UPS Battery (Bldg. 5002) FT Riley, KS

Closed Solicitation Posted

Solicitation number
W911RX24Q0009
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
335910 Battery Manufacturing
Place of performance
Fort Riley, Kansas 66442, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood is seeking to replace the uninterruptible power supply battery at Building 5002 on Fort Riley, Kansas. The contractor will provide and install a new Eaton PW 9170+ Series scalable single-phase online tower UPS, remove the existing system, and provide a three-year warranty. Quotes are due by December 12, 2023 and will be evaluated on technical compliance, price, schedule, and past performance on a lowest-price technically acceptable basis.

This requirement has been set aside for small businesses under NAICS code 335910 for battery manufacturing with less than 1,250 employees. The work must be completed within eight weeks of award at the place of performance in Junction City, Kansas. The contractor will replace 24 battery modules and 7 power modules for the existing 12-18kVA UPS system. The government estimates this will be a firm-fixed price contract between $50,000-$150,000 to fulfill the battery replacement and three-year warranty requirements.

Notice text

5 versions

Update #5 · Latest ·

Provide replacement Uninterruptible Power Supply (UPS) for the existing Eaton PW 9170+ Series 12-18kVA expandable UPS with SNMP Card, Wall Mount Maintenance Bypass Switch, Scalable Single Phase Online Tower UPS.

See the RFQ, Attachment-1, Statement of Work and Attachment-2, Specification Sheet for further details.

All questions are due to the POCs NLT 10:00AM (CST) 16 November 2023.  All questions received by the deadline will be answered and issued in an amendment for all potential offerors. 

A site visit is scheduled for 4 Dec 2023 at 1:00 PM at the LMR Main Site.

***Amendment 2, Site Visit Instructions added as attachment 4***

***Amendment 3, Replaced Site Visit Insturctions to post (public)***

***Amendment-4, updating the RFQ Document; adding Attachment-5, Site Visit Questions and Answers; and extending the Solicitation Closing Date to 12DEC23, 10:00AM (CST).***

Update #4 ·

Provide replacement Uninterruptible Power Supply (UPS) for the existing Eaton PW 9170+ Series 12-18kVA expandable UPS with SNMP Card, Wall Mount Maintenance Bypass Switch, Scalable Single Phase Online Tower UPS.

See the RFQ, Attachment-1, Statement of Work and Attachment-2, Specification Sheet for further details.

All questions are due to the POCs NLT 10:00AM (CST) 16 November 2023.  All questions received by the deadline will be answered and issued in an amendment for all potential offerors. 

A site visit is scheduled for 4 Dec 2023 at 1:00 PM at the LMR Main Site.

***Amendment 2, Site Visit Instructions added as attachment 4***

***Amendmen t3, Replaced Site Visit Insturctions to post (public)***

Update #3 ·

Provide replacement Uninterruptible Power Supply (UPS) for the existing Eaton PW 9170+ Series 12-18kVA expandable UPS with SNMP Card, Wall Mount Maintenance Bypass Switch, Scalable Single Phase Online Tower UPS.

See the RFQ, Attachment-1, Statement of Work and Attachment-2, Specification Sheet for further details.

All questions are due to the POCs NLT 10:00AM (CST) 16 November 2023.  All questions received by the deadline will be answered and issued in an amendment for all potential offerors. 

A site visit is scheduled for 4 Dec 2023 at 1:00 PM at the LMR Main Site.

***Amendment 2, Site Visit Instructions added as attachment 4***

Update #2 ·

Provide replacement Uninterruptible Power Supply (UPS) for the existing Eaton PW 9170+ Series 12-18kVA expandable UPS with SNMP Card, Wall Mount Maintenance Bypass Switch, Scalable Single Phase Online Tower UPS.

See the RFQ, Attachment-1, Statement of Work and Attachment-2, Specification Sheet for further details.

All questions are due to the POCs NLT 10:00AM (CST) 16 November 2023.  All questions received by the deadline will be answered and issued in an amendment for all potential offerors. 

A site visit is scheduled for 4 Dec 2023 at 1:00 PM at the LMR Main Site.

Update #1 ·

Provide replacement Uninterruptible Power Supply (UPS) for the existing Eaton PW 9170+ Series 12-18kVA expandable UPS with SNMP Card, Wall Mount Maintenance Bypass Switch, Scalable Single Phase Online Tower UPS.

See the RFQ, Attachment-1, Statement of Work and Attachment-2, Specification Sheet for further details.

All questions are due to the POCs NLT 10:00AM (CST) 16 November 2023.  All questions received by the deadline will be answered and issued in an amendment for all potential offerors. 

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
FTG247 Replace UPS at IDT1, Fort Greely, Alaska Fort Greely, Alaska 99731, United States · NAICS 237130 ENDIST Alaska Total Small Business
Battery, storage Land and Maritime No set-aside
Battery power supply Land and Maritime Total Small Business
Battery, storage Land and Maritime No set-aside
Battery, storage and 1 more item Land and Maritime Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors