About this opportunity

The Department of the Navy Strategic Systems Programs is soliciting proposals for the purchase and installation of three new Uninterruptible Power Supply (UPS) units to replace existing line conditioners at the Strategic Weapons Facility Atlantic (SWFLANT) at Naval Submarine Base, Kings Bay, Georgia. The contract requires 6KVA UPS units with specific technical specifications including 208VAC input, 120VAC output, and a minimum 15-minute runtime during power loss, along with complete installation, operational verification, and removal/disposal of three existing Elgar model 5006B-124 line conditioners. Contractors must submit a work plan for government review prior to installation and complete all work within 60 days of contract award during normal business hours (Monday-Friday, 7:00AM to 4:00PM). A mandatory site visit is scheduled for August 21, 2025, and contractors must comply with extensive security protocols including DBIDS badge registration and background checks for access to the naval base's restricted areas. Proposal submissions are due by September 3, 2025, with evaluation based on a Firm-Fixed-Price arrangement.

This procurement is set aside for Women-Owned Small Business (WOSB) contractors, though the original solicitation description indicates it as a Total Small Business set-aside. The contract involves replacing exactly three UPS units located in Building 5158, Room 212 on the second floor of the Support Building within the Explosive Handling Wharf-One (EHW-1) facility. Installation work must be performed at Naval Submarine Base, Kings Bay, Georgia, within the highly secure Strategic Weapons Facility Atlantic compound, requiring contractors to navigate comprehensive security clearance and access control procedures. The work includes conducting a Facility Evaluation Test (FET) to verify proper output voltages and must adhere to prevailing wage requirements with minimum hourly rates of $17.75 for contracts entered after January 30, 2022. All installation activities are restricted to normal work hours and require strict compliance with naval base security protocols, safety procedures, and hazardous material management guidelines.

Notice text

The Strategic Weapons Facility, Atlantic (SWFLANT) at Naval Submarine Base, Kings Bay, Georgia requires the replacement of three (3) existing Line Conditioners with three new robust, high performance Uninterruptible Power Supply (UPS) units. See attached SF1449 for information.

Files

Notice history

Notice Type Posted
Uninterruptible Power Supply (UPS) Purchase and Installation Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
UPS Refurbishment Keyport, Washington 98345, United States · NAICS 238210 Naval Sea Systems Command No set-aside
UPS, nova 1. 25 KVA NAICS 335931 Naval Supply Systems Command No set-aside
Power supply, unint NAICS 335931 Naval Supply Systems Command No set-aside
Uninterruptible Power Supply (UPS) System with Internal Battery Strings Oak Ridge, Tennessee 37830, United States · NAICS 335999 Department of Energy No set-aside
6135--UPS Battery Replacement VA San Diego Healthcare System San Diego CA 92161, United States · NAICS 335910 Veterans Integrated Service Network 22 Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity