Walk-In Refrigerator
Closed Special Notice Posted
- Solicitation number
- 36C24W25Q0218(updated)
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Place of performance
- Tulsa, Oklahoma 74127, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs has issued a Special Notice for the procurement of a walk-in refrigerator at the VA Medical Center in Tulsa, Oklahoma. This solicitation (36C24W25Q0218) has undergone six amendments since its initial posting, with the most recent amendment providing a revised Statement of Work and extending the submission deadline to September 5, 2025, at 12:00 PM. The procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses and falls under NAICS code 333415 for air-conditioning and refrigeration equipment manufacturing. The project involves designing, procuring, and installing a panel-by-panel assembled walk-in medical laboratory refrigerator on the second floor of the new Tulsa VA Medical Center. The solicitation is being managed by the VA Regional Procurement Office West located in McClellan Park, California.
The primary objective is to provide a specialized walk-in medical laboratory refrigerator for room 2A308F with a footprint of 9 feet 3 inches by 9 feet 9 inches, operating at a temperature set point of 2 degrees Celsius. Key technical requirements include air-cooled cooling systems with 100% compressor redundancy, stainless steel surfaces, LED lighting, and integration with the Building Automation System for comprehensive temperature monitoring and alarm capabilities. The contractor must provide complete installation services including electrical, plumbing, and HVAC connections, with delivery required after November 10, 2025, and full completion by January 30, 2026. Only Service-Disabled Veteran-Owned Small Business Concerns are eligible to participate in this procurement opportunity. The project includes strict requirements for healthcare facility compliance, infection control measures, and adherence to OSHA safety standards, with factory-trained personnel required for installation and an OSHA 30 certified professional must be on-site at all times during work.
Notice text
4 versions
Update #4 · Latest ·
NOTICE FOR REQUEST FOR QUOTE AMENDMENT
SOLICITATION NUMBER: 36C24W25Q0218
AMENDMENT NUMBER: 0006
DATE: August 29, 2025
PROJECT NUMBER: N/A
PROJECT TITLE: Walk-In Refrigerator
LOCATION: VA Medical Center, Tulsa, OK, 74127
REASON FOR AMENDMENT: Revised Statement of Work
______________________________________________________________________________
AMENDMENT: 0006
REVISED STATEMENT OF WORK IS ATTACHED
DUE DATE FOR OFFERS IS NOW SEPTEMBER 05, 2025 @12:00PM.
All other terms and conditions remain unchanged.
Update #3 ·
Amendment to a Previous Combined Solicitation
NOTICE FOR REQUEST FOR QUOTE AMENDMENT
SOLICITATION NUMBER: 36C24W25Q0218
AMENDMENT NUMBER: 0005
DATE: August 27, 2025
PROJECT NUMBER: N/A
PROJECT TITLE: Walk-in Refrigerator
LOCATION: VA Medical Center, Tulsa, OK, 74127
REASON FOR AMENDMENT: Extend the closing date
______________________________________________________________________ AMENDMENT: 0005
THE DUE DATE FOR OFFERS REMAINS AUGUST 29, 2025 @ 5:00PM.
____________________________________________________________________________
All other terms and conditions remain unchanged.
Update #2 ·
Amendment to a Previous Combined Solicitation
NOTICE FOR REQUEST FOR QUOTE AMENDMENT
SOLICITATION NUMBER: 36C24W25Q0218
AMENDMENT NUMBER: 0004
DATE: 08/12/2025
PROJECT NUMBER: N/A
PROJECT TITLE: Walk-In Refrigerator
LOCATION: VA Medical Center, Tulsa, OK, 74127
REASON FOR AMENDMENT: Location of Refrigerator, Condensing Unit
______________________________________________________________________ AMENDMENT: 0004
Question: 1 – Location of Refrigerator: I would like to bid on this project (36C24W25Q0218P003), but the attached drawings do not show me the dimensions of the walk-in refrigerator LxWxH and the desired temperature. Please let me know!
VA Response: Per the SOW and a previous RFI: There will be sheetrock on three sides, making a footprint of 9 foot 3 inches by 9 foot 9 inches (this will need to be verified by the contractor). The set point will be 2 degrees Celsius.
Question: 2 – Condensing Unit: How far is the condensing unit from the walk-in cooler?
VA Response: Per the SOW, the condensing unit is to be installed on top of the walk-in.
THE DUE DATE FOR OFFERS REMAINS UNCHANGED AUGUST 27, 2025.
All other terms and conditions remain unchanged.
Update #1 ·
AMENDMENT: 0003
DRAWINGS ARE ATTACHED
DUE DATE FOR OFFERS REMAINS AUGUST 21, 2025 @12:00PM.
All other terms and conditions remain unchange
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 4110--Walk In Coolers and Freezer Replacement and Installation | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| 36C25227Q0048 - coolers and freezer | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| J041--PMI ICE Machine Service Contract -w/wd, B+4, POP 1/1/2027 - 12/31/2027 | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| NTX - Preventive and Corrective Maintenance for Ice | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Remove and Replace Walkin Cooler and Freezer | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity