USCGC Healy Fire Alarm System troubleshooting
Closed Solicitation Posted
- Solicitation number
- 70Z08526Q0028041
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 336611 Ship Building and Repairing
- Place of performance
- Seattle, Washington 98134, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Homeland Security US Coast Guard seeks troubleshooting and repair of a SIEMENS fire alarm system aboard the USCGC Healy, with proposals due September 24, 2026. The procurement is set aside for total small business.
Place of performance is USCG Base Seattle, 1519 Alaskan Way S, Seattle, WA 98123, with point of contact LT Stephen Bruno. The contractor must be a Siemens technical representative capable of programming detector heads into the system. The period of performance is fourteen calendar days from contract award for three working days of on-site service.
The scope requires the contractor to provide all labor, materials, tools, and equipment to clear alarms and troubleshoot constant "Input source malfunction," "Not Responding," and "Communication Error" alarms on the FireFinder XLS Fire Alarm Control Panel, and reset all active alarms to normal operating state. The contractor must restore full capability to all fire alarm units except those in Generator Room 2 (1-80-2-E), program unidentified detector heads including recently installed HFP-11 smoke detectors in the Magazine Compartment (1-9-2-M), and conduct functional tests to verify proper activation and communication. The contractor must also inspect the Master Fire Alarm Control Panel in the Engineering Control Center and annunciators in Damage Control Central and Port and Starboard Quarterdecks, and deliver a detailed inspection report documenting findings, repairs conducted, units requiring further work, and a detector list table. CLIN 002 provides for potential repairs based on Condition Found Reports not to exceed $2,500; additional work requires written contract modification. The NAICS code is 336611, Ship Building and Repairing; the PSC code is J020, Maint/Repair/Rebuild Of Equipment—Ship And Marine Equipment.
Notice text
Statement of Work SIEMENS Fire Alarm System Troubleshooting USCGC Healy
1. GENERAL
1.1 Background The objective of this project is to perform a comprehensive inspection and repair of the existing fire alarm control panel and detectors onboard CGC HEALY. The contractor must perform a groom of the system to resolve insistent trouble alarms. The contractor must be a Siemens technical representative with ability to program newly installed detector heads into system. 1.2 Period of Performance The period of performance is fourteen (14) calendar days from date of contract award for three (3) working days. All work to be done onboard CGC HEALY at USCG Base Seattle Terminal 46. 1.3 Delivery Location Services to be performed at: USCG Base Seattle 1519 Alaskan Way S Seattle, WA 98123 POC: LT Stephen Bruno 1.4 References
•Coast Guard Drawing 420-WAGB-801-001, Rev K, Booklet of General Drawings•ALARMCO, INC Operation and Maintenance Manual
2. SCOPE OF WORK CLIN 0001:The contractor must provide all labor, materials, tools, and equipment necessary to complete the following tasks: 2.1 Clearing Alarms and Troubleshooting
•Review and document the panel's event log to identify the source of all current and historical faults, troubles, and alarm signals.
•Troubleshoot constant “Input source malfunction”, “Not Responding”, and“Communication Error” alarms that populate on FireFinder XLS Fire AlarmControl Panel.•Clear and reset all active alarms and trouble codes on the panel to return thesystem to a "Normal" operating state.
2.2 Program Detectors
•Restore full capability to all fire alarm units onboard with the exception of thosehoused in Generator Room 2 (1-80-2-E).•Program unidentified detector heads into the system including those recentlyinstalled HFP-11 smoke detectors in the Magazine Compartment (1-9-2-M).•Conduct functional tests on the restored detectors to verify proper activationand comunication with the Fire Alarm Control Panel.
2.3 Fire Alarm Panel Inspection
•Ensure Master Fire Alarm Control Panel in the Engineering Control Center andannunciators in Damage Control Central, and the Port and StarboardQuarterdecks are working with full button functionality. See Coast Guard Drawing420-WAGB-801-001 for guidance about the location of the spaces listed above.
3.DELIVERABLES3.1 Inspection Report A detailed inspection report to the US Coast Guard outlining findings of inspection, what repairs were conducted, which units need further work and the final result of system groom. Shall include documentation stating that the fire alarm panel and associated detectors have been restored to full functionality, or if full functionality has not been restored, include a list of specific repairs necessary to restore full functionality, including parts and necessary labor hours. 4. CLIN 002: Potential Repairs based on CFR not to exceed ($2,500 dollars)4.1 Pricing for any additional travel costs, material, or field service days will be requested and handled by the KO under the terms of the contract. Any repairs beyond the base scope identified because of the troubleshooting shall be documented in a Condition Found Report (CFR) with a technical description of the recommended repairs. The CFR shall be provided to the Technical POCs and the Contracting Officer. 4.2 Any additional work will be authorized only by the KO through a written contract modification. The contractor shall not perform any repairs beyond the base scope until specifically authorized in writing by the KO. If the Government elects to proceed with additional repairs, the KO will issue a written contract modification that identifies the authorized additional work and associated firm fixed price. The 5. Detector List Provide a table of all detectors, including at a minimum: •Detector Name•Network Address•Loop•Compartment location ofAn example table format is provided below. Reference current ALARMCO, INC Operation and Maintenance Manual created during the previous Fire & Smoke Detection Replacement Project under Contract No. HSCG40-12-S-30014.
Detector Name
Network Address
Loop
Compartment
Gen Rm 1 FWD
002:115
2
1-80-1-E
...
...
...
...
Files
| File | Type | Posted |
|---|---|---|
| Healy Fire Alarm Solicitation SOW (002).pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Firefighting protection system maintenance | — | No set-aside | |
| Fire Protection Services at USCG Air Station Sacramento | — | No set-aside | |
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business | |
| Notice of Intent to Sole Source - Replacement Marine Fire Detection and Alarm System – Motor Vessel Quincy | ENDIST Rock Island | No set-aside | |
| Dock-side (DS): USCGC WAESCHE Quarter 2 FY27 Repair | — | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity