Tunnel 9 Pitch Upgrade
Open Solicitation Posted
- Solicitation number
- FA9101T9PU
- Agency
-
Air Force Test Center
Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332912 Fluid Power Valve and Hose Fitting Manufacturing
- PSC
- 4320 Power And Hand Pumps
- Place of performance
- Silver Spring, Maryland 20903, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Materiel Command Test Center's AFTC/PZIA (Arnold) contracting office is soliciting quotations on behalf of AEDC Tunnel 9 for a modernization of a high-performance hydraulic motion system under a Total Small Business set-aside, with questions due November 23, 2026 and quotations due December 10, 2026 at 10:00 AM Central Time. Amendment 0001 extended the quotation deadline from November 6, 2026. Award will be a single firm-fixed-price purchase order to the responsible small business concern offering the most advantageous quotation.
Place of performance is 716 TS, AF BPN, 10905 New Hampshire Avenue, Silver Spring, Maryland 20903, with delivery and acceptance at AEDC Tunnel 9 on F.O.B. Destination terms. Delivery is due 46 weeks from award. Base CLIN 0001 covers Phase 1 engineering and design. Options CLIN 1001 (Phase 2 manufacturing, test, and delivery) and CLIN 1002 (Phase 3 disassembly, installation, start-up, and commissioning) depend on need and funding. The amendment lists a mandatory site visit on November 16, 2026, with registration due November 11, 2026, while the Q&A states site visits will follow bid review.
Core requirements include a primary control valve with a step response of 55 milliseconds or less, a main actuating cylinder with a 120.5-inch working stroke and 13 ft/s linear speed, a Hydraulic Power Unit, and a filtration and cooling kidney loop. Components must comply with ASME B31.1, ASME BPVC VIII, and ISO 4406, and all components except the HPU and kidney loop must operate in near-vacuum. The contractor must access and handle Controlled Unclassified Information, with an active NIST SP 800-171 self-assessment in SPRS. Detailed drawings and the full Statement of Work become available after CUI verification of company name, CAGE Code, and Unique Entity ID. Contractor personnel must be U.S. citizens with valid REAL ID, trained in AEDC Tunnel 9 safety policy, and hold Confined Space Entry Certification under OSHA 29 CFR 1910.146. The prime contractor needs government approval before acquiring equipment from large-business OEMs or engaging technical support subcontractors. FAR 52.219-14 subcontracting limitations apply, with the 50 percent limitation applying only to the supply portion.
Evaluation factors, in descending order of importance, are Technical Capability (Acceptable/Unacceptable, assessed through a Contractor Statement of Work), Past Performance (CPARS and similar hydraulic system projects), and Price (reasonableness). Only technically Acceptable quotations advance, and Past Performance and Price carry approximately equal weight. Quotations go to maddux.golden@us.af.mil and erica.anglin@us.af.mil, with Erica A. Anglin as Contracting Officer.
Notice text
The Arnold Engineering Development Complex (AEDC) Tunnel 9, located in Silver Spring, MD, requires the comprehensive modernization of a high-performance hydraulic motion system. The scope of this Firm Fixed-Price (FFP) requirement includes the design, engineering, procurement, off-site fabrication, pre assembly, on-site demolition, installation, and commissioning of core system components. All components must comply with ASME B31.1, ASME BPVC VIII, and ISO 4406 standards. Core components include:
• Primary control valve (step response time of 55 ms or less)
• Main actuating cylinder (working stroke of 120.5” capable of achieving a linear speed of 13 ft/s)
• Hydraulic Power Unit (HPU)
• Dedicated filtration and cooling "kidney" loop.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Sources Sought Notice for Tunnel 9 Pitch Upgrade | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Service Air System Revitalization | Air Force Test Center | No set-aside | |
| Med. Press. Pump Module Motor Rebuild | Air Force Sustainment Center | Total Small Business | |
| Cylinder assembly, act | Land and Maritime | HUBZone | |
| Pump Unit, Hydraulic | Land and Maritime | Total Small Business | |
| Actuator, hydraulic | Land and Maritime | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity