Repair or Replace Switchgear 4A at VAMC Central Western MA

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24126Q0814
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Leeds, Massachusetts 01053, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1 seeks repair or replacement of Generator 4A Switchgear at the Edward P. Boland Campus in Leeds, Massachusetts, with quotes due September 18, 2026. The procurement is a 100% total small business set-aside under NAICS 811310, with a $12.5 million size standard.

Place of performance is Leeds, Northampton, MA 01053. The scope requires either repair or replacement quotes—or both—for the existing 350KW generator switchgear, including temporary 3-phase 120Y208 generator and cables, installation of new or repaired switchgear capable of NFPA 99 compliance, required meters (ammeter, voltmeter, frequency meter, watt meter, hour meter), and a communications module for alarms via BACnet with digital HMI. All work must comply with NFPA, VHA, OSHA, EPA, and Massachusetts DEP standards. Contract performance is approximately nine months from Notice to Proceed.

Offerors must submit firm-fixed-price proposals with itemized labor costs (electrical foreman, electricians, and testing/commissioning hours) and material and service line items. Required submissions include signed quotes, company information and UEI, technical proposal with OEM training certifications and detailed technical approach, minimum three recent relevant past performance contracts, equipment condition assessment with recommendations, NFPA 99 compliance certification, and estimated project timeline. Prices must remain firm for 60 days. All offerors must hold active SAM registration and confirm small business status.

Evaluation prioritizes technical compliance and past performance over price. The Quality Assurance Surveillance Plan establishes five performance standards with 95–100% acceptable quality levels, including timely completion per schedule, compliance with applicable standards, and site management protocols. Submissions go to Contracting Officer Juliette Buchanan via email by 4:00 PM EST on September 18.

Notice text

See the attached Combined Synopsis/Solicitation for 36C24126Q0814.

Files

Notice history

Notice Type Posted
J061--631-26-4-4808-0622 Repair or Replace Swich Gear 4A (VA-26-00080313) Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business
Z2DA--666-27-102 Lightning Protection Update B71N NAICS 236220 Veterans Integrated Service Network 19 No set-aside
J061--Uninterruptible Power Supply St. Louis VA Medical Center NAICS 811210 Veterans Integrated Service Network 15 No set-aside
Update and Replace Remaining ATS's North Chicago, Illinois 60064, United States · NAICS 238210 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
J061--triennial electrical maintenance - amendment 4 POP: 12/01/2026 - 11/30/2027 plus 4 option years Slvhcs New Orleans, Louisiana 70119, United States · NAICS 238210 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity