Replace Kadena Tanks LXEZ241015

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
FA527025R0032
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Kadena AFB, Okinawa Japan 96368

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Pacific Air Forces is soliciting contractors to replace fuel and waste oil storage tanks at Kadena Air Base in Japan. The project requires installation of Convault tanks or approved equivalents to address leak and corrosion issues, with some existing tanks testing positive for asbestos and lead-based paint requiring abatement services. Contractors must replace associated piping and accessories while incorporating seismic protection, antiterrorism measures, and fire protection systems. The work must integrate sustainable principles and life cycle cost-effective practices in accordance with UFC 1-200-02 High Performance and Sustainable Building Requirements. The solicitation was posted on July 3, 2025, with proposals due by August 25, 2025.

This opportunity operates under NAICS code 237120 for Oil and Gas Pipeline and Related Structures Construction and does not include any set-aside designations for small businesses or other socioeconomic categories. The contract will be performed at Kadena Air Base in Nakagami District, Okinawa, Japan, requiring contractors to work at this overseas military installation. The solicitation notice does not specify contract values, quantities of tanks to be replaced, or identify current incumbent contractors. Contractors responding to this opportunity should reference the Kadena Design Guide sections 13.11.1-3 and 21.1.7 for additional technical guidance and must ensure compliance with all applicable military construction standards for fuel storage facilities.

Notice text

Replace the listed fuel and waste oil storage tanks on Kadena Air Base. New tanks shall be Convault tanks, or an approved equal, to mitigate leak and corrosion. Refer to Kadena Design Guide sections 13.11.1-3, and 21.1.7 for more guidance. Some tanks have tested positive for asbestos and/or lead based paint, which will require abatement. Work also includes all necessary replacement of associated piping and accessories to ensure the tanks are complete and usable. Include seismic protection, antiterrorism, and fire protection measures as required. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with UFC 1-200-02. Work for the project is described in more detail in Section 8 of this Statement of Work (SOW). Sustainable principles, to include life cycle cost- effective practices shall be integrated into the design, development, and construction of the project(s) in accordance with the latest version of UFC 1-200-02, High Performance and Sustainable Building Requirements.

Notice history

Notice Type Posted
Replace Kadena Tanks LXEZ241015 Award Award Notice
This notice Latest solicitation Solicitation
Replace Kadena Tanks LXEZ241015 Pre-Solicitation
Replace Kadena Tanks Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan Yokota Air Base, Japan · NAICS 237120 ENDIST Japan No set-aside
Vehicle Maintenance Shop, Kadena Air Base, Okinawa, Japan Kadena Air Base, Okinawa, Japan · NAICS 236220 ENDIST Japan No set-aside
DCDO Septic Tank and Sewage Treatment Maintenance 96367 Japan · NAICS 221320 Pacific Air Forces No set-aside
Fuel Tank Inspection NAICS 811310 Army Contracting Command No set-aside
P530 Aircraft Intermediate Maintenance Facility, Kadena Air Base, Okinawa, Japan Kadena Air Base Okinawa Japan · NAICS 236220 ENDIST Japan No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity