Synopsis_GLEN 12-1027_Repair by Replacing Domestic Water Pumps B420
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- FA2550-20-R-0002
- Agency
-
Air Force Space Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Colorado Springs CO 80912 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks proposals to replace the domestic water pumps and associated piping infrastructure at Building 420 of Schriever Air Force Base. The project involves installing multiple smaller variable frequency drive pumps and resizing existing steel piping from 1-1/2 to 6 inches, to provide water flows between 100 and 600 gallons per minute. A hydraulic model was developed to size the pumps and verify the system design. Proposals are due by June 12, 2020, with the period of performance expected to last 300 days upon notice to proceed. Evaluation criteria will include technical approach, past performance, and price.
The acquisition is reserved for Service-Disabled Veteran Owned Small Businesses. The NAICS code is 237110 (Water and Sewer Line and Related Structures Construction) and PSC code is M1 (Construction of Structures and Facilities). The estimated value is between $1 million and $5 million. Key details include replacing the two existing large pumps with three medium pumps covering normal flows, a fourth identical pump for backup, and installing a new fire department connection by the specified deadline.
Notice text
Rather than having two large domestic pumps, a combination of small and medium domestic pumps operating on Variable Frequency Drives (VFDs) shall cover a wider flow range. During normal operation, three pumps will cover a range of flow between about 100 GPM and 600 GPM. The Maximum Day Demand (MDD) plus fire flow demand shall be met with three medium pumps running in parallel. To provide a reliable water supply, a fourth identical medium pump shall be installed as a standby pump. Since the diesel fire pump is new as of 2012, this pump shall remain in service, as is, as a backup for firm capacity. Table 1 of the Design Analysis (pg 11, attached) lists the major pump and VFD equipment. Additionally, all steel water piping infrastructure in and around Building 420 requires replacement, with pipes resized for the flows from the new pumps, and equipped with new valves and fittings to provide simplicity of maintenance and repairs. Pipe replacement is detailed in the design drawings.
The water distribution system shall supply water demands with sufficient service pressure and water quality over a range of fluctuating conditions that vary throughout the day and over the course of a year. AECOM created a hydraulic model using AFT Fathom software to verify and complete the final hydraulics. This included calculating the required head and pump turndown for each of the three pump types (Medium Pump, Small Pump, and Jockey Pump) at the required flow conditions, taking into account the frictional losses in the pipe system due to the recommended change in pipe sizes within the building. AECOM targeted a distribution pressure of 84 psi for normal water flow and 110 psi for fire flow.
Refer to “Design Analysis_Redacted - GLEN12-1027” (attached) for more details on demand and pump operating points.
The Contractor shall install a new fire department connection where easily accessed from the roadway. Exact location is to be determined by installer and approved by the SAFB fire department. Connection shall consist of two 2 ½ inch connections with NH internal threaded swivel fitting(s). Threading shall be 2.5 – 7.5 NH standard thread as specified in NFPA 1963.
Files
| File | Type | Posted |
|---|---|---|
| 01 SOW GLEN 12-1027.docx | DOCX document | |
| 08 Planning - Project AF 66 Form - GLEN12-1027.xls | XLS spreadsheet | |
| 09 Wage Determination.pdf | ||
| 05 Existing Conditions Drawing - GLEN12-1027.pdf | ||
| 07 SAFB Environmental Supplement.docx | DOCX document | |
| Synopsis GLEN 12-1027.docx | DOCX document | |
| 04 Design Drawings - GLEN12-1027.pdf | ||
| 03 Requirements - 01 55 04 - SAFB Security Requirements.doc | DOC document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Award_Notice_GLEN 12-1027_Repair by Replacing Domestic Water Pumps B420 | Award Notice | |
| Solicitation_GLEN 12-1027_Repair by Replacing Domestic Water Pumps B420 | Solicitation | |
| This notice | Pre-Solicitation | |
| Repair by Replacing Domestic Water Pumps B420 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| 16292 Steam Boiler Replacement | Air Force Sustainment Center | Total Small Business | |
| Y1DZ--598-22-115 Site Utility Infrastructure-NLR | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| J043--Damen Sump Pump Control System Repair | Veterans Integrated Service Network 12 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity