Replace Kadena Tanks LXEZ241015

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
FA527025R0032
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Kadena AFB Okinawa 96368 Japan

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Pacific Air Forces is seeking contractors for a design-build replacement of fuel tanks at Kadena Air Base through project "Replace Kadena Tanks LXEZ241015." The project involves replacing fuel and waste oil storage tanks at eight facilities (B176, B329, B613, B786, B1206, B3413, B3489, B3506) with new Convault tanks or approved equivalent to prevent leaks and corrosion. The contractor must address hazardous materials including asbestos and lead-based paint abatement, replace all associated piping and accessories, and incorporate seismic protection, antiterrorism, and fire protection measures. The work must comply with sustainable building practices per UFC 1-200-02 and Kadena Design Guide requirements. This pre-solicitation notice was posted on June 16, 2025, with responses due by June 30, 2025.

This opportunity does not utilize any set-aside designations and falls under NAICS code 237120 for Oil and Gas Pipeline and Related Structures Construction. No incumbent contractors or current service providers are identified in the notice. The contract opportunity does not specify award values, budget ranges, or detailed timelines for completion. Construction activities cannot commence until approval of the Environmental Protection Plan and AF Form 103 work clearance, with all on-site safety requirements coordinated through the 718th Civil Engineer Squadron. The project requires integration of life cycle cost-effective practices throughout the design, development, and construction phases.

Notice text

This project shall accomplish a design-build replacement of the fuel tanks located at the following facilities. B176, B329, B613, B786, B1206, B3413, B3489, B3506.

Replace the listed fuel and waste oil storage tanks on Kadena Air Base. New tanks shall be Convault tanks, or an approved equal, to mitigate leak and corrosion. Refer to Kadena Design Guide sections 13.11.1-3, and 21.1.7 for more guidance. Some tanks have tested positive for asbestos and/or lead based paint, which will require abatement. Work also includes all necessary replacement of associated piping and accessories to ensure the tanks are complete and usable. Include seismic protection, antiterrorism, and fire protection measures as required. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with UFC 1-200-02. Work for the project is described in more detail in Section 8 of this Statement of Work (SOW). Sustainable principles, to include life cycle cost- effective practices shall be integrated into the design, development, and construction of the project(s) in accordance with the latest version of UFC 1-200-02, High Performance and Sustainable Building Requirements.

Construction activities may commence after the approval of the Environmental Protection Plan (EPP) and AF Form 103 (work clearance). The Contractor shall coordinate on-site safety requirements through the 718th Civil Engineer Squadron (718 CES).

Notice history

Notice Type Posted
Replace Kadena Tanks LXEZ241015 Award Award Notice
Replace Kadena Tanks LXEZ241015 Latest solicitation Solicitation
This notice Pre-Solicitation
Replace Kadena Tanks Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan Yokota Air Base, Japan · NAICS 237120 ENDIST Japan No set-aside
Vehicle Maintenance Shop, Kadena Air Base, Okinawa, Japan Kadena Air Base, Okinawa, Japan · NAICS 236220 ENDIST Japan No set-aside
Fuel Tank Inspection NAICS 811310 Army Contracting Command No set-aside
DCDO Septic Tank and Sewage Treatment Maintenance 96367 Japan · NAICS 221320 Pacific Air Forces No set-aside
P530 Aircraft Intermediate Maintenance Facility, Kadena Air Base, Okinawa, Japan Kadena Air Base Okinawa Japan · NAICS 236220 ENDIST Japan No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity