service line, and a Fire Department Connection (FDC) point, with additional work including asbestos and lead paint abatement.

The project is valued between $500,000 and $1,000,000, with a 100% SDVOSB set-aside and will be evaluated using the best value continuum method. Interested contractors must be registered in the System for Award Management (SAM) as an SDVOSB and submit a bid bond of at least 20% of the bid price, not exceeding $3 million. The Request for Proposals (RFP) is anticipated to be posted no later than April 28, 2025, with a response deadline of April 27, 2025, at 15:00 Pacific Time. All solicitation documents, including specifications and drawings, can be accessed by searching Solicitation 36C26025R0053 on SAM.gov, with the NAICS code 237110 and a size standard of $45 million.

View the file

Other files

File Type Posted
36C26025R0053 Presolicitation.docx DOCX document
SOW Construction 663A4-22-202 rev1.docx DOCX document
663A4-22-202 Specifications.pdf PDF
663A4-22-202 Drawings.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
663A4-22-202 AMLK Install Sprinkler and Water Main Connection to Building 16

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
98661
SOLICITATION NUMBER*
36C26025R0053
RESPONSE DATE/TIME/ZONE
04-27-2025 15:00 PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
99 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
Y1DA
NAICS CODE*
237110
PLACE OF PERFORMANCE
American Lake VA Medical Center

9600 Veterans Dr SW

Lakewood WA

POSTAL CODE
98493
COUNTRY
USA

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
NCO 20 Network Contracting Office

ATTN: V4CONT

1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661

POINT OF CONTACT*

Stephen Slaby stephen.slaby@va.gov

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
stephen.slaby@va.gov

EMAIL DESCRIPTION

DESCRIPTION

663A4-22-202 INSTALL SPRINKLER AND WATER MAIN CONNECTION BLDG.16

AMERICAN LAKE VA MEDICAL CENTER

9600 Veterans Dr SW, Joint Base Lewis-McChord, WA 98493 Procurement Number: 36C26024R0044 This is a pre-solicitation notice synopsizing an upcoming competitive solicitation satisfying the requirements of FAR 5.201 and FAR 5.203. An invitation for Request for Proposals (RFP) is anticipated to be posted no later than April 28, 2025. The VA Medical Center American Lake Campus located in Lakewood, WA, has a requirement for a Firmed Fixed Price construction project that requires a general contractor to provide a wet fire suppression system for the occupied floors of the structure (Covered Patio, 1st and 2nd) and a dry fire suppression system for the unoccupied areas of the facility excluding crawl space. The new system shall provide an adequate back-flow prevention devices, position indicator valve, associated fittings, the addition of a two-inch isolation valve to the buildings main potable water service line, Fire Department Connection (FDC) point, and associated support as details are provided in the attached Drawings and Specs. Work will include asbestos and lead paint abatement.

The new fire suppression system will be servicing approximately 6,000GSF spaces in Building 16.

The magnitude of this project is between $500,000 and $1,000,000. The NAICS code for this procurement is 237110 and the size standard is $45 million. The solicitation is being issued in the best value continuum described in FAR Part 15.101. A bid bond is required, and the bid guarantee amount shall be at least 20 percent of the bid price but shall not exceed $3 million. This project is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses.

All relevant solicitation documents, including specifications and drawings, may be accessed for download on the date of issue by conducting a search of Solicitation 36C26025R0053 on https://sam.gov/content/opportunities under Contract Opportunities. Any amendments to the solicitation will be posted solely to this website. It is the responsibility of the offeror to verify the number of amendments issued.

All offerors must be registered in the System for Award Management (SAM) and listed there as an SDVOSB: https://www.sam.gov/SAM/ Attachments See attached document: SOW Construction 663A4-22-202 rev1.

See attached document: 663A4-22-202 Drawings.

See attached document: 663A4-22-202 Specifications.

*=Required Field
Presolicitation Notice

Presolicitation Notice

File details come from the government source that posted it. Updated .